INSTALLATION PROOF REGISTER YOUR PRODUCT. for warranty claims STAMP. Dealer. Date. here. Please complete and return. For the dental office:

Similar documents
REGISTER YOUR PRODUCT. for warranty claims INSTALLATION PROOF. Please complete and return

ECO II. Economy System Typ 2. Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung

ECO II. Economy System Typ 2. Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung

METASYS. Amalgam separator ECONOMY SYSTEM TYPE 2 ECO II. Installation, operation and maintenance

ECO MST 1. Separierautomatik MULTI SYSTEM TYP 1 ECO Gerätedokument Einbau, Betrieb und Wartung

METASYS. Amalgam Separator COMPACT A8 / A16. Installation, operation and maintenance

METASYS. Central Suction System EXCOM hybrid 2/5. Equipment Logbook Assembly, operation and maintenance

CENTRAL SUCTION SYSTEMS. Dry / semi-wet suction For 1-15 dental units Underpressure of 180 mbar

Syclone Amalgam Separator Installation and operating guide

NXT Hg5 Amalgam Separator Installation and Operations Manual

NXT Hg5 mini Amalgam Separator Installation and Operations Manual

Hg5 HV Amalgam Separator Installation and Operations Manual

Hg5 Amalgam Separator Installation and Operations Manual

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

Hoshizaki America, Inc.

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

Hoshizaki America, Inc.

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

Aerosol flame projector with spark effect Safety instructions and operating manual

Instruction Manual Spray Booth SK 66

User information. Cleaning/descaling and sanitizing

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH MECHANICAL VALVE

SUPERIOR PERFORMANCE

OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

OPERATING MANUAL MANUAL WATER BASE GUN CLEANERS UM120W UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Operating Instructions

OPERATOR S MANUAL WET/DRY VACUUM PF51 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

USER S MANUAL ATH WH220

Page 1 of 18. Part# /5/2013

SELF-CONTAINED CRESCENT CUBER

Hoshizaki America, Inc.

KM-900MAH KM-900MWH KM-900MRH KM-900MRH3

Reliability is a beautiful thing TM CUBELET ICE DISPENSER DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF INSTRUCTION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

Table of Contents. English

Daily maintenance and checks

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH HYDROPHOBIC VALVE

PRO 2000i LOW LEVEL DEPOSITOR

Bona Portable DCS Manual and safety instructions

KML-600MAH KML-600MWH KML-600MRH

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

Surgical Suction: Silent and powerful!

Coffee Machine Zia series

hp Dust Collector With Vacuum Attachment

HOSHIZAKI MODULAR CRESCENT CUBER MODELS KM-280MAH KM-280MWH INSTRUCTION MANUAL

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

CC Series VACUUM PUMPS

SASE BULL 240C. Dust Collection System Manual

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Tornado Operations & Maintenance Manual

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Chemical resistant Vacuum Pumps

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL

Hoshizaki America, Inc.

Hoshizaki America, Inc.

ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C)

TECHNOSKLO Ltd. Držkov

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

VACUUM PACKAGING MACHINE

Part No KEMPER Filter-Master XL

OPERATING MANUAL SPRAY GUN CLEANERS UG UG3000 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Models Goldfisch Fat Extraction Apparatus

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Dental Unit User's Guide

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

Decentralised ventilation units

OPERATING INSTRUCTIONS

CAUTION UM120W (RIGHT TANK) FOR WATER BORNE PAINTS ONLY UM120W (RIGHT TANK) SECTION IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT

26/06/2018 USER MANUAL OSMOSE HOBBY GPH. All rights reserved Les Équipements d Érablière CDL inc.

Operating instructions. Web Cleaner 1 / 2. Air Line

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Light oil burners. One stage operation

SELF-CONTAINED FLAKER

Steam Vac Tubular-5, a new steam vacuum suction tool for improved slaughter hygiene on beef, sheep and pork.

OPERATING MANUAL SOLVENT SPRAY GUN CLEANERS UG5000E, UG5000DVM AND UG5500E UNI-RAM CORPORATION ONTARIO CANADA PATENTS

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Operating Instructions

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.

V80-H Multistage Pump Instruction Manual

The Flush Kit: The perfect companion to Harvest Right home freeze dryers. The Flush Kit. User s Manual

OWNER S MANUAL. Solar Collector DELUXE

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

HERCULES (110V) (220V) USER S MANUAL

Hoshizaki America, Inc.

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

OPERATING INSTRUCTIONS

Bedienungsanleitung. Ideas for dental technology. Made in Germany C

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

CIRCO 6 Solar Circulation Unit

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

Coffee Machine Zia series

Propane Flame Projector Safety instructions and operating manual

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Transcription:

REGISTER YOUR PRODUCT for warranty claims INSTALLATION PROOF Please complete and return Fax: 305 662 7479 E-mail: pwd@metasys.com Dealer Date For the dental office: Please confirm that your technician has informed you about the following important points: Product function, operation, maintenance Warranty guidelines: Keeping service intervals Operation and cleaning with preparations recommended by the manufacturer Service documentation, return of installation proof Using GREEN&CLEAN M2 daily in order to clean your ECO II amalgam separator and your evacuation system STAMP here Dental office

ECO II AMALGAM SEPARATOR PURE WATER DEVELOPMENT LLC Equipment Logbook Assembly, operation and maintenance PURE WATER DEVELOPMENT LLC LEADING COMPANY IN AMALGAM SEPARATION TECHNOLOGIES

Equipment logbook ECO II Separator and Replacement Canister to be filled in by the technician service and maintenance must be carried out as per the instructions for the installation, operation and maintenance Date of container replacement Dealer Other maintenance activities Date of container replacement Dealer Other maintenance activities Date of container replacement Dealer Other maintenance activities Date of container replacement Dealer Other maintenance activities Date of container replacement Dealer Other maintenance activities 2

Index Explanation of the pictograms General information Office personnel, technicians 1. Index 3. General information The header on each page identifies the user group each page is written for. Chapter Page 1. Index 2 2. Explanation of the pictograms 2 3. General information 3 4. Application 4 5. Construction 4 6. Explanation of the type plate 4 7. Technical data 5 8. Functional description 5 9. Installation options 6 10. Replacement intervals 6 11. Installation ECO II 7 12. Installation ECO II Tandem 8 13. Hose connections between ECO II / 9 ECO II Tandem and EXCOM hybrid dry vacuum systems 14. EXCOM hybrid A1 / A2 / A5 dry vacuum 10 systems with ECO II amalgam separation 15. Replacing the collection container 11 16. Disposal of the full collection container 12 17. Maintenance and cleaning 13 2. Explanation of the pictograms The safety, reliability and performance of the appliance is only guaranteed by PURE WATER DEVELOPMENT if the following instructions are observed: Assembly, alterations or repairs may exclusively be carried out by authorized service personnel in compliance with EN Standard 60601-1 (International Standard for Medical Electrical Apparatus, in particular Part 1: General Rules for Safety). The appliance must exclusively be used in conformity with the instructions for installation, operation and maintenance. Only original parts may be used for repairs or replacements. All the guidelines provided by the manufacturer on the correct use of the amalgam separator must be followed. Following the commissioning of the amalgam separator, the Installation Proof must be completed and returned to PURE WATER DEVELOPMENT to establish the guarantee period. Every inspection and servicing must be recorded in the Equipment Logbook. When requested by an authorized engineer, PURE WATER DEVELOPMENT agrees to make all documents available for the use of technically qualified service personnel. PURE WATER DEVELOPMENT accepts no responsibility for damages caused due to external factors, such as wrong installation, improper use of the apparatus or unauthorized technical intervention. i Information Caution! Users must study equipment and assure themselves of its good condition before every use. Certificates of recycling for the amalgam waste must be kept in accordance with national regulations. General warning sign The equipment is not suitable for use in explosive or combustible environment. Gebrauchsanweisung beachten 3

Application Construction Explanation of the type plate Office personnel / technicians 4. Application 1 ECO II The ECONOMY SYSTEM TYPE II (ECO II) is a sedimentation amalgam separator. When used in a wet ring system, the ECO II can be installed in the vacuum line before the wet ring pump. 5. Construction ECO II combines the amalgam separator and the collector tank in one. This means that once the device is completely filled with amalgam waste, the entire ECO II is replaced. 1 6. Explanation of the type plate 2.5 2.6 2.1 2.2 2 See illustration 2 Economy System Type 2 ECO II amalgam separator air flow max = 400 gal/min, 1514l/min water flow max =0,264 gal/min, 1l/min patent pending METASYS Medizintechnik GmbH 6063 Rum bei Innsbruck, Florianistraße 3, Austria 1+43/(0)512/205420-0 5 +43/(0)512/205420-7 Distributed by PureWay Compliance, Inc. www.pureway.com (877) 765-3030 2.3 2.4 Made in Austria The type plate is located directly on the front side of the amalgam separator. 2.1 Equipment type 2.2 Serial number 2.3 Manufacturer s address 2.4 Distributor s address 2.5 Max. suction volume 2.6 Max. water flow rate 4

Technical data Functional description Office personnel / technicians 7. Technical data Low pressure range Separation rate Collection container volume Max. ambient temperature Possible vacuum systems Max. air flow rate Max. water flow rate Dimensions (H x W x D) Exchange interval 50 mbar - 300 mbar 99% in accordance with ISO 11143 0.4 gal (1.5 liters) 4.5 lb (ca. 2 kg) 0.18 gal (700 ml) amalgam wastes 104 F wet or dry 400 gal/min, 1,514 l/min 0.264 gal/min, 1 l/min 12.2 x 7.7 x 8.4 in (309 x 196 x 213 mm) approx. 12 months 3.1 3.4 3.2 3.3 3.5 3.7 Possible vacuum systems: dry vacuum system with air/water separation, e.g. dry vacuum system METASYS EXCOM wet ring systems 3 3.8 3.6 8. Functional description 3 See illustration The amalgam separator ECO II works on the principle of sedimentation, divided into several sections. With dry vacuum systems the waste water from the dental units runs from the air/water separation tank into the inlet nozzle 3.1 of the ECO II. In wet ring systems, the water flow from the suction line into the inlet nozzle. From there the waste water is led through the first large sedimentation chamber 3.2. Afterwards it is led through the first sedimentation cartridge 3.3, through cascades 3.4 and the second sedimentation cartridge 3.5 into the second sedimentation chamber 3.6. Through the third sedimentation cartridge 3.7 the cleaned water is led directly into the sewage pipe 3.8. In wet ring systems, the clean water is led into the wet ring pump. 5

Amalgam waste for recycling 100% 95% METASYS Medizintechnik GmbH Florianistraße 3 6063 Rum bei Innsbruck, Austria 1 +43 512 205420 u info@metasys.com www.metasys.com www.ecotwo.com E2-54.906/01 Installation options ECO II / ECO II Tandem Replacement intervals Technicians 9. Installation options The ECO II allows a variety of different installation options. Please check if there is a wet ring / water ring vacuum system or a dry vacuum system. wet ring pump 1 See illustration Installation in the suction line before a wet ring pump In wet ring systems, the ECO II and the ECO II Tandem are installed in the vacuum line before the wet ring pump. 1 2 See illustration Installation with a dry vacuum system: The ECO II / ECO II Tandem can be installed before (option 1) or after (option 2) the air/water separation tank (waste water outlet). option 1 separation tank dry vacuum system drain option 2 2 3 Amalgam waste for recycling 100% 95% METASYS Medizintechnik GmbH Florianistraße 3 6063 Rum bei Innsbruck, Austria 1 +43 512 205420 u info@metasys.com www.metasys.com www.ecotwo.com E2-54.906/01 10. Replacement intervals 3 Filling level As soon as the solid content of the collection container has reached the maximum filling level, the ECO II must be replaced. However it has to be replaced at least once a year even if the maximum filling level has not yet been reached. 6

Installation ECO II Office personnel / technicians 11. Installation ECO II 7 Mounting element/wall bracket Slide the two mounting elements together as in the picture. 8 Screw together at the marked spots with the supplied screws and screw-nuts. For the mounting element, the following minimal space is required (H x W x D): 14.2 x 7.9 x 9 inches or 360 x 165 x 202 mm. Position mounting element on an even floor space or fix onto wall with suitable screws 8.1. 8.1 9 The readily assembled mounting element has to be fixed on a suitable place on the wall using appropriate screws 9.1. Position the device on the guiding studs of the mounting element and fasten with screws. Care must be taken that the mounting element is positioned vertically above the level of the suction machine. 7 8 10 Hose connections: 9.1 10.1 10.1 Waste water inlet: waste water from the dental unit or from the central evacuation system 10.2 Waste water outlet: cleaned waste water directly to the sewage pipe 9 10 10.2 In order to guarantee a trouble-free connection of different sizes of hoses, hose adapters supplied along with the device must be inserted in the inlet and outlet openings.in any case ensure that all connections are properly secured! The waste water must be able to drain freely into the sewage pipe! 7

Installation ECO II Tandem Technicians 12. Installation ECO II Tandem 1 OUT 8 2

Hose connections between ECO II / ECO II Tandem and EXCOM hybrid Technicians 13. Hose connections between ECO II / ECO II Tandem and EXCOM hybrid dry vacuum systems suction system suction flow IN amalgam separator min. 2% water OUT min. 2% ECO II max. 15 in suction system amalgam separator min. 2% suction flow IN water OUT min. 2% ECO II Tandem max. 15 in 9

EXCOM hybrid A1 / A2 / A5 with ECO II amalgam separation Technicians 14. EXCOM hybrid A1 / A2 / A5 dry vacuum with ECO II amalgam separation min. 2 % Model EXCOM hybrid A1 - ECO II 230 V: 02010251 Order no. - min. 2 % Model Order no. 10 EXCOM hybrid A2 - ECO II EXCOM hybrid A5 - ECO II Tandem (international) (international) 230 V: 02010221 230 V: 02010222-400 V: 02010224

Replacing the collection container Office personnel / technicians 15. Replacing the collection container The ECO II collection container must be exchanged according to the replacement intervals as defined in the replacement interval table (cf. page 7, chapter 10). Wear protective gloves and face mask! Avoid contact with the contents of the amalgam separator! It is not possible to open the ECO II and reuse it! Every attempt to open the amalgam separator results in the malfunction of the device. Moreover, the required separation rate will no longer be achieved! 1 2 1 Remove the adapter with the tube at the waste water inlet and waste water outlet. 2 Tightly close the outlet of the full ECO II with the sealing plug (supplied with the amalgam separator). 3.1 3 Detach the 2 upper screws from the bolts 3.1 and take out the full amalgam separator by lifting it off upwards. 3 4 4 Position the full amalgam separator horizontally onto an even surface, make sure that the inlet opening is pointing upwards! Cut open the sanitizing pouch (supplied with new amalgam separator) at one corner and pour its content into the inlet opening of the full amalgam separator. 5 Afterwards also tightly close the inlet opening with the sealing plug. 6 Put the amalgam separator into the plastic liner (supplied with the new amalgam separator), place it into the styrofoam shells and then into the cardboard box. 5 6 7 Install the new amalgam separator 7.1 and secure it again by tightening the screws. 8 Reconnect the adapter with the tube to the IN and OUT openings. 7.1 Check inlet and outlet of the ECO II for tightness! Suck in a large quantity of water (at least 0.5 gal or 2 l) to check the system for leakages. If leakages are found, check the hose connections. 7 8 11

Disposal of the full collection container Office personnel / technicians 16. Disposal of the full collection container Wear protective gloves and face mask! Avoid contact with the contents of the container! For technical and hygienic reasons the collection container is designed for single use. The reuse of a used container can lead to malfunction and violates the warranty regulations! The disposal of the full amalgam separator will be handled by PURE WATER DEVELOPMENT. 9 Certificates of recycling need to be stored according to national law. 9 See illustration Place the properly sealed amalgam separator into the plastic liner and then into the two styrofoam shells. 10 See illustration Put the amalgam separator in the styrofoam shells into the box and close it. 10 11 See illustration Request the prepaid return shipping label at www.ecotwo. com > Return label. Then attach the label onto the box and send it to PURE WATER DEVELOPMENT / MRI Recyclers Int. for recycling (more information visit www.ecotwo.com > Recycling). 12 11 www.youtube.com/user/purewaterdevelopment

Maintenance and cleaning Office personnel / technicians 17. Maintenance and cleaning 1 See illustration Shortly operate the rinsing basin after every treatment! 2 See illustration Suck off some water with each of the suction tubes after every treatment. 3 See illustration: To ensure optimal functioning of the device and high material compatibility, use GREEN&CLEAN M2 for maintenance and cleaning of the ECO II. GREEN&CLEAN M2 should be used before longer periods of downtimes of the dental unit (e.g. lunch break, end of the working day or holidays). 1 4 See illustration The spittoon bowl should also be rinsed with GREEN&CLEAN M2 twice a day. 2 3 www.youtube.com/user/metasysmedizintech 4 13

PURE WATER DEVELOPMENT LLC 5001 SW 74th Court, Suite 206 Miami, FL-33155 Phone: 305 663 2989 Fax: 305 662 7479 E-mail: pwd@metasys.com www.ecotwo.com 12-2017 ZK-55.221/10 70100325 Subject to printing and setting errors! For more information about PURE WATER DEVELOPMENT LLC, please visit www.ecotwo.com