CR A-F-A-V-HQQV 3x400D 50 HZ

Similar documents
CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR20-07 A-F-A-E-HQQE 3x400/ HZ

TP /4-A-F-A-BQQE 400D 50HZ

SL S.S.N.51D

SL EX.4.51D

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

Company name: Created by: Phone:

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

CombiBloc Close-coupled centrifugal pumps

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

Lenntech. Tel Fax bar. Multistage Pumps.

MARLOW PUMPS RECIRCULATION

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

A Series. 60 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091

GRUNDFOS END SUCTION PUMPS GRUNDFOS END SUCTION PUMPS

dualarm Vertical In-Line Pumps

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

SECTION STEAM CONDENSATE PUMPS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

CombiPrime Self-priming centrifugal pumps

Specially Designed Waste Water & Sewage Pumps

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Wilo IL Vertical Split-Coupled Inline Pumps

ARBO Chemical pumps SealPro with mechanical seal. Product group 1.1

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

IMMERSIBLE PUMPS FOR INDUSTRY

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

CombiBloc. Close-coupled centrifugal pumps

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Transformer oil coolers BETA & CETA

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

K4RH(X) Solids-Handling Pumps

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

TYPE LF/LC/LCV END SUCTION PUMPS

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

SECTION STEAM CONDENSATE PUMPS

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

KEENER GRINDER PUMPS

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Chemical Pumps Vertical Chemical Pump Type TNP

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Vertical Ring-section Pump WKTB. Type Series Booklet

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Pumps Motors ISO 9001 Company

470 Series Stamped Stainless Steel Pumps

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

TECHNICAL DESCRIPTION

EHH SERIES DRAW THROUGH FAN COILS CFM

Goulds LP3400 Series Low Pulse Fan Pumps

EVMSU - Vertical Multistage Pumps. Product Catalog

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

DUPLEX CONDENSATE TANK SYSTEM

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

Stainless steel centrifugal pumps

GRUNDFOS PLUMBING & HVAC PRODUCTS

Advance Release September 2009

Domestic Pump Condensate Transfer Equipment

Oil burners fuel unit with solenoid valve

ETP Series - Self Priming Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Self-priming centrifugal pumps

Transcription:

GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CR 9-1-1 A-F-A-V-HQQV Product No.: 9612486 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. The pump head and base are in cast iron all other wetted parts are in stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via DIN flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. Further product details The product carries the Grundfos Blueflux label. It represents the best from Grundfos within energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or exceed legislative requirements such as the EuP IE3 grade. Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. 1/9

The motor stool connects the pump head and motor. The pump head has a combined 1/2" priming plug and air vent screw. The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: FKM (fluorocarbon rubber) FKM has excellent resistance to oils and chemicals. Above 9 C, FKM should only be used in media without water. The shaft seal is retained in the pump head by a cover and screws. It can be replaced without removing the motor. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The base is made of cast iron. Both the suction and the discharge side of the base have two pressure gauge tappings. The pump is secured to the foundation by four bolts through the base plate. The flanges are fastened to the base by means of locking rings. Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with free-hole flange (FF). Motor mounting designation in accordance with IEC 634-7: IM B 5 (Code I) / IM 31 (Code II). Electrical tolerances comply with IEC 634. 2/9

Position Qty. Description The motor efficiency is classified as IE3 in accordance with IEC 634-3. The motor has thermistors (PTC sensors) in the windings in accordance with DIN 4481/DIN 4482. The protection reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. Thermal switches must be connected to an external control circuit in a way which ensures that the automatic reset cannot cause accidents. The motors must be connected to a motor-protective circuit breaker according to local regulations. The motor can be connected to a variable speed drive for adjustment of pump performance to any duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in Win-/WebCAPS. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing: Impeller: Water 253.. 363 K 293 K 998.2 kg/m³ 2919 rpm 9 m³/h 13.9 m HQQV CE,TR ISO 996:1999 Annex A Cast iron EN-JS15 ASTM 8-55-6 Stainless steel DIN W.-Nr. 1.431 AISI 34 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 16 bar / 9 C 16 bar / -2 C Flange standard: DIN Pipe connection: DN 1 Pressure stage: PN 16 Flange size for motor: FF265 Electrical data: Motor type: 132SC IE Efficiency class: IE3 Number of poles: 2 Rated power - P2: 5.5 kw Power (P2) required by pump: 5.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-415 D V Rated current: 11 A Starting current: 18-118 % Cos phi - power factor:,87-,82 3/9

Position Qty. Description Rated speed: 292-294 rpm Efficiency: IE3 89,2% Motor efficiency at full load: 89,2-89,2 % Motor efficiency at 3/4 load: 9,-89,8 % Motor efficiency at 1/2 load: 89,6-88,4 % Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 17 kg Gross weight: 14 kg Shipping volume:.47 m3 4/9

9612486 CR 9-1-1 5 Hz H [m] CR 9-1-1, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 25 1 2 8 15 6 1 4 5 2 1 2 3 4 5 6 7 8 9 1 11 12 Q [m³/h] P [kw] NPSH [m] 6 P1 12 5 P2 1 4 8 3 6 2 4 1 2 5/9

Description Value Product name: CR 9-1-1 A-F-A-V-HQQV Product No: 9612486 EAN number: 573967399 H [m] 25 CR 9-1-1, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 1 Technical: Speed for pump data: 2919 rpm Rated flow: 9 m³/h Rated head: 13.9 m Head max: 26.4 m Impellers: 1 Impeller reduc.: 1 Shaft seal: HQQV Approvals on nameplate: CE,TR Curve tolerance: ISO 996:1999 Annex A Pump type: CR 9 Stages: 1 Pump version: A Model: A Materials: Pump housing: Impeller: Material code: Code for rubber: Cast iron EN-JS15 ASTM 8-55-6 Stainless steel DIN W.-Nr. 1.431 AISI 34 A V 2 15 1 5 2 4 6 8 1 P [kw] 4 2 PN16 8 x ø18 ø22 ø18 ø156 ø1 45 4 x ø14 28 Q [m³/h] P1 P2 348 8 6 4 2 NPSH [m] 1 5 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 16 bar / 9 C 16 bar / -2 C Flange standard: DIN Connect code: F Pipe connection: DN 1 Pressure stage: PN 16 Flange size for motor: FF265 134 22 571 391 3 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 4482 14 199 261 38 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253.. 363 K 293 K 998.2 kg/m³ Electrical data: Motor type: 132SC IE Efficiency class: IE3 Number of poles: 2 Rated power - P2: 5.5 kw Power (P2) required by pump: 5.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-415 D V Rated current: 11 A Starting current: 18-118 % Cos phi - power factor:,87-,82 Rated speed: 292-294 rpm Efficiency: IE3 89,2% Motor efficiency at full load: 89,2-89,2 % Motor efficiency at 3/4 load: 9,-89,8 % Motor efficiency at 1/2 load: 89,6-88,4 % Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Motor protec: PTC +T +T +T TO AMPLIFIER RELAY L1 L2 L3 +T +T +T TO AMPLIFIER RELAY L3 L2 L1 6/9

Description Motor No: Value 85U17417 Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 17 kg Gross weight: 14 kg Shipping volume:.47 m3 7/9

9612486 CR 9-1-1 5 Hz 22 134 571 391 3 PN16 8 x ø18 14 ø156 ø18 ø22 199 45 ø1 4 x ø14 261 28 38 348 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 8/9

9612486 CR 9-1-1 5 Hz +T +T +T TO AMPLIFIER RELAY +T TO AMPLIFIER RELAY L1 L2 L3 +T +T L1 L2 L3 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 4482 Note! All units are in [mm] unless others are stated. 9/9

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89