!!!! Copyright Texas Fire Chiefs Association. Edition 2. January 2015

Similar documents
!!!!! Program Checklist

CHAPTER 1 ADMINISTRATION AND ORGANIZATION

REQUIREMENTS. For FIRE DEPARTMENTS. State of West Virginia. Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY

NFPA Self Assessment Manual

DEPARTMENT SUMMARY. Personnel Services $ 7,780,971 $ 7,989,600 $ 7,707,680 $ 8,231,680. Operating Expenses 835, , , ,870

Chapter 1 Test. Directions: Write the correct letter on the blank before each question.

Town of Whitby By-law #

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

BERKELEY FIRE DEPARTMENT (141 FTE)

Annual Report Components

M E M O R A N D U M. Please do not vote negatively because of editorial errors. However, please bring such errors to my attention for action.

Grace Merkes, Assembly President Kenai Peninsula Borough Assembly Members. Confirmation of New Nikis i Fire Service Area Chief

MCSCS Proposed Changes to Fire Service Regulations

Saratoga Springs Fire & Rescue

TRAINING AND EDUCATION PAYMENT POLICY FOR TESTING

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

FILED 07/31/ :16 PM ARCHIVES DIVISION SECRETARY OF STATE & LEGISLATIVE COUNSEL

Thomasville fire rescue

FIRE TECHNOLOGY (FIRE)

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

Fire Department Orientation / Organization

SIOUX FALLS FIRE RESCUE STRATEGIC PLAN

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

FIRE PROTECTION AND EMERGENCY SERVICES BYLAW

AMADOR FIRE PROTECTION DISTRICT

Mission. Vision. To set the standard for excellence and innovation in public safety. Department Description

WELCOME TO ROSEVILLE UNIVERSITY

CERTIFICATION COURSE CRITERIA CHART Revised 02/21/19 - Subject to Change

Prereq: FOD 131 or Instructor Permission

THE CORPORATION OF THE CITY OF WATERLOO BY-LAW NUMBER2010-; 09(:'A FIRE DEPARTMENT ESTABLISHING AND REGULATING BY-LAW

Transition to NFPA Professional Qualifications Standards: OFMEM Grandfathering Policy. Office of the Fire Marshal and Emergency Management (OFMEM)

Summary. firefighter training in Since that time the firefighter had attended semi-annual

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

WELCOME TO THE YUKON FIRE SERVICE

Rescues individuals in danger from fire, vehicle accidents, industrial accidents and other situation requiring extraction.

South Lyon Fire Department 2012 Annual Report

THE CORPORATION OF THE TOWN OF ATIKOKAN BY-LAW NO


FIRE DEPARTMENT FIRE CHIEF. Deputy Fire Chief Operations Section. Assistant Fire Chief Planning & Budget Section

Performance and Cost Data. fire services

NATIONAL FIRE PROTECTION ASSOCIATION Fourth Survey of the Needs of the U. S. Fire Service

Firefighter/ Emergency Medical Technician MASON VALLEY FIRE PROTECTION DISTRICT

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Enactment Date: Rapid Intervention Team and RIT Officer

ESF 4. Fire Fighting

CAMDEN COUNTY FIRE COORDINATOR

Upon completion of this course, the student will be able to:

Codes and Standards FFP1510, BFST1510, ATCP1510

FIRE PROTECTION DIVISION PRIMARY FOCUS

FIRE FIGHTER I APPLICATION PENNSYLVANIA VOLUNTARY FIRE SERVICE CERTIFICATION PROGRAM NFPA Edition

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

TAHOE DOUGLAS FIRE PROTECTION DISTRICT JOB DESCRIPTION Fire Inspector Fire Prevention


BYLAW 5542 *******************************************************************************

9S / 9E Inspection Worksheets. The fire department should complete the following sheets prior to inspection date

Branch Fire Rescue Services

The Technical Committee on Fire Service Training

Romulus Fire Department 2016 Annual Report

FORT MYERS BEACH FIRE DEPARTMENT JOB DESCRIPTION

SAFETY COURTESY PROFESSIONALISM EFFICIENCY

Services the Agency is Required to Provide Services

Newfoundland and Labrador Association of Fire Services PMA Conference St John s April 23,

Fire FY Performance Plan

Cumru Township Fire Department Master Policies/SOG(s) Sheet

Required Materials For complete material(s) information, refer to

Independence, Missouri FIRE DEPARTMENT

PUBLIC SAFETY TELECOMMUNICATOR (ALARM DISPATCHER)

BCGEU JOB DESCRIPTION MINISTRY OF FORESTS

Fire Department. Mission Statement

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC. FORM: ACC 5 (Accreditation Application Form-2018) Valid from 1 October September 2018

FIRE PROTECTION DIVISION PRIMARY FOCUS

NFPA Fire Inspector I Study Guide

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

LTF&R FEBRUARY 2018 MONTHLY REPORT

FIRE & RESCUE SERVICES

Category V. NOTE: Fire Investigations are covered in Criterion 5D.

CURRICULUM VITAE STEVEN J. MOORE, CFI

VILLAGE OF NEW MARYLAND BY-LAW NO. 20 A BY-LAW RESPECTING THE NEW MARYLAND FIRE DEPARTMENT

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Program of Instruction Course Syllabus

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Interior Industrial Fire Brigade Member- NFPA 1081, 2007

Your Partner in Safety Solutions

Chapter 50 FIRE PREVENTION AND PROTECTION*

SAGINAW FIRE DEPARTMENT SAFER

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION GENERAL PROVISIONS

The 2012 Fire Suppression Rating Schedule (FSRS)

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

Brad Goudie May 16, Fire Marshal EMS Emergency Management Fire Department

Public Safety Institute Fire & Rescue Course Fee Catalog

EXECUTIVE SUMMARY. Lyle Sumek Associates, Inc. Phone (407) St, Edmunds Place Fax (407)

2017 Eastside Fire & Rescue Response Coverage Report

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

NFPA. How to Nail. Your First-Due Responsibility. Part 2: What the Standards Recommend

TABLE OF CONTENTS 8. ANNEX B

CHAPTER House Bill No. 69

Mayor and Council Briefing Cherry Hill Fire Department Operations. March 26, 2018

Robson Forensic Engineers, Architects, Scientists & Fire Investigators

Town of Cochrane Policy

Transcription:

Copyright Texas Fire Chiefs Association Edition 2 January 2015

Table of Contents CHAPTER 1 ADMINISTRATION AND ORGANIZATION... 3 CHAPTER 2 EMERGENCY MEDICAL SERVICE... 11 CHAPTER 3 TRAINING... 14 CHAPTER 4 SPECIAL OPERATIONS... 20 CHAPTER 5 RECORDS AND INFORMATION MANAGEMENT... 36 CHAPTER 7 FIRE PREVENTION RISK REDUCTION COMMUNITY OUTREACH... 42 CHAPTER 8 RESPONSE ANALYSIS... 44 CHAPTER 9 - COMMUNICATIONS... 50 CHAPTER 10 SAFETY AND HEALTH... 56 CHAPTER 11 RESOURCES MANAGEMENT... 60 CHAPTER 12 PROFESSIONAL STANDARDS AND CONDUCT... 64

CHAPTER 1 ADMINISTRATION AND ORGANIZATION The administration and organization of a fire service agency is crucial to the achievement of its mission. Clear lines of authority and responsibility are necessary to fix responsibility and assure performance. Critical issues of organization, budgeting, and financial management, policies and procedures, authority and jurisdiction, and asset management are covered in this chapter. Effective administration and organization will assist the agency in providing efficient and effective services to the citizens of the community. 1.01 Organization The Agency has a current organizational chart depicting the organizational components available to all personnel. The chart is updated as needed but should be reviewed annually. None --Copy of current organizational chart, And --Some method of showing annual review of the organizational chart (Review or issue date on chart or policy stating annual review), And --Organizational charts are made available to all personnel, And Signed for by officer as part of department policy manual, Or Statement on DSF of how made available to personnel, Or Photo of posting on bulletin board, Or Observation of chart posted on bulletin board (On-site). 1.02 Budget The Agency develops, submits, and manages a budget, and a written directive designates a position responsible for the budget. None --Copy of directive or memo designating who is responsible for the budget preparation and management, And --Copy of written directive outlining budget process, Or --Copy of instructions for budget preparation, Or --Copy of submitted budget request, And

--Copy of monthly budget summary or status report. 1.03 Purchasing and Receivables The Agency has a written directive instructing personnel on how to purchase products and services and process payments received with the intent to promote open and fair conduct in all aspects of the purchasing and receivables process. The Agency is responsible for complying with federal, state and local statutes regulating competitive sealed bids, competitive sealed proposals, professional services, high technology purchases, cooperative purchases, and emergency and sole-source purchases. In addition, the Agency often manages cash in any number of areas including petty cash transactions, receiving cash for permits, receiving cash for copies of reports, receiving cash for other services. The Document Submission Form should list the areas where cash is received by the agency and a written directive on how to handle and document those transactions must be developed. --Copy of written directive(s) that ensure person or position responsible for each cash fund is identified, And --Copy of documentation for transactions, submission, or reconciliation, And --Copy of cash account log, receipts, balance sheet, or ledger, Or --Observation of cash account security, log, and transaction detail. 1.04 Written System of Agency Directives *(core standard)* The agency has a written directive system in place that includes all agency policies, procedures, and practices. The written directive system must: a. Be numbered and organized in a manner that allows numerical reference. b. Require a periodic review and updating of directives to include that all directives are in accordance with applicable Texas Law. c. Require directives and updates be made available to, and reviewed by, all affected agency personnel in a manner designated by the Agency Director. d. Require maintenance of documentation proving receipt of directives by agency personnel in a manner designated by the Agency Director. It is the responsibility of the agency to ensure their written directives are in compliance with applicable Texas Law. In some cities, all policies must be reviewed by the city s attorney. In many cities, this task is left to the Fire Chief. A written statement from the Office of the Agency Director, that departmental written directives comply with all applicable

Texas Law, is required as part of this standard s proof of compliance. This can be a stand-alone letter or memo, or may be included in the written directive that the Chief, or a designee, is responsible for ensuring that all policies and procedures are in compliance with Texas Law. --- Copy of a sample policy, procedure, general order, etc., And --- Statement on DSF about how directives are made available to employees and evidence of that process, And --- Signature sheet or other proof that personnel receive copies or state they have reviewed, And --Some documentation of periodic review of directives, And --Some indication that polices are in compliance with State Law, And --Observation of availability of written directives to all personnel (On-site). 1.05 Agency Jurisdiction *(core standard)* The Agency has written documentation from a unit of government that authorizes the existence of the Agency and defines its jurisdictional boundaries. This is typically an Article within the City Charter or an ordinance passed by the City Council which establishes the agency. The Texas Commission on Fire Protection (TCFP) does not establish an agency. There must be some formal action on the part of a government body creating the agency. --Copy of documents for Agency existence and jurisdiction, could be in City Charter or Ordinance documentation, And --Copy of boundary ordinances or portions of Metes and Bounds book, Or --Copy of map provided to employees with jurisdictional boundaries delineated. 1.06 Firefighter Authority *(core standard)* The Agency has a written directive stating the authority of the firefighter and associated requirements to be a firefighter for that agency. None --Copy of agency directive outlining authority, Or --Copy of city ordinance or charter regarding authority of firefighters, Or --Copy of Texas Local Government Code Chapter 419.

1.07 Authority of the Agency Director *(core standard)* The Agency has written documentation from a unit of government designating the authority of the Agency Director. None --Copy of City Charter or Ordinance giving Director authority over Department, Or --Copy of Chief s letter of appointment, Or --Copy of Chief s job description if approved by Council. 1.08 Duty to Obey Lawful Orders *(core standard)* The Agency has a written directive requiring employees to obey lawful orders from a higherranking member and explaining how to respond to conflicting or unlawful orders. None --Copy of written directive, And --Copy of any Internal Investigations related to failure to obey orders, Or --Copy of any supervisor counseling where officer failed to obey supervisor, Or --Copy of sign-in sheet where officers trained on subject or received copy of policy. 1.09 Sworn Personnel Certification The Agency has a written directive which requires that personnel hold a Texas Commission on Fire Protection and/or State Firemen and Fire Marshal certification before performing fire service duties. --Copy of written directive, And --Copy of firefighter s certification. 1.10 Accounting for Agency Owned Capital Assets This standard may be met by showing copies of the firefighter s certification. The Agency has a written directive for insuring accountability at least annually of all Agency owned capital property, equipment and other assets. Capital assets will be those assets with a value above a limit set by Agency policy. (Example, all items over $5000 in value are capital

items, or other value determined by the Agency or governing body). The inventory results will be forwarded to the Agency Director. Required --Copy of written directive, And --Copy of recent agency asset inventory. 1.11 Approval for Personally Owned Equipment The Agency has a written directive that requires all personnel to obtain written approval from the Agency Director or designee prior to carrying or using any personally owned equipment during the performance of their duties. Agencies which authorize employees to carry or use specific personally owned items in their directives and specifically prohibit any items (weapons, equipment or uniform items) other than those approved in their written directive, are not required to have a written approval process from the Agency Director. Since the Agency Director has already issued a list of personally owned items approved for carry, there is no need for an approval process unless, other items are sometimes allowed. The Agency Director must have control over what equipment and uniform items are carried and worn by the members of the agency. --Copy of written directive, And --Copy of any request or approval of personally owned equipment by the Director, Or --Proof of receipt by officers, Or --Copy of any supervisory counseling or investigation for violating provision. 1.12 Agency Issued Property/Equipment The Agency has a written directive which requires all personnel to sign for any Agency owned property/equipment issued to the employee, and includes a process for recovering the property/ equipment when the employee leaves the Agency. None --Copy of written directive, And --Copy of property sheets for personnel signing for issued property/equipment, And --Copy of property sheets for personnel returning issued property/equipment.

1.13 Strategic Plan/Master Plan The Agency has a three to five-year strategic/master plan that lists the goals, objectives, and timelines of accomplishment of the objectives for the organization. The plan must be have stakeholder input. None --Copy of strategic plan, And --Copy of surveys, meeting notes, etc, with stakeholders, And --Proof of dissemination throughout the Department. 1.14 Fire Department Mission Statement The Agency must have a mission statement that details the department s mission, purpose, and values. None --Copy of Mission Statement, And --Proof of dissemination throughout the Department. 1.15 Administrative Tactical Worksheets The Agency shall develop administrative tactical worksheets to ensure that state, local, and departmental requirements are completed for such processes as hiring of firefighters, promotions, discipline, retirement, apparatus maintenance, equipment maintenance, adding-deleting from inventory control systems, etc. Just as a tactical worksheet for emergency incidents provides a list of reminders to be done during an emergency incident, there are administrative processes where steps could be overlooked and having these worksheets provides a means to better ensure that no requirements are overlooked.

--Copies of Administrative Tactical Worksheets covering a range of typical processes in a fire department. 1.16 Risk Management Program The Agency shall develop a comprehensive risk management program that has a process of identifying, evaluating, prioritizing, and controlling risks which can impact the resources, including personnel and the activities of an organization in order to minimize the detrimental effects on that organization. None --Copy of Risk Management Plan, And --Proof of dissemination throughout the Agency. 1.17 Job Descriptions *(core standard)* The Agency shall have a written description of the general tasks, functions, and responsibilities for each position in the Agency. The job description shall communicate clearly and concisely what responsibilities and tasks the position entails and to indicate the key qualifications of the position. --Copy of job description for each position. 1.18 Succession Planning The Agency must have succession plan identifying what skill and competencies are needed to succeed and define an in depth promotional track approach and training. Succession planning is a process for identifying and developing internal personnel with the potential to fill key leadership positions in the Agency.

--Copy of the Agency s Succession Plan, And --Proof of dissemination throughout the Agency.

CHAPTER 2 EMERGENCY MEDICAL SERVICE *(core standard)* The scope of the Emergency Medical Service (EMS) chapter pertains to the EMS service provided by the fire department and affiliated EMS organizations that provide transport service with the fire department s response area. The level of EMS service provided by the fire department is entirely up to the Authority Having Jurisdiction (AHJ). The Texas Fire Chief s Association Best Practices Committee recognizes that organizations that decided to provide organized EMS service is required to be licensed by the Texas Department of State Health Services (DSHS) as a First Responder Organization (FRO) or EMS Provider. The FRO and EMS provider organizations are required to have a Medical Director, medical protocols, specialized equipment, and state certified EMS personnel and many other requirements to be licensed by DSHS. In all cases for FRO s and EMS provider organizations making application for Best Practices must meet Texas DSHS minimum standards outlined in the current edition of Texas Administrative Code, Title 25 Health Services, Part 1 Department of State Health Services, Chapter 157 Emergency Medical Care. To qualify for Best Practices the AHJ shall, at a minimum, remain in good standing with DSHS. In the event the requesting organization has recent or repetitive DSHS violations the visiting Best Practices assessors shall review reported DSHS infractions and make a judgment of the requesting organizations eligibility for Best Practices. It is the AHJ responsibility to provide all violations up front to the Best Practices Committee during the application process. 2.01 Non-EMS Provider Fire Department does not provide any organized EMS within its response area. AHJ still can achieve Best Practices by training all of its members in CPR and AED to a national standard. AHJ will also be required to provide information on the organized EMS organization that is providing EMS within its response area. --Copy of Agreement that shows what organized EMS organization provides EMS service to the fire departments response area, And --Copy of the current Texas DSHS EMS provider license of the organized EMS organization that is providing EMS within the fire departments response area, And

--Copy of training documentation on all members for CPR and AED training. 2.02 First Responder Provider Fire Department provides an organized First Responder EMS within its response area. First Responder Organization (FRO) that provide EMS are required to have a medical director, medical protocols, specialized equipment, state certified EMS personnel, and have an affiliation with a Texas Licensed EMS provider for transport of patients from incidents. These are just a few of the requirements for FRO by DSHS Rule 157.14. To qualify for Best Practices the AHJ shall, at a minimum, remain in good standing with DSHS. --Copy of current First Responder Organization License issued by Texas DSHS, And --Copy of Agreement that shows what EMS Provider organization that provides EMS service to the fire department s response area, And --Copy of the current Texas DSHS EMS provider license of the EMS organization that is providing EMS transport within the fire departments response area, And --Copy of organization s current members licensed or certified to provide EMS service by DSHS, And --Copy of training documentation on all members for CPR and AED training, And --AHJ has an established process making sure that all specialized equipment is meeting manufacture standards in regards to annual testing, calibrations, and testing to confirm the device is working properly, And --AHJ has as an established periodic analysis of effectiveness of EMS services it provides to look for ways to improve EMS services to its citizens. Note: DSHS First Responder renewal packet for Proof of Compliance can be used, it contains all the information listed and much more. 2.03 EMS Provider Fire Department provides an organized EMS Provider within its response area. EMS Provider that provides EMS transport services are required to have a medical director, medical protocols, specialized equipment, state certified EMS personnel, and EMS units. These are just a few of the requirements for EMS Provider under DSHS Rule 157.11. To qualify for Best Practices the AHJ shall, at a minimum, remain in good standing with DSHS who regulates and inspects the EMS Provider.

--Copy of current EMS Provider License issued by Texas DSHS, And --Copy of organization s current members licensed or certified to provide EMS service by DSHS, And --Copy of mutual aid or inter-local agreement with other EMS provider organizations that may assist the fire department within their response area, And --Copy of organization s license to operate as an EMS Provider, And --Copy of training documentation on all members for CPR and AED training, And --AHJ has an established process making sure that all specialized equipment is meeting manufacture standards in regards to annual testing, calibrations, and testing to confirm the device is working properly, And --AHJ has as an established periodic analysis of effectiveness of EMS services it provides to look for ways to improve EMS services to its citizens. Note: DSHS EMS Provider renewal packet for Proof of Compliance can be used, it contains all the information listed and much more.

CHAPTER 3 TRAINING Fire departments are held accountable both by their community and through various regulating agencies. Employee s actions are guided by clearly written policy, by adequate supervision, and training. The Texas Commission on Fire Protection and State Firemen and Fire Marshal Association prescribes the minimum level of training for both entry into fire department operations and for continuing education after employed. These standards ensure these training mandates are completed and appropriate records are kept to prove the appropriate training was conducted. 3.01 Training Program The fire department has an established training program that is responsible for the compliance, coordination, development, and presentation of training to meet the minimum requirements set out by the department and regulating agencies. The program should insure that all personnel have recurrent hands-on training and evaluation in skills set forth by the TCFP and/or SFFMA for firefighter certification. The program should also include guidelines and requirements for multicompany evolutions. The program must also address regular physical fitness training and participation requirements. This standard requires the department to provide the overall scope of their training program to ensure they are meeting the minimum requirements --Training program SOP, And --List of regulating agencies with minimum requirements, And --Copy of instructor certifications. 3.02 Training Records *(core standard)* The fire department has a written procedure describing their employee training records system. The reporting system must meet guidelines set forth by the associated regulating agency. This system should also include EMS records. There is not set format for a training records system. Each department must maintain a complete set of records, including sign in sheets, for all training conducted or attended by its members. Records must be in an organized manner and easily accessible. --Copy of written procedure, And --Observation of Training files On-Site, And

--Observation of EMS CE. 3.03 Probationary Firefighter Training Program The department has a written Probationary Firefighter Training program for newly hired members. The program must have the following items: a. Require training be signed off by an officer. b. Be divided into phases of training based on departmental needs. c. Require newly certified or inexperienced firefighters to complete all phases of the training program prior to finishing their probationary period. d. Be a minimum of four weeks long. None --Copy of written program, And --Observation training records showing multiple phases and length. 3.04 Probationary Officer Training Program The department has a written officer training program for newly promoted officers. The program must have the following items: a.include categories based on department needs. b.be divided into phases and completed within six months. c.should include a training program for all officer ranks/supervisory levels. None --Copy of written program, And --Copy of training manual showing multiple phases and length. 3.05 In- Service Volunteer Firefighter Training If the Agency has volunteer firefighters, a written directive requires that volunteer receive the same in-service training as regular firefighter full time personnel in the functions that the volunteer firefighters are designated by the Agency to perform. Prior to engaging in firefighting operations, volunteer firefighters must meet the criteria and training requirements set out by the State Firemen s and Fire Marshals Association. None

--Copy of written directive, And --Observation of training records for Volunteer Firefighters. 3.06 EMS Training Program If the department provides EMS or is a first responder organization, the department shall have a written program outlining what is required of personnel by the medical director to operate within the system and what recurrent training is required. Each level of certification shall be outlined with requirements. None --Copy of written program, And --Verification of personnel to be in compliance with the requirements. 3.07 Special Ops Training Program If the department has any special operations programs, a program should be in place to outline the special operations performed by the department, training requirements for team member, and the training requirements to maintain proficiency by personnel. None --Copy of written program, And --Observation of training records for personnel involved in any special operations program. 3.08 Supervisor Training The department provides for continuing education training for all supervisors appropriate to their position/rank on an annual basis. This additional training also applies to all supervisors (not just the initial supervisory rank) and includes non-sworn supervisors. They should be given training "appropriate to their position/rank". Training could include college hours, leadership conferences, the National Fire Academy, etc. Although we recommend formal training, an agency can conduct in-house training sessions as long as the training content is documented and contains sufficient information appropriate to the new rank or position.

--Copy of written program, And --Observation of supervisory training. 3.09 Field Training Officers/EMS Preceptors The department should have an established policy and procedure for field training officers/ems preceptors. The policy should outline what is required to become a FTO/Preceptor and what is required to maintain this status. None --Copy of policy and procedure for outlining requirements. 3.10 Probationary Firefighter Training Evaluations The Agency has a written directive that requires probationary firefighters receive at least monthly evaluations by the probationary firefighter s officer. The evaluation will be reviewed with the new firefighter and the officer, and then filed in the training documents. None --Copy of written directive, And --Observation of at least monthly documented review by new firefighter and officer. 3.11 Required Telecommunication Training *(core standard)* If the Agency operates a communications center, personnel are trained in the operations in accordance with applicable agency requirements and in the procedures of the communications equipment and familiarity with departmental operations. Training in familiarity with department operations may be some form of formal training or by the provision and discussion of a departmental operations manual. --Copy of training program. 3.12 Professional Development

The department should have lined out in policy the requirements for each position in the department. All recognized and/or promoted positions within a department must have minimum requirements and career paths that specify required education and experience and/or preferred classes/courses. None --Copy of policy and procedure for requirements, And --Observation of training records or certificate. 3.13 Assistant Fire Chief Training The Assistant Fire Chief(s) or second in command position(s) of the department have completed or are currently enrolled in advanced supervisory courses. It is also strongly recommended that all Fire Chiefs complete the Texas Fire Chiefs Academy training program. None --Copy of training records or certificate. 3.14 Fire Inspectors, Investigators, and Fire Marshal The department should have an established policy and procedure for inspectors, investigators and the Fire Marshal. The policy should outline what is required to become an investigator, inspector or Fire Marshal and what is required to maintain this status in regards to continuing education, training including TCLOSE requirements (if applicable). None --Copy of policy and procedure for requirements, And --Observation of training records or certificate. 3.15 Training Facilities The department should have access and use of a fire training facility. Departments not owning their own facilities should have an agreement with a certified fire training facility allowing the use of the facility for training purposes. None

--Ownership of a fire training facility, And --Copy of an agreement for use of a fire training facility.

CHAPTER 4 SPECIAL OPERATIONS Scope of Special Operations Sections (Rope Rescue, Confined Space Rescue, Trench Rescue, Structural Collapse Rescue, Swift Water Rescue, Dive Underwater Search/Rescue, and Hazardous Materials Response) The scope of these sections specifically pertains to the special team s training, operational response and equipment compliance and may or may not apply directly to every member of the agency. The section should be read and administered as it applies to the specific special team and not to normal fire department operations. 4.01 Rope Rescue (High Angle / Low Angle) The agency having jurisdiction (AHJ) shall have the capability to safely respond and put in service a trained rope rescue team Or have a mutual aid agreement in place to request a trained rope rescue team for specialized high angle / low angle rescues. This section does not address cave or wilderness rope rescue situations. Although the occurrence of rescues depending on the need for specialized training and equipment is rare for many fire agencies when a specialized rescue does present itself the fire department is called upon to respond. The capabilities of the fire agency and its members must be recognized to perform the rescue safely and efficiently for the benefit of the public and rescuers. In the event that the fire agency does not have any rope rescue capabilities the agency will have provisions or agreements in place to request a neighboring fire agency or regional rope rescue team to assist them, per NFPA 1670, Edition 2009, sections referenced below. NFPA 1670, Edition 2009, section 4.1.1; The authority having jurisdiction (AHJ) shall establish levels of operational capability needed to conduct operations at technical search and rescue incidents safely and effectively, based on hazard identification, risk assessment, training level of personnel, and availability of internal and external resources. NFPA 1670, Edition 2009, section 4.1.3; In jurisdictions where identified hazards might require a search and rescue capability at a level higher than awareness, a plan to address this situation shall be written. NFPA 1670, Edition 2009, section 4.2.1; The AHJ shall conduct a hazard identification and risk assessment of the response area and shall determine the feasibility of conducting technical search and rescue operations, in regards to rope rescue. NFPA 1670, Edition 2009, section 4.2.3, 4.2.4 and 4.2.5; The AHJ shall identify rope rescue internal resources and external resources to augment internal resources to respond to these type of incidents. There shall be a procedure to acquiring external resources for rope rescue.

Proof of Training and Operational Response Compliance: --Copy of written policy/directive on response to High Angle/Low Angle rope rescues, Or --Copy of written policy/directive on requesting High Angle/Low Angle rope rescue team, And --Copy of Mutual Aid Agreement providing request/response of another agency s or regional rope rescue team, then the following items listed below: --AHJ has established guideline for on-scene Accountability of member, while maintaining member s safety. The AHJ should refer to NFPA 1670, Edition 2009, 4.1.12.1 and 4.1.12.2 as a reference in helping establish this guideline, And --AHJ has established guidelines for members to recognize the need for rope rescue and what initial response is needed to maintain member s safety. The AHJ should refer to NFPA 1670, Edition 2009, 5.2.2, in establishing this guideline, And --AHJ has established a guideline for Entrance Requirements. The AHJ should refer to NFPA 1006, Edition 2008, 4.2 Entrance Requirements as a reference in establishing this guideline, And --AHJ has established job performance requirements for members in rope rescue Level I and Level II job performance requirements per NFPA 1006, Edition 2008, Chapter #6 or equivalent training based on AHJ needs assessment, And --Documentation and Training on rope rescue job performance requirements for members will be kept per AHJ standards. The AHJ should refer to NFPA 1670, Edition 2009, 4.1.10 Training through 4.1.10.5 Documentation, as a reference in establishing these guidelines. Proof of Equipment Compliance: --AHJ has life safety rope (rescue rope), harnesses, and hardware that is used for rope rescue that meets NFPA 1983 manufacture standards referenced in NFPA 1500, Edition 2007, 7.16.1, And --AHJ has life safety rope (rescue rope) that is rated for General Use that is designed to hold the weight of two individuals per NFPA 1983 which is referenced in NFPA 1500, Edition 2007, 7.16.2 and 7.16.2.1 and any rope that is not a life safety rope shall be marked in a manner that members can easily recognize it is not to be used for rope rescues or the rope is taken out of service and destroyed, And --AHJ has a guideline on how a life safety rope (rescue rope) is visually and physically inspected before initial usage, annually, and after each use per NFPA 1500, Edition 2007, 7.16.3, 7.16.3.1, 7.16.3.2, and 7.16.4 that meets manufactures criteria that allows reuse of the rope and keeps it in service as a life safety rope. If for any reason the rope does not meet this standard it must be remove from

service as a life safety rope and shall be marked in a manner that members can easily recognize it is not to be used for rope rescuer or the rope is taken out of service and destroyed. Any time a life safety rope is shock loaded it will be taken out of service permanently as a life safety rope, And --AHJ keeps records on life safety rope starting when it was placed in-service, usage, visual and physical inspections confirming the life safety rope is still in-service. Each life safety rope will have its own record that will be maintain while the life safety rope is in service, per NFPA 1500, Edition 2007, 7.16.5, And --AHJ has an established process making sure that all specialized equipment is meeting manufacture standards in regards to annual testing, calibrations, and testing to confirm the device is working properly. 4.02. Confined Space Rescue *(core standard)* The agency shall have the capability to respond to and safely conduct a confined space rescue. The agency shall have a trained confined space rescue team Or have a mutual aid agreement in place to request a trained confined space rescue team for specialized confined space rescues. Although the occurrence of rescues depending on the need for specialized training and equipment is rare for many fire agencies when a specialized rescue does present itself the fire department is called upon to respond. The capabilities of the fire agency and its members must be recognized to perform the rescue safely and efficiently for the benefit of the public and rescuers. In the event that the fire agency does not have any confined space rescue capabilities the agency will have provisions or agreements in place to request a neighboring fire agency or regional confined space rescue team to assist them, per NFPA 1670, Edition 2009, sections referenced below. NFPA 1670, Edition 2009, section 4.1.1; The authority having jurisdiction (AHJ) shall establish levels of operational capability needed to conduct operations at technical search and rescue incidents safely and effectively, based on hazard identification, risk assessment, training level of personnel, and availability of internal and external resources. NFPA 1670, Edition 2009, section 4.1.3; In jurisdictions where identified hazards might require a search and rescue capability at a level higher than awareness, a plan to address this situation shall be written. NFPA 1670, Edition 2009, section 4.2.1; The AHJ shall conduct a hazard identification and risk assessment of the response area and shall determine the feasibility of conducting technical search and rescue operations, in regards to confined space rescue. NFPA 1670, Edition 2009, section 4.2.3, 4.2.4 and 4.2.5; The AHJ shall identify confined space rescue internal resources and external resources to augment internal resources to respond to these type of incidents. There shall be a procedure to acquiring external resources for confined space rescue.

Proof of Training and Operational Response Compliance: --Copy of written policy/directive on response to confined space rescues Or --Copy of written policy/directive on requesting a confined space rescue team And --Copy of Mutual Aid Agreement providing request/response of another agency s or regional confined space rescue team, then the following items listed below: --AHJ has established guideline for on-scene Accountability of member, while maintaining member s safety. The AHJ should refer to NFPA 1670, Edition 2009, 4.1.12.1 and 4.1.12.2 as a reference in helping establish this guideline, And --AHJ has established guidelines for members to recognize the need for confined space rescue and what initial response is needed to maintain member s safety. The AHJ should refer to NFPA 1670, Edition 2009, 7.2.4, in establishing this guideline, And --AHJ has established guidelines for its members entering confined space environment with PPE including SCBA and IDLH detection equipment for confined space rescue or training incidents, And --AHJ has established guideline for staffing and equipping intervention crew to rescue other members during IDLH environments; AHJ should reference NFPA 1500, Edition 2007, 8.8 Rapid Intervention for Rescue Members when developing their guideline, And --AHJ has established a guideline for Entrance Requirements. The AHJ should refer to NFPA 1006, Edition 2008, 4.2 Entrance Requirements as a reference in establishing this guideline, And --AHJ has established job performance requirements for members in confined space rescue Level I and Level II job performance requirements per NFPA 1006, Edition 2008, Chapter #7 or equivalent training based on AHJ needs assessment, And --AHJ has trained members on how to identify confined spaced entry hazards, And --Documentation and Training on confine space rescue job performance requirements for members will be kept per AHJ standards. The AHJ should refer to NFPA 1670, Edition 2009, 4.1.10 Training through 4.1.10.5 Documentation, as a reference in establishing these guidelines. Proof of Equipment Compliance: --AHJ has life safety rope (rescue rope), harnesses, and hardware that is used for rope rescue that meets NFPA 1983 manufacture standards referenced in NFPA 1500, Edition 2007, 7.16.1, And --AHJ has life safety rope (rescue rope) that is rated for General Use that is designed to hold the weight of two individuals per NFPA 1983 which is referenced in NFPA 1500, Edition 2007, 7.16.2 and 7.16.2.1 and any rope that is not a life safety rope shall be marked in a manner that members can easily recognize it is not to be used for rope rescues or the rope is taken out of service and destroyed, And

--AHJ has a guideline on how a life safety rope (rescue rope) is visually and physically inspected before initial usage, annually, and after each use per NFPA 1500, Edition 2007, 7.16.3, 7.16.3.1, 7.16.3.2, and 7.16.4 that meets manufactures criteria that allows reuse of the rope and keeps it in service as a life safety rope. If for any reason the rope does not meet this standard it must be remove from service as a life safety rope and shall be marked in a manner that members can easily recognize it is not to be used for rope rescuer or the rope is taken out of service and destroyed. Any time a life safety rope is shock loaded it will be taken out of service permanently as a life safety rope, And --AHJ keeps records on life safety rope starting when it was placed in-service, usage, visual and physical inspections confirming the life safety rope is still in-service. Each life safety rope will have its own record that will be maintain while the life safety rope is in service, per NFPA 1500, Edition 2007, 7.16.5, And --AHJ has a gas detector that has the minimum detection capabilities of CO, LEL, and Oxygen levels with a guideline that address manufacture maintained standards. This gas detector will be used to identify an IDLH environment during confined space rescue entries, And --AHJ has an established guideline that all members that maybe called upon to wear a SCBA or Air-Respirators will have an annual fit test, meeting NFPA 1500, Edition 2007, 7.12 Fit Testing, And --AHJ has an established process making sure that all specialized equipment is meeting manufacture standards in regards to annual testing, calibrations, and testing to confirm the device is working properly. 4.03 Trench Rescue *(core standard)* The agency shall have the capability to respond to and put in service a trained technical rescue team having the capability/training to perform trench rescue operations Or have a mutual aid agreement in place to request a trained trench rescue team for specialized trench rescue operations. Although the occurrence of rescues depending on the need for specialized training and equipment is rare for many fire agencies when a specialized rescue does present itself the fire department is called upon to respond. The capabilities of the fire agency and its members must be recognized to perform the rescue safely and efficiently for the benefit of the public and rescuers. In the event that the fire agency does not have any trench rescue capabilities the agency will have provisions or agreements in place to request a neighboring fire agency or regional trench rescue team to assist them, per NFPA 1670, Edition 2009, sections referenced below. NFPA 1670, Edition 2009, section 4.1.1; The authority having jurisdiction (AHJ) shall establish levels of operational capability needed to conduct operations at technical search and rescue incidents safely and effectively, based on hazard identification, risk assessment, training level of personnel, and availability of internal and external resources.

NFPA 1670, Edition 2009, section 4.1.3; In jurisdictions where identified hazards might require a search and rescue capability at a level higher than awareness, a plan to address this situation shall be written. NFPA 1670, Edition 2009, section 4.2.1; The AHJ shall conduct a hazard identification and risk assessment of the response area and shall determine the feasibility of conducting technical search and rescue operations, in regards to trench rescue. NFPA 1670, Edition 2009, section 4.2.3, 4.2.4 and 4.2.5; The AHJ shall identify trench rescue internal resources and external resources to augment internal resources to respond to these type of incidents. There shall be a procedure to acquiring external resources for trench rescue. Proof of Training and Operational Response Compliance: --Copy of written policy/directive on response to trench rescues, Or --Copy of written policy/directive on requesting trench rescue team And --Copy of Mutual Aid Agreement providing request/response of another agency s or regional trench rescue team, then the following items listed below: --AHJ has established guideline for on-scene Accountability of member, while maintaining member s safety. The AHJ should refer to NFPA 1670, Edition 2009, 4.1.12.1 and 4.1.12.2 as a reference in helping establish this guideline, And --AHJ has established guidelines for members to recognize the need for trench rescue and what initial response is needed to maintain member s safety. The AHJ should refer to NFPA 1670, Edition 2009, 11.2.3, in establishing this guideline, And --AHJ has established guidelines for its members entering trench environment with PPE including SCBA and Immediately Dangerous to Life or Health (IDLH) detection equipment for trench rescue or training incidents, And --AHJ has established guideline for staffing and equipping intervention crew to rescue other members during IDLH environments; AHJ should reference NFPA 1500, Edition 2007, 8.8 Rapid Intervention for Rescue Members when developing their guideline, And --AHJ has established a guideline for Entrance Requirements. The AHJ should refer to NFPA 1006, Edition 2008, 4.2 Entrance Requirements as a reference in establishing this guideline, And --AHJ has established job performance requirements for members in trench rescue Level I and Level II job performance requirements per NFPA 1006, Edition 2008, Chapter # 8 or equivalent training based on AHJ needs assessment, And --Documentation and Training on trench rescue job performance requirements for members will be kept per AHJ standards. The AHJ should refer to NFPA 1670, Edition 2009, 4.1.10 Training through 4.1.10.5 Documentation, as a reference in establishing these guidelines. Proof of Equipment Compliance:

--AHJ has life safety rope (rescue rope), harnesses, and hardware that is used for rope rescue that meets NFPA 1983 manufacture standards referenced in NFPA 1500, Edition 2007, 7.16.1, And --AHJ has life safety rope (rescue rope) that is rated for General Use that is designed to hold the weight of two individuals per NFPA 1983 which is referenced in NFPA 1500, Edition 2007, 7.16.2 and 7.16.2.1 and any rope that is not a life safety rope shall be marked in a manner that members can easily recognize it is not to be used for rope rescues or the rope is taken out of service and destroyed, And --AHJ has a guideline on how a life safety rope (rescue rope) is visually and physically inspected before initial usage, annually, and after each use per NFPA 1500, Edition 2007, 7.16.3, 7.16.3.1, 7.16.3.2, and 7.16.4 that meets manufactures criteria that allows reuse of the rope and keeps it in service as a life safety rope. If for any reason the rope does not meet this standard must be remove from service as a life safety rope and shall be marked in a manner that members can easily recognize it is not to be used for rope rescuer or the rope is taken out of service and destroyed. Any time a life safety rope is shock loaded it will be taken out of service permanently as a life safety rope, And --AHJ keeps records on life safety rope starting when it was placed in-service, usage, visual and physical inspections confirming the life safety rope is still in-service. Each life safety rope will have its own record that will be maintain while the life safety rope is in service, per NFPA 1500, Edition 2007, 7.16.5, And --AHJ has a gas detector that has the minimum detection capabilities of CO, LEL, and Oxygen levels with a guideline that address manufacture maintained standards. This gas detector will be used to identify an IDLH environment during trench rescue entries, And --AHJ has an established guideline that all members that maybe called upon to wear a SCBA or Air-Respirators will have an annual fit test, meeting NFPA 1500, Edition 2007, 7.12 Fit Testing, And --AHJ has an established process making sure that all specialized equipment is meeting manufacture standards in regards to annual testing, calibrations, and testing to confirm the device is working properly. 4.04 Structural Collapse Rescue The agency shall have the capability to respond to and put in service a trained structural collapse rescue team having the capability/training to perform structural collapse rescue operations Or have a mutual aid agreement in place to request a trained Technical Rescue Team for specialized structural collapse rescue operations. Although the occurrence of rescues depending on the need for specialized training and equipment is rare for many fire agencies when a specialized rescue does present itself the fire department is called upon to respond. The capabilities of the fire agency and its members must be recognized to perform the rescue safely and efficiently for the benefit of the public and rescuers. In the event that the fire agency does not have any structural collapse rescue

capabilities the agency will have provisions or agreements in place to request a neighboring fire agency, regional or state structural collapse rescue team to assist them, per NFPA 1670, Edition 2009, sections referenced below. NFPA 1670, Edition 2009, section 4.1.1; The authority having jurisdiction (AHJ) shall establish levels of operational capability needed to conduct operations at technical search and rescue incidents safely and effectively, based on hazard identification, risk assessment, training level of personnel, and availability of internal and external resources. NFPA 1670, Edition 2009, section 4.1.3; In jurisdictions where identified hazards might require a search and rescue capability at a level higher than awareness, a plan to address this situation shall be written. NFPA 1670, Edition 2009, section 4.2.1; The AHJ shall conduct a hazard identification and risk assessment of the response area and shall determine the feasibility of conducting technical search and rescue operations, in regards to structural collapse rescue. NFPA 1670, Edition 2009, section 4.2.3, 4.2.4 and 4.2.5; The AHJ shall identify structural collapse rescue internal resources and external resources to augment internal resources to respond to these type of incidents. There shall be a procedure to acquiring external resources for structural collapse rescue. Proof of Training and Operational Response Compliance: --Copy of written policy/directive on response to structural collapse rescue, Or --Copy of written policy/directive on requesting structural collapse team, And --Copy of Mutual Aid Agreement providing request/response of other agencies, regional, or state structural collapse rescue team, then the following items listed below: --AHJ has established guideline for on-scene Accountability of member, while maintaining member s safety. The AHJ should refer to NFPA 1670, Edition 2009, 4.1.12.1 and 4.1.12.2 as a reference in helping establish this guideline, And --AHJ has established guidelines for members to recognize the need for structural collapse rescue and what initial response is needed to maintain member s safety. The AHJ should refer to NFPA 1670, Edition 2009, 6.2.2, in establishing this guideline, And --AHJ has established guidelines for its members entering structural collapse environment with PPE including SCBA and IDLH detection equipment for structural collapse rescue or training incidents, And --AHJ has established guideline for staffing and equipping intervention crew to rescue other members during IDLH environments; AHJ should reference NFPA 1500, Edition 2007, 8.8 Rapid Intervention for Rescue Members when developing their guideline, And

--AHJ has established guideline when air-purifying respirators (APRs) and powered airpurifying respirators (PAPRs) can be worn by its members; AHJ should reference NFPA 1500, Edition 2007, 7.8.3.1, 7.8.3.2, 7.11.2 Supplied-Air Respirators and 7.11.3 Full Face-piece Air-Purifying Respirators when developing this guideline, And --AHJ has established a guideline for Entrance Requirements. The AHJ should refer to NFPA 1006, Edition 2008, 4.2 Entrance Requirements as a reference in establishing this guideline, And --AHJ has established job performance requirements for members in structural collapse rescue Level I and Level II job performance requirements per NFPA 1006, Edition 2008, Chapter # 9 or equivalent training based on AHJ needs assessment, And --Documentation and Training on structural collapse rescue job performance requirements for members will be kept per AHJ standards. The AHJ should refer to NFPA 1670, Edition 2009, 4.1.10 Training through 4.1.10.5 Documentation, as a reference in establishing these guidelines. Proof of Equipment Compliance: --AHJ has life safety rope (rescue rope), harnesses, and hardware that is used for rope rescue that meets NFPA 1983 manufacture standards referenced in NFPA 1500, Edition 2007, 7.16.1, And --AHJ has life safety rope (rescue rope) that is rated for General Use that is designed to hold the weight of two individuals per NFPA 1983 which is referenced in NFPA 1500, Edition 2007, 7.16.2 and 7.16.2.1 and any rope that is not a life safety rope shall be marked in a manner that members can easily recognize it is not to be used for rope rescues or the rope is taken out of service and destroyed, And --AHJ has a guideline on how a life safety rope (rescue rope) is visually and physically inspected before initial usage, annually, and after each use per NFPA 1500, Edition 2007, 7.16.3, 7.16.3.1, 7.16.3.2, and 7.16.4 that meets manufactures criteria that allows reuse of the rope and keeps it in service as a life safety rope. If for any reason the rope does not meet this standard must be remove from service as a life safety rope and shall be marked in a manner that members can easily recognize it is not to be used for rope rescuer or the rope is taken out of service and destroyed. Any time a life safety rope is shock loaded it will be taken out of service permanently as a life safety rope, And --AHJ keeps records on life safety rope starting when it was placed in-service, usage, visual and physical inspections confirming the life safety rope is still in-service. Each life safety rope will have its own record that will be maintain while the life safety rope is in service, per NFPA 1500, Edition 2007, 7.16.5, And --AHJ has a gas detector that has the minimum detection capabilities of CO, LEL, and Oxygen levels with a guideline that address manufacture maintained standards. This gas detector will be used to identify an IDLH environment during structural collapse rescue entries, And