INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Similar documents
715 Portable MANUAL JUNHO 2013

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

14300 MAINS SEPARATOR ALARM MANUAL

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Door Release Power Supply

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

OPTISENS TUR 2000 Technical Datasheet

Snifter ATEX22 VERSION. User Manual. Distributor

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

LC2200 Level Controller Installation and Maintenance Instructions

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

PTE0705 Electric Fence Monitor

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

FIRERAY 5000 range USER GUIDE

SET-2000 Hi Level/Oil

ISIS SAFETY SYSTEM Installation guide

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

SET-2000 Oil/Sludge 12 VDC

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

10yr O2NE & Safe-Ox. User Manual

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT


Earth-Rite II PLUS Static Earthing System

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Smoke Vent Control Panel PCB4 V4 Installation Manual

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Instructions for the fan motor control system with integrated wiring terminals SILVER C

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

5000 INSTALLATION GUIDE

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Ax60+ Multi-Gas. Service Manual

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Operation and Maintenance Manual

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

Interface Modules for SENTRI

HYTEK ATEX APPROVED TANK ALARM

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Public Safety DAS Annunciator Panel

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual


OilSET Installation and Operating Instructions. Oil Separator Alarm Device

METEOROLOGICAL INSTRUMENTS

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

RE-PR3-E-27 3-Phase Panel Mount 27kW

MODEL WIND TRACKER

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

USER MANUAL & MAINTENANCE GUIDE OG OO

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Intelligent Security & Fire Ltd

Operating Instructions

SAFETY INFORMATION AND WARNINGS

Flostop TS D7E and A8E. Operation Manual

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Electronic Thermostat With RF

Installation & Operation

GL-CO-RFG Channel Gas Leak Alarm System

805QS Pressure Switch-Transmitter

DMFPM-2R MULTIFUNCTIONAL

PERFORMANCE SLIMMING BELT

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

Pioneer-R16 Gas Monitor Operator s Manual

Digital Electronic Thermostat With RF

Installation, Operating and Maintenance Manual

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

PAC1500Xi PORTABLE APPLIANCE CHECKER

Instructions for the fan motor control system, SILVER C

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

DUAL OPTIC. Installation manual

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

5000 Series Rack Panels

1022 R/T Remote Monitor

Mobrey MCU900 Series Universal Control Unit

Analog Melting Point Apparatus

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Operating Instructions. For. Alarm Control Module. Model SSR 500

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Analox Safe-Ox/Safe-Ox He

OilSET-1000 (12 VDC)

Transcription:

INSTRUCTION MANUAL 8100 & 8200 Monitor Manual Issue 06

** This page is intentionally left blank **

Table of Contents 1 Introduction... 4 1.1 Manual Conventions... 4 1.2 Version 4 PCBA's... 4 1.3 Product Description... 4 1.4 Applications... 5 2 Installation... 7 2.1 Location... 7 2.2 Mounting Options... 7 3 Electrical Connections... 8 3.1 Supply Voltage... 8 4 Configuration... 9 4.1 Setpoint... 9 4.2 Delay... 9 4.3 8100/8200 Mode Switching... 10 5 Sludge Blanket Level Detection... 11 5.1 Description... 11 5.2 Sensor Installation... 11 5.3 Monitor Configuration... 11 6 Maintenance... 13 6.1 Inspection... 13 6.2 Fault Finding... 13 7 Technical Support... 14 7.1 Returning Instruments for Repair... 14 8 Technical Specification 8100/8200 Monitor... 15 9 Declaration of Conformity... 16 Page 3 of 18

1 Introduction 1.1 Manual Conventions This manual covers the 8100 & 8200 Version 3 Monitors The manual describes the configuration and operation of the 8100/ 8200 Monitor and includes information regarding sensors. All dimensions stated in this manual are in millimetres unless otherwise stated. The manual has been written on the basis that the user has a basic knowledge of instrumentation and an understanding of the type of measurements being made. Whilst every attempt has been made to ensure that the instructions are correct, common sense and good engineering practice should always be used to adapt to specific site requirements. Training in the use of the 8100/ 8200 Monitor can be provided by Partech, please contact sales for further information. email: sales@partech.co.uk phone: +44 (0)1726 879800 fax: +44 (0)1726 879801 1.2 Version 4 PCBA's In August 2013 a new version of the PCBA's were introduced, these boards have no significant effect on the function of the monitors and this manual is largely unchanged. At the same time the front panel graphics were changed to: Amended sections are indicated by the symbol. 1.3 Product Description The 8100 Monitor is a single channel instrument for use with one sensor. It provides a single alarm relay output and a single fault relay output. The alarm set point and delay are configured using controls mounted on the front panel. The status of the input channel is indicated by three LED s. The 8200 Monitor has two input channels for use with two sensors. It provides two alarm relay outputs (one for each channel) and a single fault relay output. The fault relay is used to indicate a fault on either input channel. The 8200 Monitor has two pairs of set point and delay controls and two sets of status LED s. The alarm set point and delay for each channel can be independently set and the status of each channel is indicated separately. From version 4 onwards the 8200can be set to operate as a single channel monitor using a jumper located next to the right hand terminal block, see section 4 for details The 8100/ 8200 Monitor has an IP65 rated enclosure and is suitable for outdoor use, however, a protective cover or outer enclosure is recommended to further protect the instrument from harsh environmental conditions. Page 4 of 18

1.3.1 Options Part Number Description 163600 163610 171360 8100 Monitor Version 3 (115/230VAC) 8200 Monitor Version 3 (115/230VAC) 8100/8200 Monitor 24VDC Supply Option 1.3.2 Compatible Sensors The 8100/ 8200 monitor can be used with the following Partech sensors: IR Series IR8, IR15, IR40, IR100 ST Series 0 1500mg/l, 0 10000mg/l, 0 30000mg/l 1.3.3 Fault Indication Fault indication is via the illumination of a status LED that is clearly visible on the front panel of the monitor. When there is a fault present the orange FAULT LED illuminates. 1.3.4 Alarm Activation When the sensor is clear and not in a fault condition then the green OK LED is illuminated. If however, the sensor is obscured or blocked then the relay will enter into the alarm condition and the red ALARM LED will become illuminated. 1.3.5 Delay Operation A delay can be introduced between conditions for an alarm turning on being met and the relay changing state. At any time during the selected delay, if the conditions for turning the alarm on are removed, then the delay will end and the alarm relay will not change state. The delay can be set between 1 & 90 seconds. The delay function is in place to try to avoid the occurrence of false alarms that may be caused by suspended debris. 1.3.6 Alarm Relays The alarm relays are internally configured for fail safe operation. When power is applied and the sensors are clear the relays will be energised, on alarm the relays are de-energised. Each alarm has normally closed and normally open contacts for external signalling, the normal condition is when the unit is powered and the alarm is off. 1.3.7 Fault Relay The fault relay is activated in two instances: when there is a problem with a sensor or due to a failure in the power supply to the system. In the latter case, this will cause the relay to be de-energised, resulting in a fault state. The fault relay is common to both channels on the 8200 and will be activated if one of the sensors fails or is removed. The relay can be wired as normally closed or normally open on the output side depending on customer preference. 1.4 Applications The 8100 & 8200 Monitors, when combined with a compatible sensor, are designed for use as a sludge blanket level detector, a sludge density switch, or as a suspended solids/turbidity switch. The 8100 & 8200 Monitors are therefore suitable for interfacing with automatic de-sludging control of primary and secondary settlement tanks, thickener control through high and low blanket level alarm, or as a simple alarm in a water/ waste water flow. 1.4.1 Sludge Blanket Level Detection When used for this operation the monitor uses an IR or ST series sensor, which is suspended by its cable to the desired monitoring depth in the tank. When the settled sludge reaches the sensor then the alarm output is activated. This can then be used as an input to a process system to directly control pumps, bell mouths or simply to alert the operator. The same principle can be used to monitor when the sludge reaches a minimum point when it is being removed from the holding tank. Page 5 of 18

1.4.2 Suspended Solids Switch The 8100/8200 Monitor can be used as a suspended solids switch when used in conjunction with the IR and ST series sensors. The sensor can be installed in an effluent channel to detect a value of suspended solids and give a high alarm. Page 6 of 18

2 Installation 2.1 Location The 8100/8200 Monitor is housed in an IP65 enclosure and is therefore suitable for field mounting. It is advisable to mount the monitor in a location that has some protection from the environment; this could be a GRP/metal cabinet, in a central room or the use of a protective shield. Suitable enclosures can be provided by Partech. 2.2 Mounting Options A range of mounting options are available for the 8100/8200 Monitors, which will allow the user to install the sensor in a wide variety of locations. The 8100/8200 Monitor is designed so that it can be surface mounted, the hole positions required for this are shown on the left below. 120.00 5.00 DIA 5.00 75.50 75.50 6.00 Mounting hardware such as handrail brackets, protective hoods and sensor brackets are available from Partech. The 8200 Monitor using the standard bracket (Part Number 171280) is shown on the right above. When mounting the sensor and monitor it is recommended that the two entities be kept as close together as possible so that the calibration process is simplified. The sensors are supplied with a standard length of 10 metres of cable, though this can be increased on request to a maximum of 100 metres. The cable can be extended using a junction box and good quality instrument cable (3-core minimum). Page 7 of 18

3 Electrical Connections WARNING: DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THE TERMINAL COVER Removing the terminal compartment cover, which is located at the base of the front panel, gives access to the 8100/8200 Monitor electrical connections. Before removing the terminal cover make sure that the electrical supply to the instrument is disconnected. When the instrument is installed, it is essential to check that the supply voltage selector switch position is correct for the intended supply voltage. If this is not checked the instrument could be damaged. The voltage selector is shown below From version 4 onwards a universal 100 to 240 VAC power supply is used and it is not necessary to switch the mains voltage Fuse Voltage Selector ALARM 2 FAULT 0V 12V 0V SENSOR 1 INPUT 12V 12V CLEAN O/P INPUT N/O GND N/C N/O COM N/C N/O COM N/C N/O COM LIVE EARTH NEUTRAL 2 ALARM 1 SENSOR 2 Connection Terminals The electrical supply to the unit should be installed such that there is a means of isolating the supply to the unit and the supply is protected with a fuse or trip. The instrument has a supply fuse fitted internally. The 8100 monitor is supplied with three PG11 cable glands fitted and has provision for a further PG11 gland, whereas the 8200 comes with four fitted cable glands. If any fitted cable glands are not being used then the glands must be sealed to prevent the ingress of moisture into the unit. POWER ALARM 1 ALARM 2 CLEAN O/P FAULT SENSOR 1 0V 12V SENSOR I/P 0V SENSOR I/P 12V 12V N/O GND N/O COM N/C N/O N/C COM N/O COM N/C EARTH LIVE NEUTRAL Shown below are the terminal connections for the 8100/8200 Monitor. SENSOR 2 Sensor Type 3.1 Terminals IR Series Sensor ST Series Sensor Sensor I/P White White Sensor 12V Red Red Sensor 0V Black/ Blue Black/ Blue Supply Voltage The supply voltage for the 8100/8200 Monitor is available in 115/230VAC, or 24VDC versions. From version 4 onwards a universal 100 to 240 VAC power supply is used and it is not necessary to switch the mains voltage Page 8 of 18

4 Configuration 8200 CHANNE L 1 OK ALARM SE TP OINT D ELAY FAULT CHANNEL 2 OK ALARM SE TP OINT D ELAY FAULT Setpoint and Delay Controls and status indicators are situated on the front panel of the 8100/8200 Monitor (front panel of 8200 monitor shown above). To access the adjustment dials then the outer cover must be opened. The front panel has a setpoint and a delay adjustment control and also on the front panel are the three status indicators: OK Green LED ALARM Red LED FAULT Orange LED 4.1 Setpoint The type of sensor used determines the measurement/detection range of the system. It is however possible to do some field adjustment and fine tuning of the system once installed. By turning the setpoint control from fully anti-clockwise to fully clockwise it is possible to alter the setpoint from 5-95% of the range of the sensor. 4.2 Delay The delay control is used to alter the length of time after an alarm condition occurs that the alarm relay is activated. Once an alarm condition ends, the delay will also determine how long the alarm relay remains in the alarm condition before deactivating. The delay can be set between 1 and 90 seconds and is used to prevent false alarms being indicated. For example when the sensor signal momentarily goes above the alarm value due to unrepresentative debris. To increase the length of delay the control marked DELAY on the front panel of the 8100/8200 Monitor should be turned clockwise. When turned fully clockwise the delay is set at 90 seconds. Page 9 of 18

4.3 8100/8200 Mode Switching From version 4 it is possible to configure an 8200 Monitor to operate as a single channel monitor. This can be changed in the field by moving the jumper in J7 to the 8200 position When the jumper on a 8200 Monitor is on the 8100 position the Sensor 2 channel is disabled and the fault alarm will act on Sensor 1 only. Please note it is not possible to change an 8100 into an 8200 even if a new front panel is purchased Page 10 of 18

5 Sludge Blanket Level Detection 5.1 Description The typical sludge blanket level detection installation is in a settlement tank. The system is made up of a single or dual sensor configuration and a monitor. There will also be associated mounting hardware, which is dependent upon the applications requirements. The monitor is typically mounted on a handrail on the bridge of a settlement tank. The sensor is suspended by its cable; though it should be noted that the sensor must be fastened to the fixing point provided by the mounting bracket and is not left to hang from the cable gland at the base of the monitor. 8100 Monitor with Alarm LED Activated Settlement Tank 8200 Monitor Settlement Tank SUPERNATENT SUPERNATENT SUPERNATENT SUPERNATENT SLUDGE SLUDGE SLUDGE SLUDGE When mounting the monitor and sensor on a settlement tank with rotating bridge, the sensor should normally be located on the leading edge, approximately half way between the centre and outside edge of the tank, as shown above. Care should be taken when mounting the sensor to ensure that it does not trail into the scraper. 5.2 Sensor Installation Once the bracket/monitor has been attached to the handrail via the saddle clamps and U-bolts and the sensor has been connected to the monitor, it is then a matter of passing the cable through the various retaining clamps and lowering it into the settlement tank to the desired depth at which the sludge blanket is required to be detected. When assessing mounting options, attention should be paid to the accessibility of the sensor for calibration and maintenance, stability of the sensor in the flow conditions present on site and it must also be ensured that when mounting the sensor it is fully submerged at all times. The sensor can be suspended by its cable, but the top end of the cable must be fastened to a fixed point. It should be noted that the sensor must not be allowed to hang direct from the cable gland at the bottom of the monitor. 5.3 Monitor Configuration When supplied the factory mid-point settings may not be suitable for the required application. If this is the case then the following procedures should be undertaken 5.3.1 Blanket not detected If the sensor is not detecting the sludge blanket and the green OK light remains on when the sensor is in the blanket, take the following action: With the sensor in the sludge blanket, the setpoint control should be turned anti-clockwise slowly until the red ALARM LED illuminates. This indicates that the sensor has detected the sludge blanket. Page 11 of 18

5.3.2 Blanket continually detected If the sensor is continually detecting the sludge interface and the red ALARM LED stays on when the sensor is above the sludge blanket the following action should be taken: With the sensor above the sludge blanket, set the delay to the minimum, then the alarm point control should be slowly turned clockwise until the green OK LED illuminates. This indicates that the sensor is correctly, not detecting the sludge blanket. Note: If the setpoint control is turned fully clockwise and the detector continually indicates the presence of the sludge blanket when the sensor is above the blanket, the sensor that is fitted is too sensitive and an alternative sensor will have to be fitted For accurate adjustment of the setpoint to a required level: 1. Immerse the sensor fully in a known sample of the required value. 2. Turn the alarm point control fully anti-clockwise; the green OK LED should illuminate. 3. The alarm point control should be turned clockwise until the red ALARM LED illuminates. The desired alarm point has now been set and the controller will now detect sludge blankets of this value or higher. Note: In the event of the sensor being changed, it will be necessary to repeat the above alarm point adjustment in order to obtain accurate results Page 12 of 18

6 Maintenance To maximise the operational life of the monitor and sensor, regular inspection is recommended. The frequency of this is dependent on the specific operation of each site, however an initial weekly inspection to observe the characteristics of the application is recommended, long term operational practice can be decided from these inspections. The manual clean system requires the physical removal of the sensor from the application for the cleaning of the lenses to be carried out. It is advisable that at regular intervals the sensor is removed from the application and both the lenses and the sensor body are cleaned along with the mounting brackets. 6.1 Inspection It is envisaged that an inspection of the monitor and sensor will include the following: Check security of brackets Removal of the sensor from the application. Checking for damage to cables. Cleaning of the sensor using a suitable detergent and removal of all ragging. Inspection of the glass lenses for staining, scouring, cracks or chips. Checking for moisture/signs of leakage inside the sensor and monitor. 6.2 Fault Finding The following can cause a false alarm or fault signal: Material (rag, weed, etc) caught on the sensor and affecting the measuring system - remove sensor, manually clean and re-install. Turbulence (caused by high flow, aeration etc) in the solution being measured position the sensor so turbulence has as minimal effect as possible on the sensor. Bad connection of the sensor cable - check all connections are securely fastened Page 13 of 18

7 Technical Support Technical Support is available by phone, fax, or e-mail, the details of which are shown below. Phone: +44 (0) 1726 879800 Fax: +44 (0) 1726 879801 email: techsupport@partech.co.uk website: www.partech.co.uk/ To enable us to provide quick and accurate technical support please have the following information ready when you contact our Customer Support Manager: Monitor type, serial number, and software version number. Sensor type, and serial number. Application details. Description of fault. 7.1 Returning Instruments for Repair If equipment needs to be returned to Partech for repair or service the following address should be used: SERVICE DEPT. PARTECH (ELECTRONICS) LTD CHARLESTOWN ST AUSTELL CORNWALL PL25 3NN UNITED KINGDOM Please include the following information with the returned equipment. Also ensure that sensors are adequately protected for transportation (Advice on packing can be provided by our service department). Contact name and phone number. Return address for equipment. Description of fault or service required. Any special safety precautions because of nature of application. Page 14 of 18

8 Technical Specification 8100/8200 Monitor 8.1.1 General Mains Power Version:...100 240 VAC 50/60Hz +10%/-15% DC Power Version...9 36VDC Power Consumption...8VA Supply Fuse...Fuse AS 20mm 500mA glass Anti Surge 250VAC (fitted internally) Operating Temperature Range...0 to 50 C Storage Temperature Range...-20 to +60 C 8.1.2 Alarm Outputs Number of Outputs...8100-1 alarm,1 fault...8200 2 alarms, 1 fault Alarm Type...SPCO Operation...Fail Safe (De-energised in alarm condition) Relay Rating...5A @ 230Vac, 5A @ 30Vdc 8.1.3 Enclosure Enclosure Materiall...ABS Cable Glands...M20 Terminals...Max conductor cross section 2.5 mm2 Environmental Rating...IP65 Weight...1 Kg Dimensions...160 x 195 x 105 mm (h x w x d) 8.1.4 EMC EMC...EN 50081-1 (1992), EN 50082-1 (1994) Version 3 Mains Power Specification - 115/230 VAC 50/60Hz +10%/-15% (Voltage Selector)) Version 3 DC Power 9-18 VDC OR 18-36 VDC Version 3 fuse rating is 100mA Anti surge 20mm x 5mm (fitted internally) Version 3 glands are PG11 Page 15 of 18

9 Declaration of Conformity DECLARATION OF CONFORMITY to EMC and Low Voltage Directives We, Partech (Electronics) Limited, Charlestown, St Austell, Cornwall, United Kingdom, declare under our sole responsibility that the product to which this declaration relates: Product Name: 8100 and 8200 Monitors and associated sensors Model Number(s): 163600, 223644, 163610, 223646 Is in conformity with the standards noted below: EN 61326:2008 Electrical equipment for measurement, control and laboratory use EMC requirements BS EN 61010-1:2001 IEC 61010-1: 2001 Safety Requirements for electrical equipment, control and laboratory use Following the provisions of European Directives: 2004/108/EC 2006/95/EC EU EMC Directive Low Voltage Directive Roger Henderson, Technical Director, 6th December 2010 for Partech (Electronics) Ltd, 111/3 Charlestown Road, St Austell, Cornwall PL25 3NN, UK Page 16 of 18

Page 17 of 18