DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

Similar documents
DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

GREEN REFRIGERANT R-410A

WALL-MOUNT HEAT PUMPS - (60HZ)

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

Q-TEC QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Q-TEC Q24A-Q60A Air Conditioners

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

THE WALL-MOUNT 6-TON AIR CONDITIONERS

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

GREEN REFRIGERANT R-410A

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

GREEN REFRIGERANT R-410A

TECHNICAL SPECIFICATIONS

GREEN REFRIGERANT R-410A

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

RGE 13 A T - 1 A

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA

General Description. Safety Listed

13 GEP A L P - 1 A

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

Product Guide. Wallmount. Air Conditioners & Heat Pumps

General Description. Safety Listed

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

INSTALLATION AND SERVICE INSTRUCTIONS REPLACEMENT PARTS MANUAL

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

48PGD/E/F/L/M/N PG20-28

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

TECHNICAL SPECIFICATIONS

Q/Tec TM QA-Series Air Conditioners

INSTALLATION INSTRUCTIONS

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

INSTALLATION AND SERVICE INSTRUCTIONS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Hazardous Location Certified

62DA,DB,DC,DD,DE,DF07-38

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

MACH N-407 Heat Pump Air-Cooled Chiller

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

MERIT Series R-410A - Upflow / Horizontal

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

MERIT Series R-410A - Upflow / Horizontal

MAC N-407 Air-Cooled Chiller

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Q/Tec TM QW-Series Water-to-Air Heat Pumps

Product Data INDUSTRY LEADING FEATURES / BENEFITS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

General Description. Operation

REPLACEMENT PARTS MANUAL

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

PACKAGE AIR CONDITIONER

Product Data. Fig. 1 - Unit 50VR -A

10EER 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor)

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Concealed Ducted Split Series R-407C MBH

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Commercial High-Efficiency Condensing Units

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Transcription:

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D35A/L 1-tage Right & Left-Hand Control Panel The Bard DUAL-TEC Wall Mount Air Conditioners with -48VDC Blower Motor and DC Voltage Free Cooling Economizer are designed for maximum indoor cooling at the most efficient operating cost for year-round operation in the demanding equipment shelter environment. D25 & D35 Models are sized to replace existing 3-Ton wall mount air conditioners. The DUAL-TEC units operate on both AC and -48VDC positive ground power under normal power supply conditions. If there is loss of AC power supply (shore &/or back-up generator) the DUAL-TEC will continue to operate as free-cooling or ventilation system using the shelter s DC power. The DUAL-TEC indoor blower and economizer operate from -48VDC and no inverter is required. The DUAL-TEC units will supply up to 100% of rated cooling airflow in free cooling mode with the ability to exhaust the same amount through the unit itself without any additional relief openings in the shelter. Green Refrigerant R-410A DUAL-TEC pecial Features Brushless -48VDC Indoor Blower Motor: Features low sound levels and soft-start capabilities. oft start function helps to ensure DC power levels will not decrease on start up, and brushless design ensures low DC power noise. The motor is self-adjusting to provide the proper airflow rate without user adjustment or wiring changes. DC Polarity Monitor: Includes diagnostics and protects critical DC components against reverse polarity and out-of-range DC power. Range is 40-60 VDC. Remote Monitoring: Bard-Link web interface with use of LC Controller. 100% Free Cooling Unit Ventilator: All units are equipped with a full-flow free cooling ventilator. The ventilator uses DC power for operation in conjunction with the -48VDC Indoor Blower during AC power loss. Modulating air intake allows precision temperature control inside the structure while maximizing energy savings. PLC Logic Board: All units are equipped with a PLC Logic Board for advanced unit operation and alarm capability. The PLC Logic Board allows for orphan mode unit operation if communication with the LC controller is lost. Bard DUAL-TEC tandard Engineered Features All Models Copper Tube / Aluminum Fin Coils: Grooved copper tubing and enhanced aluminum fins provide maximum heat transfer and high energy efficiency. Optional phenolic-coated coils are also available. Air Conditioner Compressor: croll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life. R-410A Refrigerant: Designed with R-410A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2010 EPA requirements. PTCR Motor tarting Device: tandard on 1-phase models, increases compressor motor starting torque 2-3 times. Optional factory or field installed hard start kit available, replaces PTCR device. Galvanized 20 Gauge Zinc Coated teel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1000 hours of salt spray tests per ATM B117-03. Condenser section and entire cabinet coatings are also available. Foil Faced Insulation: tandard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Liquid Line Filter Drier: tandard on all units. Protects system against moisture. 24V Transformer: 75VA with circuit breaker. Electric Heat trips: Features an automatic limit and thermal cut-off safety control. Heater packages are factory installed options for all models. Two-Inch, MERV 8 Air Filters: Are standard equipment. All models include tight-sealing U-channel filter bracket to minimize air bypass around the filter. Built-In Circuit Breakers: HACR-type circuit breakers are standard for AC power supply, and DC rated circuit breaker used for -48VDC power circuit. High & Low Pressure witches are Auto-Reset: tandard on all units. Built-in lock-out circuit resets from the shelter Bard- Link Controller. Provides commercial quality protection to the compressor. Refrigerant ight Glass: tandard on all units. Low Ambient Control: Modulating LAC standard on all models. crew-on fitting design for ease of service. Used with LC eries Controller Complies with efficiency requirements of AHRAE/IENA 90.1-2013. Certified to ANI/ARI tandard 390-2003 for PVU (ingle Package Vertical Units). Intertek ETL Listed to tandard for afety Heating and Cooling Equipment ANI/UL 1995/CA 22.2 No. 236-05, Fourth Edition. Commercial Product - Not intended for Residential application. Bard is an IO 9001:2008 Certified Manufacturer Page 1 of 12

Capacity and Efficiency Ratings 1-tage Compressors MODEL D35A D35L Cooling Capacity BTUH 36,000 EER 10.00 Capacity is certified in accordance with ANI/ARI tandard 390-2003. Rating conditions are 95 F (35 C) outdoor and 80 F DB/67 F WB (26.5 C / 19.5 C WB) return air. EER = Energy Efficiency Ratio (BTU / Watt Efficiency) is certified in accordance with ANI/ARI tandard 390-2003. Includes DC watts for blower motor. Ratings are with no outside air. Performance will be affected by altitude. Electrical Ratings 1-tage Compressor Models MODEL D35A2PA D35L2PA D35A2PB D35L2PB Electrical Rating 60 Hz 230/208-1 230/208-3 Operating Voltage Range 197-253 DC Electrical Rating -48VDC Operating Voltage Range 40-60 VDC Compressor Voltage 230/208-1 230/208-3 Rated Load Amps 15.9 / 17.6 11.8 / 13.0 Branch Circuit election Current 18.0 13.3 Lock Rotor Amps 112 / 112 88 / 88 Fan Motor Fan Motor HP 1/3 Volts 230/208-60-1 Full Load Amps 2.5 Fan CFM 2200 DC Blower Motor Blower Motor HP 3/4 Volts -48VDC Blower Motor Full Load Amps 14.0 hipping Weight (Lbs.) 375 Neg. 48VDC positive ground. Unit Charge Rates (R-410A) UNIT td. Unit - Lbs. D35A2P/D35L2P - DUAL-TEC -48VDC Right & Left Hand Free Cooling 4.50 DC Free Cooling Unit Ventilator Page 2 of 12 DC Powered Free Cooling Ventilator: The DUAL-TEC free cooling ventilator allows for cooling operation when outdoor temperature conditions are acceptable outside the building structure. By using a modulating motor controlled by the PLC Logic Board, the ventilator allows for filtered outdoor air to enter the structure and warm air to exit the structure to provide cooling with minimal energy usage. The ventilator has the following features: Defaults to temperature only, with optional humidity sensing. Exhaust air passage maintain a slight positive indoor air pressure. Easily serviceable, modulating DC powered vent motor. Large air intake and exhaust passages for increased efficiency. Advanced blade sealing for minimal air infiltration when closed. Intake air filter. Advanced PLC algorithmic operation. Outdoor air temperature and enthalpy sensor. Return air temperature sensor.

UMMARY ELECTRICAL RATING 1-tage Compressor Models MODEL Rated Volts, Hertz & Phase Minimum Circuit Ampacity AC Power Circuit Maximum External Fuse or Ckt. Brkr. Field Power Wire ize DC Positive Ground Power Circuit Minimum Circuit Ampacity Maximum External Fuse or Ckt. Breaker Field Power Wire ize D35A2PA0Z / D35L2PA0Z 208/230-60-1 24 40 8 15.6 20 12 D35A2PA05 / D35L2PA05 208/230-60-1 26 40 8 15.6 20 12 D35A2PB0Z / D35L2PB0Z 208/230-60-3 19 25 10 15.6 20 12 D35A2PB06 / D35L2PB06 208/230-60-3 19 25 10 15.6 20 12 These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses & conductor wires in accordance with the National Electrical Code & all local codes. Cooling Application Data - Outdoor Temperature Model D35A/L Return Air (DB/WB) j 75/62 80/67 85/72 Cooling Capacity 75 F 80 F 85 F 90 F 95 F 100 F 105 F 110 F 115 F 120 F 125 F Total Cooling ensible Cooling Total Cooling ensible Cooling Total Cooling ensible Cooling j Return air temperature (air entering unit). 38,700 28,800 41,300 27,900 49,200 28,600 36,700 28,200 40,000 27,600 46,800 28,000 35,000 27,600 38,800 27,300 44,600 27,500 33,200 26,900 37,500 26,900 42,400 26,700 31,500 26,300 36,000 26,500 40,200 26,000 30,100 25,600 35,000 26,000 38,300 25,200 28,600 24,900 33,700 25,500 27,300 24,200 32,500 25,000 26,000 23,500 31,300 24,400 24,800 22,800 30,000 23,800 23,700 22,000 28,800 23,100 36,400 24,300 34,600 23,500 32,900 22,500 31,200 21,500 29,600 20,500 Capacity Multiplier Factors % of Rated Airflow -10 Rated +10 Total BTUH ensible BTUH 0.975 0.950 1.0 1.0 1.02 1.05 Outdoor ound Ratings Cooling Mode DITANCE FROM HVAC UNIT dba 3 Feet 72.1 5 Feet 69.4 10 Feet 67.1 1. Values recorded in Bard Manufacturing Company, Inc. ound Lab Facility. 2. Actual field results may vary with local conditions that can affect ambient background levels. Page 3 of 12

Indoor Blower Performance MODEL Rated EP MAX EP Free Cooling CFM above 40 Free Cooling CFM below 40 Rated Full Load Cooling CFM Electric Heat Airflow D35A/D35L 0.15 0.50 1800 800 1100 1800 Free Cooling Logic Control derives at this decision point, and switches the indoor motor speed. The damper actuator will then adjust to still yield a 55 F supply air temperature. Factory Built-In Electric Heat Tables Model Voltage Phase KW Amps BTUH 240 208 240 208 240 208 -A05 240/208 1 5.00 3.75 20.8 18.0 17,065 12,799 -B06 240/208 3 6.00 4.50 14.4 12.5 20,478 15,359 LC2000 Dimensions and Weight 1 1/2" K.O. TYP. 3/4" K.O. TYP. The LC2000-300 Controller must be used with the DUAL-TEC eries Wall Mount LC Controller Weight: 25 lbs. 16 1/8" 6 1/16" 12" MI-3650 Part Number Description Included with LC2000 8301-055 EMI Ferrite Filter (1 needed for each unit connection to Controller) 2 8301-059 TEC-EYE (ervice Tool), 5 ft. communication cable 1 8403-079 Remote Temperature and Humidity ensor with 35' wire 1 8301-058 Remote Temperature ensor (2 additional sensors may be used) with 35' wire Optional Addtional Temperature ensors may be added, but not additional Temperature/Humidity ensors. Page 4 of 12

DUAL-TEC Unit Connectivity with LC2000 Controller DUAL-TEC Connectivity Features: The DUAL-TEC free cooling unit is made to work in conjunction with the LC2000 eries Controller. Up to two (2) DUAL-TEC units can be connected to the LC2000 controller using 2-wire twisted pair with drain. Each unit and the LC2000 controller contains an advanced PLC logic board for communication. The DUAL-TEC unit and LC2000 Controller have the following connectivity features: When used with the LC2000 controller, humidity levels inside the shelter can be monitored and outdoor air intake through the free unit cooling ventilator is closed when humidity levels are unacceptable. The DUAL TEC unit supply sensor allows temperature monitoring of conditioned and outdoor air entering the structure. By using the supply air temperature measured, the unit is able to supply cooling within the structure without extreme temperature variations. The DUAL TEC unit outdoor temperature sensor allows free cooling operation when outdoor ambient temperatures permit operation. DUAL-TEC Unit #1 DUAL-TEC Unit #2 (Not required for operation) LC Controller Primary Indoor Temperature and Humidity ensor Climate Controlled Zone Hydrogen Detector, Normally Closed Contacts Optional Indoor Temp. ensor #1 Optional Indoor Temp. ensor #2 This illustration demonstrates connection of DUAL-TEC units and the LC2000 controller with optional sensors and equipment. Fire/moke Detector, Normally Closed Contacts Remote Access Computer Page 5 of 12

DUAL-TEC Unit in Orphan Mode DUAL-TEC Orphan Mode Features: The DUAL-TEC free cooling unit is made to function in orphan mode if connection to the LC controller is lost due to a severed connection wire or other system failure. When in orphan mode, the DUAL-TEC unit will continue to provide cooling to the structure until the connection can be restored. By using a return air temperature sensor measuring structure air temperature and a supply air temperature sensor to measure air provided to the structure, the unit is able to provide cooling. Orphan mode temperature set points are contained inside the DUAL-TEC PLC logic board. When connection of the DUAL-TEC unit is restored, the unit temperature set points will revert back to the temperature set points programmed into the LC controller. DUAL-TEC Unit running in Orphan Mode upply Temp. ensor Leaving air Return Temp. ensor Entering air UNIT OFFLINE alarm message LC Controller Indoor ensor not used until connection restored. ignal Lost! Climate Controlled Zone This illustration demonstrates Orphan Mode unit operation. If connection to the LC controller is lost for any reason, the unit will continue to operate using the return air sensor and supply air temperature sensors in the unit. Page 6 of 12

DUAL-TEC Unit in -48VDC Free Cooling Mode DUAL-TEC -48VDC only Features: The DUAL-TEC free cooling unit is made to function in -48VDC Free Cooling Mode if conditions outside the shelter are acceptable for cooling. The DUAL-TEC unit will attempt to maintain the set points programmed into the LC controller by bringing outside air into the shelter through the unit ventilator. By running the indoor blower and maintaining a consistent supply temperature by modulating the vent damper blade using -48VDC power supplied, the unit is able to provide cooling. Compressor operation is used to cool the shelter in conjunction with the -48VDC indoor blower and vent if outdoor air intake is inadequate to provide structure cooling. If outdoor ambient conditions reach a point that is unacceptable for cooling the structure, the vent damper blade closes, and the unit runs in compressor only cooling mode. DUAL-TEC Unit running in -48 Free Cooling Mode Blower Operation Available Vent Operation Available Leaving air Outdoor Air Intake LC Controller LC Controller Communicates with the DUAL TEC unit. Climate Controlled Zone Compressor Cooling Operation Not Used unless LC controller set points are not achievable or outside conditions are unacceptable for vent operation. Indoor Temperature ensors used. Hydrogen Alarm Operational Fire/moke Alarm Operational This illustration demonstrates -48VDC unit operation. The DUAL-TEC unit is able to bring outdoor air into the structure using the indoor blower and the free cooling ventilator. The LC controller is operational during -48VDC operation along with alarm functionality. Ethernet Connection Operational Page 7 of 12

TEC-EYE DIAGNOTIC TOOL FOR UE WITH DUAL-TEC UNIT TEC-EYE Features: The DUAL-TEC free cooling unit contains a PLC logic board located inside the unit control panel. The TEC-EYE tool, included with the LC2000 controller, allows for diagnostics and unit set point settings to be completed at the unit. This allows the user to complete various tasks outside where the units are located, and access to the inside controller is not needed for many tasks. Using an RJ11 modular phone connection and the cord provided with the TEC-EYE, the service technician or contractor can run testing procedures or verify unit installation. Magnets on the back of the TEC-EYE allow for temporary mounting to the side of the DUAL-TEC unit while these tasks are being completed. TEC-EYE TM Connection to DUAL-TEC Unit PLC Logic Board Modular Phone Connector for TEC-EYE TM Hand-Held Diagnostic Tool TEC-EYE Diagnostic Tool Part #8301-059 TEC-EYE Display ALARM KEY UP KEY MENU KEY ENTER KEY ECAPE KEY DOWN KEY ALARM KEY Allows viewing of active alarms ilences audible alarms Resets active alarms MENU KEY Allows entry to Main Menu ECAPE KEY Returns to previous menu level Cancels a changed entry UP KEY teps to next screen in the display menu Changes (increases) the value of a modifiable field ENTER KEY Accepts current value of a modifiable field Advances cursor DOWN KEY teps back to previous screen in the display menu Changes (decreases) the value of a modifiable field DUAL-TEC UNIT ALARM Alarm Features: The DUAL-TEC free cooling unit is capable of sending and storing various unit alarms and contains the following alarm features: Low Refrigerant Pressure Alarm High Refrigerant Pressure Alarm Landline/hore/Prime Power Outage Dirty Air Filter Alarm DC Free Cooling Damper Fails to Open Alarm DC Free Cooling Damper Fails to Close Alarm Communication Failed Alarm upply Air Temperature ensor Failed Alarm Outdoor Temperature ensor Failed Alarm Outdoor Humidity ensor Failed Alarm Return Air Temperature ensor Failed Alarm NOTE: ee D-eries and LC2000 Installation Manual for Network, LC Controller and helter Alarms. Page 8 of 12

Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE D35A 15" 20" NOTE: For side-by-side installation of two (2) D**A models, there must be 20" between units. This can be reduced to 15" by using a D**L model (left side compressor and controls) for the left unit and D**A (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET D35A 1/4" 0" Refer to the Installation Manual for more detailed information. Dimensions of D25A & D35A Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T D35A 38.200 17.125 74.563 7.88 27.88 13.88 27.88 40.00 17.20 29.75 17.93 30.75 32.75 33.25 31.00 2.75 39.13 26.75 9.14 4.19 12.00 9.00 W Built In Rain Hood 4 Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) ECON Hood D 1.250 2.13 A I ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location E O.44 upply Air Opening B R F Ventilation Air C H Optional Electrical Entrances Return Air Opening G Cond. Air Outlet 7.000 Low Voltage Electrical Entrance High Voltage Electrical Entrance Cond. Air Inlet J K L M P T Front View ide View Drain N Q Back View Bottom Installation Bracket MI-3849 Page 9 of 12

Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE D35L 15" 20" NOTE: For side-by-side installation of two (2) D**L models, there must be 20" between units. This can be reduced to 15" by using a D**L model (left side compressor and controls) for the left unit and D**A (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET D35L 1/4" 0" Refer to the Installation Manual for more detailed information. Dimensions of D25L & D35L Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T D35L 38.200 17.125 74.563 7.88 27.88 13.88 27.88 40.00 17.20 29.75 17.93 30.75 32.75 33.25 31.00 2.75 39.13 26.75 9.14 4.19 12.00 9.00 R E Heater O 4 Pitch Access.44 Panel D W upply Air Opening B ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location Built In Rain Hood 2.13 A I 1.250 Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Econ. Hood Return Air Opening Optional Electrical Entrances C Ventilation Air F T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet ide View 7.000 Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View G MI-3848 Page 10 of 12

This page intentionally left blank. Page 11 of 12

Air Conditioning Wall-Mount Model Nomenclature 1-tage Compressor Models MODEL ERIE CAPACITY 35-3 Ton D 35 A 2 P A 05 4 P X X X J A - Right Hand L - Left Hand PLC CONTROLLER REVIION VOLT & PHAE A - 230/208-60-1 B - 230/208-60-3 KW 0Z - 0KW 05-5KW (1 Phase) 06-6KW (3 Phase) COLOR OPTION X - Beige 1 - White 4 - Buckeye Gray PECIAL FEATURE CONTROL MODULE J = HP, LP, CCM, LAC, Alarm Contacts, tart Assist (1-Phase only) C = "J" Module plus Comp. CCH DUAL-TEC tandard Controls -48VDC Free Cooling Unit FILTER OPTION P - 2" Pleated (MERV 8) M - 2" Pleated (MERV 11) - 2" Permanent Cleanable Filter COIL OPTION X - tandard 3 - Phenolic Coated Evaporator and Condenser for coastal or other severe duty environments. 4 - Condenser ection Component Coating, Coated Evaporator Coil and Condenser Coil 5 - Internal and External Cabinet Component Coating, Coated Evaporator Coil and Condenser Coil High Pressure witch: Required afety Device that also provides protection to the compressor system when system refrigerant pressure is above an acceptable level. Auto Reset, 650 psig. Output to compressor control module. Low Pressure witch: Provides protection to the compressor when refrigerant pressure falls below an acceptable level. Auto Reset, cut out at 40 psig. Output to compressor control module. Low Ambient Control: Modulating control that removes power from the condenser fan to allow for unit compressor cooling operation at outdoor ambient temperatures below 65 F. Factory set for system performance. crew-on connection for easy servicing. Output to condenser fan motor. Compressor Control Module: Compressor protection device that has a 30-second to 5-minute timer. This module features a delay-on-make for initial startup for a minimum of 2 minutes plus 10% of the timer setting. There is no delay during routine operation. Allows one automatic retry after high pressure switch activation, then goes into hard lockout mode. Output to PLC logic board. tart Assist (ingle Phase Models Only): PTCR motor starting device increases compressor motor torque 2-3 times. upply Air ensor: 10K Thermistor measures supply air temperature, output to PLC logic board. Return Air ensor: 10K Thermistor measures return air temperature, output to PLC logic board. Evaporator Coil ensor: 10K Thermistor prevents coil freezing due to low return air temperature. Output to PLC logic board. Outdoor Temperature & Enthalpy ensor: 10K Temperature sensor and 4-20mA humidity transmitter, output to PLC logic board (PLC defaults to temperature only). Phase Monitor (3-Phase Models Only): Prevents 3-phase compressor operation to protect the compressor if the device senses incorrect phasing. LED indicator light. Filter witch: Adjustable switch to indicate the unit air filter needs to be replaced. Output to PLC logic board. DUAL-TEC Optional Controls Compressor Crankcase Heater: 2-wire heater that prevents refrigerant migration and mixing with crankcase oil when the unit is off, prevents condensation of refrigerant in the crankcase of the compressor, and keeps refrigerant at a temperature higher than the coldest part of the system. Recommended for Canada and cold climate compressor operation. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. 3536 December 2017 upersedes: 3536-716 Page 12 of 12