ULTRASONIC (SONIC) CLEANING ENHANCES THE INSTRUMENT

Similar documents
STERILIZATION IS A KEY RESPONSIBILITY OF THE INSTRUMENT

STERILIZATION IS A KEY RESPONSIBILITY OF THE INSTRUMENT

MANUAL CLEANING IS A VERY IMPORTANT PART OF THE

DEVICES THAT HAVE NOT BEEN ADEQUATELY CLEANED CANNOT

Decontamination. CIS Self-Study Lesson Plan Lesson No. CIS 244 (Instrument Continuing Education - ICE)

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

When you sterilize an instrument set, you know what the standards are.

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

THE BASICS OF DECONTAMINATION

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

Sterile Processing. Knowledge, Skills, Competencies. Terri Goodman, PhD, RN

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

FLASH PAK STERILIZATION CONTAINER SYSTEM

The Principles, The Process, and The Results:

Instructions for Use Spinal Punches IFU

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

STERITITE INSTRUCTIONS FOR USE

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

Surgical Instrument Cleaning Process

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Ultrasonic From delicate microsurgery instruments to heavy duty sets

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

Cleaning & Sterilization

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Turbo Sonic Raytech. Ultrasonic Cleaner. Operating Instructions

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

2015 Myco Industries, Inc Fax:

Cleaning Verification

Operating / User Manual

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

CLEANING INSTRUCTIONS

TR Shower Panel. Operating manual. Hygiene Equipment Designed for People. Serial Number:

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

Before digging into the 10 things you should know let s start with a brief explanation of the process.

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

ANSI/AAMI ST79: Comprehensive guide to steam sterilization and sterility assurance in health care facilities. Suzanne Latta, CSPDT

Infection Prevention and Control N/A. Executive Director of Nursing and Quality, DIPC. IPC Governance Meeting Members

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

Harvey Chemiclave 5000 Owner And Operator Guide

CLEANING OF INSTRUMENTS

Aesculap Implant Systems

Cavitator Ultrasonic Cleaners

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

RECOMMENDATIONS FOR CLEANING DEVICES

Classification of Instruments -

4/8/2014 GOAL PATIENT EQUIPMENT

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Sterling P1500 Washer-Disinf ec t or Acce s s or y Guide

Celebrating over 30 years of excellence in manufacturing ultrasonic cleaning equipment, electropolishing equipment and associated chemistries

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Whittemore Ultrasonic Cleaner

Precision Ultrasonic Cleaning Equipment Buyers Guide

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

LOGIC CONTROLLED DEKO 25 EASE OF USE

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)


Lower Your Costs. Expand Your Flexibility.

Aesculap Implant Systems

Lyman. Turbo Sonic 700. Ultrasonic Cleaner. Operating Instructions

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Cavitator Ultrasonic Cleaners

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

Washer Test Kits User Guide

Instruction Manual for Bench-Top Cleaning Baths

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

8/18/2014. Welcome! How do I get a CE Certificate?

AIR FORCE EXTREME LITHIUM-ION

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Cavitator Ultrasonic Cleaner Instruction Manual

ENDOSCOPE DECONTAMINATION : Where are we now!

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

Wet Packs: Are They Sterile? Rose E. Seavey, MBA, BS, RN, CNOR, CRCST

PERFORM Operating Document

Table of Contents. English

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

Recommendations for cleaning, decontamination and sterilisation. devices

Sonic Irrigator DIGITAL Cannulated Instrument Cleaner

QuickStart Guide. Automated Support Removal System. PostProcess Technologies, Inc. REV C

Operating manual. Instrument washer. MELAclean. Thank you very much for the trust that you have shown in our products by purchasing this unit.

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

Transcription:

CRCST Self-Study Lesson Plan Lesson No. CRCST 153 (Technical Continuing Education - TCE) Sponsored by: by Ava Griffin, BSN, RN, CNOR CSP Educator University of Chicago and Patti Koncur IAHCSMM Education Specialist Basics of Ultrasonic Cleaning LEARNING OBJECTIVES 1. Understand the importance of ultrasonic cleaning 2. Learn how to prepare the ultrasonic unit for cleaning 3. Learn how to prepare instruments for ultrasonic cleaning 4. Understand the safety measures that apply to ultrasonic cleaning ULTRASONIC (SONIC) CLEANING ENHANCES THE INSTRUMENT cleaning process by cleaning complex, hard-to-clean areas of medical devices. The cavitation (cleaning) process can be enhanced or hindered by many factors, including manual cleaning, solutions used, instrument complexity, and the adherence to proper loading and maintenance instructions. Staff knowledge regarding the ultrasonic cleaning process is critical for ensuring proper instrument cleaning. This lesson plan will address the important factors necessary for the proper use of ultrasonic cleaning processes. OBJECTIVE 1: UNDERSTAND THE IMPORTANCE OF ULTRASONIC CLEANING An ultrasonic cleaner is a type of mechanical cleaning device used for fine cleaning of instrumentation and other medical devices. It is especially effective in cleaning difficult-to-clean areas, such as joints, crevices, box locks, hinges, spring areas and lumens. Ultrasonic cleaners are used in healthcare and electronics applications, as well as for cleaning jewelry. This mechanical cleaning process removes soil from instrumentation through a process of cavitation and implosion. Sound waves produce small gas bubbles that grow and then implode, creating a vacuum that draws out trapped debris from hinges, serrations and other hard-to-reach areas. The bubble implosion creates a cleaning action that disrupts the bond that causes soil to adhere to the instrument surfaces, thereby, pulling the debris away from the instrument surface. Sonic cleaners do not disinfect or sterilize instruments; however, when used in conjunction with manual cleaning, sonic cleaning can enhance the cleaning process and increase the bactericidal effectiveness of the disinfection and sterilization processes. This series of self-study lessons on CS topics was developed by the International Association of Healthcare Central Service Materiel Management (IAHCSMM). Purdue University s Extended Campus and IAHCSMM both offer grading opportunities. Earn Continuing Education Credits: Online: Visit www.iahcsmm.org for online grading at a nominal fee. By mail: For written grading of individual lessons, send completed quiz and $15 to: PEC Business Office, Purdue University, Stewart Center Room 110, 128 Memorial Mall, West Lafayette, IN 47907-2034. Scoring: Each quiz graded online at www.iahcsmm.org or through Purdue University, with a passing score of 70% or higher, is worth two points (2 contact hours) toward CRCST re-certification (12 points). Subscription Series: From January 1 to June 30 each year, Purdue Extended Campus offers an annual mail-in or online self-study lesson subscription for $75 (six specific lessons worth 2 points each toward CRCST re-certification of 12 CE). Call 800.830.0269 for details. For More Information: IAHCSMM provides online grading service for any of the Lesson Plan varieties. Purdue University provides grading services solely for CRCST and CIS lessons. Direct any questions about online grading to IAHCSMM at 312.440.0078. Questions about written grading are answered by Purdue University at 800.830.0269.

CRCST Self-Study Lesson Plan OBJECTIVE 2: PREPARING THE ULTRASONIC UNIT FOR CLEANING Sonic cleaners may have one or more chambers. A single-chamber unit may be a clean-only model or it may clean, rinse and dry in the single chamber. Multiplechamber units may have two or three separate chambers, with each function performed in a specific chamber. The process for preparing single- or multiplechamber units for use is essentially the same. It is essential to follow the manufacturer s Instructions for Use (IFU) to properly prepare the equipment. The following steps must be performed prior to using an ultrasonic unit: Check the cleaner and power cord for damage before each use. If damage is noted, remove the unit from service until appropriate repairs can be completed. Check the detergent level and ensure there is enough detergent available for the entire shift. Detergents should be approved for use in a sonic cleaner and should also be low foaming, free rinsing, nontoxic, nonabrasive and, preferably, biodegradable. Thoroughly clean, disinfect, rinse and dry the chamber(s) at least daily. Chamber maintenance should be performed more frequently, depending on the level of contaminates on instruments and/or if the cleaning solution is soiled. Heavily- soiled solutions may inhibit the effectiveness of the ultrasonic cleaning process, which will require the solution to be changed more frequently (including after every use). Fill the chamber with water and the approved cleaning chemical. If the chemical must be added manually, be sure the appropriate amount of cleaning chemical is used (mixing too much or too little will interfere with the cleaning process). De-gas the sonic unit. Place an approved and empty wire mesh basket inside the chamber and run the cycle per the manufacturer s IFU. De-gassing removes air and gasses from the solution that will interfere with the cleaning process. De-gassing should be performed each time the solution is changed. Note: Newer models of ultrasonic cleaners may automatically de-gas the solution. Following degassing the equipment is ready for use. The cleaning solution should be checked after each cycle. If debris is noticed, the chamber should be completely drained, cleaned, refilled and de-gassed prior to subsequent use. Test sonic effectiveness. Testing equipment effectiveness is required weekly, but, preferably, daily. There are several commercial products available for testing sonic cleaners that test the cavitation and unit s cleaning ability. Be sure to place all testing material in the sonic in accordance with IFU. All test results should be carefully documented. Any failed tests should be reported immediately and the equipment should be removed from service until appropriate repairs can be made. OBJECTIVE 3: PREPARING INSTRUMENTS FOR ULTRASONIC CLEANING When using a sonic cleaner, proper precleaning and positioning of instruments is important for effective cleaning. For manual cleaning, the following steps should be followed: Loosen screw and wing nuts, or disassemble instruments in accordance with IFU before cleaning. Soiled instruments should be rinsed using cool water to remove gross debris and prevent coagulation of protein on the instruments. Carefully manually clean the Figure 1: Improperly loaded tray instruments in accordance with IFU. All lumens should be carefully brushed and flushed. Inappropriately-cleaned instruments will interfere with the cavitation process. Rinse and inspect instrumentation for debris. When arranging cleaned instruments for sonic cleaning, the following steps should be followed: Place manually-cleaned instruments inside an approved wire mesh tray. Separate different metals (mixing of some metals will transfer ions that can cause pitting and etching). Place hinged instruments in a fully open position. Cannulated/lumened instrumentation should be primed (completely filled with sonic solution) and placed in the

CRCST SELF-STUDY LESSON PLAN horizontal position as the tray is place inside the chamber. Avoid overcrowding instruments in the mesh tray (adequate space is necessary for solution circulation). Figure 1 shows instruments that are crowded in a tray, not allowing for proper solution irrigation. Place one loaded instrument tray into the ultrasonic cleaner. Note: Trays should never be stacked.» Multi-level trays should be separated before placing inside the sonic chamber.» Tray lids should be removed and placed into the sonic chamber, in accordance with the IFU. Check the instrument manufacturer s IFU for the appropriate cycle time. Rinse and inspect instruments» If the sonic unit does not have an automatic rinse cycle, remove the instrument tray and thoroughly rinse items with treated water. Rinsing is important to remove dislodged particles and residual detergent. Note: All instruments should be rinsed prior to placing them in a washer-disinfector.» Inspect all instruments for blood and bioburden. If instruments are soiled, repeat the entire cleaning process, beginning with manual cleaning.» Inspect instruments to ensure all screws, springs, wing nuts and washers are present. If any are missing, carefully check the bottom of the sonic cleaner for the missing items. Figure 2: Testing irrigation hose Figure 3: Damaged chest retractor Note: If using an irrigating sonic unit, it is essential to ensure the instruments are connected properly, in accordance with IFU. Check to ensure the irrigation tubing is not clogged prior to connecting the instruments.

CRCST Self-Study Lesson Plan Figure 2 shows the proper water flow through an irrigation hose. Although ultrasonic units are effective for many medical devices, they do have some restrictions. The following should not be subjected to ultrasonic cleaning: Heat- or moisture-sensitive instruments; Some delicate and intricate instruments, including endoscopic or rigid scopes, vaginal or TEE probes, cameras, most power instrumentation, cords and batteries; Plated instrumentation, such as those that are ebonized or chrome plated (See Figure 3); and Cork, wood, rubber, lenses, glass and most needles. A note about sonic cleaning eye instruments: Toxic Anterior Segment Syndrome (TASS) is an inflammatory response in the eye following surgery. TASS can be caused by debris or chemical residuals on instrumentation. Because TASS can lead to severe visual impairments, special cleaning recommendations have been developed. Sonic cleaners dedicated to the processing of eye instruments should be placed in a separate area, away from general instrumentation cleaning, and dedicated to the processing of eye instrumentation cleaning. The sonic should be emptied, cleaned, disinfected, rinsed and dried at least daily, but, preferably, after each use. the lid opens and the tray falls. Do not place hands into the unit while it is in operation. Do not use if cords are nicked or damaged in any way CONCLUSION Ultrasonic cleaners are effective tools to assist with the cleaning of some of today s complex instrumentation. It is critical that Central Service technicians understand the processes involved with using a sonic cleaner. They must carefully and consistently follow all manufacturers IFU for the proper cleaning, preparation, placement, solution use and cycle times. Doing so will help ensure the ultrasonic cleaning unit operates efficiently and effectively, and produces a clean instrument. RESOURCES Association of perioperative Registered Nurses. Guidelines for Perioperative Practice. Guideline: Instrument Cleaning. 2016. Association for the Advancement of Medical Instrumentation. ANSI/AAMI ST79, Comprehensive guide to steam sterilization and sterility assurance in healthcare facilities. 2013, Sections: 3.3.7.1, 3.3.7.2, Annex N. IAHCSMM ACKNOWLEDGES THE FOLLOWING CS PROFESSIONALS FOR THEIR ASSISTANCE IN THE CRCST LESSON PLAN SERIES Damien Berg, CRCST Nicholas Schmitz Susan Klacik, ACE, FCS, CHL, CIS, CRCST Anna Clarkson, CHL, CIS, CRCST Don Williams, CHL, CIS, CRCST Gwendolyn Byrd, CHL, CIS, CRCST Deborah Bunn, ACE, CHL, CIS, CRCST Mattie Castro, CHL, CHMMC, CIS, CRCST Michelle Clark Christina Poston, CHL, CIS, CRCST Donna Serra, CHL, CRCST OBJECTIVE 4: SAFETY MEASURES THAT APPLY TO SONIC CLEANING When using a sonic cleaner, the following basic safety measures must be followed: Do not use the sonic cleaning unit until properly trained to do so. Keep the lid closed during operation to protect against aerosols and splashing. Never place anything on the lid. The lid can become damaged by the tray weight, or instrumentation may be damaged if WANT TO BE AN AUTHOR? IAHCSMM is seeking volunteers to write or contribute information for our CRCST Self-Study Lessons. Doing so is a great way to contribute to your own professional development, to your Association, and to your Central Service department peers. IAHCSMM will provide guidelines and help you with the lesson to ensure it will be an enjoyable process. For more information, please contact Natalie Lind (natalie@iahcsmm.org).

CRCST Self-Study Lesson Plan Quiz - Basics of Ultrasonic Cleaning Lesson No. CRCST 153 (Technical Continuing Education - TCE) Lesson expires March 2020 Sponsored by: OBJECTIVE 1 1. Ultrasonic cleaners are used to clean: a. Box locks b. Serrations c. Difficult-to-clean instruments 2. Ultrasonic cleaners were designed specifically for the healthcare industry. 3. Ultrasonic cleaners clean by a process called: a. Impingement b. Explosion c. Cavitation 4. During ultrasonic cleaning, gas bubbles are created that grow and implode, which pulls the soil away from the instrument. 5. When instruments are properly manually cleaned, sonic cleaners will disinfect instruments during the cleaning process. OBJECTIVE 2 6. Before using a sonic cleaner, the entire unit and power cord should be checked for damage. 7. All sonic cleaners have two or three chambers. 8. The detergents used in an ultrasonic cleaner should be: a. Maintained at 150 F b. Abrasive c. Low foaming 9. Sonic cleaners should be cleaned and disinfected at least daily. 10. De-gassing should be performed: a. Daily b. After every cycle c. Each time the solution is changed OBJECTIVE 3 11. When using an ultrasonic cleaner, instruments do not need to be precleaned before being placed into the sonic. 12. Cannulated instruments: a. Need no preparation prior to sonic cleaning b. Should be placed in the vertical position in the chamber c. Should be primed and placed in a horizontal position in the chamber d. Cannot be cleaned in an ultrasonic cleaning unit 13. When placing items in a sonic cleaner: a. They should be placed in an approved wire mesh basket b. Hinged instruments should be in the open position c. Multi-level trays should be separated 14. Ultrasonic cleaners used for cleaning of eye instruments should be placed in a separate area, away from the general instrument cleaning area. OBJECTIVE 4 15. Safety measures for using an ultrasonic cleaner include: a. Keeping the lid closed during operation b. Only using the sonic cleaner after proper training c. Not placing items on the sonic lid REQUEST FOR ONLINE SCORING (payment and scoring made directly online at www.iahcsmm.org) REQUEST FOR PAPER/PENCIL SCORING (please print or type information below) m I have enclosed the scoring fee of $15. (please make checks payable to Purdue University. We regret that no refunds can Name be given) m Check here if you have a change of address Mailing Address (be sure to include apartment numbers or post office boxes) m Check here if you wish to have your results emailed to you DETACH QUIZ, FOLD AND RETURN TO: Purdue University PEC Business Office Stewart Center, Room 110 128 Memorial Mall West Lafayette, Ind. 47907-2034 800.830.0269 City State Zip Code ( ) Daytime telephone IAHCSMM Membership Number Email Address If your name has changed in the last 12 months, please provide your former name. Purdue University is an equal access/equal opportunity institution.