GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Similar documents
GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Ø 1000 * 588 mm 50 kg

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Duct Cable GYTS-144B1.3

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Fiber Optic Distribution Cables (6-144 Fibers)

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

HELKAMA. Optical Fibre Cables

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Fibre Optic Cable. Catalogue.

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

SPECIAL ELECTRICAL AND OPTICAL CABLES

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

industry solutions: military

Fibre Specification Standards

Special Provision No. 683S28 December 2017

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Fibre optic media options and trends

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

DNVGL-CP-0402 Edition February 2016

FIRE RESISTANT CABLES

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

High Performance LSZH Fire Resistant Cable

fire resistant cables

Connectors for Optic Fibre Cable

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

ENHANCED FIRE PERFORMANCE CABLE

Main features of the JETnet system

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Fibre (TIA) Field Test Specification

CATEGORY 6A FTP RJ45 SOLUTION

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Fiber Optic Patch Cord and Pigtails

Industrial Wire and Cable Solutions Line Card

Detection of Solvents using a Distributed Fibre Optic Sensor

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Multi-Core Fire Resistant Cable

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Fujikura-70S Single Fibre Fusion Splicer

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Agencavi Srl has been specializing in the distribution of special cables and accessories for industrial automation since 1983.

FiberExpress Solutions

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

Installation Considerations for Pipelines

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Product Catalogue. External Management

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

MT-RJ Optical Fiber System Field Testing

S Low loss coax cables with foamed PE

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

5. Identification products.

Caledonian Flame Retardant Coaxial Cables

FIRE PERFORMANCE CABLE

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

PRODUCT CATALOGUE Norröna

WG Buried Fibre Cable Long Perimeter Detection System

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

06-Electrical Low Voltage Standard Technical Specification (LVSTS)

Product Information. Optical fibre water sensor. - Early warning system for ensuring maximum availability of optical transmission routes

Catalogue Telecommunication Cables INTRODUCCIÓN

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Dome Fiber Optic Closure SC-221

Firecel Safety Cables

4-Channel Contact Closure Fiber Link Card System

INSTRUCTION MANUAL W-400

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Transcription:

GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GUSN102 GUSN104 GUSN106 GUSN108 GUSN112 GUSN116 GUSN124 -OM2 BW GUSN202 GUSN204 GUSN206 GUSN208 GUSN212 GUSN216 GUSN224 -OM3 GUSN302 GUSN304 GUSN306 GUSN308 GUSN312 GUSN316 GUSN324 -OM2e GUSN402 GUSN404 GUSN406 GUSN408 GUSN412 GUSN416 GUSN424 -OM2 BW 500/500 GUSN502 GUSN504 GUSN506 GUSN508 GUSN512 GUSN516 GUSN524 -OM4 GUSN602 GUSN604 GUSN606 GUSN608 GUSN612 GUSN616 GUSN624 9/125 ITU G.655 GUSN702 GUSN704 GUSN706 GUSN708 GUSN712 GUSN716 GUSN724 9/125 ITU G.652D-OS2 GUSN802 GUSN804 GUSN806 GUSN808 GUSN812 GUSN816 GUSN824 Std. plywood reel (non-returnable) Std. delivery length Ø800*475mm 7.65 kg Ø1000*530mm 18.0 kg 2100m ± 100m 4100m ± 100m Applications For outdoor and indoor use in structured (data) wiring systems such as campus backbone, building backbone (riser) and/or Horizontal cabling. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Easy to install in ducts, tunnels and trenches. Suitable for direct burial. Features & Benefits These cables are halogen-free ( = FRNC and LSNH) and therefore suitable for both outdoor and indoor use. Consequently splicing can be avoided and the installation gets more cost-effective. A simple all dielectric cable construction (and consequently more cost-effective up to 24 fibres then multi-tube cables) with standard rodent protection. Predicted lifetime > 30 years.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794) 1. Primary coated optical fibres: Ø 250 ± 15 um. 2. Central tube, jelly filled (non-dripping and silicon-free) with up to 24 fibres. Individually colour coded optical fibres: 1 12: red natural yellow blue green violet brown black orange - turquoise pink and white. 13 24: red natural yellow blue green violet brown grey orange turquoise pink and white with rings. 3. Swellable (for the longitudinal watertightness) yarns as strength members and for the standard rodent protection. 4. Orange halogen-free (FRNC/LSNH) outer jacket. Identification: BELDEN OFC cable type number x type of fibre +date-, meter- and P/N-marking. Mechanical Data No. of fibres Max. 24 Ø Central tube (mm) 3.3 Ø nom./max. (mm) 5.8 / 6.1 Energy of flame (kj/m) Weight (kg/km) 37 2

Optical Characteristics Characteristics (cabled) Single-Mode Matched-Cladded optical fibres according to ITU. European Partnumber Coding, Position 5 Fibre-Type Mode- Field /Cladding Diameter (um) Attenuation average/ max. (db/km) Dispersion (ps/(nm-km) PMD (ps/km) Cable Cut-off 8 9/125 G.652D OS2 9.2 ± 0.4 125 ± 0.7 1310 1 0.32 / 0.40 0.21 / 0.30 3.5 18 0.2 1260 7 9/125 G.655 8.4 ± 0.6 1 0.25 / 0.30 3.5 8.5 < 0.1 A 1260 Note A- Link design value Characteristics (cabled) Multi-Mode Graded-Index optical fibres according to IEC 60793 European Partnumber Coding, Position 5 Fibre- Type Mode-Field Diameter (um) Attenuati on average/ max. (db/km) Bandwidt h (MHzkm) Ethernet Performance (m) 1GBE 10 GBE Num. Apert. (µm) Refr. Index 1 62.5/125 OM1 62.5 ± 2.5 2.7 / 3.2 0.6 / 1.1 200 275 33 0.275 ± 1.495 1.490 5 OM2 2.4 / 3.0 0.7 / 1.0 82 1.481 1.476 2 OM2 2.3 / 2.8 0.6 / 0.9 1200 82 1.481 1.476 4 OM2e 50 ± 2,5 2,3 / 2,8 0,6 / 0,9 1200 750 2000 110 na 1,481 1,476 3 OM3 2.5 / 3.0 0.5 / 1.0 1500 900 300 1.482 1.477 6 OM4 2.5 / 3.0 0.5 / 1.0 0 900 1.482 1.477 A test report (attenuation) is supplied with each delivery. 3

Mechanical, Physical and/or Environmental Characteristics Requirements Temperature range according to IEC 60794-1-2-F1 Tansport/storage Installation Operation Pulling tension according to IEC 60794-1-2-E1 Long term Short term Bending radii for fibres and tubes Installation/operation Watertightness according to IEC 60794-1-2-F5 Crush resistance according to IEC 60794-1-2-E3 Cable Bending radii cable Static according to IEC 60794-1-2-E11 Dynamic according to IEC 60794-1-2-E6 Flame retardancy according to IEC 60332-1 (EN 50265-2-1) -30 to + 70 C -5 to + 50 C -30 to + 70 C 700 N 1500 N >25 mm Yes 15000 N/ m 10 x ø 15 x ø Pass Halogen-free according to IEC 60754-2 (EN 50267-2-2) Corrosivity ph 3.5 - µs/cm 100 Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Outdoor cables with a black PE outer jacket. Non-standard cable constructions, colours, details and/or additional information regarding specifications are available on request. 4

Revision Rev. Description Date Init. 1.1 Changed flame retardancy from IEC 332-3C to IEC332-1 02/04/2009 TvR 2.0 OM3+ changed to OM4 12/10/09 JW 3.0 OS2 added 25/11/09 JW 4.0 Crush resistance increased 29/03/10 SN 5.0 Diam. Tube changed to 3.3mm 28/10/10 SN Date: 17/02/09 Page 1 of 1 Part Number: Orig.: SN Review: GUSN 5