MK8000 MP1.20 OPC Server for subsystems

Similar documents
Product Datasheet MM8000 MP3.10 Management Station

Product Datasheet MM8000 MP3.15 Management Station

Building Technologies

Siemens Building Technologies Landis & Staefa Division. for central units OCI600 / OCI611 / OZW10 / OZW111 / OZW30 / OCI55

Pro-Watch Facility Manager

Fully redundant and customizable alarm, monitoring & Control system

Features and Advantages

BIS - Overview and basic package

Innovative protection that combines power and flexibility

LSM MANUAL PRINCIPLES OF LSM

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

Features. Windows management system for hazard detection systems

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Patriot Systems Limited

FC700A Fire detection control unit

Compact Product Suite Compact HMI 6.0 Overview ABB

MULTIFUNCTIONAL SYSTEM

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Eclipse Nursecall Systems Ltd. Clipper Plus & Clipper ID. Document V.2.1b (Basic) ENS. Freedom Through Technology

Design. Innovations in Integrated Control Systems

Application of OPC in the Intelligent Building System Integration

HAWK 8000 CONNECTED BUILDING MANAGEMENT

IntesisBox BACnet/IP Server - Notifier ID3000 series

For Complete Fire and Gas Solutions

Complexity made simple

TrueAlarm Fire Alarm Systems

SiPass Entro Open the door to comprehensive security

BIDDER S OFFICE FACILITIES

CCU Family of Modules

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

WEBs AX Security. Integrated Security With Simple, Web-Based Management

FT NAVVISION AMCS TYPE-APPROVED, USER-CENTERED YACHT AUTOMATION

Supervisor Standard Edition

Remote fiber testing to improve SLA s

TrueAlarm Fire Alarm Systems

Architecting a Distributed FactoryTalk View SE Application

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

Imtech Marine Free Technics. Type-approved, user-centered yacht automation

Desigo CC Building Automation and Fire Safety FAQs

Access Professional Edition. The flexible access control system that grows with your business.

HVAC Products. SAPHIR AirGo OEM Air Handling Unit Concept

BMS Specification. Lonix Ltd.

Cardax System Comparison

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

SiPass Entro open the door to comprehensive security

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

Supervisor OPERATIONS MANUAL. Heat-Tracing Controller Configuration and Monitoring Software. Versions up to 2.7xx. INSTALL-118 (Europe)

E Programmble Smoke Detector Controller. Figure 1. Programmable Smoke Detector Kit

STRIKE GUARD DELIVERS:

JOVY SYSTEMS RE User Manual Rev. 1.00

Compact HMI Overview

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Advantage Services Capabilities

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

Fire and Gas Monitoring Panel ST7-HV

General Specifications

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

C-Bus Application Note. Function Rooms and Ballrooms. Overview

PotterNet Fire & Facility Supervising Station

FC723 Fire control panel

ACCESS CONTROL SOLUTIONS ACTEC SERIES

Methods of Software Integration of Alarm Systems

Fire Alarm Network Reference

NGC-20 LOCAL CONTROL CENTRAL MONITORING

MICROPOINT to MICROPOINT II UPGRADE

Protect your investment with Safety Manager

PM-ANALYZE. Overview 1. System Configuration 2. Operation 3. Analysis of Alarms and process values. User Interface 4

Towards a Detector Control System for the ATLAS Pixeldetector

TrueAlarm Fire Alarm Systems

Patriot Systems Limited

Reference report Traffic & Transportation

Am I safe working in this building?

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Welcome to a world where technology flows through the heart of your business environment. Welcome to CDC

MobiCall-Client PC Safety at work

Safety Instrumented Fire & Gas Systems

TrueAlarm Fire Alarm Systems

AUTROSAFE 4 A new level in interactive fire detection systems

TECHNOLOGY TECHNOLOGY

VTScadaLIGHT for Small Water & Wastewater Systems

TrueAlarm Fire Alarm Systems

Advanced FireAlarm Panel 1-4Loop

AUTROSAFE. An interactive fire detection system for larger vessels

TrueAlarm Fire Alarm Systems

ID3000 intelligent. fire alarm panel

X.90 Access Control System

DALI EMERGENCY LIGHTING ...MADE EASY DALI EMERGENCY LIGHTING TAP SCREEN TO CONTINUE N-LIGHT - REF: 7294V3 04/12 POWERED BY: DALI EMERGENCY LIGHTING

NETx Voyager Visualization

SiteSentinel itouch Console

Access control. SiPass Entro. Open the door to comprehensive security. Answers for infrastructure.

Enterprise GIS Architecture Deployment Options

Scanlight Next generation dimmable addressable lighting control

Pro-Watch Software Suite. Architect and Engineering Specifications. January 9, 2002 Revision 3.4

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

ClampOn DSP Pig Detector

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Engineering Procurement Construction Management

Transcription:

MK8000 MP1.20 OPC Server for subsystems DMS The MK8000 OPC Server for subsystems provides a wide array of solutions for the centralisation and management of physical security and control systems. Founded on leading software and network technology standards, the OPC Server is designed specifically for safety, security, and building automation applications and enables complete management from a single workstation. The Siemens line of security management systems include solutions for fire, intrusion and gas detections, access control, closed circuit television monitoring, and evacuation and extinguishing sy stems. The MK8000 OPC Server for subsystems has been optimised for the management of the solutions line, and allows interoperability with systems from both our SBT Building Automation division, as well as 3 rd parties. The MK8000 OPC Server for subsystems complies with the OPC Foundation s tests and standards. 1

Background and Introduction Benefits For years, the Siemens division has been recognised for its high quality security systems. Much of our success lies in our commitment to continuously updating our products with the latest technological advances while maximising the lifetime of our customer s investment. Now, we are proud to introduce our Open System Philosophy of integrated solutions. In compliance with the OPC Foundation s tests and standards, the MK8000 OPC Server can be integrated with any OPC standard management system. If you are looking for a security solution that is complete, flexible, and scalable, it would be our pleasure to show you how the MK8000 OPC Server can help you to maximise both your security options as well as the lifetime of your system. System and software solutions specifically designed for safety, security, and building automation applications; Open System Philosophy based on up-to-date market standards: standard PC hardware, Microsoft Windows 2000 operating system; Secure and Flexible architecture allows solutions ranging from a simple single-station configuration, to complex distributed configurations; Complete scalability of all configurations, allowing need-based expansion of any system, from small and medium systems to complex and sophisticated systems; Open communication with third-party units utilising standard interfaces; Communication can be performed through local and networked connections (Network data transfer support via DCOM); Long term investment; Easy implementation and modification; Configuration with Composer, our powerful DMS8000 tool environment. Features OPC Data Access 2.0x Specification; Supports Tag browsing (IOPCBrowseServerAddressSpace); Server attempts to renew lost connections; Tag export function; MK8000 test client included; OPC interface inspection utility included; Free 2h Demo mode 2

Typical Architecture A typical system configuration for medium-size systems is shown below Management level Configurations Single-Station Configuration Single workstation that contains all software levels (Client and Server); The station communicates with the communication level using local ports (typically EIA/TIA-232); A straightforward solution for small and medium-size systems. 3

Client/Server Standard Configuration Distributed client and server communicate via TCP/IP connection; The Server station connects with the communication level via local ports (typically EIA/TIA-232); A straightforward solution for small and medium-size systems. Distributed Configuration Software architecture distributed on different hardware; Each station specialised for a single function: the Server provides OPC functionality, while the Communication Front Ends provide background functionality; The highest performance solutions for large systems that require both multiple Communication Front Ends, and coordinated management. 4

Connectivity Communication with locally distributed field units can be performed using: Cerloop redundant rings; CDI-net star topology; CDI-WAN network (configuration with serial line) Control level Configurations Control Panels Supported Configuration Example Siemens CS11 AlgoRex (EP5) fire detection systems Siemens CS11 AlgoRex (EP7F) fire detection systems Siemens CZ10 fire detection systems Siemens CC60 gas detection systems Siemens CS4 intrusion detection systems Siemens CS440 intrusion detection systems Siemens CZ12 intrusion detection systems Siemens CS6 MP3 Guarto intrusion detection systems Siemens STT11 système de télécommande et télésignalisation Siemens MF7033 digital PLC unit See the following configuration example for a system connected to both Cerloop and CDI-net. For details regarding supported configurations, please refer to the Application & Planning Manual. 5

Software Architecture The OPC Server for subsystems is designed using a software architecture optimised for freedom and flexibility. The key features are: Structured architecture with a well-defined layer interface; Real Client/Server Configuration; Fully Modular; Object Oriented. System Requirements Hardware Requirements Pentium III or higher 400Mhz, 128 MB or higher Hard disk space 100 MB free CD-ROM or DVD COM Port 1 (2-3 optional) LPT Port 1 LAN Connections 100Mbit/s recommended Keyboard and pointing device Standard keyboard; mouse or trackball SW protection Key provided by SBT USB / parallel Operating System Microsoft Windows 2000 server SP3 or later Technical Characteristics Limitations Subsystem Max. 64 Data Points Max. 20000 OPC clients 4 Serial connections - standard 3 Serial connections - distributed 9 Subsystem Supported CS11 (EP5) CS11 (EP7F) CZ10 CC60 CS4 CS440 CZ12 STT11 MF7033 Cerloop configuration via MK7022 Direct RS-232/ ISO1745 configuration CDI-net configuration Cerloop configuration via MK7022 CDI-net configuration CS6 MP3 CDI-WAN configuration via NK8223 serial link (1 CS6 per NK8223; CS6 connected via LON Bus to NK8223) 6

Details for ordering Type Size Remarks SW license for OPC Server MK8000 xxxx Size can vary from 100 to 20000 - see price list SW license for Cerloop Driver NS8010 x Size can vary from 1 to 3 - see price list SW license for CDI-net Driver NS8012 x Size can vary from 1 to 3 - see price list 7

AG Alte Landstr. 411 CH-8708 Männedorf Tel. +41 1-922 6111 Fax +41 1-922 6450 www.sibt.com 2003 Copyright by AG Data and design subject to change without notice. Supply subject to availability. Document no. 004968_c_en_-- MK8000 Sales Material Edition 07.2003 Section 2