DIGI-VAV APPLICATIONS

Similar documents
BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

DIGI-CRAC DIGI-CRAH South 59 th Street Omaha, NE bes- tech.net

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

HVAC Controls Upgrades: Requirement Details ( )

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

SEQUENCE OF OPERATIONS

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

HVAC Controls Upgrades: Requirement Details ( )

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

10+ HVAC Troubleshooting Tips for Healthcare Facilities Jerry Hirsch JCI Facility O&M Performance Development Manager.

Energy Recovery with Cooling and Heating Model ERCH

Civil Engineering Building

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

Implementation of the Laboratory Air Handling Unit Systems (LAHU)

Designing Energy Efficient Outdoor Air Systems

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

photo by PFC Price Fan Column

Computing Services Center

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Technical Assignment 3 11/15/04. Executive Summary

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

b.) Technical Information:

Agenda and Objectives

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

Temperature. In the HVAC area, we talk about two kinds of temperatures.

Digital Precise Air Control - DPAC

York 25-Ton VAV Rooftop Unit

Energy Recovery with Cooling and Heating

Auburn University Basketball Arena:

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

An HVAC Audit of the Canberra Institute of Technology

Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation

IAQ: Re-tuning Commercial Buildings

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Physical Plant Complex

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

The ultimate fresh air solution.

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Song Deng, P.E. Assistant Director Energy Systems Laboratory Texas A&M University College Station, TX

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Appendices. Included in this section are

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

Agenda and Objectives

THE ULTIMATE ROOFTOP SOLUTION

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

Continuous Commissioning Report

Product Release Summary

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

Bill McCullough. Director ERV Products. Dallas, TX

HVAC Mandatory Provisions Part II, Page 1

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Harrington Tower Building

To: Steve Ardolf, MSU Mankato From: Chris Plum, CEE. CC: Tim Ellingson, CEE. Angela Vreeland, CEE Dan Briese, MSU Mankato Date: April 21, 2014.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

High-Performance VAV Systems

September 19, 20, 2009 Fort Lee, VA

Summary Comparison of Simulation Program Features

Description of All Alternatives Considered-

The M & V Guided Recommissioning Process. Energy & Water Conservation Program. September 2015 MOO

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Daikin Blueprint: Delivering Hot Water with a Chiller

Design Standard. Thermal Systems (Chilled Water and Hot Water Systems) Detailed specifications follow. CHW AND HHW SUPPLY TEMPERATURE RESET

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

BAS Point Trend Data Guidance

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

DEMAND CONTROLLED VENTILATION WITHOUT WIRES

Energy Recovery Ventilators

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Siemens Thermostats. RDY2000BN Thermostat

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

APPLICATION GUIDE BEAMS

Reference Guide for Microprocessor Controller

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

Agenda and Objectives

4. OVERVIEW OF MECHANICAL SYSTEM

Product Data. 75 to 150 Nominal Tons

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Zoned Rooftop Systems. Light commercial packaged rooftop systems from Trane

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Transcription:

DIGI-VAV

DIGI-VAV APPLICATIONS Digi-VAV: An optimization kit for Variable Air Volume Air Handling Units (VAV AHU) that ensures individual zone indoor air quality (IAQ), and minimizes system energy consumption. AHU: Single duct VAV system Dual duct VAV system Roof top VAV system Roof top DX VAV system Control System: Any DDC control system 402.502.2340 bes-tech.net

HOW IT WORKS Measure /Receives Fan airflow control using patented technology CO2 measurement of supply air, outside air, and return air Supply air and outside air temperature from BAS Calculates Supply air freshness and freshness set-point Zone fresh air needs and minimum airflow set-point Supply static pressure and air temperature set-point Reset /Controls Terminal box minimum airflow set-point Supply air temperature set-point Static pressure set point or airflow set-point Reset outside air damper position Optimizes the On/Off sequencing of the compressor 402.502.2340 bes-tech.net

DIGI-VAV CASE STUDY 134,000 square feet medical facility in Omaha, NE. Built in 2009 Two SDVAV AHUs with Fan Wall Hot water pump with VFD Siemens Apogee Digi-VAV Implemented 2010 Equipment Energy Savings Percentage Fan (kwh) 484,000 63 HW Pump (kwh) 15,600 71 CHW (tons) 258,000 48 Steam (therm) 24,900 40 402.502.2340 bes-tech.net

Without Digi-VAV With Digi-VAV With Digi-VAV With Digi-VAV 402.502.2340 bes-tech.net

BENEFIT Minimal Investment No individual CO 2 room sensors Works with any existing DDC control systems Minimal installation process /time Excellent Zone IAQ Complies ASHRAE Standard 62.1 Complies CA Tile 24 Highest Energy Efficiency Decreases heat/reheat energy consumption between 30-80% Deceases cooling energy consumption between 10-50% Reduces fan power consumption between 30-80%

BENEFIT Minimum Maintenance Cost and Effort Reduce DX cycling by 70% No zone damper hunting and over pressurization Work under existing control system No individual CO 2 room sensors

DIGI-VAV PRINCIPAL optimized air flow for large single duct VAV systems

CFM TERMINAL BOX MINIMUM AIRFLOW Traditional Minimum airflow set at a constant design level meeting IAQ requirements in worst case scenario. (typical 30% of design maximum airflow) When the actual space load drops below the design minimum, it creates an oversupply of conditioned air. This consumes needless re-heat and cooling energy. Digi-VAV Digi-VAV measures the actual supply air freshness with CO 2 sensors in the outside, return & supply air ducts, that reset terminal box minimum airflows through the BAS. When building occupancy is low or in economizer mode, the supply-air freshness is high. The total required airflow to the room can be lowered and still achieve the required amount of fresh air. While reducing or eliminating simultaneous heating and cooling. 7/15/2015

FAN SPEED CONTROL Traditional Fan control set at a constant static pressure. At partial loads, the space requires less airflow, the system curve moves to left and rests at an inefficient point on the fan curve. Running the fan at a higher speed than necessary. Digi-VAV As actual measured space load changes, Digi-VAV resets the static pressure to remain on the optimal point of the system curve. Fan speed is adjusted to remain on the optimal system curve while continuing to deliver the required air flow but more efficiently. 7/15/2015

OUTSIDE AIR INTAKE CONTROL Traditional Supply constant minimum outside air based on design occupancy. At partial occupancy, excessive outside air is supplied to the space wasting heating and cooling energy. Digi-VAV Resets the minimum outside air to a lower value when building occupancy is low, saving heating and cooling energy.

COMPRESSOR STAGING CONTROL Traditional Stages the compressor(s) to maintain a constant supply air temperature (typically 55º F). Causes compressor(s) short cycling and system inefficiency during partial loads. Condenser and evaporator are partially utilized under partial load conditions Digi-VAV Stages compressor(s) based on supply air temperature high/low limits and measured supply airflow. When supply air temperature is higher than the high limit or supply airflow is high, compressor(s) are staged up. When supply air temperature is lower than low limit or supply air flow is lower than low limit, compressor(s) are staged down. Reduces compressor(s) short cycling and improves system efficiency saving energy.

ECONOMIZER CONTROL Traditional Maintain mixed air temperature set point to avoid mechanical cooling when outside air temperature is lower than 60F (adjustable) for DX unit. Digi-VAV Maintain the supply air temperature at the set point by modulating the outside air damper when the outside air temperature is lower than the set point. No mechanical cooling occur. Low economizer range to avoid compressor hunting Modulate both outside air damper and staging to maximize the free cooling and ensure smooth compressor staging when the outside air temperature is higher than the set point and the enthalpy is lower than the room air enthalpy.

FAQ How does Digi-VAV save energy? Digi-VAV dynamically resets minimum airflow of each terminal box based on the supply air quality and zone occupancy status. This allows lower and more accurate minimum airflow set-point, reducing needless heating and cooling at the terminal box Digi-VAV dynamically resets the supply duct static pressure based on measured building load. Digi-VAV lowers the duct static pressure set-point allowing the fan to run at lower speeds Digi-VAV perform DCV plus function to minimize outside air intake during hot summer and cold winter Digi-VAV double the free cooling for DX units 4025022340 bes-technet

FAQ Does Digi-VAV communicate with the AHU controller or terminal box controller? No, Digi-VAV communicates with the BAS controller providing revised set-points for supply static pressure, minimum OA damper, and terminal box minimum airflow Do the existing supply fan VFDs need to be replaced? No Where is the Digi-VAV mounted? Inside the mechanical room or next to the AHU Install time for the Digi-VAV unit? 3 hour installation plus 30-minute per terminal box programing 4025022340 bes-technet