An ISO 9001 : 2008 Certified Company SUBURBAN INDUSTRIAL WORKS (LESSEE)

Similar documents
we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

Selecting the Correct Fan

Centrifugal Fans, Non-Overloading, Backward Inclined

Double Skin Air Handling Units

A. Codes and Standards that are Standard at the University:

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Fans: Features and Analysis

Double Skin Air Handling Units

MXI Mixed Flow Inline Fan

Glossary of Terms Laboratory & Fume Exhaust Fans

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Industrial Fans & Blowers

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

R. K. Engg. Works Private Limited

Introduction to Fans. The Basics of Fan Principles and Terminology

Centrifugal Blower. Backward/Aerofoil Curved.

Ducted Propeller. Airflow Volume

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

MACHINERY BLOCKING RECOMMENDATIONS

EHH SERIES DRAW THROUGH FAN COILS CFM

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

CML Northem Blower Inc. Air Movement Equipment

Double Skin Casing Air Handling Units

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

Centeral Station Air Handling Unit

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Wilo IL Vertical Split-Coupled Inline Pumps

Horizontal Split Case Pumps Type U

SECTION AIR HANDLING UNIT

Fuji Electronic VFC 084P-5T

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

an ISO 9001 Company Bulletin PR-112

JM Aerofoil Fans Bulletin JMA60-05

Tunnel Axial Flow Fan

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Hindustan Blowers.

Practical Consideration of Noise from Fans

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

SECTION (15833) - HVAC POWER VENTILATORS

Miniveyor. Tough Fans for Tough Jobs! NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

Bulletin FH05 FUME EXHAUST

Selecting Fans and Determining Airflow for Grain Drying and Storage

Great for Rental Stackable: Constructed with interlocking ribs for stacking vertically. Great for storage as they need a minimal footprint

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

DAE Systems. Fan Selection Guide. Section 1: Terminology

GIVE A FAN A CHANCE Installation Dos & Don ts

University of Houston Master Construction Specifications Insert Project Name

dualarm Vertical In-Line Pumps

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Axial flow fan AXICO ANTI-STALL

ARI 260 Standard: Sound Rating of Ducted Air Moving and Conditioning Equipment

Technotech Enterprises

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

EG Series Screw Air Compressors Life source of industries kw

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

The Advantages of Choosing Centrifugal Fans

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

SECTION (15820) - AIR DUCT ACCESSORIES

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

AIR HANDLING UNITS. Revision AG 16-07

A. This Section includes air-handling units with coils for indoor installations.

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

ROTARY DRYER CONSTRUCTION

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

Utility and Centrifugal

Caution: The fans must not be used in bath or shower enclosures.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN!

Copy Right By: Thomas T.S. Wan

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

B. System Design and Performance Requirements


N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

MARLOW PUMPS RECIRCULATION

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

Transcription:

An ISO 9001 : 2008 Certified Company SUBURBAN INDUSTRIAL WORKS (LESSEE)

Welcome Suburban Industrial Works (SIW) was incepted in the year 1954 for manufacture of Centrifugal and Axial Flow Fans with world renowned established design of Buffalo Forge and SIROCCO. Since 1957 SIW started marketing of products and increase their market share and customer base through widening its product range and capacity in terms of man power and product domain. Since May 1981 Suburban Industrial Works (LESSEE) came in to being with the up gradation of complete infrastructural setup with design, man power, plant and machinery. Personnel with experience of decades in respective field along with technically and qualified support staffs soon changed the complexion of the organization. Mingled with the product quality and a strong marketing network within a short span of time the company emerged as a force to reckon with HVAC, Processing and other core sector industries. Quality Management SIWL has adopted very strict quality measures to ensure the uniform acceptable quality keeping in view the requirement of products and the application are met all times. Right from inputs to finished products the raw materials are tested from reputed and Govt. Approved test house before processing the finish products. During manufacture all products are subject to DP, Radiographic, Ultrasonic, X-Ray Tests as and when required. All Rotor portion are subject to Dynamic Balancing before assembly as per ISO: 1940. Any further tuning required is carried out by our additional facility of Portable Dynamic Balancing Machine. To ensure meeting guaranteed performances of products we have Testing Laboratory/ Test Beds for testing of fans as per AMCA, BS and IS Standards supported with varied range of measuring instruments with updated calibration Company Philosophy With our established product credibility throughout the country our mission is to keep pace with the continuous and upgradation of technology as per demands of different segment of industry and excel with the product quality simultaneously. In support of our mission we are already an ISO 9001:2008 Certified organisation and our products have been conferred with the certification of the world body of our trade Air Movement and Control Association (AMCA), Illinois, USA for specific range of our product.

CENTRIFUGAL FANS HVAC & General Ventilation TYPE SI, DI 305 mm 2762 mm. Maximum Airflow- 870000 CMH Maximum Static Pressure - 355 MM WG Double width single width non overloading characteristic backward curve impeller. Inlet vane are attached with inlet cone for pre-rotate of inlet air. Extensively used in HVAC System and general ventilation handling of clean or light concentration of fine particles TYPE: AF, SISW & DIDW Single 311mm- 2260mm Maximum Airflow - 850000 CMH Maximum Static Pressure- 355 MM WG Energy efficient hollow aerofoil blade, backward curved, non-overloading characteristic, Width (SW), Double Width (DW). Extensively used in HVAC System handling clean air or with gases containing small amounts of erosive particles TYPE: BI, SISW & DIDW 311mm- 2260mm Maximum Airflow - 585000 CMH Maximum Static Pressure - 355 MM WG Backward Inclined flat blade non-overloading characteristic, Single Width (SW), Double Width (DW). Extensively used in HVAC System and general ventilation of industries. It is suitable for handling gas containing small and medium sized contaminant or humid air and also suitable for elevated temperature

Type: PBI & PAF, SISW & DIDW DW Fan 311 mm- 1245 mm Maximum Airflow -117230 CMH for SW Fan and 177324 CMH for Maximum Static Pressure - 225 for SW Fan and 355 for DW Fan The casing of the fan is a square housing. Standard casing can be used in desired orientation. Backward Curved or Aerofoil Section blades are available for both SISW and DIDW. Extensively used in HVAC System and general ventilation of industries. It is suitable for handling gas containing small and medium sized contaminant or humid air and also suitable for elevated temperature. TYPE: TCL, TUBULAR CENTRIFUGAL FAN 311mm- 1130mm Maximum Airflow- 94200 CMH Maximum Static Pressure- 225 MM WG Backward Aerofoil Blade, non-overloading characteristic (SW). The advantage of this fan is space saving flow section and delivery is in the same axis. It is quite in operation. Extensively used in HVAC System. Fume/Smoke Removal, Boosting of Air, etc. TYPE: SQL, SQUARE INLINE FLOW FAN 311mm -927mm Maximum Airflow 47600 CMH Maximum Static Pressure 114 MM WG Backward Inline limit load non-overloading characteristics, quite in operation, casing of the fan is cabinet type. Extensively used in HVAC system where fan inlet and outlet lie on the same axis. Type DIF, DUCT INLINE FAN Model: DIF-100, DIF-125, DIF-150, DIF-200A, DIF-200B, DIF-250A, DIF-250B, DIF-315A, DIF-315B Maximum Airflow -1100 CMH Maximum Static Pressure- 80 MM WG Forward curved G.I. Sheet blades and casing powder coating finished. 50 and 60 Hz. variations, impeller fitted with external rotor motor Extensively used in HVAC such as hospitals, theatre halls, multiplexes, residents, school building, etc.

INDUSTRIAL FANS Type AH, BACKWARD IN CLINED BLADES, SISW 324mm- 2210mm Maximum Airflow 144000 CMH Maximum Static Pressure 500 MM WG SISW Type Backward curved impeller, higher efficiency fans. Handling of gas containing medium size containment. Used as a Force Draft (FD) and Induce Draft (ID) in the field of Industry. Also used in high temperature application. Type MH, CENTRIFUGAL RADIAL BLADED FAN, SISW 311mm- 2134mm Maximum Airflow 144000 CMH Maximum Static Pressure 500 CMH SISW type radial impeller non-overloading characteristics Handling of fumes, dust particles contained in air. Extensively used in scrubber, cyclone, bag filter as a FD & ID Fan. Also used in high temperature application. Type LS CENTRIFUGAL RADIAL BLADED FAN WITH NO FRONT FLANGE SISW 311mm- 2134mm Maximum Airflow 144000 CMH Maximum Static Pressure 500 MM WG Radial Bladed impeller without front flange, nonoverloading characteristics. It is extensively used in jute, fibre industries where chopping fibre appears in the air.

Type HIB 20 & HIB 24 HI EFFICIENCY INDUSTRIA BACKWARD CURVED FANS. 520mm- 2305mm Maximum Airflow 300000 CMH Maximum Static Pressure 914 MM WG High efficiency backward curved impeller, nonoverloading characteristics. This is extensively used in industrial application as a FD or ID Fan used with bag filter, scrubber, cyclone where dust particles exist in the air. It can operate in high temperature application Type SIAC CENTRIFUGAL BACKWARD AEROFOIL NARROW WIDTH HIGH PRESSURE FAN, SISW required. This is 600mm- 2500mm Maximum Airflow 200000 CMH Maximum Static Pressure: 1200 MM WG High efficiency backward curved aerofoil section blade, non-overloading characteristic These fans are applied best in industries where high volume and high pressure are also suitable for elevated temperatures

AXIAL FLOW FANS HVAC & Industrial TYPE: TL & TS TUBE AXIAL FLOW FAN WITH LONG CASING & SHORT CASING WITH TWO FLANGES. Mounting 300mm 2000 mm. 1250 280000 CMH upto 80 MM WG SP. Duct, Floor & Wall upto 1200 mm dia. Ideal for installation in Hospitals, Schools, Research Labs, Exhaust Air & Supply Air System. It is most often used in HVAC duct system. TYPE: WM WALL MOUNTED AXIAL FLOW FAN WITH INLET CONE AS AN INTEGRAL PART OF THE FAN. Mounting 300 mm 2000 mm. 280000 CMH upto 80 MM WG SP Wall mounting & panel mounting. Same as that of Tube Axial Flow Fan. TYPE: RE ROOF EXTRACTOR/ROOF VENTILATOR Mounting 300 mm 1600 mm. 1250 162000 CMH upto 30MM WG SP Flat or sloping roofs. Roof ventilators are ideal for clean air, low velocity application in both supply and exhaust system.

TYPE: BF BIFURCATED AXIAL FLOW FAN. Mounting 500 mm 1000 mm. 1250 73000 CMH upto 40 MM WG SP Inline Duct and or Wall mounting. These fans are suitable for handling hot, explosive, corrosive and inflammable gases. Motor is enclosed to prevent direct contact with air. TYPE: MC AXIAL FLOW MANCOOLER TUBULAR TYPE. Mounting 450 mm- 1200 mm. 1500 90000 CMH at FAD. Pedestal for standing on floor or bracket mounting Man cooling quiet in operation and reliable to cool selective area or work area. TYPE: APG VANE AXIAL FLOW FAN. Mounting 254 mm 3000 mm. 1500 850000 CMH upto 150 MM WG SP in single & 300 MM WG in double stage. Floor mounting. These fans are generally provided for handling large volume of air at comparatively higher pressure. These are provided with outlet guide vanes and may or may not be provided with inlet guide vanes. These fans are used for surface mine ventilation and industrial process cooling application.

TYPE: AMV AUXILIARY MINE VENTILATION FAN. Mounting 510 mm. 18000 22000 CMH at 250-60 MM WG. Floor, wall bracket mounting. Auxiliary mine ventilation fan are double stage axial flow fan fitted with DGMS flame proof motor. Extensively used in underground mining where inflammable and hazardous gas present in air. TYPE: TSM, SMOKE SPILL FANS Mounting 300mm- 1000mm Maximum Airflow 65000 CMH Maximum Static Pressure 56 MM WG Floor and Ceiling Suspended o Used in case of fire at temperature of 250 C o 300 C for 2hrs. Specially designed thermal rated are used for these fans. Extensively used in Hospitals, Schools, Multiplexes, Hotels, etc.

ACCESSORIES OUTLET DAMPER (Opposed bladed or parallel bladed types) is best suited for control over board range of air volume and are highly efficient in performance. These dampers can be operated manually or automatic VARIABLE INLET VANE DAMPER Designed for accurate control of air volume. The damper will spin the air in the direction of wheel rotation resulting in a maximum saving in power at the reduced ratings desired. COMMON BASE FRAME It is structural steel bases with channels which provides common support to fan, motor and drive including guards.

ACCESS DOOR Access door is provided on the fan casing for inspection and maintenance. Asbestos rope or rubber gasket is used in between fan casing and access door to prevent air leakage. Bolted and quick clamp doors are available. HEAT SLINGER / SHAFT COOLER AND SHAFT SEAL Aluminium shaft cooler is used dissipating heat and protecting bearing from high temperature. Shaft cooler is used generally in fans which handle very high temperature flue gas. HOUSING DRAIN A socket welded at the lowest point of housing scroll for drainage of water in order to protect the fan from rusting.

INLET AND OUTLET SAFETY SCREENS Inlet and Outlet Guard are used for protection of the inlet and the outlet from foreign particles entering the fan. It safe guards the inside of the fan from any outside material to enter through the vents. VIBRATION ISOLATOR Rubber in shear or spring type vibration isolators are available for all sizes and arrangement. BELT GUARD A belt guard protects personnel from the moving drive parts. Both standard and totally enclosed type guards are available.

V-BELT DRIVE SET Drive Set consists of dynamically balanced pulleys and V-Belt. Pulley is made from cast iron or cast sheet material. COUPLING Metal Grid type coupling are used where transmission of high power is required. Tyre type couplings are best for low power transmission; they are also flexible in case of out of alignment FLEXIBLE CONNECTION Plastic impregnated canvas material is generally used for flexible canvas connection where two metal flanges are fitted at both ends. Flexible material such fire proof cloth, rubberised tarpaulin, neoprene rubber for elevated temperature.

MOTORS Along with our fans SIWL offers a wide range of motors for different applications as per customer requirement. The mostly commonly used motor is the Squirrel Cage Type. This is type is used for all general applications and purposes. Another rare type of motor used with our fans is the Slip Ring Type. These motors are used in those fans from which high torque is required such as main mine ventilation fans. TEFC SQUIRREL CAGE MOTOR We Supply Our Equipment with the Following Specifications of Motors Enclosure: Totally Enclosed, Squirrel Cage Motor. Mounting: Foot Mounted, Flange Mounted. Pole: 2, 4, 6, 8, Dual Speed Motor. Insulation: Class 'F'/ 'H' Degree of Protection: IP-55, IP-54, IP-56 Ambient Temperature: o o 45, 50 C Frequency: 50 Hz and 60 Hz supply Efficiency Class: Eff-1 and Eff- 2 Smoke Spill Motor as per BS 7346 Part-2 1940 is used for smoke exhaust o fans. These motors can run for at least 2 hrs and withstand upto 250 C- o 300 C temperature and run for at least 2 hrs in case of fire. Flame Proof Motor is used in hazardous areas where flammable gas and vapour exists such as underground mines, battery rooms, etc. SMOKE SPILL MOTOR Our Regular Brands of Motor Supply are Marathon Electric ABB Bharat Bijlee Ltd. (BBL) Hindustan Motor Havells Laxmi Hydraulic Rotomotive

VITARAN

We are also geared up with Testing facility of Fans as per National and International Standards. a) BIS- 4894 b) BIS-3588 c) AMCA- 210 d) BS-848 Part-I In House Dynamic Balancing Facility In House Testing Facility SUBURBAN INDUSTRIAL WORKS (LESSEE) (PROP. ANUP PAPER INDUSTRIES LTD.) Head office / Works 57/2A, Diamond Harbour Road, Kolkata- 700 023, India. Phone: +91-33-2449 5343, 3292 4010 Telefax: +91-33 2449 5343 Email: siwlkolkata@saralafans.com www.saralafans.com Registered Office: 35A Chaul Patty Road, Kolkata- 700 010, India. Phone: +91-33-2363 9532, 2363 9612 Telefax: +91-33 2363 9532 Email: centaxia_fans@yahoo.com Branch Office: B-82, Sushant Apartments, Sushant Lok, Phase- I, Block- C, Gurgaon- 122002. Haryana, India. Telefax: +91-0124- 4203617 Email: siwlgurgaon@saralafans.com info@newimagegfx.com