Aqua-Gen 3 INSTRUCTIONS

Similar documents
Supreme Heating User Guide. Heatseeker Solar Pool Heating

Brivis Touch Controller. Installer Manual

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

7-Day. Digital Thermostat. residential. & 2-cool

Above Ground Pool Solar Heating System

OPERATING INSTRUCTIONS

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

Installation & Operating Instructions

SPA-QUIP LTD 3 BUTTON ELECTRONIC STANDARD SPA POOL CONTROLLER DEALER STAMP: DATE INSTALLED SERIAL NUMBER SOLD BY INSTALLED BY STARTUP TESTING

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

INSTALLATION INSTRUCTIONS

INSTALLATION & USER MANUAL

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Heatseeker Plus Solar Pool Heating

HEAT PUMP PROGRAMMABLE THERMOSTAT

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

POWER SHOWERS Models 4500M 5002M 4500T 5002T

SunRotor Solar Pump Installation Guide

MC-100V & BC-100V Operation / Installation Manual

Operation and Maintenance Manual 120V/60HZ

5+2 Day. up to HEAT COOL

Installation & Service Manual

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

SALT WATER CHLORINE GENERATOR. Model: SMC20TA & SMC30TA SMC INSTRUCTION MANUAL

Compact Movement Activated Sensor Installation Instructions

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

Smart Temp. Model

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

INSTALLING AND USING THE KELCO F50 PUMP CONTROLLER

Retrofit an evacuated tube collector to an existing cylinder Updated

Simple to Set Timer (SST) Frequently Asked Questions

1 For All Programmable Digital Thermostat

QUICK START GUIDE. Modular 3000 Series. 115 V / 60 Hz

Spectrolink Comfort Control. Home Owner's Manual Heating

SC Installation, Operation & Application Guide

T105 Advanced Remote Control Programmable Thermostat. User Manual

INSTALLER S & OWNER S MANUAL

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

INSTALLER S & OWNER S MANUAL

Installation & Operating Instructions

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

PRIMUS IMPORTANT. User Manual and Product Specifications. Portable Fridge/Freezer. Part No. PRI18LP - 18 Litre. Read instructions before operation.

15,000 BTU Portable Air Conditioner

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

SC Installation, Operation & Application Guide

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

THE BLACK BOX MONITORING AND CONTROL OF SOLAR WATER HEATERS

Q Model AuCS A Accessory

User Manual. For use with model CS-10A/CS-11A solar ventilation system controllers

Next Generation Corona Discharge Installation & Operation Manual

T-32-TS Touchscreen Thermostat. Installation Manual

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

SS1095 Ice Maker.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

GeyserWise MAX. Instruction manual. All in one hot water management

Portable Refrigerator

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

AMANA PHWT-A200 THERMOSTAT

INSTALLATION & USER MANUAL NATIONAL. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual 1

ASSEMBLY & OPERATION MANUAL

LUCCI AIRFUSION FRASER DC CEILING FAN

SC Installation, Operation & Application Guide

PoolSweepa Wallclima / Optima Pool Cleaners. Operating Instructions

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

SOLARMATIC TM. Solar Pool Heating Controller OWNERS MANUAL. Manufactured in Australia By

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Spa Control System OWNER S MANUAL

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

100 Series Maxi Internal Filters

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Using the. Ducted Gas Central Heating Dual Cycle Refrigerated Air Conditioning Ducted Evaporative Air Conditioning. with your.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

2 - Wire Programmable Digital Thermostat

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

OWNER S MANUAL IMPORTANT - INSTALLER MUST COMPLETE FOR WARRANTY PURPOSES. Made in Western Australia by:

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

Operator: Save these instructions for future use!

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

Local Air Conditioner

Undercounter Refrigeration

Transcription:

Aqua-Gen 3 INSTRUCTIONS DESCRIPTION: The Aqua-Gen 3 is a premium automatic solar controller with temperature adjustment, manual, winter and tropical mode features. All configurable items are retained after a power outage for up to 14 days. CONTROLLER INSTALLATION: Find a suitable location to mount the control box. The controller must be installed out of direct weather and no closer than 3m from the waters edge. Lift up the two mounting tabs and use two appropriate screws to mount the control box to the wall, keeping in mind that the power cable is 1.8m long and should be plugged directly into a general power outlet, not into an extension lead. The solar pump plugs into the 240Vac socket marked as PUMP. The pool sensor must be fitted into the suction line of the pump, as close to the pool as practical, preferably in a position out of direct sunlight. It is recommended that a 14.5mm hole be drilled in the PVC pipe, this can be carried out using a Dontek PD01 grinding drill or a small pilot hole can be drilled and a 14.0mm drill-bit used spinning in a counter clockwise direction to minimise the chance of shattering pipe. Insert the grommet into the pipe and gently push in the black sensor barb. The green sensor plug is to be fitted to the plug socket marked POOL. DO NOT cable-tie or tape sensor wires to mains power, in some cases there is some benefit to cable tie 30cm of wire from the sensor to the pipe and insulate this section (some ambient differences can travel up the tinned copper wire and affect the sensor reading). Roof sensors must be fitted into a small piece of solar collector or equivalent and attached to the roof. The best location is within arms length of the gutters edge of the house or shed as long as the sensor end is not shaded and is on a roof of similar aspect of the main collector. It must not be fitted on top of the solar collector or fitted to high points on the roof like ridge capping as false readings will be detected. Keep in mind that it is of the utmost importance to keep the roof sensor as short as possible as this will assist in the longevity of the sensor and controller in the event of electrical storm activity and power surges. Sensor cables must not be run parallel to power cables and run lengths should be less than 50m if possible. Cable ties should be used to fasten the sensor cable to the cold water inlet pipe making sure that the ties are approximately 10mm from PVC fittings. Cable ties should be tightened only firm, over tightening can cause breaks in the outer PVC if not careful. If the cable is to be run under ground a conduit must be used to protect the wire and there is to be no cable joins within, conduit ends must be sealed to prevent water ingress. Any excess cable should be removed and re-fitted ensuring that the wire ends are tinned with solder. The sensor plug is to be fitted to the right hand socket marked ROOF.

CONTROLLER OPERATION & SETTINGS TEMPERATURE LIMIT: To adjust the pool limit simply press the UP button to increase or the DOWN button to decrease the desired temperature. The controller will automatically choose to run the pump based on solar gain (i.e. sun shining & roof is hot). Once the desired temperature is achieved the pump is stopped and a 4 hour wait commences to ensure no energy is wasted by cycling the pump. If after 4 hours the roof is hot enough then the pump may start to provide another heating cycle and if the desired temperature is reached again then no heating will occur until the next day unless the controller is operating in time-clock mode where heating can occur until solar lockout time (09:00 until 19:00). MODE of operation: Pressing the SELECT button once will display the current mode of operation, pressing it again or holding it will select the next available mode of operation. The available modes are SUMMER, MANUAL, TROPICAL or WINTER. Summer mode is the normal operating mode for heating the pool. Winter mode of operation is for off-season maintenance or if pool heating is not required (AWAY MODE). This is a better option than turning off the controller as it will flush treated pool water through the solar system as well as prolong pump bearing and mechanical seal life. The pump will run for 3 minutes each day from when the winter mode was selected or at 10am if the time-clock mode was selected. Tropical mode is for situations where the pool water overheats due to direct heating from the sun, beyond the set limit. When the roof is 4 C cooler than the pool temperature, the pump is started (this will most likely occur at night) and will attempt to cool the pool to 1 C above the temperature limit. Normal heating will occur the next day if the pool drops below the temperature limit by 1 C. Manual mode is for testing the pump installation on a cold or cloudy day. Once manual mode is selected the pump will start if it has been off, or stop if it has been on (running). After 30 minutes manual mode will time-out and return to Summer Mode with a default temperature limit of 30 C Settings mode is for setting the unit into time-clock operation. When you select this option you will be asked if you wish to use the clock feature (CLK? ON/OFF). If you select OFF then the controller will not work as a time-clock model and will allow the solar pump to run whenever there is solar heating available. If you select ON you will be prompted to set the time of day, the controller will work in time-clock mode and the solar pump is prevented from starting outside of the set hours (unless tropical mode is selected).

Set the time of day in 24 hour format, note there is an AM/PM indication to avoid incorrect settings. Seconds are automatically set to zero. Once the time is set select the START hour from 6am until 12noon, default is 9am which means the solar pump cannot start before 9am. Now select the END hour from 15:00 (3pm) until 21:00 (9pm), default is 19:00 (7pm) which means the solar pump will stop at 7pm. INSTALLER SETTINGS - Adjustable differential and anti-freeze feature: Special note: Adjusting these values to any setting other than the defaults may adversely affect the performance of this controller. To select these features, hold the DOWN button then press SELECT. When you select this option you will be prompted to set the solar gain start temperature (RUN x) this setting allows the pump to start if the roof temperature exceeds the pipe temperature by this value, adjust with the UP/DOWN button, press SELECT to accept. Next you will be prompted to set the differential hysteresis (END x) which turns the pump off when roof temperature is less than the pipe temperature plus this value, adjust with the UP/DOWN button, press SELECT to accept. Default values are 8 for RUN and 4 for END, these are the optimal values for maximum efficiency, some coastal locations may benefit from a reduced run value of 6 C for RUN and 4 C for END. Next is anti-freeze, you will be prompted by FRZ? ON/OFF, adjust with the UP/DOWN button, press SELECT to accept. If you select OFF then all the above settings will be saved and the unit will restart. If you selected ON then you will be prompted to adjust the anti-freeze start temperature point as follows; FREEZ x adjust with the UP/DOWN button, press SELECT to accept. Once the roof temperature gets to the anti-freeze setting or below then the pump will be turned on for 3 minutes then turn off for 30 minutes, this sequence will repeat until the roof temperature rises above the anti-freeze temperature. FACTORY TEST: To run the factory test, hold the SELECT button when first applying power, the unit will perform a series of self-diagnostic functions with the pump running. If there are any faults they will be reported on the display before the unit restarts into normal operation. Note: that this will force all settings to a factory default state, if anti-freeze had been selected then turn it back on as described under adjustable differential and anti-freeze feature. Also re-enable time-clock if desired. NOTES: 1. If a sensor fault is detected the controller will display which sensor failed (POOL and/or ROOF) and the type of failure. 2. Should power be interrupted for any reason, the controller will resume normal operation when power is restored, all information will have been kept for up to 14 days.

3. Temperature sensor used with this unit is digital and is accurate to 0.5 C, no calibration is required. 4. The sensor cable with the thin trace is the positive and is usually fitted to the right hand side of the green plug when looking at the plug screws, incorrect polarity will be displayed as a short circuit or reversed fault. 5. If the controller has stopped pumping and is displaying a higher temperature than expected it may be caused by a pump which is failing to prime, check the pump and if necessary prime the pump as per the pump manufacturers instructions then reset the controller by turning it off/on. 6. Maximum rated output load for the 240V socket is 10 Amps 2400 Watt.

WARRANTY - Aqua-Gen 3 This range of product is covered by a limited 3 year warranty against component failure or faulty workmanship from the date of installation. A faulty unit should be returned in the first instance to the dealer from which the unit was purchased. Damage to the unit due to misuse, power surges, lightning strikes or installation that is not in accordance with the manufacturer s instruction may void the warranty. Warranty does not cover travel costs to or from installation site. Return to supplier for repair Customer Record (to be retained by the customer) Dealer/Installer Name: Model Number: Serial Number: Date Installed: Aqua-Gen 3 For service assistance phone 1300 130 693 Dontek Electronics Pty Ltd PO Box 239 Bayswater, Victoria 3153 www.dontekelectronics.com.au Return to Manufacturer for repair