Buffer Tank FWSS 1000 V7-RH

Similar documents
Fresh Water Station FWS 20 / FWS 30. Manual. Masterpieces. Art.-Nr.: (V1.0) of Solar Technology

Domestic Hot Water Tank

Installation and instruction manual SOLAR STATION

Manual SLM50HE.

PRODUCT INFORMATION. Technical description. Hygienic stratification storage tank HSK ÖKO Universal heat center for legionella safe preparation of DHW

Installation instructions

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Friwa Compact. Operating instructions EN

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

General Terms and Conditions of Connection and Warranty

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

Pro-Clean Stratified Tank scope of delivery:

PRODUCT INFORMATION. Solar DHW storage tank SKL. Technical description. High performance solar tank, bivalent

The world s most advanced direct electric water cylinder

Compressed Air Filtration Oil/water separator for compressed air condensate ultrafilter International UFA-AC

user manual Dishwasher ESL 46510

New. Double-basket pass-through dishwashers DV DV PW PowerWash Group. Automatic hood, GiO-Module,

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Installation manual Operating instructions

Heating with wood pellets kw

NEW. Group. Front loading models EcoStar 430 F / 530 F Pass-through model EcoStar 545 D. Dish- and glass washing machines of the EcoStar-Line

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance

User & Installation instruction

Manual and installation instructions. Function. Operating phase

Operating Instructions!

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Heating with log wood

ph Measuring System Start-up and maintenance manual e Contents

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

Installation and operating instructions. DK energy storage and DK energy buffer

4FLOOR-STANDING GAS CONDENSING BOILERS

WATER HEATERS INSTALLATION MANUAL

IST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK

SUN EQUINOX HEATING SYSTEMS

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions

STREBEL S-CB + Cascade Kits

HELMUT KÄMPKEN GMBH OPERATING MANUAL

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

OPERATING INSTRUCTIONS with safety features

Wood logs boiler with a gasication eect IGNIS KW. INSTRUCTIONS MANUAL for usage and maintenance

CIRCO 6 Solar Circulation Unit

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

DIGITAL MODULATING BOILERS

WZS series. Hot water circulation systems for energy storage tanks

TERMO Combi Cylinder TECHNICAL INFORMATION

Operating and assembly manual: Electric instantaneous flow heater Admiral

OPERATING AND INSTALLATION MANUAL

6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0

OPERATING AND INSTALLATION MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS

SEALED THERMAL STORE

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Forward-looking and energy effi cient Biomass heating

The First Name in Kickspace Heaters

Laddomat. Mixing valves for solid fuel boilers. Version 1.01

FAVORIT VI EN DISHWASHER USER MANUAL.

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

TS RD 7761 RD, 7761 RD

AQVA ULTRA Faucet Purifier AQ003-1 User s Guide

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Blender. brushed stainless steel housing BTBL55

Sanitary Water Tank INSTALLATION & SVC MANUAL

WH-TD20B3E5 WH-TD30B3E5

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

Solar heating systems

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Residential heating and domestic hot water. Customized heat transfer solutions

InfraTec Premium. Assembly and operating instruction. 20 min. Made in Germany. Druck Nr en/ :00 20 C

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

Installation & Operating Instructions

TACOTHERM FRESH PETA / PETA X

Sargasso Range. Installation manual. Sargasso A. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

Operating Manual Oil Water Separator CSD3 - CSD160 Version: 12/2013/DE

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

Installation Manual SPA BROADWAY MAXI

Operation Manual. Control TJ-HRC

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

SECTION 4. Parts Management

Filius Control. Installlation and operating instruction MADE IN GERMANY. print no.: en / 06.15

HEALTH & SAFETY AND INSTALLATION GUIDE

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

INSTALLATION AND OPERATION MANUAL

Instructions for Operation and Maintenance of Containers

Flow Factor ~

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

Audible warning devices for external alarm

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS,

Cistern-fed water heating

Hot water circulation system WZS 100

HT V2 HT Split

Hydronic Expansion Tanks THE ONE THAT STARTED IT ALL

Transcription:

Buffer Tank FWSS 1000 V7-RH Manual Art.-Nr.: 700119 (V1.0)

Table of content 1. Preface 3 1.1 Usage 3 1.1.1 Usage example Fresh Water Station 3 2. Description 4 3. Warning notices 4 4. Design of the Fresh Water Station 4 5. Scope of delivery 5 6. Safety precautions 6 7. Installation and initiation 7 7.1 Installation 7 7.2 Positioning of buffer tank 7 7.3 Mounting of insulation 7 7.4 Initiation 9 8. Technical data 9 9. Terms of guarantee 10 2 Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice.

1. Preface Prior to operation, please read the instructions and pay particular attention to the warning notices in chapter 3. Inappropriate use may lead to system damages. 1.1 Usage The FWSS is responsible for loading, storing and distributing thermal energy. It boasts connections for solar stations, stratifi ed layering modules, heating circuit units, fresh water systems, various heat sources and add-on buffer tanks. 1.1.1 Usage example Fresh Water Station fl oor heating radiator thermal collector heating circuit group low temperature heating circuit group high temperature heater solar station fresh water station without circultion unit system puffer tank 1 Plate heat exchanger 30 Lock valve 2 Bypass pipe 31 Pressure-reducing valve 3 Thermostatic 3-way valve 32 Drain valve 4 Charge pump Fresh Water Station 33 Backfl ow preventer 5 Stop valve buffer fl ow 34 Manometer 6 Flow-Switch 35 Expansion vessel 7 Non-return valve 36 Drain 8 Regulation 37 Safety relief valve 9 Stop valve buffer return 38 Heating pump heating device 10 Stop valve hot water 39 Bleeding vessel 12 Stop valve hot water 40 Tap connection 13 Stop valve cold water Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice. 3

2. Description The FWSS is a comprehensive heating system solution which is hydraulic and electric ready-for-connection. A heating source independent layered buffer tank, patented hygienic hot water generation and integrated high- and lowtemperature heating circuit groups all combined in one aligned system. 3. Warning notices The FWSS does not have a corrosion protection and may only be used in closed heating systems as layered buffer tank. Installation and operation must be performed according to regional regulations and common practice. Installation, maintenance and cleaning must be conducted by a qualifi ed professional. Any unauthorized alteration or change is forbidden due to security reasons and inevitably leads to the loss of any guarantee. The max. operating pressures on the type plate must not be exceeded! At the occurrence of malfunctions regardless of nature please contact your installer for heating systems. Please do not perform any unauthorized repairing, it is forbidden and can lead to unexpected dangers. 4. Design of the Fresh Water Station The depicted picture is symbolic and can marginally differ from your FWSS! 4 Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice.

5. Scope of delivery Description Buffer tank Illustration Description ¾ plastic rosettes - 4 pieces (600/800 litre FWSS) - 5 pieces (1000 litre FWSS) Illustration 1 plastic rosettes - 2 pieces Blind caps, gaskets - 4 per item 1 ¼ plastic rosettes - 8 pieces Sensor clamping plates - 3 pieces Insulation front part - 1 piece Foam rosettes - 9 pieces (1000 litre FWSS) Insulation rear part - 1 piece Flexible foam ring Covering strips - 2 pieces Thermoformed top cover - 1 piece Insulation caps - 9 pieces (1000 litre FWSS) Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice. 5

6. Safety precautions The assembly, maintenance and cleaning must only be accomplished by qualifi ed technical professionals. The installation and operation must be performed according to regional regulations and laws, common practice and according to the directives of the local water utility. DIN 1988 Drinking water supply systems DIN 4708 Central heat- water-installations; terms and calculation-basis DIN EN 12828 Heating systems in buildings - design of water-based heating systems DIN 4753 Water heaters and water heating installations for drinking water and service water DIN 4757 Solar heating plants operating on organic heat transfer media; requirements relating to safe design and construction DIN 18380 German construction contract procedures - Systems for heating and central water heating DIN 18381 German construction contract procedures - Gas, water and sewage plumbing works inside of buildings DIN 18382 Contract procedures for buildings works - low-voltage installation and medium-voltage installation with nominal voltages up to including 36 kv DIN EN 12975 Thermal solar systems and their components VDE 0100 Low-voltages electrical installations VDE 0185 Lightning protection components (LPC) VDE 0190 Main equipotential bonding of electrical systems ÖNORM EN ISO 9488 Solar energy vocabulary (ISO 9488:1999) ÖNORM ENV 12977-1 Thermal solar systems and components - custom built systems - part 1: general requirements ÖNORM M7700 Solar energy - therms with defi nitions ÖNORM M7701 Solar energy installations; approximative calculation method for the dimensioning of fl at collectors in domestic hot water systems ÖNORM M7731 Solar heating systems for heating of water - requirements and tests 6 Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice.

7. Installation and initiation Before you install your FWSS, please pay attention to the following points: Read all chapters and especially the warning notices in chapter 3. The operation of this device is not allowed to persons (including children) with limited physical, sensory or intellectual abilities. Uninformed or unacquainted persons may operate the device only under the supervision or at the trained person s disposition. Installation and operation must be performed according to regional regulations and laws. 7.1 Installation The setting up and installation must be carried out by an approved professional crafts enterprise. It is also responsible for a proper installation and initiation. As a location for installation the device requires a frost-free room which has enough room for maintenance. The FWSS needs to be installed splash-proof and may only be operated at room temperatures under 40 C. 7.2 Positioning of buffer tank Before installing the FWSS, make sure that the fl oor has an adequate bearing strength. There should be at least 10 cm space between wall and FWSS. 7.3 Mounting of insulation Take care that the insulation is mounted according to requirements; otherwise increased heat loss can occur. Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice. 7

Step 1 Step 2 Position insulation front part on the connections and place it on the tank Position insulation rear part at the 1 ½ connections and place it on the tank Connect rear and front insulations with the fi rst snap-fi t on the insulations Completely connect the snap-fi ts on the opposite side Also completely connect the fi rst connection Step 3 Step 4 Place covering strips on the insulation Place fl exible foam ring into the upper opening and cover it with the thermoformed top cover Fix the foam rosettes onto the 1 ½ connections Plug the insulation caps into the 1 ½ connections Fix plastic rosettes on tank 8 Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice.

7.4 Initiation The initiation must be carried out by an approved professional crafts enterprise. During the initiation process the unproblematic operation and leak-tightness of the whole installation, including the preinstalled connections, has to be tested. The fi lling and rinsing process has to be continued until the system is completely de-aerated. The buffer tank must not exceed a operating temperature above 95 C. 8. Technical data Model 1000 Net capacity 890 Liter Diameter insulated 994 mm Diameter non-insulated 790 mm Height insulated 2110 mm Height non-insulated 2040 mm Weight 180 Admissible operating temperature heating 95 C Admissible operating pressure 3 bar Admissible operating temperature solar loop 110 C Admissible pressure solar loop 10 bar Heating surface area solar heat exchange 3 m 2 Volume solar heat exchanger 19,8 Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice. 9

9. Terms of guarantee The manufacturer issues a guarantee of 2 years from the invoice date on the device and its constituent parts. Without proper installation and use of the device the guarantee is void. Any unauthorized alteration or change is forbidden due to security reasons and inevitably leads to the loss of any guarantee. 10 Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice.

Notes Manual Buffer Tank 1000 V7-RH. E & OE, subject to change without notice. 11

Contact SEG Solar Energy GmbH Rosenheim 111 A-9805 Baldramsdorf www.solarsales.eu