Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

Similar documents
SULPHUR RECOVERY UNIT

DELTA-TE III. Nozzle-mix line burner

Chemical Processes in the Combustion

OPERATING AND MAINTENANCE MANUAL

Document code: 1 (10) Issuing date: Status:

PACKAGED METALLIC BURNERS

NMC Nozzle Mix Gas/Oil Combination Burners

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

INDITHERM. Low temperature gas burners

Specifications of V-Line burners

Fireye FLAME SCANNERS

"HC" AIRFLO. In-duct firing line burner

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

INDITHERM. Low temperature gas burners

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Eclipse Self-Check UV Scanner

FIREYE FLAME SCANNERS

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Power Flame Incorporated

FLAT FLAME AND EXCESS AIR BURNERS

Steam Fundamentals. (in heating & processing applications)

COMPACT FLAME CONTROLLER CFC 1000

FIREYE C9707A ALL FUEL SCANNER

COMPACT FLAME CONTROLLER CFC 2000

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

Burners Flares Incinerators Vapor Combustion

MULTIPLEX SELF RECUPERATIVE gas burner

ECLIPSE INFORMATION GUIDE

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Specifications of MULTIFIRE burners

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Distributed By: M&M Control Service, INC

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

HEADLINE LOREM IPSUM COMPANY EFFICIENCY

NMG NOZZLE MIX GAS BURNERS

Fired Heater Flooding

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Distributed By: M&M Control Service, INC

SECTION HEATING BOILERS

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

FIREYE FLAME SCANNERS

DESCRIPTION AND INSTALLATION

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Indirect gas-fired air heater

Gas-Fired Indoor and Outdoor Duct Furnaces

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

THE WORLD S FIRST FLAMELESS CRUDE HEATER

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

THERMAX Efficiency Monitor

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

26 Mesh Belt Brazing Annealing Furnace. Continuous Mesh Belt Brazing Furnace

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

FIREYE FLAME SCANNERS

COMPACT FLAME CONTROLLER CFC 100

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

MEGASTAR TM BURNER MS-25 MS-150

Installation & Troubleshooting Requirements

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

"NP" & "RG" AIRFLO. In-duct firing line burner

FIREYE FLAME SCANNERS

V-Line. Nozzle-mix line burner

W-FLAME IR/UV FLAME DETECTOR

5.0 ALARMS & TROUBLESHOOTING

Products & Services. DISTRIBUTOR & FOREHEARTH SYSTEMS

ECLIPSE INFORMATION GUIDE

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Galvanizing Line with Continuous Anneal Capabilities

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Type CG Series Forced Draft Gas Burner

Overview of Gas Range Types

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Glossary. Carbon Dioxide (CO 2

Product Overview Combustion Technology

UV - flame detector dual fuel burners for intermittent burner operations

U n i t H e at e r s

PVE SERIES POWER VENTER SYSTEM MANUAL

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Flame Safeguard Fault Code Diagnostics

DESCRIPTION AND INSTALLATION

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Downsizing after Retrofit

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Flame Monitors BROCHURE

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Eclipse RatioMatic Burners

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

FLAME SAFEGUARD & COMBUSTION CONTROLS. Preface

Transcription:

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

Main Burner

Main Reaction Furnace Design Weather shield View ports Weather shield LMV Burner Burner / Furnace connection Residence time section Checker wall / Choke ring WHB connection Temp. Measurement Man way

Refractory Lining

dry-out Main burner type155 Natural Gas / excess air 120 100 Total air flow x 100 Nm3/hr Total NG flow x 10 Nm3/hr Delta P burner /10 mbarg Temperature x 10 deg ºC 40 deg /hr 80 60 40 20 0 0,00 1,00 2,00 4,00 5,00 6,00 7,00 9,00 10,00 11,00 12,00 14,00 15,00 16,00 17,00 19,00 20,00 21,00 22,00 0,00 1,00 2,00 3,00 5,00 6,00 7,00 8,00 10,00 11,00 12,00 13,00 15,00 16,00 17,00 18,00 Time in hr

Start-up and Dry-out Clean Unit Open the WHB vent to atmosphere

Refractory Lining

Start-up and Dry-out Clean Unit Air dry by use of air blower temperature (70 C) Purge system with nitrogen Start the main burner at 5 to 25 % of max fuel gas load Burner pressure drop approx 25 mmwc After ignition: drop fuel gas as low possible / increase combustion air After 15 to 30 minutes : stop burner, check temperature curve (fast rise and drop indicates flue gas temperature) Follow the temperature curve for dry out - TAKE YOUR TIME At approx 800 C change the ratio to sub-stoichiometric conditions

Start-up and Dry-out under Sulphur Conditions Open the WHB vent to atmosphere Air dry by use of air blower temperature (70 C) Purge system with nitrogen Start the main burner 15 to 25% of max fuel gas load Use Air / gas ratio at sub stoichiometric conditions. After ignition drop burner load to minimum of 10 mmwc combustion air pressure. To moderate temperature use nitrogen or steam. Follow the temperature curve for dry out. TAKE YOUR TIME

Tips, Tricks and Troubleshooting Open the WHB vent to atmosphere (this will drop WHB outlet temperature and allows to operate with excess air) In-line burners Flame colour: Know your gas composition! Natural Gas (C1) gives a blue-pink salmon colour at substoichiometric conditions Propane (C3) gives a more blue-yellow flame at substoichiometric conditions Raise combustion air flow approx 5%: if this results in a temperature rise of 4 to 8 F you are running substoichiometic Starting the RGG/TGT/SCOT: have all systems running and prepare extra cooling

Duiker DFD 2 Flame detector 21

The Flame Signal can be split into the following information: Radiation Modulation Electro Magnetic Radiation Light (UV, VIS & IR) Mixing Process Flame Flickering 2012 Duiker Sulphur Recovery Unit 22

Duiker DFD 2 Flame detector T1 Delta T2 23

Duiker DFD 2 Flame detector 24

Duiker DFD 2 flame detector Data logger 27

Duiker DFD 2 flame detector Data logger 28

Main Burner

LMV Burner Principle Airnose Combustion air Register Fuel gas Pilot burner or ignitor Acid gas Acid fuel gas gun

Burner Turndown Burner turndown is determined by the minimal flow through the burner restriction P of acid gas + air + (fuel gas) 0,15 kpa Design capacity is based on max. allowable P of acid gas and air (Max. 10 kpa).

Oxygen Enrichment Rich Acid Gas Fuel gas Rich acid gas Air O 2

In-line Burners

Overall View - Reheater

Multiple in-line burners with pneumatically retractable ignitors

Incinerator

Tail Gas Incinerators

SRU tail gas incinerator being commissioned

Mixing (Typical) Temperature and velocity profile of incinerator with inlet nozzles

Low NO X Incinerator Burners

Different Flame Scanner Systems UV scanners IR scanner T scanner + Low cost scanner - Needs shutter system for safe guarding - Poor or no flame signal with steam injection + Low cost scanner - Poor or no flame signal FG firing + No influence on steam / nitrogen injection - High cost scanner Combination scanner

How to Detect a Flame? Radiant Sensitivity (A/W) 200 400 600 800 1000 Wavelength (nm) UV-tube GaP without filter GaP with UV-filter Silicon Spectral sensitivity range of the scanner

Dos and Don ts Never remove a scanner wit a open ball valve as acid gas can come out Checking the sight port for pollution: Exchange the position of the scanner and a sight glass Run scanner cables through steel pipe in order to avoid radiation in the cable (fail-safe self check) Avoid potential difference in ground systems (welding / igniting) Avoid strong radio signals close to the scanner / cable / amplifier Avoid temperature rise above 70 deg. C Check purge flow (min. 10 m 3 /h) and clean lens systems

Different Types of Thermocouples

Different Types of Thermocouples

Different Types of Pyrometers

Ignition Systems: Pilot Burner The pilot burner is a small self supporting burner Gas pressure : 1,0 bar, air pressure 1,2 bar.

Pilot Burner Flames

Ignition Systems: Igniter

Duiker-Durag Unit generates 1500 volts Unit retracted during operation Operational life time of the tip is 14 hours of sparking

Start-up and Dry-out of Clean Unit Close WHB blow off Start inline burners. Use same ratio conditions as found for the main burner Extra caution you have to rely on instruments only, use if possible a sacrifice type K thermocouple to monitor burner temperature Take your time

Duiker Field Services

Bright Yellow Sulphur

Thank you for your kind attention For more information: www.duiker.com