S E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S

Similar documents
SERIES BM. Concealed Fan Convector

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

Installation, Operation & Maintenance Instructions Document Ref:

H Y D R O C O U R S E T R E N C H H E A T I N G

Panther Fan Coil Units

Ocelot Fan Coil Units

Installation, Operation and Maintenance Instructions Document Ref:

Installation, Operation and Maintenance Instructions Document Ref:

Installation, Operation & Maintenance Instructions Document Ref:

WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

Efficient Cooling and Heating. Flexibility Is The Key

Panther Fan Coil Unit

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

P R O D U C T G U I D E LST

Metropolitan high output natural and powered trench heaters

FORCEFLOW. 900 Series Fan Convectors

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Aegean Range. A new range of fan coils for heating and cooling commercial applications

spc-hvac.co.uk BELGRAVIA eco FAN CONVECTORS WITH EC MOTORS

BELGRAVIA eco FAN CONVECTORS WITH EC MOTORS

TOSHIBA AIR CONDITIONING

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Installation, operation and Maintenance Manual

Product Specifications. Vertical Floor Consoles By First Co.

Caice Attenuator Selector - Specifier Edition

EHH SERIES DRAW THROUGH FAN COILS CFM

Caice Attenuator Selector - Specifier Edition

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

LOW SURFACE TEMPERATURE RADIATORS

System architecture. Air treatment Index

Specification Data. General:

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Caice Attenuator Selector - Specifier Edition

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

The new Xcell EC High Efficiency Range Fresh air pure and simple

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Centrifugal air heaters hot water or electrical supply

Regulations covering Heating and Ventilation equipment in Schools

EC Motor Fan Coil Units. IMD-Y Series l/s

Polaris-I-60. active chilled beam. the future of space conditioning

Recessed. Air Curtain. Fig 1. Recessed air curtain

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

The Sentinel Kinetic Horizontal Range

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

AP-EH500-L/RQA9837. Installation Guide

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

technical data Fan coil unit FWB small duct unit

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Commercial Heating Domestic Heating

Lo-Carbon Sentinel Kinetic Horizontal

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

SECTION (15767) - UNIT HEATERS

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Energy-efficient heat source provides comfort in large rooms

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

SKYPAK II, 3 Ton Series, gives you a

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SECTION FAN COIL UNITS

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

VERTICAL FAN COIL UNITS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

QTS SELECTION TECHNICAL BOOKLET

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Actionair Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

Enriching Environments

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

INDUSTRIAL AIR CURTAIN. IndAC 2

LZT High efficiency air to water heat pumps with E.V.I. compressors

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Halton Rex for Vario R6O - Variable air volume chilled beam

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Providing Natural Solutions to Heating

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

ENGINEERING SPECIFICATIONS

Halton CHB Active chilled beam with boost function for bulkhead installation

ENGINEERING SPECIFICATIONS

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Technology for life. Unit heater LH

Transcription:

S E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S Concealed chassis fan convector with range of 8 standard models Each model available in 9 sizes with 4 heating coil options 1-18kW output with LPHW 50-130 C heating media EC energy efficient fan motors or conventional AC synchronous motors Extensive range of thermostatic and user control options including external BMS speed control Electric heating up to 6kW single phase Automatic and user control including BMS control

CONTENTS IDENTIFICATION Introduction 2 Quality 2 DESCRIPTION Range 2-4 Composition-Features 3 Accessories 4-10 PERFORMANCE 8 Heat outputs-lthw 11-13 Correction Factors 12-13 Electrical data 14 APPLICATION General 15 Selection 16 Dimensions 17-34 Engineering specification 35 CONSTRUCTION Handling 36 Storage 36 Preparation 36 Installation details 36 Pipework connections 36 Electrical connections 36 Installation of model 3 36 PRICES & CONDITIONS OF SALE Prices 36 Standard conditions of sale 36 IDENTIFICATION Introduction Series BM fan convector heaters are a extensive range of concealed warm air heaters, with a broad range of sizes, options and accessories to suit any project. They provide warm air heating when connected to a low or medium temperature hot water system and a single phase electrical supply. Quality Dunham-Bush operates a quality control system and is a registered firm of assessed capability BS EN ISO 9001 : 2015 Description Each Series BM fan convector comprises a galvanised sheet steel casing with access panel, fan and motor platform, air filter, hot water heating coil and electrical connections box. A single phase electric heating coil can be supplied instead of a hot water coil, with an output up to 6kW. Heaters are supplied for single or two speed operation. Single speed heaters are set to low, medium or high speed. Two speed heaters are set to low/ medium, low/high or medium/high speeds. Both fan and heat control is provided by switches and/or thermostats, listed in the Accessories section of this brochure. Range The range consists of 8 standard models, for concealed floor, wall, ceiling and base mounting. All models can be supplied in a range of figure numbers (sizes). The figure number relates to the nominal heat output at medium speed and length, as shown below. TECHNICAL SUPPORT SERVICES Product support 36 SUPPLY Availability 36 Packaging 36 Ordering 36 Delivery to site 36 Coil capacities 38 Heater masses 38 Order codes 39 Size Nominal output (kw) Nominal length (mm) Fig 03 2.9 800 Fig 04 4.9 1000 Fig 06 5.9 1000 Fig 08 8.4 1300 Fig 10 8.9 1300 Fig 12 10.2 1600 Fig 15 10.9 1600 Fig 16 13.6 1300 Fig 18 16.5 1600 Nominal outputs are based on LPHW 80/70 C, entering air 18 C, 25Pa external resistance at medium speed and coil 2

COMPOSITION - FEATURES Air vent (optional manual, automatic or plugged) Coil connections (DN20) Heating coil Access panel Fan and motor platform Washable air filter Filter access panel Electrical connections box Series BM Model 3 figure 04 LH connections Air vent (optional manual, automatic or plugged) Serial number label Heating coil Coil connections Air thermostats (optional) Access panel Filter access panel Fan and motor platform Washable air filter Control box Mains supply plug Series BM Model 1 figure 04 LH connections 3

RANGE OF STANDARD MODELS Series BM is a available in 8 models for concealed installation above ceilings or soffits, below raised floors or behind wall enclosures or panels. Each model is available with a range of accessories to duct return air to the inlet and distribute supply air to the heated space. ACCESSORIES Each model can be supplied with a range of fitted or remote accessories, detailed in the following pages. Air thermostats Air thermostats can be provided to automatically switch the heater on/off and to change the fan speed/heat output, in response to a fall or rise in ambient air temperature. Fitted air thermostats Models 1 and 2 only. Capillary thermostats can be fitted for on/off and speed change. Remote thermostats Standard or tamper resistant, wall mounting room thermostats, with accelerator heater can be provided, for on/off and speed change. Low temperature cut-out thermostat (LTC) A low temperature cut-out thermostat can be provided to prevent the heater operating until the heating water temperature is hot enough for it to work efficiently. This thermostat will automatically stop the heater at the end of the normal operating period, when the boiler plant closes down. Fitted on/off and speed change capillary thermostats Type 1, fixed setting LTC, break circuit 38 C±3K, make circuit 50 C±3K If fitted, type 1 is wired into the control circuit and clamped to the coil tube nearest to the LTHW flow connection. Note, maximum operating temperature of 95 C. Type 3, adjustable setting LTC, range 30 C to 90 C If supplied, type 3 is wired into the control circuit and stored inside of the heater casing, for clamping to the LTHW flow pipe by the installer. Note, maximum operating temperature of 95 C. Quick release filter access panel 4

Switches Remote switches can be provided to switch the heater on/off, change fan speed, allow thermostats to work automatically or to override any thermostats. The override manual switch allows the fans to circulate room air when the boiler plant is shut down during the summer. A remote switch can also be provided to open or close motorised dampers, if a motorised damper box is supplied. Switches can also be fitted to the electrical connections box. Remote switches flush or surface mounting Switch Operation 1 On/off 2 High/off/low 3 Maual/off/auto 4 Manual/off/auto & high/low 5 F.A.I/Recirc 6 F.A.I/Recirc & high/off/low 7 F.A.I/Recirc manual/off/auto 8 F.A.I/Recirc manual/off/auto & high/low Fitted switches on control box F.A.I = fresh air inlet, Recirc. = recirculation air inlet Switches fitted to heater electrical connections box. Switch Operation 1 On/off 2 High/off/low 3 Manual/off/auto 4 Manual/off/auto & high/low Electric heating All models, figure numbers 3, 4 and 6 only, can be fitted with a single phase, single stage electric heating module, instead of the standard hot water heating coil. The module includes electric element(s), power relay, high temperature cut-out and miniature circuit breakers. Please refer to the Performance section of this catalogue for outputs of models with electric heater modules. Note: Control options for electric heating are limited by EU legislation; refer to pages 38 and 39. Fitted isolating ball valves Special controls Various special control arrangements can be supplied to suit particular applications. 24VAC relays can be fitted, to allow master/slave operation of several fan convectors from one pair of room thermostats, or from a remote control system. Please contact a Dunham-Bush Sales representative for details. Fan motors As well as conventional synchronous AC motors, energy efficient EC motors are also available. EC motors can be provided with a fitted electronic speed controller (option EC2) enabling connection to air thermostats and switches. Alternatively, EC motors can be fitted where speed control is provided by an external 2-10VDC signal (option EC1). EC/DC fan motors 5

Inlet box 01 Provides air inlet on access side on models 1, 3 and 7. Provides air inlet opposite to access side on model 4. Inlet box 02 Provides air inlet opposite to access side on models 1, 3 and 7. Provides air inlet on access side on model 4. Outlet box 01 Provides air outlet on access side on models 1, 3, 5, 7 and 8. Provides air outlet opposite to access side on models 4 and 6. Inlet box 01 and 02. Outlet box 01 and 02 Outlet box 02 Provides air outlet opposite to access side on models 1, 2, 3, 5, 7 and 8. Provides air outlet on access side on models 4 and 6. 180 Manual damper box 03 Provides air inlet on access side and opposite to side on models 1, 3, 4 and 7. Manual adjustment of fresh air/ recirculation air mixture. 180 Motorised damper box 04 Provides air inlet on access side and opposite side on models 1, 3, 4 and 7. Motor supply 24VAC/1ph/50Hz, non -modulating. A remote switch or thermostat is necessary to change the damper from full fresh air to full recirculation. 180 manual damper box 03 90 Manual damper box 05 Provides air inlet on the access side and bottom on model 1. Provides air inlet on the access side and end on model 3. Provides air inlet opposite to access side and end on model 4. Provides air inlet on access side and top on model 7. Manual adjustment of fresh air/recirculation air mixture. 90 Manual damper box 06 Provides air inlet opposite to access side and bottom on model 1. Provides air inlet opposite to access side and end on model 3. Provides air inlet on access side and end on model 4. Provides air inlet opposite to access side and top on model 7. Manual adjustment of fresh air/recirculation air mixture. 180 motorised damper box 04 6

90 Motorised damper box 07 Provides air inlet on access side and bottom on model 1. Provides air inlet on access side and end on model 3. Provides air inlet opposite to access side and end on model 4. Provides air inlet on access side and top on model 7. Motor supply 24VAC/1ph/50Hz, non-modulating. A remote switch or thermostat is necessary to change the damper from full recirculation to full fresh air. 90 Motorised damper box 08 Provides air inlet opposite to access side and bottom on model 1. Provides air inlet opposite to access side and end on model 3. Provides air inlet on access side and end on model 4. Provides air inlet opposite to access side and top of model 7. Motor supply 24VAC/1ph/50Hz, non-modulating. A remote switch or thermostat is necessary to change the damper from full recirculation to full fresh air. Note; Spring return and modulating damper motors are available upon request, Consult your Sales representative. Circular spigot box SB Provides spigots for circular duct connections on inlet on models 1, 3, 4 and 7. Provides spigots for circular duct connections on outlet on all models 1 to 8 inclusive. Please refer to Accessories Dimensions for sizes and positions of spigots. 90 motorised damper box 07 and 08 Circular spigot box SB Circular spigot plate SP Provides spigots for circular duct connections on inlet of models 1, 3, 4 and 7 Provides spigots for circular duct connections on outlet on all models 1 to 8 inclusive. Please refer to Accessories Dimensions for sizes and positions of spigots. Rectangular spigot plate RS Provides spigot for rectangular duct connection on outlet of all models. Loose grille LG can be connected directly to spigot plate RS. Maximum wall panel thickness 34mm. Circular spigot plate SP Rectangular spigot plate RS 7

Fitted plinth, P1 and P2 A 100mm plinth P1, or 150mm plinth P2, can be fitted on vertical models to raise the heater and provide additional clearance between the bottom of the heater and the finished floor level. A plinth can be fitted directly to model 2 and with other suitable accessories on models 1, 7 and 8. Fitted isolating valves, B and G Isolating ball valves B or gate valves G, can be fitted to flow and return coil connections. Plinth P1 and P2 Pencil proof loose grille with fixing frame LG and FF Pencil proof loose grilles (LG) with fixing frames (FF) can be provided for use with all models. The fixing frame is intended for installation in a wall opening, allowing the loose grille to be fixed to the frame with screws, which are recessed between the grille blades. A loose grille has a natural satin anodised surround and black powder coated grille core. Loose grilles are unsuitable for external use. Proprietary weatherproof louvres are recommended where outside air is to be introduced. Loose grille LG and fixing frame FF Extension duct E1, E2 & E3 Provides adjustable height extension of 200 to 400mm (E1), 400 to 800mm (E2) or 800 to 1600mm (E3), when fitted to vertical models 1, 2, 7 and 8, with other accessories. Extension duct E1, E2 and E3 8

MODEL BM1 ACCESSORIES MODEL BM2 ACCESSORIES MODEL BM7 ACCESSORIES MODEL BM8 ACCESSORIES 9

MODELS BM3 & BM4 ACCESSORIES MODEL BM5 & BM6 ACCESSORIES 10

PERFORMANCE Heat outputs WA2 coil for standard LPHW applications Heat outputs (kw), air volume flow rates (l/s), leaving air temperatures ( C) and hydraulic resistances (kpa). Conditions: LTHW 80/70 C and entering air temperature 18 C. Size Coil type Low speed Medium speed High speed kw l/s C kpa kg/s kw l/s C kpa kg/s kw l/s C kpa kg/s Fig 03 WA2 1.9 55 46 0.34 0.05 2.9 85 47 0.80 0.07 3.4 100 46 1.03 0.08 Fig 04 WA2 3.5 85 52 1.26 0.09 4.9 120 52 2.38 0.12 5.6 140 51 3.07 0.14 Fig 06 WA2 4.9 120 52 2.38 0.12 5.9 150 51 3.37 0.14 6.6 175 49 4.13 0.16 Fig 08 WA2 7.0 175 51 2.36 0.17 8.4 215 50 1.21 0.20 8.9 235 49 1.36 0.22 Fig 10 WA2 7.6 190 51 2.75 0.19 8.9 235 49 1.36 0.22 9.6 260 48 1.56 0.23 Fig 12 WA2 6.6 160 52 2.19 0.16 10.2 250 52 2.00 0.25 11.7 300 50 2.58 0.29 Fig 15 WA2 9.2 225 52 1.65 0.23 10.9 270 51 2.24 0.27 12.3 320 50 2.81 0.30 Fig 16 WA2 10.5 270 50 1.53 0.26 13.6 380 48 2.47 0.33 15.1 440 46 3.02 0.37 Fig 18 WA2 14.8 360 50 3.23 0.36 16.5 440 49 3.94 0.40 18.0 490 48 4.64 0.44 Models BM3, BM4, BM5 and BM6 - Air volume flow rates at medium speed for 25Pa external static pressure drop Models BM1, BM2, BM7 and BM8 - Air volume flow rates at medium speed for 0Pa external static pressure drop Heat outputs WA1 coil for LST or MTHW applications Heat outputs (kw), air volume flow rates (l/s), leaving air temperatures ( C) and hydraulic resistances (kpa). Conditions: LTHW 80/70 C and entering air temperature 18 C. Size Coil type Low speed Medium speed High speed kw l/s C kpa kg/s kw l/s C kpa kg/s kw l/s C kpa kg/s Fig 03 WA1 1.5 55 41 0.24 0.04 2.4 85 41 0.55 0.06 2.8 100 41 0.71 0.07 Fig 04 WA1 2.5 85 42 0.67 0.06 3.6 120 43 1.38 0.09 4.1 140 42 1.66 0.10 Fig 06 WA1 3.6 120 43 1.30 0.09 4.2 150 41 1.79 0.10 4.1 175 40 2.15 0.11 Fig 08 WA1 5.0 175 42 1.22 0.12 6.0 215 41 1.72 0.15 6.3 235 40 1.93 0.15 Fig 10 WA1 5.4 190 42 1.45 0.13 6.3 235 40 1.93 0.15 6.7 260 39 2.17 0.16 Fig 12 WA1 4.7 160 42 1.14 0.11 7.4 250 42 2.71 0.18 8.3 300 41 1.36 0.20 Fig 15 WA1 6.6 225 42 2.23 0.16 7.8 270 42 1.21 0.19 8.7 320 40 1.47 0.21 Fig 16 WA1 7.5 270 41 2.62 0.18 9.5 380 39 1.26 0.23 10.5 440 38 1.54 0.26 Fig 18 WA1 10.2 360 41 1.60 0.25 11.6 440 40 2.02 0.28 12.5 490 39 2.36 0.31 Models BM3, BM4, BM5 and BM6 - Air volume flow rates at medium speed for 25Pa external static pressure drop Models BM1, BM2, BM7 and BM8 - Air volume flow rates at medium speed for 0Pa external static pressure drop Heat outputs WA3 coils for low grade LPHW applications Heat outputs (kw), air volume flow rates (l/s), leaving air temperatures ( C) and hydraulic resistances (kpa). Conditions: LTHW 80/70 C and entering air temperature 18 C. Size Coil type Low speed Medium speed kw l/s C kpa kg/s kw l/s C kpa kg/s kw l/s C kpa kg/s Fig 03 WA3 2.9 55 61 0.77 0.07 4.4 85 61 1.72 0.01 5.1 100 60 2.24 0.12 Fig 04 WA3 4.6 85 63 20.80 0.11 6.4 120 62 3.92 0.16 7.4 140 62 5.10 0.18 Fig 06 WA3 6.4 120 62 3.92 0.16 7.8 150 61 3.82 0.19 8.8 175 60 4.78 0.22 Fig 08 WA3 9.2 175 61 1.45 0.22 11.0 215 60 2.03 0.27 11.8 235 60 2.32 0.29 Fig 10 WA3 10.0 190 61 1.68 0.24 12.4 235 59 2.54 0.30 14.4 260 58 3.36 0.35 Fig 12 WA3 8.6 160 63 1.45 0.21 13.3 250 62 3.30 0.33 15.5 300 61 4.35 0.38 Fig 15 WA3 12.0 225 62 2.71 0.29 14.3 270 62 3.73 0.35 16.3 320 60 4.79 0.40 Fig 16 WA3 13.9 270 61 2.58 0.34 18.2 380 58 4.34 0.45 20.4 440 56 3.49 0.50 Fig 18 WA3 18.8 360 61 3.46 0.46 22.0 440 59 4.64 0.54 24.1 490 59 5.52 0.59 Models BM3, BM4, BM5 and BM6 - Air volume flow rates at medium speed for 25Pa external static pressure drop Models BM1, BM2, BM7 and BM8 - Air volume flow rates at medium speed for 0Pa external static pressure drop High speed 11

Correction factors for WA1, WA2 & WA3 heating coils Approximate factors for heat output (kw) and hydraulic resistance (kpa) Mean water ( C) Entering air temperature ( C) Water temperature drop across coil 5k 10k 15k 20k Output Hyd. Res. Output Hyd. Res. Output Hyd. Red. Output Hyd. Res. 0 0.69 1.92 0.59 0.35 - - - - 40 18 0.34 0.47 0.24 0.06 - - - - 20 0.30 0.36 0.21 0.03 - - - - 0 0.78 2.46 0.71 0.50 - - - - 45 18 0.44 0.79 0.33 0.11 - - - - 20 0.50 0.65 0.30 0.09 - - - - 0 0.88 3.08 0.82 0.68 - - - - 50 18 0.54 1.17 0.44 0.20 - - - - 20 0.50 1.02 0.40 0.16 - - - - 0 0.98 3.84 0.93 0.87 - - - - 55 18 0.65 1.66 0.58 0.33 - - - - 20 0.61 1.48 0.54 0.29 - - - - 0 1.08 4.68 1.04 1.09 - - - - 60 18 0.75 2.23 0.70 0.49 - - - - 20 0.71 2.05 0.66 0.44 - - - - 0 1.18 5.53 1.14 1.30 1.10 0.54 - - 65 18 0.84 2.83 0.80 0.65 0.74 0.24 - - 20 0.80 2.59 0.77 0.59 0.70 0.22 - - 0 1.27 6.44 1.24 1.54 1.20 0.64 1.16 0.37 70 18 0.94 3.51 0.90 0.81 0.85 0.32 0.81 0.14 20 0.90 3.23 0.86 0.75 0.81 0.29 0.76 0.12 0 1.37 7.47 1.34 1.78 1.31 0.76 1.26 0.40 75 18 1.03 4.25 1.00 1.00 0.96 0.41 0.90 0.20 20 0.99 3.95 0.96 0.93 0.93 0.38 0.86 0.18 0 1.46 8.55 1.43 2.05 1.40 0.57 1.37 0.47 80 18 1.13 5.07 1.10 1.20 1.06 0.5 1.02 0.26 20 1.09 4.47 1.06 1.12 1.03 0.47 0.98 0.24 0 - - 1.53 2.33 1.50 1.00 1.47 0.54 85 18 - - 1.19 1.42 1.16 0.60 1.13 0.32 20 - - 1.16 1.34 1.13 0.56 1.09 0.30 0 - - 1.62 2.64 1.60 1.14 1.57 0.62 90 18 - - 1.29 1.66 1.26 0.71 1.23 0.38 20 - - 1.25 1.57 1.22 0.67 1.20 0.36 12

Heat outputs ultra low grade LPHW WA4 Avant-Garde heating coil Heat outputs (kw), air volume flow rates (l/s), leaving air temperatures ( C) and hydraulic resistances (kpa). Conditions: LTHW 55/35 C and entering air temperature 18 C Size Coil type Low speed Medium speed High speed kw l/s C kpa kw l/s C kpa kw l/s C kpa Fig 03 WA4 1.6 50 44 0.6 2.4 75 44 1.3 3.3 105 44 2.4 Fig 04 WA4 2.5 75 46 1.9 4.0 115 46 4.2 5.4 160 46 7.4 Fig 06 WA4 3.6 105 46 3.5 5.1 150 46 6.7 6.0 180 46 8.9 Fig 08 WA4 4.2 135 44 0.9 6.7 210 44 2.0 8.5 270 44 3.1 Fig 10 WA4 6.1 190 44 1.7 7.9 250 44 2.8 9.1 290 44 3.6 Fig 12 WA4 6.9 205 46 3.1 9.9 290 46 5.9 11.9 360 45 8.2 Fig 15 WA4 9.3 270 47 5.3 11.2 335 46 7.4 12.0 360 45 8.2 Models BM3, BM4, BM5 and BM6 - Air volume flow rates at medium speed for 25Pa external static pressure drop Models BM1, BM2, BM7 and BM8 - Air volume flow rates at medium speed for 0Pa external static pressure drop Hydraulic resistance includes 4 port control valve Correction factors for WA4 coils only Approximate factors for heat output (kw) and hydraulic resistance (kpa) Mean water C Entering air temperature C Water temperature drop across coil 10k 15k 20k Output Hyd. Res. Output Hyd. Res. Output Hyd. Res. 0 1.68 6.6 1.68 3.3 1.68 2.1 45 18 1.00 2.7 1.03 1.5 1.00 1.0 20 0.93 2.4 0.95 1.4 0.92 0.9 0 1.86 7.7 1.86 3.9 1.86 2.4 50 18 1.18 3.5 1.21 1.9 1.20 1.3 20 1.11 3.2 1.14 1.8 1.12 1.1 0 2.12 9.5 2.09 4.7 2.05 2.8 55 18 1.37 4.5 1.40 2.4 1.40 1.5 20 1.28 4.1 1.33 2.2 1.33 1.4 0 2.34 11.1 2.29 5.4 2.25 3.2 60 18 1.58 5.7 1.59 2.9 1.60 1.8 20 1.51 5.3 1.52 2.7 1.52 1.7 0 2.52 12.6 2.51 6.1 2.43 3.6 65 18 1.78 6.9 1.78 3.1 1.78 2.2 20 1.71 6.4 1.71 3.2 1.71 2.0 Heat outputs electric heating Heat outputs (kw), air volume flow rates (l/s) and leaving air temperatures ( C) Conditions : 230VAC/1ph/50Hz electrical supply, entering air 18 C. Size Coil type Output No. of Low speed Medium speed High speed Current (kw) Stages l/s C l/s C l/s C (A) Fig 03 E11 1.5 1 X 1.5 Electric heating not 85 33 100 31 6.5 Fig 03 E21 3.0 1 X 3.0 recommended on 85 47 100 43 13.0 Fig 04 E21 2.0 1 X 2.0 low speed due to 120 32 140 30 8.7 Fig 04 E31 3.0 1 X 3.0 high leaving air 120 39 140 36 13.0 Fig 04 E41 4.0 1 X 4.0 temperatures 120 46 140 42 17.4 Fig 06 E51 5.0 1 X 1.50 150 46 175 42 21.7 Fig06 E61 6.0 1 X 6.0 150 51 175 47 26.1 Models BM3, BM4, BM5 and BM6 - Air volume flow rates at medium speed for 25Pa external static pressure drop Models BM1, BM2, BM7 and BM8 - Air volume flow rates at medium speed for 0Pa external static pressure drop 13

Electrical Data for AC motors Models BM3, BM4, BM5 and BM6 - Air volume flow rates at medium speed for 25Pa external static pressure drop Models BM1, BM2, BM7 and BM8 - Air volume flow rates at medium speed for 0Pa external static pressure drop Fig No. Fan voltage (VAC) Low speed Medium speed High speed Airflow (l/s) Running current (A) SFP (W/l/s) Fan voltage (VAC) Airflow (l/s) Running current (A) SFP (W/l/s) Fan voltage (VAC) Airflow (l/s) Running current (A) SFP (W/l/s) 3 110 55 0.27 0.47 150 85 0.27 0.52 180 100 0.30 0.60 4 120 85 0.28 0.47 160 120 0.37 0.53 180 140 0.41 0.57 6 150 120 0.35 0.48 180 150 0.41 0.53 210 175 0.43 0.54 8 140 175 0.52 0.46 180 215 0.56 0.48 210 235 0.57 0.52 10 150 190 0.54 0.45 190 235 0.57 0.47 240 260 0.58 0.54 12 120 160 0.43 0.35 170 250 0.60 0.42 210 300 0.65 0.45 15 150 225 0.55 0.39 180 270 0.62 0.41 220 320 0.66 0.45 16 130 270 1.07 0.54 150 380 1.14 0.55 180 440 1.00 0.53 18 150 360 1.20 0.57 180 440 1.17 0.53 210 490 1.12 0.52 Electrical Data for EC motors, Models BM1, BM2, BM7 & BM8 Low speed Medium speed High speed Fig No. Control signal (VDC) Airflow (l/s) Running current (A) SFP (W/l/s) Control signal (VDC) Airflow (l/s) Running current (A) SFP (W/l/s) Control signal (VDC) Airflow (l/s) Running current (A) SFP (W/l/s) 3 3.3 55 - - 4.6 85 - - 5.3 100 - - 4 3.3 85 - - 4.4 120 - - 4.9 140 - - 6 4.4 120 - - 5.2 150 - - 6.0 175 - - 8 4.1 175 - - 4.8 215 - - 5.2 235 - - 10 4.4 190 - - 5.2 235 - - 5.9 260 - - 12 3.7 160 - - 5.2 250 - - 6.0 300 - - 15 4.7 225 - - 5.4 270 - - 6.3 320 - - 16 4.4 270 - - 5.9 380 - - 6.7 440 - - 18 5.4 360 - - 6.5 440 - - 8.8 490 - - For running currents and specific fan powers, refer to Dunham-Bush with application details. Electrical Data for EC motors, Models BM3, BM4, BM5 & BM6 Fig No. Control signal (VDC) Airflow (l/s) Low speed Medium speed High speed Running current (A) SFP (W/l/s) Control signal (VDC) Airflow (l/s) Running current (A) SFP (W/l/s) Control signal (VDC) Airflow (l/s) Running current (A) SFP (W/l/s) 3 3.9 55 - - 6.0 85 - - 7.3 100 - - 4 4.6 85 - - 6.1 120 - - 7.1 140 - - 6 5.4 120 - - 6.8 150 - - 7.8 175 - - 8 5.3 175 - - 6.2 215 - - 6.7 235 - - 10 5.4 190 - - 6.5 235 - - 7.1 260 - - 12 4.5 160 - - 6.5 250 - - 7.6 300 - - 15 5.8 225 - - 6.7 270 - - 7.8 320 - - 16 5.1 270 - - 6.8 380 - - 8.8 440 - - 18 5.9 360 - - 7.4 440 - - 8.8 490 - - For running currents and specific fan powers, refer to Dunham-Bush with application details. 14

APPLICATION General Dunham-Bush Series BM is available in a versatile range of 8 models, each produced in nine sizes and three hot water coils, with alternative electric heating up to 6kW. It is the ideal heating product for many applications, such as schools, colleges, elderly persons homes, libraries, offices and churches. It is suitable for floor, wall, ceiling and base mounting, concealed within the building fabric or ceiling void. Where cased models are required within the room being heated or in an adjacent room to that being heated, Dunham Bush Series AM fan convectors are recommended. Models 1, 3, 4 and 7 are available with optional manual or motorised dampers and can used for heating, ventilation or free cooling, since they allow the introduction of tempered primary or fresh air into the room. If fresh air is to be Introduced during the winter season, the hot water coil must have frost protection and external weatherproof louvres must be fitted. Care should be taken to ensure heaters are sited so that airflow will not be obstructed. This is particularly important when using reversed air flow models 7 and 8, and any model with electric heating. Ceiling mounting models 3, 4, 5 and 6 are generally less effective than floor mounted models, since the entering air temperature is higher at ceiling level and the warm buoyant discharge air may cause stratification and take longer to produce comfortable conditions at occupancy level. For these reasons, we recommend floor or wall mounting models where the application allows. LST Application With many years of experience in the UK heating industry, Dunham-Bush has recognised the need for a low surface temperature (LST) heating capable of delivering duties far in excess of those associated with natural LST convectors. Series BM LST heaters provide the end user with a fan convector that delivers all the functionality and reliability of the much acclaimed products in the existing Dunham- Bush ranges. This, coupled with the assurance that NHS guidelines for safe touch temperatures are being met, ensures that fast and efficient heating can be delivered into safety critical areas. When the air in the room is at the required temperature and the fans are either automatically or manually switched off, the fitted 4 port valve diverts hot water away from the coil eliminating the problem of unwanted natural convection increasing the discharge grille temperature. A 4 port valve is supplied as standard, however a 2 port valve is an available option, thus enabling variable flow pumps to be used to optimise energy efficiency. Note that low temperature cut out (LTC) thermostats cannot be fitted on 2 port valve applications. Avant-Garde Application The Dunham-Bush Avant-Garde unit is designed to operate at 55 C flow and 35 C return, whilst maintaining the same duty, options and features as the extensive range of Series BM fan convector heaters. Benefits Boiler return temperature is always below 55 C ensuring the boiler is in condensing mode at all times. Increased differential water temperatures across the coil, reduces pumping energy by up to 87%. Decreased flow and return temperatures reduce standing losses from pipework. Low water content and thermal mass of unit allows rapid response preventing a protracted warm-up period and temperature overshoot. Integral 4-port valve prevents wasteful natural convection during mild conditions (2-port valve option available upon request). 15

SELECTION Refer to the Range of Standard Models on page 4 to select the model most suitable for the application. From the calculated heat loss and the operating conditions, the quantity of heaters, heat output, figure number and coil type can be selected, using tables 1, 2 and 3. If the operating conditions are different to those stated, use the appropriate factor from table 4. The air volume flow rates and heat outputs listed in the performance tables are for basic units without accessories. If circular spigot box SB or circular spigot plate SP is used, the available fan static pressure to overcome any external resistance will be reduced. Please contact a Dunham-Bush Sales representative for further assistance. If a larger room is to be heated, it is usually better to select two smaller heaters rather than one large, to give better heat distribution and lower spot noise levels. Wherever possible, heaters should be located near windows or in areas of high heat loss. It is recommended that heaters are selected to operate at medium speed for general use or at low speed for rooms where noise levels are critical. Heaters should only be selected at high speed, for non critical application, such as entrance foyers, corridors etc. or for initial rapid warm up. Sound power levels are available on request. By design, Dunham-Bush fan convectors have moderate leaving air temperatures to reduce stratification as well as low outlet velocities and low air throws to improve comfort. Comfortable conditions are achieved by good air circulation, it is recommended that if practicable, the total volume of room air should be circulated through all heaters in the room four or five times per hour. Sound data Series BM fan convectors are commercially quiet. Sound power levels, available on request, may be used to calculate NR or RC levels in accordance with the CIBSE guide or other recognised methods. Non-Catalogue Selections For selections not described in this catalogue, please contact a Dunham-Bush Sales representative. Fan/motor platform mounted on slide-out channels Avant -Garde with WA4 coil and 4 port control valve Example selection To calculate the approximate heat output, hydraulic resistance and leaving air temperature of Series BM figure 06 fitted with WA2 coil, operating at medium speed with LTHW 55 C mean and 5K drop, entering air temperature 18 C. a. From table 1, heat output 5.9kW, air volume flow rate 150 l/s, hydraulic resistance 3.37 kpa b. From table 4, heat output factor 0.65, hydraulic resistance factor 1.66. Thus: Heat output 5.9kW x 0.65 = 3.83kW Hydraulic resistance 3.37kPa x 1.66 = 5.59kPa c. To estimate the leaving air temperature with the new output, find the temperature rise Δt, and add it to the entering air temperature Δt = 3.83kW 150l/s x 0.00122kJ/lK = 21K (where 0.00122 is approximate specific heat capacity of entering air) d. Thus: leaving air temperature = 18 C + 21K = 39 C 16

DIMENSIONS OF MODEL BM1 - WITH WA1, WA2 & WA3 COILS DIMENSIONS OF MODEL BM2 - WITH WA1, WA2 & WA3 COILS 17

DIMENSIONS OF MODEL BM3 - WITH WA1, WA2 & WA3 COILS DIMENSIONS OF MODEL BM4 - WITH WA1, WA2 & WA3 COILS 18

DIMENSIONS OF MODEL BM5 - WITH WA1, WA2 & WA3 COILS DIMENSIONS OF MODEL BM6 - WITH WA1, WA2 & WA3 COILS 19

DIMENSIONS OF MODEL BM7 - WITH WA1, WA2 & WA3 COILS DIMENSIONS OF MODEL BM8 - WITH WA1, WA2 & WA3 COILS 20

DIMENSIONS OF MODEL BM1 - WITH AVANT-GARDE WA4 COIL & CONTROL VALVE DIMENSIONS OF MODEL BM2- WITH AVANT-GARDE WA4 COIL & CONTROL VALVE 21

DIMENSIONS OF MODEL BM3 - WITH AVANT-GARDE WA4 COIL & CONTROL VALVE DIMENSIONS OF MODEL BM4 - WITH AVANT-GARDE WA4 COIL & CONTROL VALVE 22

DIMENSIONS OF MODEL BM5 - WITH AVANT-GARDE WA4 COIL & CONTROL VALVE DIMENSIONS OF MODEL BM6 - WITH AVANT-GARDE WA4 COIL & CONTROL VALVE 23

DIMENSIONS OF MODEL BM7 - WITH AVANT-GARDE WA4 COIL & CONTROL VALVE DIMENSIONS OF MODEL BM8 - WITH AVANT-GARDE WA4 COIL & CONTROL VALVE 24

DIMENSIONS OF 01 & 02 INLET/OUTLET BOXES DIMENSIONS OF 03 MANUAL DAMPER BOX DIMENSIONS OF 04 MANUAL DAMPER BOX 25

DIMENSIONS OF 05 & 06 MANUAL DAMPER BOXES DIMENSIONS OF 07 & 08 MOTORISED DAMPER BOXES DIMENSIONS OF SP SPIGOT PLATE - FOR FIG 03 HEATERS 26

DIMENSIONS OF SP SPIGOT PLATE - FOR FIG 04, 06 & 16 HEATERS DIMENSIONS OF SP SPIGOT PLATE - FOR FIG 08, 10 & 18 HEATERS DIMENSIONS OF SP SPIGOT PLATE - FOR FIG 12 & 15 HEATERS 27

DIMENSIONS OF SB SPIGOT BOX - FOR FIG 03 HEATERS DIMENSIONS OF SB SPIGOT BOX - FOR FIG 04, 06 & 16 HEATERS DIMENSIONS OF SB SPIGOT BOX - FOR FIG 08, 10 & 18 HEATERS 28

DIMENSIONS OF SB SPIGOT BOX - FOR FIG 12 & 15 HEATERS DIMENSIONS OF RS RECTANGULAR SPIGOT PLATE DIMENSIONS OF P1 & P2 PLINTHS 29

DIMENSIONS OF LG & FF LOOSE GRILLE & FIXING FRAME DIMENSIONS OF E1, E2 & E3 EXTENSION DUCTS 30

SPIGOT POSITIONS AND SIZES - FOR FIG 03 HEATERS 31

SPIGOT POSITIONS AND SIZES - FOR FIG 04, 06 & 16 HEATERS 32

SPIGOT POSITIONS AND SIZES - FOR FIG 08, 10 & 18 HEATERS 33

SPIGOT POSITIONS AND SIZES - FOR FIG 12 & 15 HEATERS 34

ENGINEERING SPECIFICATIONS Series BM fan convector heaters shall be manufactured by Dunham-Bush Limited, Downley Road, Havant, Hampshire, PO9 2JD. The models, figure numbers and quantities shall be as indicated in the selection schedule and/or on the drawings. The construction of all heaters must comply with the following specification. General Each heater shall consist of a basic sheet metal casing with access panel, heating coil, fan and motor platform, air filter and electrical connections box. Basic casing Basic casings shall be assembled from 0.9mm galvanised steel panels, adequately stiffened to minimise distortion. Each casing shall have an access panel. Models 1, 3, 4 and 7 shall have a separate filter access panel. Basic casing dimensions shall be as shown in the manufactures product catalogue and shall have a manufacturing tolerance of ±1mm. Basic casing components shall be self finished galvanised steel. Hot water heating coil Heating coils shall be constructed from two rows of 9.53mm. O.D. solid drawn copper tubes, expanded into single plate corrugated aluminium fins and brazed to copper headers. Coil connections shall be specified left or right hand, determined facing the access panel and/or air outlet. Coils less air vents shall be tested to 24 bar gauge. Coils shall be provided with type M manual air vent, type A automatic air vent or type P plugged air vent, as specified Site test and working pressures, bar gauge Air vent type Maximum cold test Maximum working M 10.5 7.0 A 9.0 7.0 P 24.0 18.0 Air filter Air filters shall be washable, composed of thermally bonded polyester fibres. Filters shall be BS EN 779, class G2 (equivalent to Eurovent EU2). AC motors Motors shall be quiet running, resiliently mounted, capacitor start and run, totally enclosed, having class B insulation and rated in accordance with BS5000 part 11. EC (Electronically Commutated) motors Motors shall be quiet running 3-phase dc type with resilient mounts to minimise noise and vibration. Winding insulation shall be rated to Class B and bearings shall be sealed for life. Centrifugal fans Each fan shall be double inlet, forward curved, statically and dynamically balanced, secured to the fan motor shaft by a grub screw. Figure number 03 shall be fitted with one impeller, all other figure numbers shall be fitted with two impellers. Fan/motor platform Fan/motor platforms shall be manufactured from 1.6mm galvanised steel and shall be fitted with galvanised steel fan housing(s), a resiliently mounted motor and centrifugal impellers. Motor wiring shall be complete with a four-way line connector. The platform shall be suspended within the heater casing on resilient channels and shall be removable by sliding out. Electrical connections box and wiring Each heater shall be provided with an electrical connections box fitted to the casing on opposite side to the hot water coil connections. The electrical connections box shall contain an auto-transformer and terminal block. The box on horizontal models 3, 4, 5 and 6 shall have a hinged cover. All other models shall have a lift-off cover. Each electrical connections box shall have a fused I.E.C. mains inlet connector with a spare fuse and an I.E.C. mains inlet plug. Internal wiring shall be tri-rated, high temperature PVC insulated cable 16/0.020. Figure numbers 03 to 15 shall be fitted with 2A inlet fuses. Figure numbers 16 and 18 shall be fitted with 5A inlet fuses. Fan motor speed control An auto-transformer shall be fitted within the electrical connections box to provide energy efficient fan motor speed control. Transformers shall be wired to provide one or two speeds from the range low, medium and high. An isolated 24V AC (30VA) supply shall also be available for ELV controls. Performance Series BM fan convectors performance shall be tested and rated in accordance with BS4856, Part 1. Identification Each heater shall be complete with a nameplate indicating the model, figure number and serial number. Packaging Each heater shall be properly packed to suit the quantity being transported, and for storage in dry, indoor conditions. Heaters shall be marked with the model and figure number, and any other reference specified for site identification Accessories If specified, accessories listed in the manufacturers Product Catalogue shall be provided. 35

CONSTRUCTION Handling The purchaser is responsible for off-loading. Heaters are individually packed and two persons can usually handle the heaviest heater. When a significant quantity of heaters is delivered, they may be palletised and shrink wrapped, so a fork lift truck or similar form of lifting equipment is required. Care should be taken to ensure the heaters are not dropped or knocked under any circumstances. Storage Heaters should be stored under clean, dry indoor conditions. Packaging should not be removed until heaters are required for installation, unless damage in transit is suspected. Note the purchaser must examine the heaters promptly upon receipt and any claims for damage will only be accepted if, at the time of delivery, the consignment note is endorsed with a note detailing the damage and counter-signed by the transport company. Each heater is marked to show the model, size, serial number and any reference given on the order for site identification (stencil references). Preparation Extensive modification to the building fabric should not normally be necessary. However proper provision for fixings must be arranged. The structure to which heaters are to be fixed must be fit for purpose and capable of accepting plugs, anchors, screws or drop rods. Floor mounted models require a level base. Floor and wall models also require a flat wall surface to stand against. Installation details The access panel, fan and motor platform and filter can all be removed to allow easier handling. Pipework connections WA1, WA2 and WA3 coils - DN20 (3/4 BSP) female parallel on sizes Fig 3 to Fig 15 - DN25 (1 BSP) female parallel on sizes Fig 16 and 18 WA4 coils - 22mm O.D. plain tails - all sizes Local isolating and regulating valves are recommended. Observe the correct flow and return positions specified in the IOM instructions to ensure the rated heat output. Electrical connections A 230 Volt, single phase, 50 Hertz supply must be connected to the I.E.C. mains inlet plug. Any remote accessories must be connected as shown on the wiring diagram supplied with the heater. PRICES & CONDITIONS OF SALE Prices Dunham-Bush Ltd do not issue price lists but will be pleased to supply a written quotation upon request. Contact a Dunham-Bush Sales representative. Standard conditions of sale The standard conditions of sale appear on all quotation and order acknowledgment forms. Additional copies are available upon request SUPPLY Availability Series BM fan convector heaters are supplied direct from our manufacturing plant in Havant. The availability varies with demand and should therefore be checked at the time of ordering. Contact a Dunham-Bush Sales representative for typical lead times. Packaging Heaters are packed for storage in clean, dry indoor conditions. Each heater is marked to show the model, figure number, serial number and any reference given on the order for site identification. Ordering To allow us to process your order promptly, please refer to any quotation we have supplied and any relevant correspondence. Please send your order to the Dunham- Bush Sales representative who provided the quotation. There are two ways of providing information necessary for us to supply the required heaters 1) please photocopy the Fan convector Description Code form on page 39 and fill in your requirements or, 2) please advise the following details :- a) quantity of each model and figure number b) left or right hand coil connections as viewed looking at the access panel and air outlet c) coil type d) air vent type e) air volume flow rate and external resistance at low, medium or high speed TECHNICAL SUPPORT SERVICES Product support In the United Kingdom and Ireland, Dunham-Bush have a network of sales agents and representatives, situated at strategic locations, to provide local support on pricing and selection. Further technical support is available at Dunham Bush head office and factory in Havant. 36

TYPICAL INSTALLATION DETAIL - MODEL BM1 WITH 02 INLET/OUTLET BOXES 37

Coil capacities Approximate capacities of coils WA1, WA2, WA3 & WA4 Size Coil capacity (l) WA1, WA2 & WA3 Coil capacity (l) WA4 Fig 03 0.63 1.2 Fig 04 0.77 1.6 Fig 06 0.77 1.6 Fig 08 1.03 2.1 Fig 10 1.03 2.1 Fig 12 1.25 2.5 Fig 15 1.25 2.5 Fig 16 1.16 2.1 Fig 18 1.51 2.7 Heaters and accessories masses Item description Approximate shipping masses (kg) Fig 03 Fig 04 Fig 06 Fig 08 Fig 10 Fig 12 Fig 15 Fig 16 Fig 18 Model 1 to 8 19 25 25 33 33 37 37 45 45 Inlet and outlet box 01, 02 4 5 5 7 7 8 8 9 9 Damper box 03, 05 & 06 6 7 7 9 9 11 11 13 13 Damper box 04, 07 & 08 7 8 8 10 10 12 12 14 14 Circular spigot box SB 5 6 6 9 9 11 11 13 13 Circular spigot box SP 1 2 2 3 3 4 4 5 5 Extension duct E3 19 26 26 33 33 44 44 45 45 Loose grille & fixing frame LG & FF 2 2 2 3 3 4 4 5 5 Plinth P2 2 3 3 3 3 4 4 5 5 Rectangular spigot plate RS 1 2 2 2 2 3 3 4 4 Accessories Remote switches Flush mounting part No. Surface mounting part No. On/off 121-601-010 121-601-001 High/off/low 121-601-011 121-601-002 Man/off/auto 121-601-012 121-601-003 Man/off/auto & high/low 121-601-015 121-601-006 FAI/recirc 121-601-013 121-601-004 FAI/recirc high/off/low 121-601-016 121-601-007 FAI/recirc man/off/auto 121-601-017 121-601-008 FAI/recirc man/off/auto & high/low 121-601-018 121-601-009 Room thermostats Standard part number Tamper resistant Honeywell T6360B1028 for LPHW Coils 903-002-056 n/a Honeywell T6360B1069 for LPHW Coils n/a 903-002-057 Honeywell T4H110A1021 programable digital 903-002-071 n/a 38

SERIES BM FAN CONVECTOR DESCRIPTION CODE Use the product description code to specify the complete fan convector required Code Component Component description position 1 Product BM 2 Model 1, 2, 3, 4, 5, 6, 7, 8 3 Figure number 03, 04, 06, 08, 10, 12, 15, 16, 18 - heater size 4 Coil connections L - left hand, R - right hand 5 Connection orientation T - top facing pipework connections, B - bottom facing pipework connections, N - Electric heating 6 Coil type Standard LPHW applications - WA2 & WA3, Special applications: WA1 (LST specification & MTHW applications), WA4 (Avant-Garde specification) Electric heating applications; E15, E20, E30, E40, E50 & E60 7 Air vent N - None, M - manual, A - automatic, P - plugged 8 Motor type AC - 230V AC motor, EC1 - EC motor requiring 2-10V input, EC2 - EC motor with fitted three speed potentiometer board 9 Fan speeds Single speeds: LN - low, MN - medium, HN - high, Dual speeds: LM - low/medium, MH - medium/high, LH - low/high 10 Low temp. cut-out LTC N - none, 3 - adjustable setting LTC with 650mm double insulated cable 11 Air thermostat on/off N - none, C - capillary fitted, R - remote 12 Air thermostat high/low N - none, C - capillary fitted, R - remote 13 Switch location N - none, E - external, R - remote 14 Switch type N - none, 1 - on/off, 2 - high/off/low, 3 - man/off/auto, 4 - man/off/auto & high/low, 5 - FAI/recirc, 6 - FAI/recirc & high/off/low, 7 - FAI/recirc & man/off/auto, 15 Relay control N - none, R1-24V BMS enable, R2-24V BMS enable & speed change 16 Fitted isolating valves N - none, B - ball valve, G - gate valve, C - ball valve for use with control valve 17 Control valves N - none, 4-4-port (LST & Avant-Garde specification), 2-2-port 18 Fitted plinth N - none, 10-100mm, 15-150mm 19 Fitted duct extention N - none, E1-200-400mm, E2-450-800mm, E3-800-1600mm 20 Fitted inlet N - none, 01, 02, 03, 04, 05, 06, 07, 08, SB, SP, RS 21 Fitted outlet N - none, 01, 02, SB, SP, RS Notes 1) Please refer to accessories section for items applicable to various models. 2) Select any remote switches and/or thermostats required from table 38 3) If connection orientation is not defined on works order, pipework direction will be as illustrated in this catalogue 4) If spigot are selected and no positions specified, spigots will default to 200mm in all positions 5) There are combinations of selections which are not compatible, if in doubt consult your local agent Use the description code box, when inlet/outlet spigot box SB or inlet/outlet spigot plate SP is required. Refer to pages 31-34. 10 Ø100mm spigot 15 Ø150mm spigot 20 Ø200mm spigot 25 Ø250mm spigot 0 spigot not required Type Spigot Position Inlet SB/SP 1 2 3 4 5 6 7 Type Spigot Position Outlet SB/SP 1 2 3 4 5 6 7 39

Quality Dunham-Bush operates a quality control system and is a company of assessed capability to BS EN ISO 9001:2015 Whatever the product, wherever its eventual destination, Dunham-Bush design and manufacturing policy has always been firmly based on technical quality. Other Dunham Bush products Series AM cased fan convectors Series CM cased fan convector Series 600 ceiling tile heaters Series SL slim-line fan convectors Evolution radiant panels Evo-Lite radiant panels Dunham Strip radiant panels Lynx fan coil units Panther fan coil units Leopard fan coil units Cougar fan coil units Puma fan coil units Ocelot fan coil units Hydrocourse natural convection trench heating Aerocourse fan-assisted trench heating Finvector perimeter sill-line heating Series UH unit heaters System LST low surface temperature radiators Sentry air curtains Sentinel air curtains BS EN ISO 9001: 2015 Manufacturer reserves the right to change any product specification without notice Dunham-Bush Ltd Downley Road Havant Hampshire PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 Email: info@dunham-bush.co.uk www.dunham-bush.co.uk 40 221-000-000-D March 2018