Pump - Turbine Specifications

Similar documents
DELOMATIC 400, DM-400 HYDRO

Generator Paralleling Controller, GPC-3 Hydro Start and stop sequences, water level control

A study of Transient Performance of A Cascade Heat Pump System

Impact of TXV and Compressor in the Stability of a High-End Computer Refrigeration System

Selection and Operational Considerations. Harold Streicher, Vice President Sales Hansen Technologies, Inc.

1900 Series In-Line Pump

Homework Chapter2. Homework Chapter3

Design And Analysis Of Centrifugal Pump

Manhardt Lindel / ERHARD-Armaturen VALVE & PIPELINE CAVITATION

SSRG International Journal of Thermal Engineering (SSRG-IJTE) volume 1 Issue1 Jan to April 2015

Water engineers and utilities are often

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Autodesk Moldflow Insight AMI Molding Window Analysis

and Sprinkler System in Resalat Tunnel of Tehran

FINAL COVER VENEER STABILITY ANALYSES FOR SCA DESIGN

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Development of Large Size Hybrid Fan

Stock Vessels for Improved Quality and Energy Savings

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers

Monitoring Pump Performance with Vibration. Mitchell Stansloski, PhD, PE

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

ADVANCED MONITORING AND DIAGNOSTIC SYSTEMS FOR INDUSTRIAL GAS TURBINES

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps

COMPACTION TECHNOLOGY

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Australian Journal of Basic and Applied Sciences

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark

GFD. GVD V-shape coil condenser. Güntner Info. 8 additional basic models for container transport!w. V-shape coil drycooler

Twin City Fan & Blower

,Chaojian He6, f. School of Guangxi University, Nanning , China.

Ducted Propeller. Airflow Volume

Effects of Splitter Blades on Centrifugal Pump Performance - A Review

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

Geology and Soil Mechanics Prof. P. Ghosh Department of Civil Engineering Indian Institute of Technology Kanpur Lecture - 12 Soil Compaction- B

HYDROGEN DETECTION INSTRUMENTATION FOR THE SIAC HYDROGEN RECOMBINERS. Summary

Irrigation Water Pumps

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Submerged Pumps and Expanders with Magnetic Coupling for Hazardous Applications

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Aromatics and Oxygenates in Gasoline June2018

Installation instructions for Plenum-mounted add-on electric heaters

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

ISO/TS TECHNICAL SPECIFICATION

Rich Knoelke. Questions or Comments: Mulcahy Shaw Water.

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

TRANSIENT MODELING OF HYBRID LOOP HEAT PIPE SYSTEMS WITH MULTIPLE EVAPORATORS

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Rotodynamic Pumps INTRODUCTION:

SECTION STEAM CONDENSATE PUMPS

E-16 Main Engine Remote Control System

INTERNATIONAL STANDARD

How to Cut Chiller Energy Costs by 30%

KV Vertical Inline Pumps Taco Vertical Inline Pumps meet the latest standards for hydraulic performance and dimensional

The IEC Certification Process. Introduction to Windflow

On-chip optical detectors in Standard CMOS SOI

Refining and Petrochemical Heater trouble shooting

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

A Modeling Study on the Operational Stability of a Variable Speed Direct Expansion Air Conditioning System

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

PumpLab TM Operator s Manual

Global Journal of Engineering Science and Research Management

prestige Control Application Supplement - ACVMax

Commissioning of a 1 MWe Supercritical CO 2 Test Loop

Pumps CEU 259. Continuing Education from the American Society of Plumbing Engineers. May ASPE.ORG/ReadLearnEarn

Modelling Of An Automotive Multi-Evaporator Air-Conditioning System

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Fans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong

Control Application. Supplement - ACVMax

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

Hebei Datang International Wangtan Power Company, China

Reinforcement with Geosynthetics

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Water Pumps. turbo-hydraulic pumps, positive-displacement pumps.

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

/ sicam SICAM Safety Full functionality for safety-critical applications Answers for infrastructure and cities.

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

EHPA Testing Regulation

2. HEAT EXCHANGERS MESA

COST REDUCTION OF SECTION CHANNEL BY VALUE ENGINEERING

INTERNATIONAL STANDARD

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Available online at ScienceDirect. Physics Procedia 67 (2015 )

COMPANY MANAGEMENT TREE

PEMP RMD M.S. Ramaiah School of Advanced Studies

AXIAL & JET FANS FOR TUNNEL VENTILATION

Centrifugal and Positive Displacement Pumps for Hygienic Applications

Keywords: slope stability, numerical analysis, rainfall, infiltration. Yu. Ando 1, Kentaro. Suda 2, Shinji. Konishi 3 and Hirokazu.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Scientific-Research Institute of Metallurgical Heat Engineering OJSC VNIIMT

Transcription:

Fig 1 Bajina Basta storage and dam. This storage is the lower reservoir for Bajina Basta pumped storage plant. The roof and the crane on it is at the bottom of the tailrace. Pump - Turbine Specifications Type: Vertical shaft, single stage, single runner, Francis pump-turbine Turbine: Head: 497-600 m Rated head: 554 m Output: 243-315 MW Rated output: 249 MW

Speed: 428.6 rpm Specific speed: 73 m-kw Pump: Head: 532-621 m Discharge: 37-51 m 3 /s Speed: 428.6 rpm Specific speed: 27 m- m 3 /s Other data: Runaway speed: 659 rpm Transient speed rise after full load rejection: 45% Maximal penstock pressure: 900 m Submergence: 54 m Mechanical Design As a part time designing and consulting engineer at "Energoprojet", Belgrade Prof. S Pejovic had done mechanical design of "Bajina Basta" pumped storage power station. Model Tests The pump-turbines in Bajina Basta pumped storage operate with the head exceeding 600 m. This was the record high head. The series of model tests had been performed to verify the hydraulic characteristics. The figure shows the model test setup (TOSHIBA REVIW). Four quadrant characteristics had so called unstable "S" form. The first explanation of the "S" form instability phenomena was published by Pejovic et al. Link: IAHR 1976 Leningrad S form characteristics.pdf

Fig 2 Model test setup at TGOSHIBS laboratory Transient Analyses Transient computer analyses had been based on four quadrant model test characteristics. For the firs time the "S" form instability had been discovered by computer simulations as Fig 3 suggested. The peaks of pressure fluctuations exceeded the 900 m design penstock pressure head. The philosophy of the governing and protective system had been changed to prevent a parallel runaway of the both units at full flow. The problem was solved if all protective devices properly responded in all critical transients. If not, pressure transient peaks would exceed the design limit of 900 m pressure head. Water column separation and Reverse waterhammer The draft tube water column separation had been analysed at the design phase. At my demand the manufacturer analysed and confirmed that pump-turbines submergence of 54 m would protect system from cavitation and water column separation in all pump, turbine and transients mode of operations. In 2008, about 30 years later, editing and updating the second edition of the Guide to Hydropower Mechanical Design, ASME HPTC (American Society of Mechanical Engineering Hydro Power Technical Committee), HCI Publications 1996 the water column separation in the Bajina Basta drat tubes has been noticed in the diagrams (Fig. 3 and 4). The calculated pressure in the draft tube was below the zero pressure; therefore dangerous water column separation could occur followed by severe rejoining in the draft tube and runner. To prevent a runaway, particularly the simultaneously runaway, the closing devices of the both pump-turbines, wicket gates and penstock valves are closing atomically by the control system. It is highly improbable the all four closing devices to fail to close but a careful maintenance must keep them operable at any and all the time.

Fig 3 Two units runaway; guide vanes and inlet penstock valves are open; both pump-turbines run at full runaway; calculated zero pressure in the turbine draft tubes means water column separation The water column separation in runaway has not been noticed by the team of engineers, I was the member of, and was not indicated by manufacturers and other experts involved in the design and construction of the Bajina Basta pumped storage plant. Later on additional analysis of the field test results depicted in Fig 4 shows the pressure jump for 4 bar up to 10 bar in the draft tube in the case of one turbine load rejection.

Fig. 4 Transient Calculations versus Field Test Results. Low specific speed unstable S form pump-turbine four-quadrant curves is the source of severe transients even at one unit load rejection while other unit continues normal operation. Quick change of flow from turbine to pump direction results in sudden pressure jump and drop. Water column separation occurred in the draft tube and pressure jumped up to 10 bar when separated water columns rejoined. Recommendation: Each low specific speed pump-turbine should have its own penstock and tailrace. The data is from Bajina Basta pumped storage plant. Pump-Turbines for Bajina Basta The World wide five best companies had been carefully analyzed as potential manufacturers for Bajina Basta pump-turbines. Two of them had been selected for model tests. TOSHIBA's units are in operation. Hydraulic Vibration and Stability Analyses Hydraulic vibration and stability had been analyzed in frequency domain. In the "S" zone of four quadrant machine characteristics, system is unstable. Both wicket gates and

penstock valves are constructed to prevent runaway in this dangerous unstable transient operating points. Self Excited Vibrations Self excited vibrations had been analyzed. System designed to prevent them. Site Measurements Measured data of transient regimes ware compared with the theoretical computer simulations. Agreement was good. Measured machine properties confirmed the quality of the units in operation. Back to Back Start in Pumping Mode of Operation Vibrations of Turbine Units of Hydro Power Plant "Bajina Basta" during Back to Back Start in Pumping Mode of Operation the Pump-Turbines of Pumped Storage Power Plant "Bajina Basta" were analyzed in order to reduce excessive amplitudes of bearing displacement. Bajina Basta Cross-section

Photo Bajina Basta Power Plant (4x90 MW) and Pumped Storage Power Station Bajina Basta (2X300 MW)

Papers, Studies, Analyses, Troubleshooting, Simulations <See my CV> Back to <Home Page> click here.