UV - Monitor UVT 16. Use. Description

Similar documents
Operating Manual UV Monitor UVT 18

ZSC100 Gas Detection and Alarm System Controller

ZED UV Monitor PRO11DPI-I

THX-DL Data Logger USER & INSTALLATION MANUAL V

User manual. KNXgal. version

CSP-204 CSP-208 CSP-104 CSP-108

REPEATER FS5200R INSTRUCTION MANUAL

Operating Manual VMD420

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Two-Channel Gas Controller

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

User Manual. Dryer Controller M720

BSR Addressable Fire Detection control panel. Installation operation manual

1.7. Insulation fault evaluators EDS460/490 EDS461/491

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

QA16 Addressable System

Dryer Controller M720

Fire Control Panel FS5100

Danfoss gas detection units

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Remote alarm indicator and test combination MK2430

SCHMIDT LED Measured Value Display MD Instructions for Use

Oxygen (O2) Single-Point Gas Detection System

PolyGard 2-channel Gas Controller MGC-03

SUPERINTEND VRE-08/16/32/64

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Insulation fault evaluator EDS460-DG

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Monitoring Devices 11/1

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Introduction. OM-THA2

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

On the job around the clock 24/7: Fire detection systems

Fire Control Panel FS4000

The EN54 Part 2 & 4 Fire System

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional

Line Isolation Monitor (LIM) LIM2000plus

FLOW CONTROLLER TYPE S/601

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

The MCD-111 AUTOKLAW Microprocessor Controller Version 1.00 User s Manual

Danfoss gas detection units

Fire control panel detect 3004 plus and accessories

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

VAP304 PRO INSTALLATION & OPERATION MANUAL

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Parameterisable compact fault annunciator with permanent display

DIGITAL TEMPERATURE RELAY TR-100

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

stationary dose rate measuring systems

Products no longer available

CONTROLS INSTRUCTIONS MANUAL ENGLISH

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Independent Zone Control (I.Z.C.)

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Building Technologies. FDUL221 en Line tester operating instructions for electricians

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

IGNIS 1520M AUTOMATIC FIRE EXTINGUISHING SYSTEM CONTROLLER

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Multi-Gas-Controller MGC2

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

M1000 Alarm Annunciator

NA G µair CONNECT 2

Danfoss gas detection unit Type GD Heavy Duty

SMP 19160, SMP 29160

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

Carbon Monoxide Transmitter

CBI-064. User Manual. Caddx to KNX-BUS Interface

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

MCS 4000 Control Panel

MLHG6 / MLHG6-AU. Iso-Gard Line Isolation & Overload Monitor (LIOM) and Line Isolation Monitor (LIM) Installation and Reference Guide DANGER

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

HydroACT 600 OPERATIONS MANUAL. Analyzer, Controller, Transmitter

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

GLD-30 Gas Leak Detector

Operating Manual RCM420

Transcription:

UV - Monitor UVT 16 Use The UVT 16 Monitor is used to monitor signals from UV probes or sensors applied to sources of radiation, providing a control system for small items of UV equipment. Description The monitor is designed for installation on a control panel. There is a connection plate on the rear of the device for all the necessary connections. The front plate contains the five keypads used in operating the apparatus, three status LEDs and a two-line alphanumeric display screen from which metered values and other information can be read. The readings to be shown can be pre-selected from the menu and/or called up by pressing the keypads. These pads are also used to make the settings and to program the functions of the monitor. It is no longer necessary to have the additional complication of an add-on computer for the programming, required with the earlier monitor. All the functions of the previous model are essentially the same as those of the predecessor, so that the old version can be replaced with the new one, which offers the following improvements: Two-line alphanumeric display screen, making it easier to read off the various circuit situations and use them for evaluation. The display is illuminated when in active use. Both operation and programming make use of the keys on the front panel. There is no need to attach a computer. Costs are saved, as service personnel do not need to be equipped with laptops. Unauthorised users can be excluded from operation and/or programming. There is a two-level password system to give access (1) to those operating the plant (partial access) and (2) to the plant manufacturer s service engineers (full access). Compatible with all conventional sensors, without requiring modification. Option available of additional sensor for rate of flow Calibration against the sensor reading simple to carry out in menu without any tools Transparent, modular programming that can be adapted to customer requirements Installation depth has been reduced IP65 protection integral, no need for additional shield Additional functions available on request: internal memory to log events, possibility of attaching extra sensors (e.g. for temperature, conductivity and ph), programming of a RS232 interface according customer requests

Technical data Supply voltage Size W x H x D Measurements for installation Connections Display Operation Temperature Weight Inputs Outputs Additional functions All rights reserved in respect of technical amendments 230 V AC 50 to 60 Hz; power taken up 2,5 W (110 V on request) Casing for installation into control panel 96 x 96 x 64 Installed depth incl. clips 75 mm Area of cut-out 92 0.8 x 92 0.8 acc. to DIN 43700 Installation method: screw-down clips Two 14-pole push-on connections with screws to fix Suitable wiring: 0.25 to 1.5 mm 2 cross-section Three status LED and alphanumeric two-line LCD display, with press-button illumination LED thresholds: green > 70 %, yellow 70 % to 50 %, red < 50 %. Figures possible to display on LCD: UV level, alarm, rate of flow, lamp life (in hours), overall operating hours, no. of switch-on cycles, software version (All factory settings can be reset) By means of 5 keypads on front of device Ambient temperature 0 to 40 C Approx. 400 g - UV input via diode (can be set in two stages internally) - Input for current loop sensors 4 to 20 ma, internal apparent ohmic resistance 100 Ω - Input for UV sensor with voltage output options: max. 10 V; Ri = 50 KΩ max. 5 V; Ri = 25 KΩ max. 2 V; Ri = 10 KΩ - Input for switch-on cycles: without potential, for (mains) 230 V AC signal - Input, lamp failure (e.g. electronic ballast relay contact) Ie = 5 ma - Input, alarm off switch or button; alarm blocked during servicing or maintenance - Output, 4 to 20 ma, can be set or calibrated using menu, apparent ohmic resistance 100 Ω - Supply voltage for voltage and current sensors: (output voltage 24 V DC, will take max. 60 ma) - Early warning, relay contact - closer - Main alarm, changeover relay contact, contact will take I min = 50 ma at 5 V DC, I max = 5 A at 250 V AC, resistive load - RS 232 output on request Integral meters for: Overall operating hours (no reset possible) No. of operating hours left for lamp (reset by operator possible) No. of switch-on cycles (reset by operator possible) Change lamp display Lamp failure display Alarm or Early Warning display. Login of events possible on request Other languages on request

Connections 1/2: Input mains electricity 230 V AC 3/4/5: Output alarm 1 (changeover contact): main alarm will take (current) at (resistance) I min = 50 ma at 5 V DC, I max = 5 A at 250 V AC 6/7: Output alarm 2 (closer): pre alarm Threshold can be set from menu Contact resistance levels as for main alarm 8/9: Input alarm off When the switch/contact is closed, all alarm signals are blocked 8/10: Input lamp failure : provided for connection of the electronic ballast contacts with no potential the lamp failure alarm is triggered on closure (I e = 5 ma) 11/12: Input switch-on cycles input with no potential for a 230 V AC signal (i.e. lamp supply voltage): the internal cycle meter goes up by 1 each time this voltage is switched on. The hours of operation are metered continuously while the 230 V AC signal is being received. If the monitor is switched on simultaneously with the lamps, and there is no separate electricity supply for lamps and monitor, this input must be provided with mains voltage from contactt nos. 1/2. 13/14: Output, supply voltage for voltage and current sensors: for hardware 2.1 and higher, 13 (-) already connected internally to ground 21/26 15/16/17: RS 232 interface: this is for factory programming and can be programmed on request as an optional extra 18/21: Output, 0/4 to 20 ma: for transmission of a standardised value over a considerable distance to an external, higher-level control system (PLC) 19/20: Inputs, 0/4 to 20 ma: temperature (as optional extra) available for additional sensors, e.g. sensors to measure flow rate or 21/26: Input Ground, equal to 26, internally connected to 13 22/23/24: Input for UV sensors with voltage output (DVGW/ÖNORM standard). Supply voltage for these sensors is at output 13/14 25: Input for UV sensors with 0/4 to 20 ma current output (DVGW/ÖNORM) 26: Input Ground, equal to 26, internally connected to 13 27/28: Input for as many UV diodes as required; 2 sensitivity levels can be set by means of an internal jumper the factory setting is the high level, suitable for UV sensors based on silicon carbide, and if the sensor is based on gallium phosphide or silicon the jumper setting must be changed; there is a menu for calibration to match the lamp 28.07.2011 technical changes reserved BA UVT16 Hardware V2.1 Software V1.3 DE english

Assembly and commissioning The monitor is designed to fit in an opening of 92 0.8 x 92 0.8 mm (W x H) on a control panel. The depth to be provided for installation is approx. 75 mm including that for the cable connections. Screw-down clips are supplied with the monitor to fix it. Please attach the clips top and bottom on the housing. To make the connections sure against mix up they have different colours (right-orange, left-black). The electricity supply, relay outputs and sensor are all connected up by plugs secured with screws and marked as appropriate. Care is necessary with the polarity for the connection of the sensor. Care should be taken to avoid short circuits, especially of the sensor supply voltage. Input and output details UV diodes and measured values given in % UV diodes are connected to the terminals 27 (cathode) and 28 (anode). The factory setting is for use of silicon carbide-based sensors (SUV 13A1C). If sensors based on silicon or gallium phosphite are to be used, the jumper should be adjusted by the manufacturer. If the customer does this, the method is as follows. Disconnect the device from the mains! Remove both the 14- pole push-in terminals. Unscrew the four screws on the rear plate. Change the setting of the jumper indicated from centre/top to centre/bottom. Then be sure to close the casing before reconnecting to the main. Sensor with voltage output, for W/m² metering, or dosing (optional extra) Sensors with voltage output (SUV 20.x x Y1C) are connected as follows. The wires for the mains electricity are connected to terminals 13 (-) and 14 (). The sensor output must be connected to terminal 24 (2V) and 26 (GND). If other sensors are used or the sensor at this input is overloaded, terminals 23 (5V) or 22 (10V) can be employed. Sensor with current output, metering in W/m² Sensors with current loops (SUV 20.x x Y1C) are connected as follows. U B from the sensor have to be connected to terminal 14 (), sensor output I OUT to terminal 25 (20 or 19 also possible). Connection 13 (-) with 26 (GND) to close the current loop is already done internally. sensor contacts diode Y1 voltage output Y2 current output cable Z1 cable Z3 pin 1 cathode (27) signal output (23 resp. 24) UB (14) brown yellow pin 2 cathode (27) GND (26 resp. 21) UB (14) white brown pin 3 anode (28) - UB (13) I out (25) blue green pin 4 anode (28) UB (14) I out (25) black white You can see in brackets the terminal numbers of the UVT16.

Including other sensors The present software version supports only an additional sensor for rate of flow. The rate can be shown additionally at the display. There is a choice of which input to use for it. Inputs are the ones 19/21 (I in2 ) and 20/21 (I in1 ) specifically intended for it. If U in (or I in ) is not being used for a UV sensor, it can be used as an alternative. Upgraded systems (on customer request) envisage the use of additional sensors with a 0/4-20 ma output. If both a flow rate sensor and also an UV-sensor were connected, it would be possible to meter the dosing and carry out further related calculations. Other features which can potentially be displayed are the temperature (of either the water or the lamp), the conductivity and the ph. Displays, Operation, Programming Using the keypads, navigating through the menus Before monitoring starts, the apparatus must be adjusted to the particular external switching circumstances. All values are easy to set using the five keypads provided of the front of the device. Each time the keys are touched, the display will be illuminated for about one minute. This makes no difference to the functioning of the keys. Basic functions Arrow to right EITHER moves cursor one place to the right OR diverts into sub-menu Arrow to left EITHER moves cursor one place to the left OR diverts back to the higher-level menu without saving the value (effectively cancelling last entry) if there is no option (or cursor for options) on extreme left Central keypad (Enter) Confirms, or accepts option, or accepts diversion into sub-menu Arrow up EITHER select option OR raise number at cursor position by one respectively shift comma one position right Arrow down EITHER select option OR reduce number at cursor position by one respectively shift comma one position right before an entry indicates that it is possible to divert into a sub-menu before an entry indicates that the next function is a choice of options (Only in the Info Details menu, when the items in the basic display are selected) before an entry indicates that this item has been selected for the basic display. before an entry indicates that this item has not been selected for the basic display. To change these round, press the or keypads.

Brief guide to navigating From the basic display, pressing brings up the first level of menus. If a password check has been activated, the password will be requested. By pressing /, the user can browse through the menus, up / down, or can change the figure at the cursor position respectively shift of the comma right / left. The (Enter) key is pressed to confirm the current entry, or to execute the current menu item, or to divert into the submenu. The key can also be used to divert into a sub-menu. Diverting will start always from the marked line1. Line 2 shows a forecast or the value, which has to be changed. Within the value the cursor can be moved right or left to reach the position to be changed. If the cursor is already at the extreme left, pressing the keypad calls up the previous menu level (effectively cancelling the current one). With pressing Enter the new entry will be stored. If no keypad has been pressed for more than one minute, the display goes back to the basic display automatically, and the light goes off. After this, if a password check has been activated, it will be necessary to re-enter the password. Entering the password A password will only be requested if the password checks in the program have been activated. The password level is selected by means of the number before the "-" when the password is being entered. 1. is the level for authorised staff limited authorisation 2. is the level for the plant engineer (unlimited access rights) The device is supplied with both levels are switched off. To activate the password system, the entry off in the Password menu must be replaced with a number between 001 and 255. The relevant users should note the passwords well. If a password is forgotten after all, and typed in wrong, the display will show Password wrong; code: XX. XX stands for two capital letters, which can be used to look up in a table a once-only password. The manufacturer has the table to enable passwords 1 and 2 to be by-passed. password 1 password 2 authorisation for staff with level description No No no password 3 all have full access No Yes no password password 2 0 3 basic display only full access Yes No no password password 1 0 3 basic display only full access Yes Yes no password password 1 password 2 0 2 3 basic display only access to basic functions* full access * password 1can be changed but not deactivated LED-display / operating status priority status LED active relay priority status LED active relay 13 start test - 6 sensor fault! main alarm 12 alarm off (m.)! - 5 lamp fault (8/10) main alarm 11 main alarm (m.)!! main alarm 4 main alarm! main alarm 10 pre alarm (m.)!! pre alarm 3 pre alarm! pre alarm 9 internal fault ### main alarm 2 life time alarm - 8 delay ###,# - 1 overload! - 7 alarm off (8/9)! - 0 normal operation - LED on! LED flashing

Menue structure ( Menue tree) level name menue point kind of display 1 2 3 menue point req uired input b asis display menue monitor display info state display operation status operation ok % 0 8 / 5, 5 4 / 7 8 0 0 / F info UV display UV-value in or W/ m² uv 3% info rate of flow display rate of flow in m³ h flow m³ h info lamp hours display remaining lamp hours lamp.5 h info overall hours display operation hours of the monitor all 69 h info switching cycle display ON OF cycles swcy 20 info version display software version version 1.3-EN main menue menue information menue info state not yet - already chosen for asis display, change with info UV not yet - already chosen for asis display, change with info rate of flow not yet - already chosen for asis display, change with info lamp hours not yet - already chosen for asis display, change with / b info overall hours not yet - already chosen for asis display, change with info switching cycles not yet - already chosen for asis display, change with info version not yet / - already chosen for b asis display, change with / lamp menue change lamp decision yes no switching cycle overwriting no. of switching cycles possib le lamp hours overwriting no. of remaining lamp hours possib le life time lamp input/ overwriting of lamp lifetime hours possib le b b alarm mode menue automatic choose automatic function for alarm with manual alarm off all alarm will e lock ed with manual main alarm tripping main alarm with (e. g. check higher level monitoring / buzzer) manual pre alarm tripping pre alarm with (e. g. check indicator light / buzzer) b b alarm menue manual duration input duration of manual lock ed alarm (0=endless) delay input duration of alarm lock ing after lamp ignition (run-up time) pre alarm input threshold value pre alarm (%-value > main alarm value) main alarm input threshold value main alarm (%-value < pre alarm) % Y %,, J Y / sensor UV menue input choose sensor input (diode, Uin, Iin, Iin1, Iin2) calib ration value input value in (diode) or W/ m² (for sensors with option 1/Y 2) unit choose unit W/ m² (for sensors with option 1/Y 2) calib ration decision yes no (for sensor diode e. g. type SUV13C) / sensor rate of flow Menue input choose sensor input (Iin, Iin1, Iin2) calib ration value input value in m³ h (=20 ma) ( 0 / 4 % % 0 / 4 N G! output Iout) menue Iout mode choose mode - 20 ma maximum input -value for 20 ma minimum input -value for ma calib ration DO OT CHAN E (internal 20 ma calibration = St Iout on side sticker) change password input password 1 / 2-0 0 1... 25 5 (number) 0 0 0 (password function inactive) store save all inputs with (new version will store automatically) Access authorisation level: 0 = b lack ( no restriction) 1= b rown ( partial access) 2= green 3= red ( full access)

N otes: My standard values: My standard circuitry: P assword 1 ( plant user) : assword 2 ( plant manufacturer) : Miscellaneous: 28.07.2011 technical changes reserved BA UVT16 Hardware V2.1 Software V1.3 DE english