Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Similar documents
Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Gas cylinder scale Model GCS-1

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

OPTIBAR P 1010/2010 C Supplementary instructions

Druck DPI 705/DPI 705 IS Series

LOW PRESSURE Intrinsically Safe Transducer AST44LP

U5700 Submersible Liquid Level Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

M5800 Pressure Transducer with Rotatable Display

M7100 Pressure Transducer

Model 144H. Product Data Sheet , Rev DB February Content

U5300 Industrial Pressure Transducer

Model 144H. Product Data Sheet , Rev DB February Content

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

M5200 Industrial Pressure Transducer

OPTIBAR DP 7060 Supplementary Instructions

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

PEPPERL+FUCHS GmbH

Technical Data. Dimensions

D5100 Industrial Differential Pressure Transducer

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

INSTRUCTION MANUAL (ATEX / IECEx)

M5800 Pressure Transducer with Rotatable Display

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Technical Data. Dimensions

D5100 Industrial Differential Pressure Transducer

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Beck. The differential pressure transmitter for air

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Technical Data. General specifications. Rated operating distance s n 5 mm

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

OilSET-1000 (12 VDC)

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

4) Intrinsic Safety Certification

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Technical Data. Dimensions

Technical Data. Dimensions

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Annubar Flowmeter Series

Safety instructions VEGAPULS 64

Rosemount 752 Fieldbus Remote Indicator

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Rosemount 2090P Pulp and Paper Pressure Transmitter

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Operating Instructions Edition 02/2007

Safety vacuum drying oven for flammable solvents

SITRANS Pressure transmitter SITRANS LH300 (7MF1575..) Transmitter for hydrostatic level Compact Operating Instructions

Rosemount 4500 Hygienic Pressure Transmitter

Inductive slot sensor

OPTIWAVE X500 Supplementary Instructions

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Ultrasonic Level Measurement nivopuls FDU 10 S

INSTRUCTION & SERVICE MANUAL

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

DB5 Intrinsically Safe Sounder Type DB-5

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

SET-2000 Hi Level/Oil

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

SET-2000 Oil/Sludge 12 VDC

Operating Manual MS220KA and MSR220KA

U5600. Wireless Pressure Transducer SPECIFICATIONS

Absolute and Gage Pressure Transmitter

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Electronic Pressure Digest. Pressure and Temperature Transmitters

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Sanitary Pressure Transmitter

MSP300 Pressure Transducer

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Vacuum in the laboratory. products and solutions

SET Installation and Operating Instructions. Level switch for one sensor

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

PROTECT SRB 200EXi-1A

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Configurable Pressure Transducer Model FP Issue 1. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

OPTISENS TUR 2000 Technical Datasheet

Software Version 2.01 LEVEL MONITOR MODEL 220

VERSAFLOW VORTEX Supplementary instructions

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

UL HAZARDOUS LOCATIONS SERVICES

MSP340 Pressure Transducer

Transcription:

Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description - pressure sensors Industrial Heavy Duty are top of the range products in Ex - pressure gauge technology. The intrinsically safe Ex - pressure sensors are designed for zone 1 (optional mount on Zone 0) and have special type approval for use in potentially explosive atmospheres and a CENELEC certificate according to the ATEX certification. The measuring ranges, graded in accordance with EN, range from 100 mbar to the maximum pressure range of 1000 bar. The case and wetted parts comprise stainless steel and are thus resistant to chemically aggressive media. The pressure connection and measuring element are welded together, making the measuring system particularly resistant to mechanical shock or vibration. The pressure connection is fitted with a G ½ male thread. Several electrical connections can be obtained to pick up the electrical output signal. The front flush pressure diaphragm avoids zones, in which medium could crystallize or residues could form The field case design enables use in aggravated operation conditions. The Ex - pressure sensors Industrial Heavy Duty meet the electronic magnetic compatibility (EMC) requirements to EN 61326. Features intrinsically safe, zone 1 option: build to zone 0 high long-term stability high accuracy finely graded selection of nominal pressure ranges according to EN corrosion resistant stainless steel design good repeatability high overload protection for dynamic and static measurements simple installation ATEX certficate Measuring ranges High pressure Negative -1...0 bar to -0,1...0 bar Positive 0...0,1 bar to 0... 1000 bar Absolute pressure 0...0,25 bar to 0... 16 bar Applications Chemical and pharmaceutical industry, food industry and environmental technology, process engineering. Model: PEX10, PEX11, PEX13, PEX14 tecsis GmbH DE 770 b Carl-Legien Str. 40 D-63073 ffenbach / Main Sales national Sales international e-mail: info@tecsis.de p. 1 / 4 Tel.: +49(0) 69 / 5806-0 Fax: +49(0) 69 / 5806-170 Fax: +49(0) 69 / 5806-177 Internet: www.tecsis.de

Technical data Model PEX10 PEX11 PEX13 PEX14 Type Standard with internal diaphragm Standard with front flush diaphragm Field case with internal diaphragm Field case with front flush diaphragm Pressure type negative / positive / high pressure absolute pressure 3 ) utput signal 4...20 ma - 2- wire system Accuracy % of F.S. ) 0,5 (option 0,25 BFSL) 0,25 (option 0,125 BFSL) 2 ) Measuring ranges acc. to EN 2 ) 0... 0,1 bar 2 ) 0... 0,1 bar 0... 0,1 bar 0... 0,1 bar to to to to 0... 1000 bar 0... 600 bar 0... 1000 bar 0... 600 bar Repeatability ± 0,05 % of F.S. Stability (annual) ± 0,2 % of F.S. in rated conditions Case stainless steel 1.4571 Process connection G ½ B acc. EN 837 option: G ¼ B, ½ to 1,6 bar G 1 B; from 2,5 bar G ½ B G ½ B acc. EN 837 option: G ¼ B, ½ to 1,6 bar G 1 B; from 2,5 bar G ½ B NPT, ¼ NPT NPT, ¼ NPT Wetted parts stainless steel stainless steel, NBR stainless steel stainless steel option Hastelloy C4 option Hastelloy C4 -ring option FPM, EPDM option FPM, EPDM verload limit 16 bar 3,5-fold; 600 bar 2-fold; > 600 bar 1,5-fold; vacuum proof Electr. connection and plug acc. to DIN EN 175301-803 A with junction box ( PG 9 ), IP 65 protection type acc. to EN 60 529/IEC529 option: plug acc. to DIN EN 175301-803 A with junction box ( PG13,5 ), IP 65 for ship approval) round connector 4-pin M12x1, IP 67 MIL-plug 6-pin round connector M 16x0,75 5-pin cable outlet IP 67 with 1,5 m cable with inner ventilation cable outlet IP 68 with 1,5 m cable with inner ventilation (zero / span adjustable) cable outlet IP 68 with 1,5 m cable with inner ventilation (zero / span not adjustable) Power supply 10... 30 VDC ( field case 11... 30 VDC ) Power consumption signal current Power PI 1W (750 mw with approval for Categrory 1D) Load standard R A[ ] (U B[V]-10V)/0,02A - ( 0,14[ ] x cable length in [m] ) Load field case R A[ ] (U B[V]-11V)/0,02A Test circuit signal R A[ ] < 15 max. load Temperature comp. Range 0... 80 C Temperature influence 4 ) 0,2 % /10 K on zero and span Adjustability Zero and span up to ± 10% Response time 1 ms (within 10 % to 90 % of. F.S.) Protection type IP 65 acc. to EN 60 529/IEC 529 CE-certification 89/336/EWG, interference emission and immunity see EN 61326, interference emission limit class A and B, ATEX EN 50014 (general part), EN 50 020 (instrinsic safety), EN 50 284 (Zone 0), EN 50 281-1 (dust-ex), EN 50303 (mining industry) HF immunity 10 V/m Burst 2 KV Electrical protection types reverse polarity protection Explosion proof protection type ATEX EEx ia I / IIC T4-T6 (BVS 08 ATEX E 067 X) 5) category 1G, 1/2G, 2G, 1D, 1/2D, 2D, M1, M2 Temperature ranges - storage -30... 105 C - media -20... 80 C 6) - ambient -20...80 C 6) Weight ca. 0,2 kg of.f.s.= of Full Scale 1 ) Terminal point adjustment according to DIN 16 086, including non-linearity and hysteresis, zero point and full scale deviation 2 ) 0,25% accuracy only for ranges 0,25 bar 3 ) Absolute pressure from 0,25 bar to 16 bar 4 ) Tk zero point < 0,4 % /10 K; for measuring ranges 0...0,1 and 0...0,16 bar 5 ) Application conditions and safety data see listing acc. to EC Type Test certificate (BVS 08 ATEX E 067 X) 6 ) ther temperature range, see listing acc. to EC Type Test certificate DE 770 b p. 2 / 4

21 Dimensions (mm) Case 21 Min.10.5 10 20,5 31 Plug acc. to DIN EN 175301-803 A IP 65 Plug acc. to DIN EN 175301-803 A for ship approvals IP 65 Cable outlet, IP 67 Round connector, 4-pin M12 x 1, IP 67 MIL-plug, IP 67 3 20 3 10 Round connector, 5-pin M16 x 0,75, IP 67 Cable outlet with access 16,5 +1 Min.9,5 Min. 14.5 13 2 2 to zero and span Potentiometer, IP 68 Cable outlet without access to zero and span Potentiometer, IP 68 Field case with internal spring clip terminal, conductor outer diameter 7-13 mm, IP 68 Pressure connection internal diaphragm Pressure connection front flush diaphragm 27 27 5 9,5 27 18-0,1 G1/2 18,5 x 23,9 x 1,5 15 x 2 20,5 10,5 41 30-0,1 G1 B 29,7 x 35,7 x 2,0 26 x 2 6 G1/4 A-016 A-012 17,5 A-007 G1/2 Screw-in aperture internal diaphragm A-006 Weld-on adapter front flush diaphragm 24,5 +1 19-0,5 0.1 A G1/2 (DIN 16288) 13-0,5 0.1 A G1/4 0.1 A 15-0.2 50 21.3-0,2 G1/2 19.4 +0.1 0.1 A 15-0.2 Min.10.5 50 33.5-0.2 G1 30.5 +0.1 7 A A 5,5 18.2 +0.1 A 30.1 +0.1 A S-002 S-004 S-001 S-003 DE 770 b p. 3 / 4

Electrical connection Two-wire system Plug to DIN 43 650 Cable outlet Field case braun brown 1 3 2 grün green E-001 E-015 Mil-plug PT 02 E-10-6P 4-pin round connector M 12 x 1 5-pin round connector M 16 x 0,75 F A B E C D 4 3 1 2 4 3 2 5 1 E-033 Ex-Zone (in comparison ATEX and CSA) Flammable material Present continuously Flammable material Present intermittently Flammable material Normally not present ATEX Zone 0 (Zone 20 dust) Zone 1 (Zone 21 dust) Zone 2 (Zone 22 dust) CSA Zone 0 Zone 1 Zone 2 Division 1 Division 2 ther details 1. Model 2. Measuring range 3. ptions 4. Ex-Zone ATEX Group Above ground Gases and vapours IIA / IIB / IIC I Dusts Fibres CSA Class II III Group A / B / C / D / E / F / G Modifications reserved DE 770 b p. 4 / 4

Force Pressure Temperature Switch - High pressure sensors Ex ia I / IIC T6 acc. to ATEX Accuracy: 0,5 % Standard output: 4...20 ma; 2-wire system Description Features - pressure sensors Industrial Heavy Duty are top of the range products in Ex - pressure gauge technology. The intrinsically safe Ex - pressure sensors are designed for zone 1 (optional mount on Zone 0) and have special type approval for use in potentially explosive atmospheres and a CENELEC certificate according to the ATEX, additionally accreditation according. The measuring ranges range from 0...1600 bar to the maximum pressure range of 0...8000 bar. The case and wetted parts comprise stainless steel and are thus resistant to chemically aggressive media. The pressure connection and measuring element are up tightened via a metal cone. Therefore there is no risk of leakage in the welding seams. intrinsically safe, zone 1 option: build to zone 0 high long-term stability high accuracy finely graded selection of nominal pressure ranges according to EN corrosion resistant stainless steel design good repeatability high overload protection for dynamic and static measurements simple installation ATEX certficate A relief bore ensures a defined escape for the media in direction of the pressure connection in case of damage. Several electrical connections can be obtained to pick up the electrical output signal. The field case design enables use in aggravated operation conditions. Measuring ranges High pressure Positive 0...1600 bar to 0... 8000 bar Applications Pressure sensors Industrial Heavy Duty meet the electronic magnetic compatibility (EMC) requirements to EN 61326. Process engineering, plant engineering and construction, Chemical and pharmaceutical industry Model: PEX15 tecsis GmbH DE 772 Carl-Legien Str. 40 D-63073 ffenbach / Main Sales national Sales international e-mail: info@tecsis.de p. 1 / 4 Tel.: +49(0) 69 / 5806-0 Fax: +49(0) 69 / 5806-170 Fax: +49(0) 69 / 5806-177 Internet: www.tecsis.de

Technical data Model PEX15 Type Standard with internal diaphragm Field case with internal diaphragm Pressure type positive pressure utput signal 4...20 ma - 2-wire Accuracy % of F.S. 1 ) 0,5 (option 0,25 BFSL) Measuring ranges acc. to EN 0... 1600 bar 0... 2500 bar 0... 4000 bar 0... 5000 bar 0... 6000 bar 0... 7000 bar 0... 8000 bar Repeatability ± 0,05 % of F.S. Stability (annual) ± 0,2 % of F.S. in rated conditions Case stainless steel 1.4571 Process connection M16x1,5 female 9/16 --18UNF F250-C female M20 x 1,5 female Wetted parts stainless steel verload limit 5000 bar 1,2 x; > 5000 bar 1,1 x; Electr. connection and Plug acc. to A with Field case with internal diaphragm IP68 protection type acc. to EN 60 529/IEC529 cable outlet ( PG 9 ), IP 65 ption: Round connector 4-pin M12x1, IP 67 Cable outlet IP 67 with 1,5 m cable with inner ventilation Power supply 10... 30 VDC ( field case 11... 30 VDC ) Power consumption signal current Power PI 1W (750 mw with approval for Categrory 1D) Load standard R A[ ] (U B[V]-10V)/0,02A - ( 0,14[ ] x cable length in [m] ) Load field case R A[ ] (U B[V]-11V)/0,02A Test circuit signal R A[ ] < 15 max. load Temperature comp. Range 0... 80 C Temperature influence 0,2 % /10 K on zero and span Adjustability Zero and span up to ± 10% Response time 1 ms (within 10 % to 90 % of. F.S.) Protection type IP 65 acc. to EN 60 529/IEC 529 CE-certification 89/336/EWG, interference emission and immunity see EN 61326, interference emission limit class A and B, ATEX EN 50014 (general part), EN 50 020 (instrinsic safety), EN 50 284 (Zone 0), EN 50303 (mining industry) HF immunity 10 V/m BURST 2 KV Electrical protection types Protected against reverse polarity and short circuiting on the instrument side Explosion proof protection type ATEX EEx ia I / IIC T4-T6 (BVS 08 ATEX E 067 X) 2) category 1/2G, 2G, M1, M2 Temperature ranges - storage -30... 105 C - media -20... 80 C 3) - ambient -20... 80 C 3) Weight ca. 0,3 kg of.f.s.= of Full Scale 1 ) Terminal point adjustment acc. to IEC 61298-2, including non-linearity and hysteresis, zero point and full scale deviation 2 ) Application conditions and safety data see listing acc. to EC Type Test certificate (BVS 08 ATEX E 067 X) 3 ) ther temperature range, see listing acc. to EC Type Test certificate DE 772 p. 2 / 4

Dimensions (mm) Plug DIN EN 175301-803 A IP65 Round connector M12 x 1 IP67 Cable outlet IP67 Field case IP68 Pressure connection 9/16 18 UNF M16 x 1,5 female M20 x 1,5 DE 772 p. 3 / 4

Electrical connection 2-wire Plug DIN EN 175301-803 A Cable outlet braun brown 1 3 2 grün green E-001 E-015 4-pol. round connector M 12 x 1 Field case 4 3 1 2 E-033 Ex-Zone (in comparison ATEX and CSA) Flammable material Present continuously Flammable material Present intermittently ATEX Zone 0 Zone 1 Zone 2 CSA Zone 0 Zone 1 Zone 2 Division 1 Division 2 Flammable material Normally not present ATEX Group Strip mining Gases and vapours IIA / IIB / IIC I Dusts Fibres CSA Class Mining Gas/Dusts I ID/IIF II III Group A / B / C / D / E / F / G ther details 1. Model 2. Measuring range 3. ptions 4. Ex-Zone Modifications reserved DE 772 p. 4 / 4

Force Pressure Temperature Switch Pressure sensors for explosion hazardous areas Ex d II C T4 T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0.5 % (0.25% BFSL) Standard output: 4...20 ma; 2-wire system 1 5VDC; 3-wire system 0.5 4.5VDC; 3-wire system 0 10VDC; 3-wire system Description The encapsulated explosion-proof pressure sensors are leading-edge products among -approved sensors. The new pressure sensors with pressure-tight encapsulation have design approval according to ATEX II 2 G Ex d II C. The measuring ranges stepped in line with the European standard extend from 0.4 bar up to the top pressure range of 1,000 bar. The housing and parts that come into contact with the measuring medium are made from stainless steel and are therefore resistant to chemically aggressive measuring substances. The pressure connection and measuring cell are welded together. This makes the measuring system exceptionally resistant to the influence of mechanical shock or vibrations. Available as standard signal is a 4-20mA current loop in a 2-wire system. ptionally available are voltage outputs in a 3-wire system such as 1-5 V, 0-10 V or 0.5-4.5 V. The pressure connection with type PEX 17 has a G ½ B external thread as standard. The front-flush version PEX18 avoids dead space in which measuring medium can crystallize out or form residue. These industrial heavy duty pressure sensors conform to the electromagnetic compatibility requirements (EMC) of EN 61326. Features ATEX approved II 2G Ex d II C For dynamic and static measurements High long-term stability High overload protection Finely graded selection of nominal pressure ranges according to EN Corrosion resistant stainless steel design Good repeatability Measuring ranges Gauge pressure Negative -1...0 bar to -0.4...0 bar Positive 0...0.4 bar to 0... 1,000 bar Absolute pressure 0...0.4 bar to 0... 16 bar Applications Gas pressure measurement il drilling platforms / pipelines Refineries / Petrochemical industry Borehole monitoring Model: PEX17, PEX18 tecsis GmbH DE 719 Carl-Legien Str. 40 09/2010 D-63073 ffenbach / Main Sales national Sales international e-mail: info@tecsis.de Tel.: +49(0) 69 / 5806-0 Fax: +49(0) 69 / 5806-170 Fax: +49(0) 69 / 5806-177 Internet: www.tecsis.de p. 1 / 4

Technical data Model PEX17 PEX18 Type Standard with internal diaphragm Standard with front flush diaphragm Pressure type negative / positive / high pressure absolute pressure 2) 4...20 ma 2- wire system utput signal 1 5VDC Low Power, 3-wire system 0 10 VDC 3-wire system 0.5 4.5VDC Low Power, 3-wire system Accuracy % of F.S. 1) 0.5 (option 0.25 BFSL) Measuring ranges acc. to EN 0... 0.4 bar 0... 0.4 bar to 0... 1,000 bar to 0... 600 bar Non-Repeatability ± 0.1 % of F.S. Stability (annual) ± 0.2 % of F.S. in rated conditions Case stainless steel Process connection G ½ B acc. EN 837 G ¼ B ½ NPT 0 1.6 bar G 1 B; 2.5 bar G 1/2 B ¼ NPT Wetted parts stainless steel >25 bar Elgiloy stainless steel -Ring NBR -ring ption FPM, EPDM verload limit 16 bar 3.5-fold; 600 bar 2-fold; > 600 bar 1.5-fold; vacuum proof Electr. connection and Conduit IP 67 with 6ft cable protection type acc. to EN 60 529/IEC529 10... 30 VDC with signal output 4 20 ma, 2-wire Power supply 6... 30 VDC with signal output 1 5 VDC, 3-wire 14... 30 VDC with signal output 0 10 VDC, 3-wire 5... 30 VDC with signal output 0.5 4.5 VDC, 3-wire Power consumption 4 20 ma 2-wire, signal current 4 20 ma 2-wire system R A[ ] (U B[V]-10V)/0.02A Load standard 1 5 VDC 3-wire system R A[ ]>10k 0 10 VDC 3-wire system R A[ ]>10k 0.5 4.5 VDC 3-wire system R A[ ]>5k Temperature comp. Range 0... 80 C Temperature influence 4 ) 0.2 % /10 K on zero and span Response time 1 ms (within 10 % to 90 % of. F.S.), 10 ms at medium temperatures below -30 C for pressure ranges up to 25 bar or with flush diaphragm Protection type IP 67 acc. to EN 60 529/IEC 529 89/336/EEC emission (class B) and immunity according to EN 61326 CE-certification Pressure equipment directive 97/23EC Directive ATEX 94/9/EC HF immunity Burst Wiring protection 10 V/m 4 KV Sig+ towards UB- UB+ towards UB- EX d II c T4-T6 Explosion proof protection type ATEX Temperature ranges - storage -30... 105 C ( -40... 105 C optional) - media -30... 100 C ( -40... 105 C optional) - ambient -30... 100 C ( -40... 105 C optional) Weight ca. 0.2 kg 3) of.f.s.= of Full Scale 1) 2) 3) Terminal point adjustment according to IEC 61298-2, including non-linearity and hysteresis, zero point and full scale deviation Absolute pressure from 0,4 bar to 16 bar Application conditions and safety data see listing acc. to EC Type Test certificate (KEMA 10ATEX0099 X) DE 719 p. 2 / 4

21 Dimensions (mm) Case 21 10 20,5 31 Min.10.5 Pressure connection internal diaphragm Pressure connection front flush diaphragm Weld-on adapter front flush diaphragm 27 18-0,1 G1/2 10 18,5 x 23,9 x 1,5 15 x 2 A-016 20,5 10,5 41 30-0,1 G1 B 29,7 x 35,7 x 2,0 26 x 2 A-012 0.1 A 15-0.2 50 21.3-0,2 G1/2 19.4 +0.1 18.2 +0.1 A 0.1 A 15-0.2 Min.10.5 50 33.5-0.2 G1 30.5 +0.1 30.1 +0.1 A S-004 S-003 DE 719 p. 3 / 4

Electrical connection Two-wire system Three-wire system Cable outlet Cable outlet red (1) UB red (1) black (2) S+ brown (2) black (3) Modifications reserved DE 719 p. 4 / 4

Force Pressure Temperature Switch - Pressure Sensors EEx ia I / IIC T6 according to ATEX with internal diaphragm for submersible pressure measurement accuracy 0.25% and 0.5 % standard output: 4...20 ma; 2-wire system Description -pressure sensors Industrial Heavy Duty are top of the range products in Ex-pressure gauge technology. The intrinsically safe Ex-pressure sensors are designed for zone 0 and have special type approval for use in potentially explosive atmospheres and a CENELEC certificate according to the new ATEX. Due to the systematic use of high-grade stainless steel for the wetted parts, this sensor is suitable for aggressive media. For measuring tasks in aggressive media a special version with PTFE cable can be obtained. A hermetically sealed stainless steel case allows the pressure sensor to be immersed down to a depth of 300 m. The inner vented connection cable makes pressure compensation of the measuring cell against the atmosphere possible and thus hydrostatic pressure measurement. The mechanical fastening of the pressure sensor does not require any additional strain relief, as the construction of the cable is suitable to take a maximum tensile force of 1000 N. An additional weight can be screw-fitted to increase the actual weight of the sensor. The pressure sensors special meet the electronic magnetic compatibility (EMC) requirements to EN 61326. Features intrinsically safe, zone 0 finely graded selection of nominal pressure ranges according to EN high long-term stability high accuracy corrosion resistant stainless steel design good repeatability high overload protection for dynamic and static measurements simple installation CENELEC-certificate acc. to ATEX Measuring ranges gauge pressure positive 0...0.1 bar to 0...25 bar Applications Level measurement in explosive atmosphere Model: E130., E131. tecsis GmbH Carl-Legien Str. 40 D-63073 ffenbach / Main Sales National Sales International e-mail: info@tecsis.de Tel.: +49(0) 69 / 5806-0 Fax: +49(0) 69 / 5806-170 Fax: +49(0) 69 / 5806-177 Internet: www.tecsis.de DE 724 e S. 1/4

Technical data Model E130. E131. Pressure type positive gauge pressure utput signal 4...20 ma - 2-wire system Accuracy % of F.S. 1) 0.5 0.25 Measuring ranges acc. to EN 0... 0.1 bar to 0... 25 bar 0... 0.25 bar to 0... 25 bar Repeatability ± 0.05 % of F.S. Stability (annual) ± 0.2 % of F.S. in rated conditions Pressure connection G ½ B with protection cap Wetted parts - case stainless steel 1.4571 - diaphr. + pressure connect. stainless steel 1.4571 - protection cap stainless steel 1.4571 - cable PUR (option: PTFE up to 10 bar) - shrink hose Polyolefin (not for PTFE cable) ver load limit 1.6 bar 5-fold; >1.6 bar 3.2-fold Electrical connection cable with inner ventilation, tensile strength max. 1000 N Protection type IP 68 according to EN 60 529/IEC529 (depth up to 300 m) Power supply 10...30 VDC Power consumption signal current Load R A[ ]< (U B[V] 10 V) / 0.02 A (0.14 x cable length in m) Temperature comp. range 0...50 C Temperature influence 2 ) 0.2 % /10 K on zero and span Response time 1 ms (within 10 % to 90 % of F.S.) Emission 3) according to EN 61326 Interference 3) according to EN 61326 HF immunity 10 V/m (option: 30 V/m) Burst 4 KV Electrical protection types Reverse polarity protection Explosion proof protection type EEx ia I / IIC T6 (DMT 02 ATEX E 114 X) max. values DMT - power supply <30 VDC - short circuit current 100 ma - power restriction 4) 1 W - media temperature -10... 60 C - ambient temperature -10... 60 C - storage temperature -10... 60 C - internal capacity 22 nf + 0.2 per m cable - internal inductivity 100 H + 2 per m cable Weight - sensor 0.20 kg - cable 0.08 kg per m cable - additional weight 0.50 kg 1) Terminal point adjustment according to DIN 16 086, including linearity and hysteresis 2) 0.4 % /10 K for measuring ranges 0...0.1 and 0...0.16 bar 3) Declaration of conformity on request 4) Power limitation for supply transformers of F.S. = of full scale value DE 724 e p. 2/4

18 18 10 10 130 147 Dimensions (mm) ption: PTFE cable 27 27 G1/2B G1/2B Electrical connection Two-wire system brown V / S- green shield blue E-024 DE 724 d S. 3/4

Accessories To increase the actual weight of the sensor an additional weight can be screw-fitted. Article-no. AZM51X001001 rder details: 1. Model 2. Measuring range 3. ptions 4. Cable length 5. Ex-zone DE 724 e p. 4/4