SP40S-D. Kingfisher Company, inc. Features: Description:

Similar documents
SAFEPATH Mass Notification System (SPMNS)

Autonomous control unit

SAFEPATH DoD facility communications system & expansion options

SAFEPATH SAFEPATH. Emergency communications system

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

July 14, 1999 DF C-100.

Multiple Input and Output Modules

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100C. Emergency Command Center

June 10, 2002 DF C S2424

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ECC-50/100(E) Emergency Command Center

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

Speakers and Speaker Strobes

Figure 1. Figure 2. See notes 1 and 2 below.

SAFEPATH Operation and Installation Manual

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Table 1: Attenuation Rating Switch Position. Position Attenuation (db) Attenuation (db) (Approx.)

Conventional Smoke Detectors KFAPO

AL600ULADA. NAC Power Extender. Installation Guide

INSTALLATION INSTRUCTIONS TALKBACK MODULE

LifeAlarm Fire Alarm Controls

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

PN: 51604:A ECN Voice Evacuation Control Panel FIRE COMMAND 25/50X & FIRE COMMAND 25/50XE. Document # /17/02 Rev.

Booster Power Supply Manual

AND ARCHITECT SPECIFICATIONS

AL800ULADA. NAC Power Extender. Installation Guide

Specification/ Data Sheet

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Series DV-100 VoiceLink Operation and Installation Manual

1. POWERPATH Operation

E3 Series Broadband System

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

* These Remote Mics must be SPRM-GP

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

AND ARCHITECT SPECIFICATIONS

L-Series, Emergency Communication Devices

Fire Alarm System Inspection and Testing Report

TrueAlert Addressable Notification

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

TrueAlarm Fire Alarm Controls

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF INSPECTION AND TESTING

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

16 Zone Voice Evacuation VA & PA Sound System

E3 Series Broadband System

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Emergency Command Center ECC-50/100 ECC-50/100E. Instruction Manual. Document LS FL-E 5/3/2016 Rev: G P/N LS FL-E:G ECN

30.45 Electric Release PDRP-2001

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

FireNET Plus Wiring Instructions

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Addressable Fire Alarm Control Panel

INSPECTION AND TESTING FORM

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

MPC-6000 / MPC-7000 / RND-2

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

SECTION FIRE ALARM SYSTEMS

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

GAI-Tronics Corporation. Serverless Page Party (SP2) Publication : SP2 Intelligent Intra-Plant Communication and Emergency Notification System

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Unified Fire Authority - Fire Prevention Bureau

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

TrueAlert Notification Appliances

Expansion Modules & Accessories

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

MODEL B2 INSTALLATION MANUAL

Conventional Releasing Control Panel

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Fire Alarm Testing and Inspection Report

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

Vocia VACIE. Reference Guide

VACIE REFERENCE GUIDE REVISION 1.2.6

TrueAlarm Fire Alarm Systems

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

Transcription:

Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications The system is listed under UL 2572 for MNS, UL Standard 864, 9th edition delivering supervised audio and voice messaging with strobes and notification appliance circuits (NAC) for visual alerting Economic OSHA applications The system is OSHA 1910.165 compliant; this means that it does not require reliability inspections every two months, or the required spare parts inventory Wide ranging applications from small to large facilities Contact closure message activation 40 watts of supervised audio power Speaker outputs: 25V or 70.7V power limited Connectivity of optional speaker splitter modules Dual-tone tone generator with: Code 3 Tone and Slow Whoop for alerting of system trouble. Description: KCi s Emergency Communications System (ECS) is an In-Building MNS for fire alarm, emergency communications and voice evacuation with 24 VDC battery back up. Designed for Department of Defense facilities to meet the UFC requirements for automatic alarm audible shutoff after 10 minutes, the SP40S-D includes a 10 minute timeout feature. The ECS, which meets UL 2572 requirements for MNS, interfaces with a building fire alarm system (FAS) to provide a complete In-Building MNS. An integral part of the fire system, the ECS can control all audio and visual notification appliances for both fire and MNS and reports trouble and supervisory signal through the FAS. Supervised voice speakers controlled by the ECS can be used for both fire and emergency communication applications. The ECS single channel system is capable of delivering 40 watts of supervised high fidelity audio power and 2 amps of supervised 24 VDC synchronized strobe power. It comes standard with an on-board digital voice messaging system with 8 standard messages, a hand-held microphone for fire messages, power supply/battery charger and numerous additional features. A dedicated MNS microphone (ECS-MIC) will be utilized for live voice messages for emergency communications. The Emergency Communications System is expandable to 5280 watts utilizing the ECS-80/4 (80 watts and 4 amps of strobe power), the ECS-160 (160 watts) or ECS-320 (320 watts) supervised audio power boosters. All models available in 115 VAC or 220 VAC.

Features (continued): Audio power can be expanded by connecting to optional audio power boosters - KFSPB-80/4 80 Watt Supervised Audio Power Booster with 4 Amp of Synchronized Strobe Power - KFSPB-160 160 Watt Supervised Audio Power Booster KFSPB-320 320 Watt Supervised Audio Power Booster Voice Messages Complies to NFPA-72 requirements Supervised NAC speaker and strobe circuits Live microphone override 5 digitally pre-recorded MNS voice messages 3 digitally pre-recorded fire voice messages User selectable pre-tones for fire messages Flexible, field-programmable messaging capabilities Strobe Inputs and Activation 2 Amps of 24 VDC supervised strobe power with built-in sync protocol. Power limited. Strobe output is selectable for control of sync protocol or non-sync operation Strobe terminals have pass thru capability for sync or non-sync operation 24 VDC supervised and synchronized strobe power can be expanded to meet the requirements of the installation via connecting to optional KCi power boosters. Voice Messages Complies to NFPA-72 requirements Supervised NAC speaker and strobe circuits Live microphone override 5 digitally pre-recorded MNS voice messages 3 digitally pre-recorded fire voice messages User selectable pre-tones for fire messages Flexible, field-programmable messaging capabilities Live & Pre-recorded Message Announcement Supplied with 8 pre-recorded emergency messages Capable of in-field recording of all messages via 1/8 line level audio input jack On board Push-to-Talk Fire Microphone Dedicated MNS Microphone Benefits and Advantages One Supervised, Multi-Function, Voice Fire Alarm/ Emergency Communications System Interfaces with addressable FAS Built in power for visual notification appliances e.g., Strobes Expandable for larger system requirements (with optional equipment) Controls audio and visual notification appliances for both fire and MNS Voice speakers can be used for both fire and emergency communication applications Reports trouble and supervisory signal for both the FAS and MNS System Activation: Audio 70V or 25V input from the SPMNS 1 Volt input from SP4-RMX System Activation: Strobe (KFSPB-80/4) 8-33VDC NAC input connected to the strobe input Power Supply & Batteries Fully supervised patent pending circuitry always in effect Power limited circuitry Class D amplifiers Internal battery charger and power supply Required batteries fit inside the enclosure (sold separately) KFSPB-320 requires four 12 VDC, 12 AH batteries KFSPB-160 and KFSPB-80/4 require two 12 VDC, 12 AH batteries Outputs KFSPB-320 has four 80 watt speaker output circuits KFSPB-160 has two 80 watt speaker output circuits KFSPB-80/4 has one 80 watt speaker output circuit and two 2 amp strobe circuits (4 amps total) Supervised Audio Speaker outputs: 70V or 25V field selectable (all boosters must be either 70 V or 25 V) Expansion output (supervised, 24VDC at.5a in alarm condition used for connecting multiple boosters DC output (unsupervised for optional splitter power). Each speaker circuit (four for the KFSPB-320, two for the KFSPB-160, one for the KFSPB-80/4) can connect to speaker splitters Approvals & Compliance Approvals: UL 2572 for MNS, UL Standard 864, 9th edition, UL Standard 1711 OSHA 1910.165 and ADA Compliant 2

Mechanical Specifications: KFSPB-160, KFSPB-80/4: Dimensions: Weight: Finish: Door Lock: KFSPB-320: Dimensions: Weight: Finish: Door Lock: 21 H x 16 W x 6 D (wall mount) 36 lbs. (without batteries) Red exterior enclosure 211 key-lock 36 H x 24 W x 6 D (wall mount) 80 lbs. (without batteries) Red exterior enclosure 211 key-lock Technical Specifications: Powered by: Standby current draw: Alarm current draw: 120VAC, 3.8A, 60 Hz input KFSPMNS Models 240 VAC, 2.5A, 50-60 Hz 120mA per amplifier board 9 Amps per amplifier board KFSPB-80/4 and KFSPB-160 have one amplifier board KFSPB-320 has two amplifier boards System Frequency Response: Voice 400 Hz - 6.5 khz Signal to Noise Ratio: > 70 db Dynamic Range: > 65 db Total Harmonic Distortion: 2% 3

98026 KFSP40S 98527 KFSP40S-B 98537 KFSP40SE ORDERING INFORMATION Emergency Communication Panel, 40 Watt- 120VAC Single-Channel System, 40 Watts Audio Power, 2 Amps Strobe Power, Eight (8) Standard Messages, Red Enclosure. Requires two (2) 12V batteries (purchased separately). Batteries over 12AH require separate enclosure. Emergency Communication Panel, 40 Watt- 120VAC Single-Channel System, 40 Watts Audio Power, 2 Amps Strobe Power, Eight (8) Standard Messages, Black Enclosure. Requires two (2) 12V batteries (purchased separately). Batteries over 12AH require separate enclosure. Emergency Communication Panel, 40 Watt- 220VAC Single-Channel System, 40 Watts Audio Power, 2 Amps Strobe Power, Eight (8) Standard Messages, Red Enclosure. Requires two (2) batteries (purchased separately). Batteries over 12AH require separate enclosure. KCi # Model # ECS ACCESSORIES 98351 KFAM-SP40S- SMK Message Kit- after-market, standard eight (8) messages 98352 KFSP40S-PMK Message Kit- after-market, programmed eight (8) messages 98353 KFAM-SP40S- NBT 98531 KFSPB-160 98533 KFSPB-160E 98541 KFSPB-160E-B 98027 KFSPB-80/4-R 98542 SPB-80/4E-B 98551 KFSPB-320-B Narrowband Signal Tone Kit- after-market RED, Audio Power Booster, 160 Watt, 120VAC- 120VAC Supervised Audio Power Booster, Two (2) 80- Watt Circuits, Red Enclosure, Requires two (2) 12V batteries (purchased separately). Batteries over 12AH require separate enclosure. RED, Audio Power Booster, 160 Watt, 220VAC- 220VAC Supervised Audio Power Booster, Two (2) 80- Watt Circuits, Red Enclosure, Requires two (2) 12V batteries (purchased separately). Batteries over 12AH require separate enclosure. BLACK, Audio Power Booster w/strobe Power, 160 Watt, 220VAC- 120VAC Supervised Audio Power Booster, Two (2) 80-Watt Circuits, Four (4) Amps Strobe Power (2 Circuits), Black Enclosure, Requires two (2) 12V batteries (purchased separately). Batteries over 12AH require separate enclosure. RED, Audio Power Booster w/strobe Power, 80 Watt, 120VAC- 120VAC Supervised Audio Power Booster, One (1) 80-Watt Circuit, Four (4) Amps Strobe Power (2-2 Amp Circuits), Red Enclosure, Requires two (2) 12V batteries (purchased separately). Batteries over 12AH require separate enclosure. BLACK, Audio Power Booster w/strobe Power, 80 Watt, 220VAC- 220VAC Supervised Audio Power Booster, One (1) 80-Watt Circuit, Four (4) Amps Strobe Power (2-2 Amp Circuits), Black Enclosure, Requires two (2) 12V batteries (purchased separately). Batteries over 12AH require separate enclosure. BLACK, Audio Power Booster, 320 Watt, 120VAC-120VAC Supervised Audio Power Booster, Four (4) 80- Watt Circuits, Black Enclosure, Requires two (2) 12V batteries (purchased separately). Batteries over 12AH require separate enclosure. 98571 KFSP4Z-A/B Audio Splitter - two (2) zone Class A or four (4) zone Class B 98572 KFSPMB4Z Mounting Bracket- for 98571 98573 KFSPRM Remote Microphone- red plate 98574 KFSPRM-B Remote Microphone- black plate 98575 KFSP-COA C.O. Port Adapter 98576 KFSP4-RMX Remote Microphone Expansion Module- for connection of up to three (3) 98573 remote microphones 98577 KFSP4-APS Addressable Paging Splitter- for access to individual or multiple speaker zones via telephone, and control of selectable paging and background music 98578 KFSP4-TZC Telephone Zone Controller- auto programmable, provides telephone paging (all call or selected zones) 98579 KFTZC-USB Programming Cable- for telephone zone controller 98580 KFSP-SVC Supervised Volume Control- for telephone zone controller 98581 KPNACIM Notification Alarm Circuit Interface Module- converts fire alarm control panel NAC voltage output to appropriate signal for activation of emergency communication panel 98582 KFSP4-LOC-SB Local Operator Console- surface mount (can be mounted up to 2,000 feet away from emergency communication panel) 4

KCi # Model # ECS ACCESSORIES 98583 KFSP4-LOC-FB Local Operator Console- flush mount (can be mounted up to 2,000 feet away from emergency communication panel) 98584 KFSP4-LOC-KIT HVAC Emergency Cutoff Switch Kit- for local operator console 98585 KFEOLK End of Line Resistor Kit- 8 Resistors, UL Listed 98586 KFEOLK-EM End of Line Resistor Kit- 32 Resistors, UL Listed 74131 BC1R211 Battery Cabinet- (24-1/4"H x 24-1/4"W x 8-3/4"D), with 211 lock 74134 BC1R30 Battery Cabinet- (24-1/4"H x 24-1/4"W x 8-3/4"D), with CAT-30 lock 99960 BBS-211 Backup Battery System, includes Battery Cabinet with (2) 12v 55Ah Batteries, 211 lock 99961 BBS-30 Backup Battery System, includes Battery Cabinet with (2) 12v 55Ah Batteries, PK625/Cat 30 lock 98026-DTS Specification Data Sheet Kingfisher Company, inc., products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Kingfisher Company, inc., standard terms and conditions 5

Keypad for Voice Message Selection located inside SP40SD Microphone located inside SP40SD 6