Challenges and responses in refrigerant conversion

Similar documents
Transitioning to Alternatives and Challenges in Japan

Member Briefing JAPAN

Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants

Transitioning to Alternatives and Challenges in Japan

The 10 th Three Associations Meeting JRAIA. The Japan Refrigeration and Air Conditioning Industry Association. August 31, 2016.

Actions to Control Emission of HFCs in Japan

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Japanese market and issue of Heat Pump Kenji Matsuda

History of Kobe Symposium And Global Issues of the HVAC Industry

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

A2L Refrigerants. Objectives 14/09/2017

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

The Current Path of Refrigerants

Policies and Measures for HCFCs in Japan

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

International New Technology and Refrigerant Symposium

Effectively Managing the Transition to Lower GWP Refrigerants

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Effectively Managing the Transition to Lower GWP Refrigerants

Overview of New Refrigerants and Expected Market Trends

New Refrigerants Designation and Safety Classifications

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Requirements of refrigerant leak detector and alarm for air conditioning and refrigeration equipment

Natural refrigerant trends in EU, Japan & North America

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Making equipment decisions

Flammability and the Low GWP Refrigerant Challenge

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Update on Codes and Standards Research. Karim Amrane, Ph.D. Senior Vice President

Research for the Development of Safety Standards

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Refrigerant and Energy Regulations Update

Refrigerant & Energy Regulations Update

Contents TERI. Part I Background. Part II Introduction of Research on Flammability of Lower GWP Refrigerantds by TERI.

Cooling Only & Heat Pump

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

FACT SHEET 6 Transport Refrigeration

The impact of legislation and trends for the industry

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Development of centrifugal chiller and heat pump using low GWP refrigerant

Refrigerant and Energy Regulations Update

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

Flammability and New Refrigerant Options

Refrigerant Sustainable Future IZW e.v. Technische Universität Dresden

Challenges from flammability concerns and related safety standards, possibilities for compact systems limiting charge sizes

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Global Solutions for Ammonia Industrial Refrigeration

Standards and Regulations Update for Flammable Refrigerants

Gary Parker Refrigerants Product Manager

Refrigerant options now and in the future

The natural solution for domestic refrigeration

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Embraco Position Paper: Light Commercial Refrigeration

Refrigerant options now and in the future

CHAPTER 1 INTRODUCTION

Refrigerant options now and in the future

Refrigerants & Cooling in renovation buildings

Safety standards relevant to Refrigeration, Air-Conditioning and Heat Pump equipment

Safety research of A2L/A3 refrigerants and risk assessment in Japan. Eiji Hihara The University of Tokyo

New Refrigerants & Selecting Capital Equipment

Scroll Chillers Transition from HCFC-22 to HFCs

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression Specification reference:

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Making Sense of the Latest Rulemaking on Acceptable Refrigerants. E360 Webinar

CHAPTER 1 INTRODUCTION

Development of centrifugal chiller and heat pump using low GWP refrigerant

Understanding Applications for Alternative Refrigerants

Research to Assist in the Development of Safety Standards and Building Codes for the Use of Flammable Refrigerants

Low GWP Refrigerants for Air Conditioning Applications

Grow your business: Get ready for flammable refrigerants!

Refrigerant Rule Update

Gary Parker Refrigerants Product Manager

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

This presentation is posted for public use. ACEEE does not endorse any product or service.

Alternative Refrigerants Part 1 Future and Current Options. Overview

Refrigerant options now and in the future

Information Guide Maintenance and Refrigerant Regulations. Issue 35

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

ASHRAE Standard 15: Proposed Changes to Incorporate 2L Refrigerants

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Stakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Low GWP alternative refrigerants to R404A

Safety concerns for A2L refrigerants in AC service procedures

Meeting the Challenges of the EU HFC Phase-Down

Ozone Depleting Substances (ODS) Rule Updates

Natural Refrigerant Market Trends

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

AIRAH Victoria Refrigerants Update

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Transcription:

OEWG 39 Side Event Challenges and responses in refrigerant conversion Tetsuji Okada JRAIA 12. July. 2017

Contents: 1. Who is JRAIA? 2. Trend of legislation and Protocols 3. Market trend 4. Strategies to be taken as Japan 5. HFC step down 6. Refrigerant management in Japan

Contents: 1. Who is JRAIA? 2. Trend of legislation and Protocols 3. Market trend 4. Strategies to be taken as Japan 5. HFC step down 6. Refrigerant management in Japan

1. Who is JRAIA? Overview The Japan Refrigeration and Air conditioning Industry Association (JRAIA) Established in 1949. 168 member companies including the associate members. (as of 1 st of June 2017) The business fields of the member companies are : - Air conditioning (residential, commercial, automotive) - Refrigeration (commercial, industrial, transport) - Ventilation - Heat pump system (HP water heaters) - Refrigerants - Parts

Contents: 1. Who is JRAIA? 2. Trend of legislation and Protocols 3. Market trend 4. Strategies to be taken as Japan 5. HFC step down 6. Refrigerant management in Japan

2. Trend of legislation and Protocols 1) Timeline in Japan 1985 1990 1995 2000 2005 2010 2015 Vienna Convention Dubai Pathway. Global Montreal Protocol UNFCCC Kyoto Protocol(COP3) Kigali Amendment Paris Agreement(COP21).. Japan Global Warming Countermeasure Plan Ozone Layer Protection Law Revised OLP Law HCFC produce regulation starts (2018) HFC introduction EoL Automotive Recycle Act Revised Fgas Act (2015) Home Appliance Recycle Act Fluorocarbon Recovery &Destruction Act Amendment

2. Trend of legislation and Protocols 2) Regulation of refrigerant by "designated products" in Japan Regulated by Act on Rational Use and Proper Management of Fluorocarbons Designated Products Target GWP (Weighted Average GWP) Target year Room air conditioning (Mini-Split) 750 2018 Commercial air conditioning (Split) 750 2020 Mobile air conditioning 150 2023 Condensing unit and refrigerating unit 1500 2025 Cold storage warehouses 100 2019 Urethane foam 100 2020 RACHP sectors Dust blowers 10 2019

2. Trend of legislation and Protocols 3) HFC phase down latest status in Japan % 120 HFC phase down now 10 yr later 20 yr later 30 yr later freeze NonA5 A5-G1 A5-G2 100 80 60 We can keep this line when the refrigerants in the designated products will be changed to new one. 40 20 +HCFC 15% +HCFC 65% +HCFC 65% HFC B.L. Non A5 HFC B.L. A5-G1 HFC B.L. A5-G2 0 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050

2. Trend of legislation and Protocols 4) Comparison of safety act U.S. Europe Japan Legislation/ Act Clean Air Act SNAP F Gas Regulation, Act Act on Rational Use and Proper Management of Fluorocarbons High pressure gas safety act National legislation Building Code IMC, UMC, etc. Building Code High pressure gas safety act International standards Standard / regulations (define ref types) Standard / regulations (safety) ASHRAE34 ASHRAE15 UL60335-2-40 UL484, etc. ISO817(refrigerant classification) Relevant standards based on ISO EN378 EN60335-2-40 ISO5149(safety) High pressure gas safety act High pressure gas safety act JIS C9335-2-40 JRA standards, etc.

2. Trend of legislation and Protocols 4) Comparison of safety act Legislation/ Act National legislation International standards Standard / regulations (define ref types) Standard / regulations (safety) Clean Air Act SNAP ASHRAE34 ASHRAE15 UL60335-2-40 UL484, etc. U.S. Europe Japan F Gas Regulation, Act Relevant standards based on ISO EN378 EN60335-2-40 Act on Rational Use and Proper Management of Fluorocarbons High pressure gas safety act What is High Pressure Gas Safety Act? Building Code Building Code High pressure gas safety act This act is IMC, the UMC, regulation etc. for high pressure gas, but covers toxicity and flammability of the refrigerants, and applies to HVAC equipment of the size ISO817(refrigerant classification) ISO5149(safety) above certain refrigerant volume. High pressure gas safety act High pressure gas safety act JIS C9335-2-40 JRA standards, etc.

Contents: 1. Who is JRAIA? 2. Trend of legislation and Protocols 3. Market trend 4. Strategies to be taken as Japan 5. HFC step down 6. Refrigerant management in Japan

3. Market trend 1) Refrigerant conversion status in each product sector Product Category Number of Units in 2016FY (in thousands) Y/Y Ratio (%) Refrigerant Residential air conditioners 8,527.5 104.4 Commercial air conditioners 793.9 102.6 Residential heat pump water heaters 424.4 104.1 R410A>>R32 (almost 100%) R410A>>R32 (only Small-size; 41%) CO 2, (R32) (almost 100%) Gas engine-driven air conditioners 30.5 98.1 R410A Water chilling units 12.9 98.8 R410A,R134A Air to air heat exchangers 109.2 93.2 NA Commercial refrigerated cabinets 312.4 101.4 R404>>R410A, CO 2 Condensing units 91.3 98.3 R410A Refrigeration units 29.7 102.2 R22>>NH 3,(+CO 2 )

3. Market trend 2) World market trend of air conditioners (2016;102.31M-units) xx% : A2L refrigerant ratio(unit) 4% Nearly 100% 41% 20% 24% 1%

Contents: 1. Who is JRAIA? 2. Trend of legislation and Protocols 3. Market trend 4. Strategies to be taken as Japan 5. HFC step down 6. Refrigerant management in Japan

4. Strategies to be taken as Japan 1) JRAIA s Vision and Activities on Environmental Conservation EQUIPMENT Energy Saving Emission control on a CO2 basis REFRIGERANTS Direct Emission Control Promotion of recovery Measures against leakage (proper management of refrigerants) Reduction of amount charged into equipment ALTERNATE REFRIGERANTS Acceleration to shift to new refrigerants Research of low GWP refrigerants Risk Assessment Top Runner Program Act on Rational Use & Proper Management of Fluorocarbons Home Appliances Recycling Act EoL Automotie Recycling Act High Pressure Gas Safety Act

4. Strategies to be taken as Japan 2) Points for Refrigerants Conversion Actions to phase down HFCs have been started sector by sector in Japan by considering not only environment performance but also safety, energy efficiency and economic feasibility. S+3Es Safety (precondition) Environment Performance Energy Efficiency Economic Feasibility Low Toxicity Low Risk of Flammability Ozone Depletion Potential =0 Low Global Warming Potential(GWP) Superior for LCCP* value Similar performance at high load cooling Reasonable Cost Acceptable level in Developing Countries LCCP*:Life Cycle Climate Performance

Contents: 1. Who is JRAIA? 2. Trend of legislation and Protocols 3. Market trend 4. Strategies to be taken as Japan 5. HFC step down 6. Refrigerant management in Japan

5. HFC step down 1) Steps to execute HFC reduction plan :challenges and response Step 1 Selection of candidate refrigerant Step 2 Confirmation of equipment safety Step 3 Confirmation of safety standards Basic physical properties (energy efficiency), compatibility with lubricating oil, etc. Efficiency evaluation, confirmation of reliability etc. Low GWP refrigerant has flammability. Risk assessment by product (Life cycle perspective, region by region) Development of new standards and guidelines by risk assessment Association for Evaluation of A2L Refrigerant by Industry- Government-Academia Collaboration Design complying with IEC, ISO and national standards Amendment of standard itself Especially concerning the mildly flammability, it is a new concept

5. HFC step down 2) Steps to execute HFC reduction plan :challenges and response Step 4 Confirmation of safety regulations Step 5 Market acceptability Step 6 Expanding penetration into the market Partial relaxation of Building Codes, High Pressure Gas Safety Act (in Japan) Security guarantee based on the above new standards and guidelines Addition of new category from the viewpoint of flammability Overcoming the additional issues related to the rising product price by installation of risks and installation work, understanding of the market is indispensable Example of risk countermeasure: installation of ventilator, gas sensor, installation of shutoff valve etc briefing sessions for the market, measures to promote penetration Overcoming economic issues (cost increase etc.) Level of capital investment due to alternative refrigerant

5. HFC step down 3) Step toward revision of classification for A2L refrigerants (legislations to assure safety) Step toward revision 2011 Nov. 2016 Step1: Evaluation of Performance (Efficiency) Step2: Risk Assessment Step5, 6: Market launch Including product and installation, etc. Legal action JRA standards & guidelines Step4: High Pressure Gas Safety Act Building Act Fire Service Act Activities of the committee for the risk assessment of mildly flammable refrigerants Step3: IEC, ISO revised Japan Global

5. HFC step down 4) Main Point of the mitigation of High pressure gas safety Act 1. Revised classification A2L refrigerants.(r32, R1234yf, R1234zd) 2. Reference of JRA Standards and Guidelines. Refrigerants(former) Fluorocarbon (inert gas) Fluorocarbon, Fluorocarbon, NH3 NH3 (excluding (excl. inert inert gas) gas) Others(CO2,A3) Others(CO2, A3) No need of Notification or Approval for present refrigerant. Notification or Approval for A2L are needed same as other refrigerants.

5. HFC step down 4) Main Point of the mitigation of High pressure gas safety Act 1. Revised classification A2L refrigerants.(r32, R1234yf, R1234zd) 2. Reference of JRA Standards and Guidelines. Refrigerants(former) Fluorocarbon (inert (inert gas, gas) CO2,) Fluorocarbon, NH3 (particular (excl. inert inert gas) gas) R32, R1234yf, R1234zd Others(CO2,A3) Fluorocarbon, NH3 (excl. inert gas) A2L: Newly categorized No need of Notification or Approval for A2L same as present refrigerants. Others(A3)

5. HFC step down 5) JRA Standards and Guidelines(1) products the refrigerant charge equipment refrigerant leak detector and alarm refrigerant leakage from refrigerating and air conditioning equipment No. of Std. or GL. JRA GL20 JRA 4068 JRA GL14 Title Appropriate measures to prevent combustion against refrigerant gas leakage from the refrigerant charge equipment using semi-inert gas Requirements of refrigerant leak detector and alarm for air conditioning and refrigeration equipment Guideline for prevention of refrigerant leakage from refrigerating and air conditioning equipment and systems using fluolocarbon chiller JRA GL15 Guideline of design construction for ensuring safety against refrigerant leakage from chiller using lower flammability(a2l) refrigerants commercial air conditioners JRA 4070 JRA GL16 Requirements for ensuring safety against refrigerant leakage from commercial air conditioners using lower flammability(a2l) refrigerants Guideline of design construction for ensuring safety against refrigerant leakage from commercial air conditioners using lower flammability(a2l) refrigerants References ISO 817 ISO 5149-1, -3:2014 IEC 6033-2-40 61D/338/INF:2016 ISO 5149-1, -3:2014 ISO 14903 ISO 5149-2, -3, -4 IEC 60335-2-40 IEC 60079-10-1 ISO 5149-1, -2, -3, -4 ISO 5149-1/Amd1 ISO 5149-1, -2, -3, -4 ISO 5149-1/Amd1

5. HFC step down 6) JRA Standards and Guidelines(2) products No. of Std. or GL. Title References commercial refrigeration equipment JRA 4072 Requirements for ensuring safety against refrigerant leakage from commercial refrigeration equipment using lower flammability(a2l) refrigerants ISO 14903 IEC 60079-10-1:2015 IEC 60335-2-40:2013 JRA GL18 Guideline of design construction for ensuring safety against refrigerant leakage from commercial refrigeration equipment using lower flammability(a2l) refrigerants ISO 5149-1 IEC 60079-10-1:2015 IEC 60335-2-40:2013 IEC 60335-2-40 61D/338/INF:2016 commercial packaged air conditioner JRA 4073 Requirements for ensuring safety against refrigerant leakage from commercial packaged air conditioner for facilities using lower flammability(a2l) refrigerants IEC 60335-2-40 61D/338/INF:2016 JRA GL19 Guideline of design construction for ensuring safety against refrigerant leakage from commercial packaged air conditioner for facilities using lower flammability(a2l) refrigerants IEC 60335-2-40 61D/338/INF:2016

Contents: 1. Who is JRAIA? 2. Trend of legislation and Protocols 3. Market trend 4. Strategies to be taken as Japan 5. HFC step down 6. Refrigerant management in Japan

6. Refrigerant management in Japan 1) Market response (refrigerant management) < Based on the revised F-gas act > (Not limited to flammable refrigerants) 1. Inspection system (user) legal regulation Require periodic inspection for equipment with a certain capacity or more 2. Improve the level of contractors Operate with private qualification Lecture implementation, qualification acquisition 3. Qualifications of collection / destruction traders, certification registration system for local governments 4. (Efforts as Industrial Association) Formulation of leakage prevention guidelines

Summary 1. Example of the measures for HFC step down in Japan is shown. (Effect of industry-academia-government collaboration) 2. Risk assessment is the key issue for each product sector and each country. ( especially refrigerant life cycle and regionality) 3. It is needed to share the results of risk assessment in each region. 4. It is very important to assure safety and to mitigate the safety codes of each nation by using the results of risk assessment.

Thank you for your kind attention!!