Operation Manual. Plateheatexchanger. Read and follow the operating instructions and safety information before using for the first time.

Similar documents
Operation Manual. Read and follow the operating instructions and safety information before using for the first time.

Operation Manual. Pond Pump Series HJ and CQP

Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202

Operation Manual Airbrush Compressor AH28A ARTICLE 34247

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

Manual. WilTec 3/1 Macerator Toilet Pump System Article 50741

Operation Manual ARTICEL

ARTICEL 51627/51628/51629/51630/51631/51632/51633

Pressurefilter CPF-Series

Operation Manual. Trash Water Pump ARTICLE Image similar

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

Installation and operating instructions. DK energy storage and DK energy buffer

SB Series Brazed Plate Heat Exchanger Installation Manual

Installation, Operation and Maintenance Manual

Brazed Plate Heat Exchanger Operations Manual

Air Cross 21 Installation and User Manual

General safety precautions English

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Quality Heat Exchangers

USERS MANUAL FOR GAS BOILERS

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

LYOTRAP FREEZE-DRYING MACHINE OPERATING INSTRUCTIONS

Operation Manual Breeding Machine / Hatcher 56S ARTICEL 51185

Heat pump and energy recovery systems

General safety precautions English

EHA Hoffmann International GmbH

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

BRAZED INSPECTED PLATE HEAT EXCHANGER SCAMBIATORI DI CALORE SALDOBRASATI ISPEZIONABILI CIESSE

Evaporators. Direct Expansion Flooded Recirculated Over Feed

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

TMCI Padovan Evaporators

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Brazed Plate Heat Exchangers TTP s Series

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

Quality Heat Exchangers

PDA20DX Air Purifying Dehumdifier Manual

Propane Flame Projector Safety instructions and operating manual

User manual Flushing device VAS 6337/1a

Solar water heating system

1. Description. 2. Application and Installation Considerations

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

ecodry Figure 1 - Process Diagram ecodry B General Process Description

Aerosol flame projector with spark effect Safety instructions and operating manual

Advanced heat transfer technology

smardy - pure water Reverse osmosis system YR100-A 75 GPD

Instruction Manual. Pharma-line ESE02198-EN Original manual

Waste-heat recovery: Weighing in the environmental Factor

Local Air Conditioner

Instruction manual. Water treatment Boiler system D 30 L

Niles Steel Tank Hot Water Generator Installation and Operation Manual

Instructions manual DEHUMID HP50

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

WHE 2.24 / WHE 2.24 FF

Installation, Operation and Maintenance Instructions for ThermaFlex Brazed Plate Heat Exchangers

Instruction Manual Centrifuge LC 6 with horizontal rotor 6 x

OPERATING INSTRUCTIONS

DAIKIN Huizhou Factory Profile

Assembly- and User Manual Electric Infrared- Patio Heater MODEL: Geda HS - 2 kw Art. Nr. HS 10000

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

UNIT 5 COOLING SYSTEMS OF IC ENGINES

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

Portable Air Conditioner

Installation instructions

Screw-in heater (EHK)

Quality Heat Exchangers

Evaporative Cooling products

1300W Pressure Washer RACHP133A

READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OR OPERATION.

SUN EQUINOX HEATING SYSTEMS

- 1 - Updated on 18 March, 2010

Commissioning a Solar Thermal Installation

Tips & Technology For Bosch business partners

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

MODEL 7000 SUCTION UNIT

APV ParaFlow Plate Heat Exchangers

Brown Hills College of Engineering & Technology

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Kompernaß GmbH Burgstrasse 21 D Bochum ID-Nr.: KH /05-V2

Instruction Manual. 1. Introduction

Operating Instructions FREEZER

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

BLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC.

LONGONI ENGINEERING SRL

Dehumidifier. Instruction Manual. Model DH-320/A

Hot Water Heating Systems

Compact Refrigerator. User's Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE USING YOUR REFRIGERATOR AND KEEP IT FOR FUTURE REFERENCE.

Instruction and Maintenance Manual. Spiral Heat Exchanger

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Compression of Fins pipe and simple Heat pipe Using CFD

PLATE HEAT EXCHANGERS

OPERATION MANUAL. Model: IC702/703 Ice Maker

Condensing Unit Installation and Operating Instructions

ELECTRIC BOILERS FOR CENTRAL HEATING

Transcription:

Operation Manual Plateheatexchanger Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments, illustrations, functioning steps and technical data can differ insignificantly. Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us. by WilTec Wildanger Technik GmbH Seite 8

The information contained in this document is subject to change without prior notice. No part of this document can be copied or duplicated in another form without the prior written consent of WilTec Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liability for any errors in this user manual or the connection diagram. Although WilTec Wildanger Technik GmbH has made every effort to make sure that this user manual is complete, accurate and updated, errors cannot always be avoided. In the event of problems with this user manual please complete and send this form back to us. FAX-notification (+++49 2403 55592-15), from: Name: Firm: Tel/Fax: I would like to report the following mistakes: Customer Service WilTec Wildanger Technik GmbH e-mail: service@wiltec.info Tel:++ +49 2403 55592-0 Introduction Thank you for purchasing this quality product. To minimize the risk of injury by means of fire or electric shock we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Always use a grounded power connection with the appropriate mains voltage. You can find the corresponding mains voltage on the type plate. If you have any doubts about the connection being grounded, have it checked by a qualified professional. Never use a faulty electric cable. Do not inspect the electrical part of the pressure pond filter in a wet or damp environment or when you are wet yourself and protect it from direct sunlight. Install this device in a safe location so that nobody can step on the cable, fall over or damage it. Disconnect the power plug before cleaning it and use only a damp cloth for cleaning. Avoid using cleaning agents and make sure that no liquid enters the electrical part of the pump. The electric part of the device contains no parts that can be inspected or serviced by the user. Leave the maintenance, adjustment and repair to qualified technical personnel. In case of unauthorised intervention the 2-year warranty is no longer valid! Keep these operation instructions safe. by WilTec Wildanger Technik GmbH Seite 9

A plate heat exchanger is a form of heat exchanger. Heat exchangers are also called heat carriers. The term is appropriate because during the process there is no heat exchange that takes place but a heat transfer from one medium to another one. As suggested by its name, the plate heat exchanger consists of wave-shaped panels that are assembled in a unique way. There are interspaces between the plates. These interspaces are flown alternately by the heat-absorbing and the heat-dissipating medium. The device is sealed both towards the outside and beneath the mediums which is effected by different way. There are screwed plate heat exchangers disposing of a variety of advantages. They are expandable for example and conduct the flow in different ways. As for the construction, there are different types of plate heat exchangers. It is the so-called soldered plate heat exchangers that are preferred being characterized by the fact that the different plates are soldered with each other. By this means you can renounce any other assembly. Plate heat exchangers work efficiently because they ensure a strong heat transfer which can even be increased by generating turbulences during the process of flow-through. The turbulent flow-through is effected by the corrugated profile of the plates. Albeit plate heat exchangers need not necessarily be large they a efficient by providing for a large heat flux density. Plate heat exchangers are components that dispose of a high power density. Thanks to compact dimensions and low weight they are highly efficient. Soldered plate heat exchangers consist of embossed stainless steel plates being soldered with copper by the use of a vacuum procedure. When being assembled, each second plate is rotated by 180 degrees in the plane, thus forming two separately rotated flow chambers by the means of which the mediums being involved in the heat transfer are conducted in counter flow. The plates embossing generates a highly turbulent flow-through thus providing for an effective heat transfer even in low volume flows. Due to said highly turbulent flow-through even at low speed, a self-cleaning process is caused which essentially reduces the danger of calcification and contamination. by WilTec Wildanger Technik GmbH Seite 10

It is not only used in the field of industrial heating technology but also in cooling and solar technology. CHP Air conditioning systems Heating pumps Floor heating Thermal power station Heat extraction Air heating Air conditioning in buildings Food industry Refrigeration and air-conditioning systems Heating domestic waters Heating supply networks Solar thermal systems Frost-endangered heating systems Heating of regenerative fuels Heat recovery systems Vegetable oil conversion for cars and trucks System division for underfloor heating Chemical and pharmaceutical production process Transfer stations in district heating supply network Plate heat exchangers should be assembled in a way that there is sufficient space to perform maintenance. The position for installation should be selected the way that the plate heat exchanger can be ventilated and emptied. The minimum distance for the mounting on the thermal insulation is 40 mm. As for heattechnical applications the vertical mounting position is most effective. Any other position for installation could lead to power loss. Refrigeration applications such as evaporator or condenser systems always require vertical installation. Never assemble the heat exchanger with the connections in a downwards position. The heat exchanger should be preventively mounted on a console. A support only on the ports is not sufficient. Make sure that there are no vibrations and/or pulsations affecting the heat exchanger. If necessary, you install expansion joints to ensure that there are no forces acting directly on the ports. Connection to the pipe network: A Primary side heating technology: primary on / off B Primary side refrigeration: Refrigerant on / off Heat exchangers are connected in reverse flow. ATTENTION: Pipelines should be routed the way that movements inside the pipes or improper forces to not act on the plate heat exchanger! by WilTec Wildanger Technik GmbH Seite 11

ON Primary OFF Secondary OFF Primary ON Secondary Before commissioning it is necessary to compare the operating data with the manufacturer s indications with regard to their agreement. Moreover, all screw connections have to be checked. The pumps that are providing the plate heat exchanger must be equipped with shut-off valves. The pumps must not suck in air in order to exclude possible malfunctions caused by strokes of water. During the filling of the system, the plate heat exchanger has to be ventilated in order to achieve fully performance. For prolonged deadlock of the system, the heat exchanger must be completely emptied and cleaned. This holds especially true for danger of frost, aggressive media and media tending to biological fouling. After start up you have to check that there are no pressure pulsations. In case the heat exchanger is mounted between a control valve and a differential pressure regulator it has to be ensured that in case of simultaneous closing of the two regulatory entities there is no vacuum pressure. This is to prevent any steam impacts. Generally, it must be ensured that there are no operating conditions being in contradiction to this assembly operation and maintenance manual. The formation of ice causes the destruction of the heat exchanger. At temperatures close to freezing point it is recommended to use antifreeze agents (e.g. glycol). There are many different factors that may influence the fouling and contamination. These are for example: speed, temperature, turbulences, distribution and the quality of water. As for the use of media which may be contaminated such as for example surface waters, cooling circulation water (open circulation), by WilTec Wildanger Technik GmbH Seite 12

heating water and the like it is advisable to install filters on the plate heat exchanger thus minimizing the danger of contamination. The media have to be effected with a maximum of mass flow. Low mass flows (partial load) the turbulence inside the heat exchanger can be affected thus increasing the tendency for contamination. ATTENTION! Poor water quality causes an increased susceptibility to corrosion! With temperatures above 60 C there can be lime sediments on the heat exchanger s surface. A turbulant flow-through and lower temperatures reduce the risk of calcification. During the process of shutdown it must be ensured that first the primary side and thereafter the secondary side is closed. When starting the system it is the secondary side first to be opened and then the secondary one. By this means overheating of the heat exchanger is excluded. ATTENTION: The regular maintenance as well as the compliance with all regulations concerning the water quality reduces the risk of fouling. Fouling increases the susceptibility of corrosion. In case you expect the formation of sediments due to poor water quality (e.g. extensive values of hardness or high contamination) there should be a purification at regular intervals. There is the possibility of cleaning by flushing. The heat exchanger is to be flushed against the normal direction of flow with a suitable cleaning solution. by WilTec Wildanger Technik GmbH Seite 13