EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S

Similar documents
EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP

Cooling Solutions for Mission-Critical Electronics

Quality Enclosures and cooling solutions for every environment

Product Information Packet

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

SEALED ENCLOSURE COOLING

SEALED ENCLOSURE COOLING

Thermal Management INDEX. Management. Thermal TM-1

Quality Enclosures. Service Excellence.

Product Information Packet

RACK-MOUNT Air Conditioners

FOR TM-16 EMERGENCY WARNING SYSTEM

NOREN Products. Compact Cabinet Coolers

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation Instructions Type XPMC Air Heater for Hazardous Locations

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

dissipation: air conditioning, compressed air and heat exchangers. Air conditioning was

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

AC-162 Peltier-Thermoelectric Air Cooler

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Installation Instructions

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

SAVE THESE INSTRUCTIONS

Silverware Pre-washing System INSTALLATION

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Instant Hot Water Dispenser Owner s Manual

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Thermal Electronics Corp. Service & Parts Manual. Rev.1 07

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

Rotary XL (558 Series) and Classic (548 Series)

CB 8000 AMBIENT AIR CONDITIONED FRESH AIR SUPPLY SYSTEM OPERATOR S MANUAL

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Installation Instructions

Installation Instructions

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

TB SERIES. Glycol Pizza/Salad/Sandwich Prep Tables Self-Contained. Project Quantity Item # Model Specified: CSI Section 11400

MERMAID CONDENSATOR INSTALLATION MAINTENANCE & TROUBLESHOOTING GUIDELINES

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

E Z S E R I E S " W X 16" H

Intelligent Electronic Enclosure Thermal Management Systems

EXPERIMENTAL INVESTIGATION OF THERMOELECTRIC AIRCONDITIONER USING SEEBECK MODULES

Eemax, Inc. Electric Tankless Water Heaters

Installation Instructions

Instructions. Duct Mount Accessory Q Rev: 11/

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

HE220, HE260 Humidifier Installation Kit

Maintaining Packaged Rooftop Units

ENCLOSURE COOLING. Glossary

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

INSTALLATION INSTRUCTIONS

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTEGRITY SERIES K_NA4C4P32L KNA6C4P32L

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

G16 Luxury Collection. Twin Bowls Kitchen Sink. Drop-in. Owner s Manual. Undermount

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Installation Manual. Breeder Control Installation Manual Patented U.S. Patent No. 7,980,129 and Patents Pending

Assembly and Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

INSTALLATION INSTRUCTIONS

Privacy Aluminum Shade

24 VAC SYSTEM CONTROL KIT

GENESIS Indoor Air Conditioners

INSTALLATION INSTRUCTIONS

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

Assembly and Instruction Manual. #CR-2550 shown below

DS 2001 REVISED Humidifier Assembly and Instruction Manual

5800 Refrigerator Compressor Capacitor/Relay Kit

VERTICAL HIGH OUTPUT VHC-IOM INSTALLATION AND MAINTENANCE INSTRUCTIONS VHC INSTALLER MUST BE A TRAINED, EXPERIENCED SERVICE TECHNICIAN

Dishwasher Installation Instructions DW 24XT/DW 24XV

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

AC-046 Peltier-Thermoelectric Air Cooler

Transcription:

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 1500 Btu MODEL # S AAC-145-T-E AAC-145-4XT-E AAC-145-T-E-HC AAC-145-4XT-E-HC AAC-145-XXXXX Cooling Solutions for Mission-Critical Electronics

TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 PRINCIPLES OF OPERATION... 3 2. INSTALLATION 2.1 CHOOSING A LOCATION... 4 2.2 ORIENTATION... 4 2.3 PREPARING THE ENCLOSURE... 6 2.4 INSTALLING THE AIR CONDITIONER... 6 INSTALL THE DRIP PAN... 7 APPLY POWER... 7 3. OPERATION 3.1 thermostat set points and heating cooling units... 9 3.2 maintenance... 9 4. APPENDIX... 10 EIC SOLUTIONS INC. 700 VETERANS WAY, SUITE 200 WARMINSTER, PA 18974 PHONE 1-215-443-5190 or 1-800-497-4524 FAX 215-443-9564 EMAIL info@eicsolutions.com VISIT US ON THE WEB AT www.eicsolutions.com. D-09 Rev. D 11/12/2013 2

1. GENERAL INFORMATION 1.1 PRINCIPLES OF OPERATION I n 1834 Jean Peltier discovered that by passing a current through two dissimilar conductors the junction of those materials will either absorb or release heat depending on the direction of the current flow. Thirteen years earlier Thomas Seebeck had discovered that current would flow when you placed a temperature gradient across the junction of two dissimilar metals. These two discoveries were the basis of thermoelectrics. With the advent of modern semiconductors thermoelectric devices became practical for real world applications and are now found in everything from consumer goods to spacecraft. Your EIC Solutions Thermoelectric Air Conditioner operates on this principle so there is no compressor and no expensive, ozone depleting CFC s. EIC s air conditioners use Thermoelectric modules sandwiched between high performance aluminum heat sinks, high CFM axial fans, and a patented electronic design to pump the heat from the inside of your enclosure to the outside, without exposing your delicate electronics to any outside air or contaminates. See Figure 1.1. EIC uses only the highest quality components in our air conditioners and you can expect years of trouble free cooling from these solid-state devices. Every unit we sell is backed by our one year parts and labor warranty. AMBIENT AIR REMOVES HEAT FROM HOT SIDE HEAT HOT SIDE HEAT COLD SIDE HEAT COLD AIR CIRCULATED WITHIN THE ENCLOSURE FANS FANS AMBIENT AIR REMOVES HEAT FROM HOT SIDE HEAT HOT SIDE HEAT COLD SIDE HEAT COLD AIR CIRCULATED WITHIN THE ENCLOSURE FIGURE 1.1 3

2. INSTALLATION 2.1 CHOOSING A LOCATION ON YOUR ENCLOSURE When choosing a mounting location for your unit, be sure to keep air flows of both the interior and exterior heatsinks and fans in mind. Adequate clearance between the fans/heatsinks and nearby surfaces is required for unrestricted air flows which will ensure optimal performance and long, trouble free operation. The general rule is to allow a minimum of two inches between the fans or heatsinks and any surface. Refer to figure 1.1 for an air flow diagram. Other considerations in deciding on a mounting location include; allowing access to thermostat (this will be inside the enclosure) if frequent adjustments are to be made; allowing access to the hot side heat sinks (this will be on the outside of the enclosure) for cleaning if the unit will be used in a harsh, dirty environment. 2.2 ORIENTATION Your AC unit can be mounted either vertically on the front, rear or side of your enclosure or horizontally on the top of your enclosure. See Figure 2.1 and 2.2. Vertically mounted 1500 Btu units are always mounted with the exposed heatsink fins facing up and down, never left and right. (Fig. 2.1) Vertical installations often require the use of a Condensate Drip Pan (part # DP-V) depending on a number of factors including internal enclosure temperatures and ambient temperatures, humidity levels, quality of enclosure seals, and frequency of enclosure opening. We strongly recommend the use of a drip pan to protect the electronics from dripping condensate. (Fig. 2.1) Mounting the unit horizontally on the side of an enclosure, will cause condensate to drip in an uncontrolled manner, possibly damaging electronic equipment within the enclosure. If this orientation is the only possible configuration, contact the Engineering Dept. at EIC for a custom solution. Horizontally mounted 1500 Btu units always require a factory installed drip pan (part # DP-145H) to prevent dripping condensate from damaging electronic equipment. (Fig. 2.2) In either orientation, issues regarding access should be considered and minimum clearances must be maintained as outlined in Section 2.1 of this manual. 4

ENCLOSURE COLD SIDE HEAT HOT SIDE HEAT COLD SIDE FANS HOT SIDE FANS COLD SIDE OF AC (INSIDE OF ENCLOSURE) HOT SIDE OF AC (OUTSIDE OF ENCLOSURE) COLD SIDE HEAT HOT SIDE HEAT DP-V DRIP PAN DRAIN TUBE VERTICAL INSTALLATION OF 1500 BTU UNIT WITH DP-V VERTICAL DRIP PAN AND DRAIN TUBE FIGURE 2.1 HOT SIDE FANS HOT SIDE HEAT COLD SIDE HEAT SINK FINS HOT SIDE OF AC (OUTSIDE OF ENCLOSURE) COLD SIDE OF AC (INSIDE OF ENCLOSURE) HOT SIDE HEAT COLD SIDE HEAT SINK FINS ENCLOSURE COLD SIDE FANS DRAIN TUBE HORIZONTAL INSTALLATION OF 1500 BTU UNIT WITH INTERNALLY MOUNTED DP-145H DRIP PAN AND DRAIN TUBE FIGURE 2.2 5

2.3 PREPARING THE ENCLOSURE To mount the 1500 Btu unit you will need to cut an opening in your enclosure and drill mounting holes. Cut-out drawings (see Appendix) showing the cut-out sizes and hole locations have been included in this manual. The instructions for installing the air conditioner are printed below. TOOLS AND MATERIALS NEEDED: Pencil Scissors Tape Measure Jigsaw or suitable alternative Electric drill # 29 drill bit (.136 ) (Not used for extension frame option) # 8-32 tap and tap handle (Not used for extension frame option).203 drill bit (Extension frame option only) # 8-32 x 3/8 stainless machine screws (supplied) Nylon washers for NEMA 4X installations (supplied) One neoprene gasket (supplied) CUT THE OPENING AND DRILL MOUNTING HOLES IN THE ENCLOSURE 1. Using the guidelines provided in the installation manual choose an appropriate location for the air conditioner on your enclosure. 2. Layout the cut-out and hole pattern for the AC on the enclosure. Refer to Appendix A for standard flange only. Standard flange air conditioners do not contain NF in the part number, and the mounting flange measures 20.25 x 13. Refer to Appendix B for narrow flange models only. Air conditioners that are narrow flange units contain NF in the part number, and the mounting flange measures 20.25 x 12. Refer to Appendix C for extension frame models. 3. Before cutting or drilling check that the location meets the clearance requirements as specified in the installation manual. 4. Using a pencil, center punch or other method, mark the exact center point of each mounting hole on the enclosure. You will use 10 holes for a NEMA 12 installation and all 20 holes for a NEMA 4X installation. 5. Using the jigsaw, cut the opening in the enclosure. 6. Using the appropriate drill size, drill a hole at each of the marks you made earlier. 7. Using the 8-32 tap, tap each of the holes you have drilled. (Non-Extension Frames Only) 2.4 INSTALLING THE AIR CONDITIONER INSTALL THE AIR CONDITIONER 1. Lay the air conditioner down with the cold side (side with the thermostat) facing up. 2. Take the supplied gasket and lay it down on the flange. 3. Take one of the supplied mounting screws and, from the under side of the flange, push it up through the top right mounting hole, and through the hole in the gasket. The gasket hole is undersized and will hold the screw in place. Repeat this on the top left mounting hole. 4. Set the AC unit in the hole you ve cut in the enclosure, and using a screwdriver, carefully start the two screws you attached to the gasket to the tapped holes in the enclosure. Do not tighten these at this time. 6

5. Install the rest of the screws in the flange placing a nylon washer on each fastener and screw them into the tapped holes in the enclosure. Do not tighten them completely. a. If you have purchased a vertical drip pan, you will need to install the three long screws in the three center holes in the bottom flange. b. If this is an indoor installation with no chance of exposure to water or other liquids, you can use 10 screws per the NEMA 12 pattern in the Appendix. c. If this is a NEMA 4X installation (outdoors or chance of exposure to liquids) use all 20 screws provided. 6. Remove the two starter screws and place a nylon washer on each and reinstall. 7. Tighten all screws. INSTALL THE DRIP PAN 1. Two hose fittings were provided with the drip pan, a right angle and a straight one. Choose one and install it on the drip pan. Be sure if you use the right angle fitting it is facing the desired direction prior to installing the drip pan. 2. There are three mounting holes in the drip pan, match these with the long mounting screws protruding into the enclosure at the bottom of the AC unit. Push the drip pan onto these screws. 3. Using the three 8-32 keps nuts provided, attach the drip pan to the air conditioner. 4. Attach the supplied PVC drain tube to the hose fitting on the drip pan. This tube should be routed to the bottom of the enclosure and fed through a 3/8 hole to the outside. 5. If you purchased a horizontal drip pan, it is installed at the factory and you will only need to install the hose fitting and PVC drain hose. YOU MUST USE THE FACTORY INSTALLED HORIZONTAL DRIP PAN IF YOU INSTALL THE AIR CONDITIONER HORIZONTALLY (FIG 2.2) ON THE TOP OF YOUR ENCLOSURE. FAILURE TO DO SO MAY ALLOW CONDENSATE TO DRIP IN AN UNCONTROLLED MANNER CAUSING DAMAGE TO YOUR EQUIPMENT. APPLY POWER Once the air conditioner is mounted, check the serial label and confirm the voltage required and then apply appropriate power as outlined below. 120 VAC units plug into standard 120 volt, grounded outlet. Amperage for a 120 VAC unit is 6.3 amps. 220 240 VAC units this unit will not have a plug on the end. Connect the wires to an appropriate power source using standard safe wiring methods. Wire colors are as follows: Black or Brown line White or Blue line/neutral Green or Green/Yellow ground A wiring diagram is shown in Fig. 2.4. Amperage for a 220 VAC unit is 4.6 amps. 7

Figure 2.4 DC voltage units this unit will not have a plug on the end. Connect the wires to an appropriate power source using standard safe wiring methods. Wire colors are as follows: Red - Positive Black - Negative Green ground A wiring diagram is shown in Fig. 2.5 below. Figure 2.5 For other voltages you will receive a separate wiring diagram showing the correct method of applying power. If you purchased a Digital Temperature Controller with your AC unit, a separate wiring diagram has been provided which will show the correct method of applying power to your particular air conditioner. Upon applying power to the air conditioner the fans on the cold side (inside the enclosure) will come on. The hot side fans (outside the enclosure) may also run depending on where the thermostat is set. The cold side fan always runs to circulate air within your enclosure thereby eliminating any hot spots. The hot side fans will only run when the air conditioner is cooling they are pumping the heat from the inside of your enclosure to the outside air. 8

3. OPERATION 3.1 THERMOSTAT SET POINTS AND HEATING/COOLING UNITS SETTING THE THERMOSTAT Your EIC air conditioner is equipped with an adjustable thermostat. The set point you choose should be based on the desired internal temperature of the enclosure. The air conditioner will run until the set point temperature is achieved within the enclosure and then the hot side fans and the thermoelectric cooling modules will shut down. The cold side fan will continue to run, circulating the air to maintain a uniform temperature within the enclosure. HEATING AND COOLING UNITS If you purchased an HC unit (heating and cooling), the heater operation is controlled by a fixed-point thermostat. This thermostat is set to turn the heaters on when the temperature within the enclosure falls to approximately 45 F and turn the heaters off when the temperature rises to approximately 55 F. The cooling operation is controlled by the adjustable thermostat. To avoid having the heating and cooling on at the same time, do not set the cooling thermostat below 70 F. 3.2 MAINTENANCE MAINTENANCE EIC Thermoelectric Air Conditioners are virtually maintenance-free. The only time maintenance is required is when a unit is installed in an extremely dirty environment. In these cases, the hot side heat sinks (outside the enclosure) should be inspected regularly for a build-up of dust or dirt. If a build-up is present on the heat sink fins, it can be easily removed as follows: 1. Disconnect the power from the unit. 2. Dry dust/dirt can be removed using compressed air to blow out the heat sinks. Do not direct any high-pressure air at the fans. 3. NEMA 4X models of our air conditioners are designed to allow for water wash down of the hot side of the unit, which is outside of the enclosure (never the cold side which is inside the enclosure). A pressure washer can be used to carefully clean the hot side heat sink fins. Never direct high-pressure water at the fans or the joint formed by the mounting flange, gasket and enclosure. Never allow the cold side of your unit to get wet. Always check your serial label before proceeding with a water wash down. Keeping the hot side heat sink fins free from any insulating build-up of dirt or dust will ensure long, trouble-free operation of your air conditioner. ONLY NEMA 4X UNITS, WITH MODEL NUMBERS BEGINNING WITH AAC-145-4XT, ARE DESIGNED FOR THE HOT SIDE OF THE AIR CONDITIONER (OUTSIDE THE ENCLOSURE) TO TOLERATE EXPOSURE TO WATER. NEMA 12 UNITS, WITH MODEL # S BEGINNING WITH AAC-145-T, ARE NOT DESIGNED TO BE EXPOSED TO WATER AND SHOULD NEVER BE WASHED DOWN. NEVER EXPOSE THE COLD SIDE OF ANY AIR CONDITIONER (INSIDE THE ENCLOSURE) TO WATER. If you have any questions about any aspect of your EIC air conditioner, don t hesitate to call us at the numbers listed below. 9

APPENDIX A and B NEMA 12 installations: Use holes marked with + (10x) NEMA 4 installations: Use all holes (20x) Enclosure cutout for Standard Flange models only, DO NOT use with Narrow Flange models or Extension Frame Holes to be 8-32 TAP Drawing A Enclosure cutout for Narrow Flange models only, DO NOT use with standard models or Extension Frame Drawing B 10

APPENDIX C Enclosure cutout for 1500 BTU air conditioner EXTENSION FRAME ONLY Holes to be.203 11