HVAC Trajectories toward Zero

Similar documents
2016 Title 24 HVAC Topics. June 4, 2013

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

HVAC Mandatory Provisions Part II, Page 1

COMcheck Software Version Mechanical Compliance Certificate

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

Massachusetts Energy Code Compliance Support Commercial Energy Code Building Mechanical & Service Water Heating Provisions

2009 IECC Commercial Mechanical Requirements

HVAC Controls Upgrades: Requirement Details ( )

COMcheck Software Version Review Mechanical Compliance Certificate

2013 Building Energy Efficiency Standards Workshop

ASHRAE/IESNA Standard

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

High Performance Building Guide 1

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate

HVAC Controls Upgrades: Requirement Details ( )

General HVAC Recommendations

1 - This title will copy onto other forms Date

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

Brief Overview of 2013 Nonresidential Changes to Energy Standards: Mechanical Systems

August 15, 2013 Page 1 of 19

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

C.E.P., C.E.M, C.I.P.E.

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

COMcheck Software Version Mechanical Compliance Certificate

Selected Laboratory Energy Efficiency Measures

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

Mechanical Compliance Certificate

APPLICATION GUIDE BEAMS

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Dehumidifying with Dedicated Outdoor Air

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Job Name Control Systems Description Date

COMcheck Software Version Interior Lighting Compliance Certificate

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

COMcheck Software Version Interior Lighting Compliance Certificate

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

b.) Technical Information:

INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

2018 International Energy Conservation Code (IECC) Updates

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Summary Comparison of Simulation Program Features

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

HVAC 101. H V A C S y s t e m s

COMcheck Software Version Mechanical Compliance Certificate

ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information*

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Digital Precise Air Control - DPAC

4-Pipe VAV vs. Active Chilled Beams for Labs

The Ed Roberts Campus Berkeley, CA

COMcheck Software Version Mechanical Compliance Certificate

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

Business Energy Efficiency Incentives 2007

ENGINEERING. Edition No. 13 October 2002

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

Radiant Cooling Nonresidential HVAC Stakeholder Meeting #2

Variable Refrigeration Flow Systems Overview 10/11/2016

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

Case Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx

COMcheck Software Version

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Application of the 2012 North Carolina Energy Conservation Code

DIGI-VAV APPLICATIONS

Bill McCullough. Director ERV Products. Dallas, TX

Designing Energy Efficient Outdoor Air Systems

UPGRADES. [Energy Efficiency] Base Points

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Water and Space Heating Nonresidential HVAC Stakeholder Meeting #2

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/Dehumidification Devices on the US Market

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Mark Modera (WCEC UC Davis) SWEEP Workshop Tempe AZ November 20, 2014

GARCIA GALUSKA DESOUSA Consulting Engineers

Technical Assignment 3

EnergyGauge USA Release Notes

REQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

Energy Recovery with Cooling and Heating Model ERCH

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

The M & V Guided Recommissioning Process. Energy & Water Conservation Program. September 2015 MOO

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Selection of air conditioning systems

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Hot Water Heating and Distribution Possible CASE Initiatives for 2011 T24 Standards

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

VARIABLE REFRIGERANT FLOW FOR LODGING

A full list of energy conservation opportunities (ECO) for air-conditioned buildings

Transcription:

HVAC Trajectories toward Zero Jon McHugh, McHugh Energy at WCEC Affiliate Forum Western Cooling Efficiency Center Davis, CA May 7, 2013 jon@mchughenergy.com McHugh Energy Consultants

CPUC Big Bold EE Strategies 2

Residential ZNE-Ready Planning 2016 T24 CASE Started 2013 T24 In Effect 2013-14 Program Yr Bridge 2016 T24 Adopted 2015-17 PY 2019 T24 CASE 2016 T24 In Effect Begin with End in Mind. 2019 T24 Adopted 2018-?? PY 2019 T24 In Effect 2013 2014 2015 2016 2017 2018 2019 2020 T-20 Ph-1 T-20 Ph-2 T-20 Ph-3 AB 1109 50% reduction res lighting energy Res NC ZNE Scope for 2020 residential ZNE goal is single family and low rise multi-family Definition of ZNE includes plug loads, thus appliances are very important See Code Driven Portfolios. ACEEE 2012 Summer Study http://www.aceee.org/files/proceedings/2012/data/papers/0193-000177.pdf 3

Nonresidential Buildings Policy Timeline 2008 Title 24 in Effect 2013 Adopted Warehouses 49 kbtu/sf* Schools Small Office 145 92 kbtu/sf Retail - 149 2016 Adopted 2019 College - 160 Adopted Lodging - 167 2022 Adopted Begin with End in Large Office - 203 Mind. Health - 276 Ref Warehouse 211 2025 Adopted Food store - 447 Restaurant - 622 2028 Adopted 2011 2013 2015 2017 2019 2021 2023 2025 2027 2029 T24 Part 6 Energy Efficiency Standards Executive Order B-18-12 AB 1109 50% of New State Buildings ZNE 25% indoor & outdoor lighting reduction All New State Buildings ZNE All New Construction ZNE 50% Existing Building Stock ZNE *Source energy kbtu/sf from CEUS CA Commercial End-Use Survey 4

SEER 10 Innovation: HVAC and Lighting Technology Trajectories Incand PAR 100 W SEER Halogen 13 Required SEER? PAR Economizer IEER?? 90 W HIR + FDD Econ Charge PAR FDD + 75 W Multi-speed VRF VFD Fan CMH PAR 38 W Evap Cond LED PAR 20 W LED PAR 10 W 1990 1994 1998 2002 2006 2010 2014 2018 2022 2026 5

California Climate Zones Coast: CZ s 1, 3, 5, 6, 7 Near Coast CZ s 2, 4, 8, 9 Inland Empire CZ 10 Central Valley CZ 11-13 Desert CZ 14 & 15 Mountains CZ 16 6

2013 Title Residential HVAC HERS verified duct sealing in all CZs. ( 150.0(m)11) Mandatory fan power and airflow testing OR Return duct design (Residential HVAC Quality Installation Improvements). ( 150.0(m)13) Prescriptive refrigerant testing and HERS verification Duct insulation raised from R-4.2 to R-6.0 in climate zones 6, 7, and 8. ( 150.1(c)9) Whole house fan or Smart Vents and Night Breeze as alternatives in CZs 8-14. ( 150.1(c)12) Occupant Controlled Smart Thermostat as a tradeoff against the solar ready zone 7

2013 Title 24 Nonresidential Economizers Prescriptive threshold for economizers lowered Moved from 75,000 Btuh down to 54,000 Btuh (4.5 tons) and > 1,800 cfm of airflow Removed exemptions related to computer equipment and telecommunications Mandatory Fault Detection and Diagnostics (FDD) All air-cooled unitary direct-expansion units with an economizer and Mechanical cooling capacity >= 54,000 Btuh Applies to: Packaged DX rooftops Split-systems Heat pumps Variable refrigerant flow systems 8

Fans Each system listed in Table 140.4-B shall be designed to vary the airflow rate as a function of actual load. Variable Airflow Control of Fans Cooling System Type Fan Motor Size Cooling Capacity Effective Date Direct Expansion any >= 110,000 Btuh Jan 1, 2012 Direct Expansion any > 65,000 Btuh Jan 1, 2015 Chilled Water > ¼ hp any Jan 1, 2012 Evaporative > ¼ hp any Jan 1, 2012 9

Prescriptive Requirements for Computer Rooms 140.9(a) New process measure similar to ASHRAE 90.1-2010 requirements Air or water side economizers required for: Individual computer rooms > 5 tons cooling New systems in existing computer room > 50 tons cooling New system in a new room in existing bldg > 20 tons Simultaneous heating and cooling prohibited Heating water to humidify air not allowed (non-adiabatic) Use evaporative media or ultrasonic humidification (adiabatic) Fan system power 27 W/kBtuh at design conditions Fan speed control for DX > 5 tons and all chilled water systems Fan power 50% design fan power at 66% of design fan speed. Simple payback < 5yr Containment prevent recirculation (return from mixing with supply) 10 10

2013 Title-24 Occupancy Controls Occupancy sensors allowed as a control option for demand control ventilation May reduce the ventilation rate to zero One sensor per room Must do one hour pre-purge prior to normal occupancy Must shut off outside air within 30 minutes of vacancy If single zone system, must also cycle off the fan 11

Occupancy Sensing Thermostats Mandatory Occupancy sensor based HVAC control in: Multipurpose rooms < 1000 sq ft Classrooms > 750 sq ft Conference rooms > 750 sq ft Must automatically setup the cooling set point by 2 F or more and setback the heating temperature set point by 2 F or more and. Automatically reset the minimum required ventilation rate to zero or turn the supply fan off when the zone is unoccupied Hotel/Motel Guestrooms Card key control or occupancy sensing controls to control: thermostat, lights and half of the receptacles. 12

Demand Responsive Communicating Thermostatic Controls All unitary heating and/or cooling systems including heat pumps that are not controlled by a central energy management control system (EMCS) shall have an Overrideable Communicating Thermostat (OCST) 13

2016 Key Residential HVAC and Envelope product development Residential construction patterns that bring ducts out of unconditioned space and address code requirements concerning venting attics to prevent moisture Construction methods that allow thicker exterior insulation while addressing moisture, durability and cost Construction and design practices that increase wall thickness and decrease thermal bridging Training and construction practices that are able to meet QII specs without taking significantly more time. Fault Detection and Diagnostic (FDD) Equipment that can measure refrigerant charge and non-condensibles. FDD already required for nonres economizers 14

Greater Comfort and Energy Savings via Improved Building Envelope Batt or blown insulation Place Ducts in here IAQ must be addressed to tighten envelope and properly ventilate Bring ducts and sealed combustion equipment inside conditioned space Feasible, reliable super-insulation Compressorless comfort home Envelope and building simulation 15 15

Coastal Compressorless Comfort Home Minimum LCC No Forced Air System Reduce loads enough so that AC is not needed Added envelope costs are partially offset by reduced HVAC system costs. Not prohibiting AC but not required Justifies more insulation and better windows in mild CZs Justifies indirect evap cooling in hot climate zones Similar to basis of European Passive House Standard Must have good comfort model in CA Simulation Engine

No Ducts in UnConditioned Space Impacts HVAC equipment Ducts in conditioned space or ductless HVAC Includes conditioned attics, scissor truss, other methods of adding conditioned plenum space, and the use of ductless systems. Different methods of addressing heating in the conditioned space include sealed combustion furnaces, combined water heating and space heating and heat pumps. Simulation of ducts in conditioned space group of measures conditioned attic space, ducts in conditioned spaces, ductless systems, sealed combustion, combined heating and water heating and how does it impact efficiency of condensing water heaters. VRF and CV mini-split Develop methodology and rating data needed to provide accurate model of water heating for VRF. 17

Res Ventilation Controlled supply mechanical ventilation Evaluate the costs, the energy benefits and the air quality benefits from replacing exhaust based ventilation with supply based ventilation Heat recovery ventilation Evaluate whether heat recovery ventilators are cost-effective in the more extreme climate zones and develop a proposal if so. This would replace the other mechanical ventilation requirements. 18

Res HVAC Measures Dual path - higher HVAC efficiency in alternative path include higher HVAC efficiency in alternate path FDD/CID refrigerant charge/condensables (2016?) Propose a requirement for FDD that would verify proper refrigerant charge, lack of condensables in the system and proper airflow. Evaporative cooling baseline hot/dry CZs Evaluate and develop and evaporative cooling code baseline for homes in hot/dry climate zones 19

Avoiding Preemption: Multiple Path Energy Codes Prescriptive Paths Standard Path(s) Alternate Path(s) Performance (Software) Approach Photovoltaics or Large Impact Efficiency Measure Reduced or no PV required or other Eff Measure Photovoltaics or Large Impact Efficiency Measure Minimum Federal Efficiency Equipment Higher Efficiency Equipment than Fed Min Eff Minimum Federal Efficiency Equipment Other Common Efficiency Measures Other Common Efficiency Measures Other Common Efficiency Measures At least one standard path for every alternate path with higher efficiencies See Federal Appliance Standards Should be the Floor, Not the Ceiling ACEEE 2012 Summer Study http://www.aceee.org/files/proceedings/2012/data/papers/0193-000415.pdf 20

Dual Path Approach and BEARS Dual path approach PV vs. high eff equipment PV in base case: trade-off with equip eff: HVAC, water heating, refrigeration PV model offsets consumption Performance method base case with PV and method for trade-offs BEARS (Building Energy Asset Rating) System) whole building rating model including deemed plug loads. Evaluate plug load data from a number of sources including CEUS and COMNET and incorporate into ACM so that performance runs also generates a BEARS design rating ZNE: BEARS = 0 21

Nonres HVAC measures Low W/sf HVAC systems Limit connected HVAC connected load. Don't double count interlocked loads. Consider a fan efficiency requirement or W/cfm requirement Heat recovery Heat recovery with thresholds by cfm of O/A and climate zone ACM - Base Case HVAC rule set Performance rule set without exceptions (VAV reheat?), max W/sf, validated EPlus algorithms, base case and proposed case when AC not used, comfort model. Economizer simulation model for two speed AC. ACM - Improved and validated VRF simulation Rigorous method of incorporating VRF test data into simulation that results in accurate estimate of energy impact. ACM - VAV w/reheat, integration with DCV, chilled beam and DCV. Validate and improve Eplus simulation of nonresidential HVAC simulation types. Compare to equest and rationalize or fix the discrepancies 22

Advanced HVAC Improved Natural Ventilation and displacement ventilation simulation Evaluate Eplus natural ventilation model and make recommendations for the ACM. Evaluate the feasibility and costeffectiveness of a natural ventilation and displacement ventilation base case by climate zone.. Radiant model including comfort Evaluate Eplus radiant heating/cooling model and make recommendations for the ACM. Update Eplus model if necessary. Adjust setpoint temperatures based on ASHRAE 55 and operant temperature. 23

Process - Fume Hoods & Computer Rooms Lab fume hoods, Occupancy sensing control of sash Evaluate the feasibility and cost-effectiveness of an automatic control of vent hood sashes. Similar to automatic doors at stores Requires VAV fume hood exhaust system Lab HVAC measures reset general room airflow rate and setpoint when unoccupied after hours, max W/cfm at peak air flow, no simultaneous heating and cooling (dual duct, chilled beam, 4PFC etc.,), Internal gains in labs can vary widely over time and they become the rogue zone sizing calculated, exhaust duct sealing. Computer rooms Economizers on smaller equipment Measures applied to smaller computer rooms and data centers 24

Opportunities ahead Aggressive goals for 2020, 2025 and 2030 $2.6 Billion for school energy upgrades over the next 5 years (2013-2018) Prop 39 Significant changes to 2013 Title 24 Significant niches in eff HVAC and controls Similar changes from ASHRAE 90.1 and IECC New opportunities for 2016 codes Emphasis on individual measures Incremental cost Energy savings Feasibility Enforceability (ratings etc.) 25