White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

Similar documents
Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

A Powerful Case for Infrared Windows

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

Infrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Arc Flash Protection Training - NFPA 70e Electrical Safety

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

White paper. OSHA and NFPA 70 Safer by Design The History of IRISS. Infrared Windows. Abstract: iriss.com

CAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:

Electrical Safety Compliance: NFPA 70E

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Predictive Maintenance Training

INFRARED WINDOW SERIES

NFPA 70E Elevates Safety. with Heightened Risk Awareness

VPFR. cma. Product Brochure. Industrial-Grade Infrared Inspection Viewing Panes

NFPA 70E Electrical Safety & Arc Flash Training

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

Common Misconceptions Relating to Infrared Inspection Ports

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

infrared inspections efficient solutions. focused results.

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com

Your Turnkey Solution for Mitigating the Hazards of Arc Flash Incidents in the Workplace

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

NECA S System Approach to Electrical Safety for NFPA 70E

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Are Electrical Switchgear Surveys Still the Low-Hanging Fruit of Infrared Thermography?

NECA S System Approach to Electrical Safety for NFPA 70E

Monitoring of Electrical Equipment Failure Indicators and Alarming

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

NFPA 70B and the Importance of Electrical Predictive Maintenance

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

PROTECTING AGAINST ARC FLASH HAZARDS

October Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance

Compliance without compromise Safety without sacrifice

The Basics Arc Flash Protection

Safety Meeting Topic #37 NFPA 70E What is it?

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

NFPA 70E Edition Update

UNDERSTANDING 2015 CHANGES TO NFPA 70E

UNDERSTANDING 2015 CHANGES TO NFPA 70E

Energy Conservation and Equipment Reliability With Ultrasound

PGR-8800 TECHNICAL FAQ

Property risk solutions

A WORLD WITHOUT DOWNTIME

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

Surface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Compliance Solutions: NFPA 70E 2018 Edition from Schneider Electric Services

Infrared Business Tips & Insight

Electrical Safety for Facility Managers and Building Owners

NFEC FIRE SAFETY SEMINAR Krish Mysore

SEL Arc-Flash Solutions

INSPECT & MONITOR 24/7 SOLUTIONS FOR ELECTRICAL CABINETS. IR Windows & AX8 Thermal Imaging Temperature Sensor

SEL Arc-Flash Solutions

How to reduce exposure to arc flash hazards

Thermography Report. For: (Client) at: (location)

Combustible Wood Dust Management Program Development Guide

Engineering Design & Testing Corp./EDT Engineers, P.C.

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

Electrical Preventive Maintenance (EPM) Program

Guidance on Video Smoke Detection Technology (VSD)

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

The safe way to verify the absence of voltage.

SALISBURY ASSESSMENT SOLUTIONS

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

The evolution of level switches and detectors

DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control

NFPA 70E Electrical Safety in the Workplace

TABLE OF CONTENTS 1 AVO TRAINING INSTITUTE MISSION STATEMENT 2 AVO AT A GLANCE 4 TRAINING LOCATIONS 6 ELECTRICAL CONSULTING SERVICES

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3

NECA. Standard for Electrical Safety in the Workplace

COMBUSTIBLE DUST HAZARD RECOGNITION

Multi-Technology Fault Identification

Contractor Safety. Workplace Safety & Environmental Division

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

RESNET Infrared Inspection Standard and Certification

ADIPEC 2013 Technical Conference Manuscript

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

CONTINUOUS MONITORING IS ON THE RISE:

ROBOTICS OPERATORS FOR IECEX/ATEX OPERATION

Promoting Electrical Safety through NFPA 70E Standards Adherence

How many time has your company been asked by an owner or customer to work on equipment energized?

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Transcription:

Reducing Arc Flash Risks with Electrical Maintenance By Martin Robinson, CMRP Level III Thermographer President, IRISS Inc. Abstract: Electrical accidents, such as arc flashes, happen daily; however, there are ways companies and individuals can reduce the occurrence of these accidents and protect everybody concerned from the physical, financial, and statutory consequences. The National Fire Protection Association (NFPA) regulation 70E provides a reference for facilities to meet the requirements of electrical workplace safety while regulation 70B outlines the best practices for setting up and maintaining and Electrical Preventive Maintenance (EPM) program.

Value of NFPA At the heart of NFPA 70E and OSHA initiatives is the hierarchy of control. This concept attempts to mitigate arc flash risk wherever possible. In order of preference, the hierarchy of control prioritizes: 1. Risk Elimination 2. Substitution (with lower risk) 3. Engineering Controls (such as arc resistant switchgear) 4. Safe Work Practices 5. PPE NFPA 70E and OSHA state that electrical equipment should be de-energized prior to opening. Some maintenance tasks have to be completed while the switchgear is loaded and energized, rapidly causing electrical maintenance safety devices (EMSDs) to be a hot topic. Their popularity is growing as companies strive to improve profitability, uptime and safety. Those who are implementing EMSD based programs are reaping significant benefits in terms of efficiency gains, cost control and fire prevention. Because lower PPE levels are required, inspections are quicker. IRISS Offers Courses That Train on Content From NFPA 70E Standards.

Value of NFPA One of the tasks that need to be completed on electrical equipment whilst it is energized and under load is infrared (IR) scanning. IR cameras can only measure what they can see and cannot see through glass or plastic viewing windows commonly fitted in switchgear. To allow the inspections to be completed under load, we use an IR window, an EMSD, that allows an IR camera to see the energized loaded connections through a special lens materials in the IR windows. Allowing switchgear to remain closed and in a safe and guarded condition thus ensuring that the inspector is never exposed to the dangers of arc flash or electrocution. Much of the recent acceptance of IR windows has coincided with the increase in level of awareness regarding electrical safety, risk reduction and arc flash. Organizations such as the IEEE have been at the vanguard of this movement with its Safer by Design campaign. In response, switchgear manufacturers are increasingly installing IR window at the point of manufacture. With IRISS IR Windows, Inspectors are Never Exposed to The Dangers of Arc Flash. Other tasks where EMSDs are used to eliminate a potential arc flash include: Airborne Ultrasound (EMSD - Ultrasound Ports) Voltage Detection (EMSD - External Voltage detection ports) Motor Current Analysis (EMSD Voltage Tap Off Connections) Other EMSD strategies include the use of online monitoring systems that transmit data back directly to the client utilizing either wired or wireless sensor systems. These systems include: Temperature measurement (Contact and non-contact systems) Vibration Analysis (Rotating UPS and generator Systems) Power Quality (Online and fixed data collection systems) Partial Discharge (Online and fixed data collection systems)

Benefits of EMSDs The benefit of using ESMDs is that they standardize the inspection routes as they become data collection points for the test equipment. They also ensure that all the inspection parameters are fixed and that all collected data is standardized ensuring that any trend analysis data is accurate. Other benefits include: Maintain switchgear in an enclosed and guarded condition Remove risk of electrocution and possible triggers of an arc flash incident Removal of high risk behaviors Conduct valuable, fully loaded online inspections Access Inaccessible equipment Because there is no panel removal required: - inspections require less manpower - inspections require lower Personal Protection Equipment (PPE) levels - inspections are faster and more efficient - More inspections are completed due to ease of operation IRISS Windows Allow for Fully Loaded Online Inspections. Summary It is significant that most electrical maintenance and safety standards value the use of Condition Based Maintenance (CBM) inspections such as IR surveys, ultrasound inspections, vibration analysis, MCA, and partial discharge testing as a critical part of an electrical preventative maintenance program (EPM). EMSDs, such as IR windows, have now provided a way for companies to comply with the recommendations for inspection processes, while complying with the mandate for arc flash avoidance. Most if not all of these organizations agree that electrical equipment should not be opened unless it is de-energized. EMSDs provide a way for companies to comply with recommendations for inspection and safety standards/ guidelines while protecting personnel, equipment and profits.

About The Author For over 30 years, Martin Robinson has been a pioneer in the field of maintenance technology. Robinson, an innovator and pioneer of Infrared (IR) Thermography has consulted with international maintenance and reliability leaders on electrical preventive maintenance and electrical safety standards of NFPA and OSHA. A recognized authority in the field of IR Thermography, Robinson has designed CBM programs to include IR, Non-destructive Testing (NDT) and implementation of green energy initiatives and energy management strategies. He is Level III Certified IR Thermographer, Certified Maintenance and Reliability Professional (CMRP) through the Society for Maintenance and Reliability Professionals (SMRP), member of IEEE, NFPA and is a standing member on the technical committee CSA Z463 guidelines on maintenance of electrical systems and IEEE P1854 - Electrical System Design to Improve Electrical Safety.