An Experimental and Theoretical Study on System Performance of Refrigeration Cycle Using Alternative Refrigerants

Similar documents
Air-Cooled Heat Exchanger Performance for R410A

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Study of R161 Refrigerant for Residential Airconditioning

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

Low GWP Refrigerants for Air Conditioning Applications

Efficiency of Non-Azeotropic Refrigerant Cycle

Experimental Study on the Performance of Twisted Capillary Tube

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Heat Transfer Characteristics and Heat Exchanger Performances for R407C Using Herringbone Heat Transfer Tube

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Investigation of Evaporator Performance with and without Liquid Overfeeding

Purdue e-pubs. Purdue University

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

R32 Compressor for Air conditioning and Refrigeration applications in China

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Two-Phase Evaporation Pressure Drop Experimental Results for Low Refrigerant Mass Flux

High Efficiency R-134a Compressor for Domestic Refrigerator

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

The Development of the Energy-Saving Technology by the Composition Control of R407C

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Experimental Study on Fractionation of R-407C and Recharge Operations

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Performance of CO2 Cycles with a Two-Stage Compressor

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Extremely Low Refrigerant Charge Beverage Display Cooler Technology Using Propane

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Effect of magnetic field on the performance of new refrigerant mixtures

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Performance Testing of Unitary Split-System Heat Pump with an Energy Recovery Expansion Device

Dynamic Simulation of Liquid Chillers

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Tribology Characteristics of HFO and HC Refrigerants with Immiscible Oils - Effect of Refrigerant with Unsaturated Bond -

A Performance-Enhancing Additive for Vapor- Compression Heat Pumps: Additional Test Results

Experimental Investigation Of A New Low- Approach Evaporator With Reduced Refrigerant Charge

Quantification of Liquid Refrigerant Distribution in Parallel Flow Microchannel Heat Exchanger Using Infrared Thermography

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

TERNARY ZEOTROPIC MIXTURE WITH CO 2 COMPONENT FOR R-22 HEAT PUMP APPLICATION

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Full and Partial Load Performances of RAC and CAC Heat Pump using R-32

Modeling and Testing of an R-23/R-134a Mixed Refrigerant System for Low Temperature Refrigeration

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

The Effect of Inner Grooved Tubes on the Heat Transfer Performace of Air-Cooled Heat Exchangers of Co2 Heat Pump System

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Numerical Evaluation of Performance Curves of a High Frequency Microcompressor

Experimental Study of Two-phase Seperators for Vapor Compression Systems in Household Appliances

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Oil Return Measurements In A Unitary Split System Air Conditioner Using Different Refrigerant Mixtures

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 1996 An Experimental and Theoretical Study on System Performance of Refrigeration Cycle Using Alternative Refrigerants M. Kurokawa K. Nasako M. Honjo M. Osumi Follow this and additional works at: http://docs.lib.purdue.edu/iracc Kurokawa, M.; Nasako, K.; Honjo, M.; and Osumi, M., "An Experimental and Theoretical Study on System Performance of Refrigeration Cycle Using Alternative Refrigerants" (1996). International Refrigeration and Air Conditioning Conference. Paper 327. http://docs.lib.purdue.edu/iracc/327 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

An Experimental and Theoretical Study on System Performance of Refrigeration Cycle using Alternative Refrigerants M. Kurokawa, K. Nasako, M. Honjo and M. Osumi, Ltd. ABSTRACT In this paper, characteristics of the evaporator and the capillary tube using R-41A, one of the most promising alternatives to R-22, are measured and realistic models are formulated. In addition a simulation based on these models has been carried out to investigate the system performance with R-41A. Finally the cycle characteristics of both refrigerants are compared. The SEER of systems using R-41A and R-22 can be recognized as almost the same. INTRODUCTION CFCs was phased out at the end of 199 and the regulation ofhcfcs starts in 1996. HFC blends, such as R- 41A(R-32(wt%)/R-12(wt%)) and R-47C(R-32(23wt%)/R-I2(2wt%)/R-134a(2wt%)), are regarded as promising candidates to replace R-22, now frequently used as refrigerant in air-conditioners. In particular, R-41 OA seems to be an interesting alternative to R-22, due to its energy efficiency, but the COP of the former is -1% lower than that of the latter at several working pressure levels in a theoretical cycle. (Each compressor efficiency is assumed to be constant.) In Table 1 one example of the COP of R-22 and R-41A, respectively, is shown. On the other hand previous works[8) suggest an enhancement of the performance ofr41a in real systems. Therefore it is very important to estimate system performances under practical conditions. Big differences in working pressure between R-41A and R-22 are the points of the estimation. Systems using R-41A have to be operated under high pressure conditions being advantageous as well as disadvantageous in comparison to R-22. High working pressure causes a higher density and therefore low pressure losses in heat exchangers, particularly, in evaporators, but the difference in working pressure makes it (almost) impossible to replace the one refrigerant by the other without redesigning the capillary tube. This paper describes experimental results of the pressure loss characteristics in the evaporator and the capillary tube characteristics with R -41 OA for practical systems and the system performance of an air -conditioner in a simulation based on these measurements. EXPERIMENTS Evaluation of Pressure Loss in Grooved Evaporators with R-41A Local pressure loss through the evaporator is investigated to construct a precise model of the evaporator. The experimental setup used in this measurement is shown in Fig. 1. The test section is heated by water to control the evaporating temperature. Table 2 indicates specifications for the evaporator in Fig. 2. The relation between local pressure loss (dp/dz) and quality x at the evaporating temperature 283.1 K is plotted for the mass flow fluxes GF1kg!m 2 s, 2kg/m 2 s and 4kg/m 2 s. The inlet quality Xin is fixed to.2 and the outlet Xout to 1. in each measurement. A general formulation to calculate local pressure loss for stratified two-phase flow in a smooth tube has already been proposed and it was estimated using as enhancement factor I [ 1]. The ratio of the pressure loss between a two-phase flow and a liquid I can be expressed as function of a parameter Xtt as follows: where Xtt is defined according to Lockhalt-Martinelli / =J(x") (1) Xt=Cxr:(:r (2) where p g, p I denotes the vapor and liquid density, respectively, J1 g, J1 I the vapor and liquid viscosity, respectively. 217

For the application of this approach to the flow in the grooved tube, the relation between 1 and Xtt is shown in Fig. 3. From this result, the correlation between 1 and Xtt is found to be f/j 1 = 4-.187 X 11 (3) The local pressure loss (dp/dz) TP for two-phase flow in the grooved tube can be calculated by using 1, given by the correlation equation (3), and friction factor Cfl for rough surfaces: k = 2.-log,( ) + 1.8 (4) where u1 is the liquid velocity in case of sole liquid flow in the tube, D the inner diameter of grooved tube and E the groove depth, as follows: -(t =-,'(n () Evaluation of Capillary Tube Characteristics with R -41A Although there is a theory, based on an one-dimensional adiabatic compressible flow known as Fanno flow, for calculation of a capillary tube used as an expansion device, it is inappropriate in case of capillary tubes with small diameters, because for Fanno flows thermodynamic equilibrium is assumed, but in the real small capillary rube for split type room air-conditioners[3] a delay of evaporation is often observed. This non-equilibrium phenomenon is clearly visible in the measurements shown in Fig. 4. The capillary rube length calculated by Fanno flow doesn't agree with the real length. It depends on the thermodynamic non-equilibrium region. It is very difficult to predict the behavior of two-phase flow in the tube and calculate the state of fluid along the tube from the inlet of the capillary tube to the outlet step by step. Therefore, it is important to fmd a correlation between critical mass flow rate Gr and other parameters, as condensation pressure Pcond degree of subcooling Tsc, tube length Leap tube diameter Dcap to select the capillary tube for R-41A. The experimental equipment (cf. Fig. ) was used to test configurations with inner diameters Dcap of 1.2, 1.3 and 1.4 mm and the length Leap of.8, 1.2 and 1.6m. The relation between the mass flow rate Gr through the capillary tubes and the degree of subcooling Tsc (cf. Fig. 6) reveals a proportional increase of Gr with T,, but also depends on further parameters. This exact measurement can be correlated with other parameters like Dcap, Leap Pcond via the following equation: G = 628 X D 1. 93 XL -o.<w 4 X (P jp - ) 63. X T 112 r ' (6) cap cap cond crll sc P crir stands for the critical pressure in this equation. The temperature and pressure range was chose to cover K < T sc < 1 K and 27 kpa < Pcond < 34 kpa, respectively. Experimental and data predicted using this correlation agree within the accuracy of±%. SIMULATION System Simulation of an Air-conditioner using R-41A A sketch of the experimental setup as it was used in the simulation is shown in Fig. 7. This model of the practical system consists of a rotary compressor, two conventional heat exchangers, a capillary tube, an accumulator and some connecting tubes. The compressor efficiency greatly influences the system COP, but adding the real compressor efficiency to the COP means to estimate the compressor characteristics rather than refrigerant properties. Therefore, a theoretical compressor model based on thermodynamic properties is used for this cycle simulation to evaluate exclusively the effect of refrigerant properties. Mechanical losses in the compressor are assumed to be 8%. As for other components, the above results from measurements are applied in a practical cycle. Many other workers examined the heat transfer in the grooved tube [4][6][9]. In addition, R-41A is a near-zeotropic refrigerant and it is possible to apply some the present ideas to 218

predict the characteristics of R-41A. In this study, the equation proposed by Fujii [ 4] is applied for the condenser and the equation by Yoshida [6] for the evaporator. In order to investigate the heat transfer more detailed, the two heat exchangers are divided into small sections. The solution methods follows closely the algorithms suggested in [2][]: Some initial conditions are specified and static heat balances of the refrigeration cycle are iteratively calculated until the results converge to closed graphs in the p-h diagram. In a model including the pressure loss in heat exchangers whose specification is fixed, the COP under standard test conditions (cf. Table 3) of R-4IOA is almost equal to that ofr-22. That is the reason for the pressure loss ofr-4ioa in the evaporator being about 3% smaller than that of R-22. The results of a parametric study on the influence of outdoor temperature on the COP are shown in Fig. 8. For an air temperature of 32 K at the condenser under overload conditions, for example the COP of R-41 OA turns out to be about 4% lower than the value of R-22 even though the low pressure loss. The COP of the system using R-41A is lower than R-22 because of a working pressure close to the critical pressure. Furthermore, the discharge temperature of the compressor becomes very high. Therefore a system using R-4IOA might be inadequate where high temperatures are required. On the contrary, the COP of R-41A becomes higher than the value of R-22 under underload conditions The results of a simulation for a connecting tube with an inner diameter of 8.12 mm and a system working under standard test conditions are shown in Fig. 9. The longer the connecting tube on the suction side is, the better becomes the ratio of the system COP in comparison to R-22. Therefore R-41A is appropriate to systems with long connecting tubes. Seasonal Energy Efficiency Ratio In addition to the above evaluation of the system performance, power consumption, depending on the performance of a working air-conditioning system has to be take into account. SEER (Seasonal Energy Efficiency Ratio) is a very simple evaluation method, but can be regarded as one of the more appropriate methods to evaluate the power consumption of the system. Using this approach it is possible to take it into account more, compared to standard conditions, practical operating situations. The SEER ratio between R-41A and R-22, based on a for the U. S. typical CLH (Cooling Load Hours) value and obtained with a Cd value for cyclic operations fixed to.2, turns out to be about 1.3, because of high COP ofr-4ioa under underload conditions. CONCLUSIONS In this study, new expressions for the characteristics of important components are proposed by some exact experiments for R-41A. From the comparison of the cycle performance between of R-22 and R-41A under various conditions the following conclusions can be drawn: A system using R-41A has different characteristics from one using R- 22 under practical conditions. The COP of systems using R-41A under overload conditions becomes worse than one using R-22, but it becomes better under underload conditions. The SEER of practical systems using R-41A and R-22 can be recognized as almost the same. REFERENCES [I] R. Martinelli, D. Nelson, Prediction of Pressure loss during Forced-Circulation Boiling of Water, Trans. ASME, 7, 69, 1948 [2] T. Fukushima, A. Arai, et al, Simulation of Refrigeration Cycle for Air Conditioners, Refrigeration, 2,93, 19,1977 [3] H. Koizumi, K. Yokoyama, Characteristics of Refrigerant Flow in a Capillary Tube, Trans. ASHRAE, 86, 286,198 [ 4] T. Fujii, H. Honda, Condensation of Fluorocarbon Refrigerants inside a Horizontal Tube-Proposals of Semi-empirical Expressions for Local Heat Transfer and the Interfacial Friction Factors, Refrigration,, 672, 3, 198 [] P. Domanski, Modling of Heat Pump Charged with a Non-azeotropic Refrigerant Mixture, National Bureau of Standards Technical Note 1218, 1986 [6] S. Yoshida, T. Matsunaga,et al, Heat transfer Enhancement in Horizontal Spirally Grooved Evaporator Tubes, JSME Int.J.,II,31(3),, 1988 [7] REFPROP, NIST Thermodynamic Properties of Refrigerants and Refrigerant Mixtures Database, Version 4, NIST, Gaithersburg, Maryland, 1993 219

[8] K. Furuhama, M. Komazaki, Performance Evaluation of Residential Air Conditioner with HFC32!12 Mixture, The International Symposium on R22 & R2 Alternative Refrigerants '94, Kobe,1994 [9] Y. Sato, A. Kiyotani, et al., Influence of Groove Shape on Heat Transfer Characteristics of Inner Grooved Copper Tube, Surnitomo Light Metal Technical Reports, 36, 1,199 Table 1. Comparison of the theoretical COP between R-22 and R-41A (Tc = 318.1 K, Te = 283.1 K, Tsc = K, Tsh = K) R-22 R-41A R-41AIR-22 COP..1.93 (All thermodynamic properties ofr-4ioa and R-22 by REFPROP version 4 [7]) Table 2. Specifications of the tested evaporator with grooves Outer diameter (mm) Inner diameter (mm) Wall thickness (mm) 7. 6..2 Groove depth (mm) Number of grooves Lead angle (degree).18 18 4 I e. a: "C _Q c. -;; <>.3 2 1 1 Gf-1(kg!m2s) e Gf2(kg!m2s) & Gf 4(kglm2s).2.4.6 Quality x Figure 2. Relation between the local pressure loss and the quality in the evaporator.8 1. Compressor : 8 :.. G) Pressure gauge 2. Condensor 3. Subcooler 4. Drier. Expansion valve Mass flow meter 6. Evaporator 7. Heater 8. Circulating pump 9. Power meter 1. Inverter (!) Thermo couple Figure 1. Experimental apparatus for evaporators 6----------------------. 4 -e. 3 2 2 4 6 Xtt 8 1 12 Figure 3. Relation between if>, and Xtt in the evaporator 22

,--.._ 32 '- ll).d... ::I >, ee ".. ee u 4...... 31 3 ll) Experiment ::I 29 "E Calculation... ll).. :::::. 28 ll) u <8 ci 27.2.4.6.8 Distance from capillary entrance (m) Figure 4. Comparison of the temperature distribution between the experimental result and calculation """" On c O.Dl8.16 ).14 ;... ;;: 4::: :E.12.1 Parameter (Srandard) Tc (K) Dcap (m) Leap (m).8 2 4 6 8 1 Degree of subcooling (K) Figure 6. Relation between mass flow rate through the capillary tube and degree of subcooling ([)Mass flow meter {!) Thermocouple Pressure gage 1 Compressor 2. Condenser 3. Subcoo I er 4.Drier S.Sight glass S.Capillary 7. Evaporator Figure. Experimental apparatus for capillary tubes Table 3. Standard test conditions Air temp. of indoor DB(K) 3.1 WB(K) 292.1 Air temp. of outdoor DB(K) 38.1 WB(K) 297.1 Capillary tube Connecting tube Refrigeration capacity: 2.kW Figure 7. Schematic view of the system 221

2 1.1 tl1. u -< c 1..9 8.9 -.8 8. 8...,...,...,...r-""T""T""'""''...,...T""!""..,...,...,..., 3 31 32 33 Outdoor temperature (K) Figure 8. Influence of the outdoor temperature on the COP 4.8... _...... a!j 4.6- --'l!!w...,) u -e- R41A 4.4-4.2- --8 R22 4 I I 1 1 2 Connecting tube length Figure 9. Influence of the length of the connecting tube on the COP 222