Alfa Laval Potentiometric Level Transmitter

Similar documents
Alfa Laval Level Switch

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum

Instruction manual. Alfa Laval Rotacheck+ & Rotacheck Basic. Machines delivered with ATEX Certification in accordance with Directive 94/9/EC

Instruction Manual. Pharma-X ESE02197-EN Original manual

Instruction Manual. Pharma-line ESE02198-EN Original manual

Covering: Standard Machines Machines delivered with ATEX Certification in accordance with Directive 2014/34/EU TE91A664 First published:

Instruction Manual, Rotary Spray Heads

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Sitron s CF Line of Flow Switch Monitors

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Instruction manual ISO-MIX Skid Mounted Pump Unit

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Process Sensors. Product Overview

WIO200 Water In Oil measuring instrument

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Condumax CLS16 and CLS16D

Process Sensors. Product Overview

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Inductive Conductivity

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483

Alfa Laval Arctigo IS

FSW300 Series Flow Switch

Beck. The differential pressure transmitter for air

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Manufacturer declaration. 3-A, Installation and Cleaning Instructions. VEGAPULS 63 Hygienic process fittings. Document ID: 46197

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Hygro/hygrothermal transducers (hygrometric)

Ultrasonic Level Measurement nivopuls FDU 10 S

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Hygro/hygrothermal transducers (hygrometric)

Capacitive Sensors with a body that is in excellent shape - The 26 Series

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Flow Measurement SITRANS F C

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

for relative humidity and temperature with calibration certificates

ProSens Dust Measurement

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

providing the perfect mix

OilSET-1000 (12 VDC)

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

OEM Sensors for HVAC manufacturers Heat recovery Chiller

PA ma Loop Powered Level Preamplifier

Instruction Manual - Plate Heat Exchangers

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Models TX-KE and TX-KP Toxic Gas Transmitters

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

OPTISENS TUR 2000 Technical Datasheet

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

The A-series Eletta Flow Monitor with local indication and analog output

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Instruction Manual April sitrans AS 100

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Relative Humidity Transmitters

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Dissolved Oxygen Measurement liquisys M COM 223 / 253

RK Carbon Monoxide Transmitter Operator s Manual

Process sensors. Product overview

WM3000 WIRELESS MODULES

VD 53 - Vacuum drying oven for non-flammable solvents

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

A more complete mix. for optimizing your tank

Safety vacuum drying oven for flammable solvents

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

1592P01. for liquids in piping DN

Installation Manual. esense Duct (Disp) Figure 1 The esense Duct with and without display

RK Carbon Monoxide Transmitter Operator s Manual

Here is your conveying solution: Product group D.

IT system floor-standing distribution

TopWing Ultra-Hygienic Rotary Lobe Pumps

WIO 200B and WIOI200B Water in oil sensor

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Test Report No.: Page 2 of 14

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

CP CP

RK CO 2 Transmitter Operator s Manual

THERMASREG TR 040 THERMASREG TR 060

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Instruction Manual September 2010 SITRANS LVL200S

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

Rinse connection adapter CPR 40

Laser Distance Sensor Type M Analog-Output

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

RK-05 Combustible Gas Transmitter Operator s Manual

Transcription:

R Alfa Laval Potentiometric Level Transmitter TE67Hxxxxxxxxx Safety instructions This instrument is built and tested according to the current EU-directives and packed in technically safe condition. In order to maintain this condition and to ensure safe operation, the user must follow the hints and warnings given in this instruction. During the installation the valid national rules have to be observed. Ignoring the warnings may lead to severe personal injury or substantial damage to property. The product must be operated by trained staff. Correct and safe operation of this equipment is dependent on proper transport, storage, installation and operation. All electrical wiring must conform to local standards. In order to prevent stray electrical radiation, we recommend twisted and shielded input cables, as also to keep power supply cables separated from the input cables. The connection must be made according to the connecting diagrams. Before switching on the power supply take care that other equipment is not affected. Ensure that the supply voltage and the conditions in the environment comply with the specification of the device. Before switching off the supply voltage check the possible effects on other equipment and the processing system. 74-03 Description The Level measuring device utilises the potentiometric measurement principle and can be used in all medias that have a minimum conductivity of 50 µs/cm. From the low resistive measuring rod a high frequent current is fed through the media to the tank wall. The voltage between the tip of the rod and the tank wall is measured. This output voltage is proportional to the tank filling level. The measurement is unaffected by temperature and adhesive media. The instrument is ideal for measurements in small wessels with tough, pasty or strong adhesive media, such as ketchup, honey, and toothpaste. The integrated electronics provide a 4...20 ma output. The Alfa Laval Potentiometric Level Transmitter has automatic recognition of top/buttom mounting position. Even angled installation is possible. In a non-conductive tank such as a plastic tank a reference rod must be installed. Please observe that a non-linear conductivity in the media will affect the accuracy of the measurement. A version with separate rod sensor and electronics is available for applications where the ambient temperature at the measuring point exceeds 60 C. Due to the high temperature limit the Alfa Laval Potentiometric Level Transmitter is well suitable for CIP and SIP processes. The hygienic installation is guaranteed by using the clamp connection.

Mechanical Installation Cautions Use only the authorised special designed accessories. The product warranty is void when installed with other adapters. The sensor can not be shortened. Please be aware of the active measuring zone on the rod (see drawing) Do not use teflon, paper or other gaskets. The process connection must have electrical contact with the tank. if not, a separate grounding cable must be installed. If the tank is non-conductive an additional ground electrode must be installed. This should have electrical connection to the sensor process connection. Make sure that the rod can not touch the tank wall even with the highest movement of the media. When installed <100 mm from the tank wall the rod must be parallel with the tank wall. For larger distances non-parallelity can be allowed. After Installation and Configuration Check the leak tightness of the sleeve. Check the tightness of glands or M12 plugs. Check the tightness of the cover. Check that the rod is not touching the tank wall. Dimensional Drawings [mm] ø89 Gland 92 8 33 AF36 DN51 Clamp L Active zone ø10 5 mm integrated electronics

Electrical Installation 1 2 3 4 + - + - 18...36 Vdc 4...20 ma Push buttons >3 sec. to set 0% and 100% Push both > 3 sec. to reset. Setpoint 100%; 20 ma Setpoint 0%; 4 ma 18...36 Vdc (+) (+) 4...20 ma 1 4 2 3 4...20 ma (-) (-)18...36 Vdc 1: Brown 2: White 3: Blue 4: Black Connector LED Buttons M12 plug Operator Control The green LED indicates that a supply voltage > 18 V with the correct polarity is present. The two red LEDs show different flashing rates according to the control of the 4...20 ma output. The sensor can be installed in the top or the buttom of the tank. The sensor is calibrated for installation from the top. Then 4 ma output corresponds to the tip of the rod, and 20 ma to the thread end. When installed from the buttom of the tank an output excessive of 4 ma is obtained. The sensor can be calibrated by pressing one of the two setpoint keys for more than 3 seconds. The relevant LED will show a steady light. With these two buttons any empty/full level can be configured on the entire length of the rod. The factory setting will be valid again by pressing both keys for more than 3 seconds. The dry signal level is adjusted together with the low level setting. The dry indication is 2.4 ma output current. Caution If different medias are used the low level adjustment should be made with the media having the least conductivity. Caution The minus pole of the power supply is connected to the housing via a protective diode. However, the 4...20 ma output is galvanically isolated from the power supply. Measuring Principle Ugen 100% Uout to amplifier Theory The liquid is stored in a ground connected tank. The immersed level probe is a low resistance rod where the ends are powered by an AC generator operating in the lower kiloherz frequency range. Between the rod and the tank wall is an endless amount of high level resistances. Since they connect to the same potential (the tank wall) they can be shown as two equivalent resistances, R1 and R2 connected to an imaginary center point. A high resistance input amplifier is connected between the generator and the tank wall. X% R1 Since the generator is supplying a high range current it will create a significant voltage drop across the low resistance rod. The resistances R1 and R2 form a voltage divider in range of the immersed part of the rod. Output from this divider will indicate half the level of the liquid. The amplifier then calculate the actual level of liquid from 0 to 100%. 0% R2 The formula is: Uout= 1/2 x media level (%) x Ugen Media level (%) = Uout/Ugen x 2 The level measurement is insensitive to adhesion. Caution It is very essential that the media conductivity is homogenious. Otherwise R1 will not be equal to R2 and the output voltage will be influenced.

Mounting of 3-A Marked Products Max. ± 85 4) 5) 1) 2) 3) Max. ± 175 Installation of 3-A marked products: 1) Use only a 3-A marked counter part. 2) The inspection hole should be visible and drained. 3) Mount the instrument in a self drained position. 4) Level the inner surface of the pipe with the counter part. 5) Weldings should be grinded to Ra= 0.4 / Ra= 0.8 The 3-A mark is valid only when the product is mounted in a 3-A marked counter part and installed according to the installation manual. Use also a 3-A marked O-ring or gasket if relevant. The 3-A marked products conforms to the 3-A Sanitary Standard criteria. Materials and surfaces fulfill the FDA demands and follow the EHEDG guidelines regarding design, materials and finishing. EPDM gaskets supplied with 3-A marked products are conform to Sanitary Standard Class I (8% milk fat max.) Example of Application Alfa Laval Potentiometric Level Transmitter Output 21.6 ma 21.6...20 ma Set point 100% = 20 ma 20...4 ma Set point 0% = 4 ma 4...2.4 ma 2.4 ma

Reservation and contact infomation Note: The illustrations and specifications contained in this manual were effective at the date of printing. However, as continuous improvements are our policy, we reserve the right to alter or modify any unit specification on any product without prior notice or any obligation. How to contact Alfa Laval Tank Equipment A/S For further information please feel free to contact: Alfa Laval Tank Equipment A/S Baldershoej 19 P.O. Box 1149 2635 Ishoej Denmark Phone no.: +45 43 55 86 00 Fax no.: +45 43 55 86 01 www.alfalaval.com Contact details for all countries are continually updated on our websites. 20XX Alfa Laval Corporate AB This document and its contents is owned by Alfa Laval Corporate AB and protected by laws governing intellectual property and thereto related rights. It is the responsibility of the user of this document to comply with all applicable intellectual property laws. Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), or for any purpose, without the expressed permission of Alfa Laval Corporate AB. Alfa Laval Corporate AB will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution. Item Number Overview Potentiometric level transmitter with DN50 (ISO2852)/Clamp DN51 (DIN32676) clamp connection, acc: 0.5%, M12 electrical connection Item no. TE67H021050330 TE67H021075330 TE67H021100330 TE67H021125330 TE67H021150330 TE67H021175330 TE67H021200330 TE67H021225330 TE67H021250330 TE67H021275330 TE67H021300330 Description Sensor length: 0.50 mtr Sensor length: 0.75 mtr Sensor length: 1.00 mtr Sensor length: 1.25 mtr Sensor length: 1.50 mtr Sensor length: 1.75 mtr Sensor length: 2.00 mtr Sensor length: 2.25 mtr Sensor length: 2.50 mtr Sensor length: 2.75 mtr Sensor length: 3.00 mt

Potentiometric level transmitter with DN50 (ISO2852)/Clamp DN51 (DIN32676) clamp connection, acc:0.5%, M16 cabel gland Item no. Description TE67H021050340 Sensor length: 0.50 mtr TE67H021075340 Sensor length: 0.75 mtr TE67H021100340 Sensor length: 1.00 mtr TE67H021125340 Sensor length: 1.25 mtr TE67H021150340 Sensor length: 1.50 mtr TE67H021175340 Sensor length: 1.75 mtr TE67H021200340 Sensor length: 2.00 mtr TE67H021225340 Sensor length: 2.25 mtr TE67H021250340 Sensor length: 2.50 mtr TE67H021275330 Sensor length: 2.75 mtr TE67H021300330 Sensor length: 3.00 mt TE67H021275340 Sensor length: 2.75 mtr TE67H021300340 Sensor length: 3.00 mtr Available add-ons TE67Hxxxxxxxx2 with 3.1 Certificate TE67Hxxxxxxxx4 with 3-A Documentation 58 50-025 B1 / UK This data sheet may only be reproduced in full.