ECO II. Economy System Typ 2. Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung

Similar documents
ECO II. Economy System Typ 2. Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung

INSTALLATION PROOF REGISTER YOUR PRODUCT. for warranty claims STAMP. Dealer. Date. here. Please complete and return. For the dental office:

REGISTER YOUR PRODUCT. for warranty claims INSTALLATION PROOF. Please complete and return

ECO MST 1. Separierautomatik MULTI SYSTEM TYP 1 ECO Gerätedokument Einbau, Betrieb und Wartung

METASYS. Amalgam separator ECONOMY SYSTEM TYPE 2 ECO II. Installation, operation and maintenance

METASYS. Amalgam Separator COMPACT A8 / A16. Installation, operation and maintenance

METASYS. Central Suction System EXCOM hybrid 2/5. Equipment Logbook Assembly, operation and maintenance

CENTRAL SUCTION SYSTEMS. Dry / semi-wet suction For 1-15 dental units Underpressure of 180 mbar

Syclone Amalgam Separator Installation and operating guide

Operating Instructions

NXT Hg5 Amalgam Separator Installation and Operations Manual

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

NXT Hg5 mini Amalgam Separator Installation and Operations Manual

Dental Unit User's Guide

Hg5 Amalgam Separator Installation and Operations Manual

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

OPERATING INSTRUCTIONS

Instruction Manual Spray Booth SK 66

Flameproof Manual Call Points

Aerosol flame projector with spark effect Safety instructions and operating manual

DÜRR SUCTION SYSTEMS. High demands reliably exceeded DÜRR AMALGAM SEPARATORS

Hg5 HV Amalgam Separator Installation and Operations Manual

BEFORE USING THE DISHWASHER/CONNECTIONS

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

Product Manual Glue Applicators MS 80 and MS 200

NEPTUN I Sole cleaning unit Art.-No.:

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

V80-H Multistage Pump Instruction Manual

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Table of Contents. English

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH HYDROPHOBIC VALVE

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH MECHANICAL VALVE

Operating Instructions

Hoshizaki America, Inc.

Operating Manual. VIENNA Hot Display

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

OPERATION AND MONTAGE MANUAL ROOF FANS

Operating Instructions. PowerFill. Automatic Granulate Conveyor for perfectmelt SE

Operating Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Operational Instructions. Glue Applicator MS Translation from German to English

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

USER MANUAL. Intelligent toilet Primus

MODEL 7000 SUCTION UNIT

Hoshizaki America, Inc.

SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX

We ve invented suction. Again. The radial Tyscor V/VS suction machine COMPRESSED AIR SUCTION IMAGING DENTAL CARE 50 % HYGIENE. potential energy saving

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:...

ANTIBACTERIAL HAND VAC WITH UV LIGHT

OPERATING MANUAL MANUAL WATER BASE GUN CLEANERS UM120W UNI-RAM CORPORATION ONTARIO CANADA PATENTS

RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P

RC411 Operator Manual

SELF-CONTAINED CRESCENT CUBER

Vacu-Mixer. Operating Instructions

Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

GB Installation instructions DÜRR Combi-Separator 7110

BarAid 400. Installation and. Starting from Serial No.:

Hoshizaki America, Inc.

Decentralised ventilation units

51AKS I S O OWNER S MANUAL

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

Operating Manual for Profident / Profident PLUS

Propane Flame Projector Safety instructions and operating manual

Coffee Machine Zia series

Operating Instructions for Reka Hot-Melt Glue Applicators

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

smardy - pure water Reverse osmosis system YR100-A 75 GPD

1 General Information about the Operating Instructions Intended Use Safety Rules Symbols used Warnings...

Instructions for use. 301 plus

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

PF50 Series Portable Filtration Systems

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.

USER S MANUAL LINCOLN PF Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

Care instructions ESTETICA E80. Always be on the safe side.

INSTRUCTIONS FOR USE. To make the most of your new oven, read the user's instructions carefully and keep them on hand for consultation in the future.

Owner's Manual TABLE OF CONTENTS

ACCUVAC Pro/ ACCUVAC Lite. Suction Device. Instructions for Use

Super Elite Watch cleaning machine

Models Goldfisch Fat Extraction Apparatus

SUPERIOR PERFORMANCE

Operating Instructions RM 90. Watch Cleaning Machine. english

SILENT compact /

User manual Flushing device VAS 6337/1a

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Cooker Hood Instruction Manual

OPERATING INSTRUCTIONS FOR THE TP18SX-HP

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Owner's Manual TABLE OF CONTENTS

B Saneo. Saneo. Saneo BS Saneo CS Saneo BW Saneo CW. C Saneo BLP Saneo CLP. Dometic Dometic. Dometic Dometic. Dometic Dometic.

OPERATION AND MONTAGE MANUAL ROOF FANS

User Manual Keep this manual safe for future reference

LED IMPORTANT SAFETY INSTRUCTIONS

Transcription:

Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung Amalgam separator ECO II/ECO II Tandem Equipment Logbook Assembly, operation and maintenance Récupérateur d amalgame ECO II/ECO II Tandem Livret d appareil Installation, fonctionnement et entretien Separatori d amalgama ECO II/ECO II Tandem Verbale d installazione Montaggio, funzionamento e manutenzione ECO II Economy System Typ 2

Index Explanation of the pictograms Practice personnel, technicians 1. Index The header on each page defines the user group particular information is aimed at. Chapter Page 1. Index 2 2. Explanation of the pictograms 2 3. General information 3 4. Application 4 5. Construction 4 6. Explanation of the type plate 4 7. Technical data 5 8. Functional description 5 9. Installation options 6 10. Replacement intervals 7 11. Installation ECO II 7 12. Installation ECO II Tandem 8 13. Hose connections between ECO II / ECO II Tandem and EXCOM hybrid central suction systems 14. EXCOM hybrid A1 / A2 / A5 suction systems with ECO II amalgam separation 15. Replacing the collection container 11 16. Disposal of the full collection container 12 17. Maintenance, cleaning and disinfection 13 9 10 2. Explanation of the pictograms i Information Caution! General warning sign Refer to instruction manual/booklet 2

General information Practice personnel, technicians 3. General information The safety, reliability and performance of the appliance is only guaranteed by METASYS if the following instructions are observed: Assembly, alterations or repairs may exclusively be carried out by authorized service personnel in compliance with Standard 60601-1 (International Standard for Medical Electrical Apparatus, in particular Part 1: General Rules for Safety). The electrical installation must comply with the regulations of the IEC (International Commission for Electrical Engineering). The appliance must exclusively be used in conformity with the instructions for installation, operation and maintenance. Only original parts may be used for repairs or replacements. All the guidelines provided by the manufacturer on the correct use of the amalgam separator must be followed. After commissioning, complete the proof of installation at the front page of this manual and send this to METASYS in order to define the warranty period. All inspection and service work must be entered into the device documentation at the first pages of this manual When requested by an authorized engineer, METASYS agrees to make all documents available for the use of technically qualified service personnel. METASYS accepts no responsibility for damages caused due to external factors, such as wrong installation, improper use of the apparatus or unauthorized technical intervention. Users must study equipment and assure themselves of its good condition before every use. Certificates of recycling for the amalgam waste (provided by recycling company) must be kept in accordance with national regulations. The equipment is not suitable for use in explosive or combustible environment. 3

Application Construction Explanation of the type plate Practice personnel / technicians 4. Application 1 ECO II The METASYS ECO II is a sedimentation amalgam separator for the installation after a central suction system or in the waste water pipe of the dental unit. When used in a liquid ring system, the ECO II can be installed in the suction line before the liquid ring pump. 5. Construction The amalgam separator ECO II consists of 2 modules: 1 Module 1 is the central mounting element and at the same time wall bracket. Module 2 is the sedimentation amalgam separator with water connections. 2.1 6. Explanation of the type plate 2 See illustration 2.1 Equipment type 2.2 Mains supply data 2.2 2.3 2.5 2.4 2.3 German Institute for Construction Technology registration number 2.4 Serial number 2 2.5 Address of manufacturer 2.5 2.6 2.1 2.2 4 3 2.3 2.4

Technical data Functional description Practice personnel / technicians 7. Technical data Separation rate 95% Collection container volume 700 cm 3 147 mm Max. ambient temperature 40 C Max. water flow rate (via air/water separation) 1 l / min Dimensions 308 x 164 x 201 mm 180mm Possible suction systems: dry-line vacuum generators with air/water separation, e.g. central suction system METASYS EXCOM hybrid. 201 mm 308 mm liquid ring systems i With the ECO II a separation rate of 95% is achieved. The use of air abrasion granulate does not affect the separation rate of the amalgam separator! 164 mm 178 mm 8. Functional description 3 4 See illustration 4.1 The amalgam separator ECO II works on the principle of sedimentation, divided into several sections. The waste water from the dental units runs from the central suction system with air/water separation into the inlet nozzle 4.1 of the ECO II. 4.4 In liquid ring systems, the water flow from the suction line into the inlet nozzle. 4.3 From there the waste water is led through the first large sedimentation chamber 4.2. Afterwards it is led through the first sedimentation cartridge 4.3, through cascades 4.4 and the second sedimentation cartridge 4.5 into the second sedimentation chamber 4.6. Through the third sedimentation cartridge 4.7 the cleaned water is led directly into the sewage pipe 4.8. 4.2 4.5 4.7 In liquid ring systems, the clean water is led into the liquid ring pump. 4.8 4.6 4 5

Installation options ECO II / ECO II Tandem Technicians 9. Installation options 1.1 The ECO II allows a variety of different installation options. It is necessary to check if the possible water input from simultaneously operated units can exceed 1 l/min. If the maximal amount of water can exceed 1 l/min or if the waste water from several units is brought together, then the ECO II Tandem must be used, if necessary with a sufficiently dimensioned expansion container. The use of ECO II D / ECO II Tandem D is mandatory in Germany. 1 1 See illustration Installation directly into the waste water pipe of the dental units The ECO II is installed after the air/water separation 1.1 directly into the waste water pipe of the dental unit. 2 See illustration Installation after a central suction system Volume of waste water <1 l/min: The ECO II is installed after the central suction system with air/water separation (waste water outlet) into the waste water pipe. 3 See illustration Installation after a central suction system Volume of waste water >1 l/min: The ECO II Tandem is installed after the central suction system with air/ water separation (waste water outlet) into the waste water pipe. 2 4 Installation in the suction line before a liquid ring pump In liquid ring systems, the ECO II and the ECO II Tandem are installed in the suction line before the liquid ring pump. 6 3

METASYS Medizintechnik GmbH Florianistraße 3 6063 Rum bei Innsbruck, Austria 1 +43 512 205420 u info@metasys.com www.metasys.com www.ecotwo.com E2-54.903/01 Replacement intervals Installation ECO II Practice personnel / technicians 10. Replacement intervals 6 Replacement intervals The maximum service life (replacement interval) of the ECO II amalgam separator results from the chosen installation option and the number of operators. Please mark the appropriate box! 6 The resulting exchange interval must be adhered to! The ECO II must be replaced as soon as the maximum filling level has been reached, or 1x a year even if the maximum filling level has not yet been reached. 7 Filling level A label on the ECO II collection container 7.1 shows the filling level (100%, 95%) The label enables the user to monitor the filling level. 6 Separator ECO II 1 2 No. of Max. service operators life (months) 1 12 2 6 3 9 4 6 5 5 6 4 i When using insoluble air abrasion powders the service life/ replacement intervals need to be defined in the applicant s responsibility considering the expected consumption of the abrasion powder. 100% 95% 100% 95% 7.1 METASYS Medizintechnik GmbH Florianistraße 3 6063 Rum bei Innsbruck, Austria 1 +43 512 205420 u info@metasys.com www.metasys.com www.ecotwo.com 7 E2-54.903/01 11. Installation ECO II 8 Mounting module 1 (mounting element/wall bracket) Slide the two mounting elements together as in the picture. 9 Fixing: Screw together at the marked spots with the supplied screws and screwnuts. For the mounting the following minimal space is required (H x W x D): 360 x 165 x 202 mm. 9.1 Position mounting element on an even floor space or fix onto wall with suitable screws 9.1. 10 Mounting module 2: 8 9 Place module 2 with the supplied bolts 10.1 onto the fixture and fasten with the screws. 11 Hose connections: 11.1 Waste water inlet: waste water from the dental unit or from the central suction system 11.2 Waste water outlet: cleaned waste water directly to the sewage pipe 10.1 11.1 The waste water must be able to drain off freely into the sewage pipe! Secure fittings and tubes with clips! 11.2 10 11 7

Installation ECO II Tandem Technicians 12. Installation ECO II Tandem 1 407 mm IN 371 mm 2 OUT 243 mm 8

Hose connections between ECO II / ECO II Tandem and EXCOM hybrid Technicians 13. Hose connections between ECO II / ECO II Tandem and EXCOM hybrid central suction systemss suction system amalgam separator min. 2% suction flow IN water OUT min. 2% ECO II max. 0,4 m suction system amalgam separator min. 2% suction flow IN water OUT min. 2% ECO II Tandem max. 0,4 m 9

EXCOM hybrid A1 / A2 / A5 suction systems with ECO II amalgam separation Technicians 14. EXCOM hybrid A1 / A2 / A5 suction systems with ECO II amalgam separation min. 2 % Model EXCOM hybrid A1 - ECO II 230 V: 02010251 Order no. - min. 2 % Model Order no. 10 EXCOM hybrid A2 - ECO II EXCOM hybrid A5 - ECO II Tandem (international) (international) 230 V: 02010221 230 V: 02010222-400 V: 02010224

Replacing the collection container Practice personnel / technicians 15. Replacing the collection container The ECO II collection container must be exchanged according to the replacement intervals as defined in the replacement interval table (cf. page 7, chapter 10). Wear protective gloves and face mask! Avoid contact with the contents of the amalgam separator! It is not possible to open the ECO II and reuse it! Every attempt to open the amalgam separator results in the malfunction of the device. Moreover, the required separation rate will no longer be achieved! 1 2 1 Remove the adapter with the tube at the waste water inlet and waste water outlet. 2 Tightly close the outlet of the full amalgam separator with the sealing plug (supplied with the amalgam separator) and secure with a clip. 3.1 3 Detach the 2 upper screws from the bolts 3.1 and take out the full amalgam separator by lifting it off upwards. 4 Position the full amalgam separator horizontally onto an even surface, make sure that the inlet opening is pointing upwards! Cut open the disinfection pouch for final disinfection (supplied with new amalgam separator) at one corner and pour its content into the inlet opening of the full amalgam separator. 5 Afterwards also tightly close the inlet opening with the sealing plug and secure with a clip. 6 Put the amalgam separator into the styrofoam shells, then place into the cardboard box. 7 Install the new amalgam separator 7.1 and secure it again by tightening the screws. 8 Reconnect the adapter with the tube to the IN and OUT openings. 3 5 4 6 Check inlet and outlet of the ECO II for tightness! 7.1 7 8 11

Disposal of the full collection container Practice personnel / technicians 16. Disposal of the full collection container Wear protective gloves and face mask! Avoid contact with the contents of the container! For technical and hygienic reasons the amalgam separator is designed for single use. The reuse of a used amalgam separator can lead to malfunction and violates the warranty regulations! The full amalgam separator can be disposed of at the in-house recycling company DTAL ECO SERVICE - METASYS Group. Certificates of recycling need to be stored according to national law. 9 The simplest method of disposal: ECO TRANSFORM! 9 See illustration Place the properly sealed amalgam separator into the two styrofoam shells. 10 See illustration Put the amalgam separator in the Styrofoam shells into the transport box (with postal certification) and close it. 11 See illustration Place the appropriate return label onto the transport box for recycling at DTAL ECO SERVICE (more information on the recycling options in your country on www.metasys.com). 10 Visit www.metasys.com or scan this QR code to receive more information about ECO TRANSFORM! 12 11 www.youtube.com/user/metasysmedizintech

Maintenance, cleaning and disinfection Practice personnel / technicians 17. Maintenance, cleaning and disinfection 1 See illustration Shortly operate the rinsing basin after every treatment! 2 See illustration Suck off some water with each of the suction tubes after every treatment. 3 See illustration: Twice a day, after having sucked off some water, use GRE&CLEAN M2, the disinfectant prescribed by METASYS, for cleaning and disinfection. GRE&CLEAN M2 should be used before longer periods of downtimes of the dental unit (e.g. lunch break, end of the working day or holidays). 1 4 See illustration The spittoon bowl should also be rinsed with GRE&CLEAN M2 twice a day. The operation of the amalgam separator ECO II without prefilter at the dental unit and/or at the central suction system is not permitted! 2 5 See illustration The amalgam residue from the prefilter box must be collected in the METASYS ECO CTER and disposed of properly with ECO TRANSFORM. 3 4 www.youtube.com/user/metasysmedizintech 5 13

METASYS... makes the difference! Visit us at: www.metasys.com METASYS Medizintechnik GmbH Florianistraße 3, 6063 Rum bei Innsbruck, Austria Phone: +43 512 205420 - Fax: +43 512 205420 7 www.metasys.com - info@metasys.com GERMANY +49 2236 37 42 42 info@metasys.com FRANCE +33 4 37 90 22 15 info@metasys.fr ITALY +39 045 981 4477 desitalia@metasys.com 2017-11 ZK-55.076/02 70100038 Druck- und Satzfehler vorbehalten! / Subject to printing and setting errors!