four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Similar documents
(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

Conventional Fire Detection

Xenex Conventional Fire Detection & Alarm System

Intelligent Security & Fire Ltd

System 800 Addressable Fire Detection & Alarm System

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Operating instructions Vigilon panel and Network node Fire detection and alarm system

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Intelligent addressable fire alarm control panel

Consultant Specification AGILE Wireless Fire Detection System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Generic Commissioning Instructions

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

ACP10 & ACP50 Security Systems

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Addressable and Conventional Fire Protection

Fire Detection - Addressable

Fire detection and alarm

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

EFBW series - BiWire Ultra control panel

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

intelligent fire alarm ID60series panels

Fire detection and alarm system Operating instructions

The complete conventional fire warning system

Installation, Operating and Maintenance Manual

MINERVA MZX125 Digital Addressable Fire Detection System

ID50series. intelligent fire alarm panels

Fire detection and alarm system Installation instructions

Protec. Protec Algo-Tec TM 6400 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

MINERVA MX. 800 Series Ancillary Equipment

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

ZXSe Range Data Sheet

The new detector from Rafiki

Fire Signalling. Signalling Solutions

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

Solution F2. Fire Alarm Control Panels one step ahead.

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

intelligent solutions

Intelligent Security & Fire Ltd

DCS-100. intelligent damper control & monitoring system

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

HART XL High Sensitivity Smoke Detection

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Interface Modules for SENTRI

Evolution Analogue Addressable Fire System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MINERVA MZX125. Digital Addressable Fire Detection System

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

Conventional Leaflets

HART XL High Sensitivity Smoke Detection

Control Panel User Guide

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Industries. As a premier global manufacturing company, we believe that great brands are

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Excel-EN Conventional Fire Control Panel

The supplier and installer of the system should be approved by the local civil defence authority.

Fire Product Catalog

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Analogue addressable devices

EMERGENCY ASSISTANCE ALARMS

4 wire conventional alarm system

Control Panel User Guide

IGD.CO.UK

Fire Signalling. Signalling Solutions

Data and Installation Instructions

Addressable Fire Alarm Control Panel

IQ8Control C Fire Alarm Panel

Opal TM AV Devices. Data Sheet. Benefits

The EN54 Part 2, 4 and 13 Fire System

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Reliably Advanced Extinguishing Control

LaserFOCUS VLF-250 Engineering Specification

Conventional Fire Alarm System 2014 V1.2

System ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM. Applications Manual AND ALARM. Issue 1 March System Design. Appendices.

TrueAlarm Fire Alarm Controls

Apollo Accreditation. Need further information? Visit

2004 AUSTRALIAN STANDARDS UPDATE

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Reliably Advanced Extinguishing Control

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Sita200plus. 200detectors. Single loop analogue addressable System

ID3000 intelligent. fire alarm panel

Vigilant MX4428 Fire Alarm System

SUPREMATouch. Modular Fire & Gas Detection System

Product Data Sheet. Remote Terminals. Features:

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

E3 Series Broadband System

Transcription:

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2 core loop. No separate sounder or repeater panel circuits are required. Save on Cable Costs Cable runs are shorter. 2 core costs less than 4 core. Overall cable costs are normally 30% less than other systems. Customise your Fire Plans Evacuating public areas or production lines is disruptive and costly. Vigilon s powerful software gives you flexibility. Areas throughout the building can be sectored to evacuate, alert, or configured with pre-set delays. Match Sensors to the Risk Vigilon sensors have a wide range of sensitivities. Configuring the sensor is one of the most effective ways of reducing false alarms. Combine Sensors and Sounders Vigilon s combined sensor sounders reduce hassle and save cost. Integral sounders are ideal for boosting sound levels without additional wiring. Loop Powered Sounder/Strobe Loop powered sounder/strobes saves on cabling and interface costs. Reduce Ongoing Costs All sensors require regular cleaning from airborne contamination. Often the complete sensor will need replacing. Gent are the only manufacturer with disposable chamber elements to save maintenance costs. Clear Information 64 character display means the user is not limited in describing the position or nature of an emergency. A clear backlit LCD display reduces confusion and speeds response. 4/3

four ANALOGUE FIRE DETECTION VIGILON COMPACT ARCHITECTURE Upto 4 LCD Repeat Indicators RS 485 See back page for connection details MCP System Sounder Sounder/ Strobe Vigilon Compact Control panel A4 Mimic Display Door Release or Plant Shutdown Interface Interface Sprinkler Activated Max Loop Length 1000M Sensor/ Sounder Beam Transmitter Beam Receiver System Sounder Functional Repeat panel 4/4 MCP

ANALOGUE FIRE DETECTION VIGILON COMPACT SYSTEM Introducing Vigilon Compact the latest addition to the well respected Gent Vigilon family of Analogue Fire detection and alarm systems. Vigilon Compact 1-2 loop panels offer small to medium sized building owners the unique system functionality of Vigilon with the very best in control panel aesthetics stainless steel door options are available to provide a discreet and luxurious feel in upmarket office environments. The introduction of innovative design features into this panel means that the wall space needed to mount the panel is now 60% smaller than a standard Vigilon installation. Vigilon Compact analogue addressable panels fully comply with EN54:Parts 2 & 4 and can be specified with 1 or 2 detection loops, each capable of accomodating 200 devices comprising of repeat panels, interfaces, manual call points, sensors and sounders. Fully compatible with Gent s innovative new S-cubed alarm devices (offering sound, speech or strobe effects in combination), Vigilon Compact also offers the familiar advantages of combined sensor-sounders and loop powered beam detection with integral short circuit isolators fitted into every loop device. Additional features Vigilon s powerful software allows the fire alarm system to be configured to meet the fire alarm needs of the building. Combining the proven reliability of the Vigilon range of sensors, true Analogue sensing false alarms are kept to a minimum. If alarm sound levels need increasing then simply replacing a sensor with a sensor/sounder can boost alarm sound levels saving costly additional wiring. Wiring Details - LCD Repeat Panel (indication only) Monitored Battery Backed 24V PSU Max Cable Length 1000M RS 485 24Vd.c. Vigilon Compact Control panel One LCD repeat panel can be powered from the Control panel, additional repeat indicators must be powered from an additional power supply. The communication link to the panel is monitored, so if power to the repeat indicators fails the fault will be reported at the Control panel. four 4/5

four ANALOGUE FIRE DETECTION VIGILON COMPACT CONTROL PANEL A one to two loop panel accommodating up to 200 devices per loop. LCD display allows clear indication of fire or fault location. Site specific fire plans can be programmed to meet the evacuation needs of the building. Vigilon Compact Control Panel Technical Specification Type Control panel Loop Capacity 200 Ingress Protection Approx Weight IP31 10 Kg Operating Temperature 0ºC 40ºC Relevant Standards EN54 Pt 2 & 4 Batteries Battery Standby 2 x 12V @ 12AH 24 Hours + 30 minutes alarm Supply Voltage 216V 253V 50Hz ORDER CODES Control Panel COMPACT-24 LCD Repeat COMPACT-RPT panel Flush fixing COMPACT-FLUSH frame Additional COMPACT-LPC Loop card Optical only COMPACT-O sensor Power Consumption Cable Entry Auxiliary Contacts Sounder Circuits Monitored input Communication ports Approvals Dimensions (mm) 140 W Top and rear knockins Programmable to activate on Fire, Fault or Disablement (1 x SPCO 1 x DPCO) 2 circuits @ 250mA each 1 input which is programmable to perform a logical action via a command build 2 x RS485, 1 x RS323 selectable functions LPCB Applied for Stainless Steel Options: Stainless Steel VIG-RPT-DOOR-SS door Stainless steel COMPACT-FLUSH-SS flush frame 338 4/6 403 136

Technical Specification Type Max No per Loops Loop Capacity Ingress Protection Supply Voltage Power Consumption Approx Weight ANALOGUE FIRE DETECTION LCD REPEAT PANEL LCD Repeat Panel (Indication Only) N/A N/A IP31 21 30V DC Approx 30 ma 0.75 Kg Ambient Temperature 0ºC 50ºC Communication ports Cable Entry Approvals Dimensions (mm) 177 206 Vigilon Compact Repeat Panel 1x RS485 to communicate with the main control panel Top and rear knockins N/A 49 The LCD repeat panel indicates Fire, Fault and Disablement information either directly as events occur or by accessing the logs via dedicated keys. A maximum of 4 Repeat Panels can be connected to a Vigilon Compact control panel. ORDER CODES LCD Repeat COMPACT-RPT panel four 4/7

3/1

four Vigilon Analogue Addressable Fire Detection & Alarm System 4/9

ANALOGUE FIRE DETECTION VIGILON FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2 core loop. No separate sounder or repeater panel circuits are required. Save on Cable Costs Cable runs are shorter. 2 core costs less than 4 core. Overall cable costs are normally 30% less than other systems. NETWORK Create Seamless Networks Connect up to 50 panels together and retain control on large or complex sites. Also, new buildings or extensions are easily accommodated onto the existing system. Customise your Fire Plans Evacuating public areas or production lines is disruptive and costly. Vigilon s powerful software gives you flexibility. Areas throughout the network can be sectored to evacuate, alert, or configured with pre-set delays. Match Sensors to the Risk Vigilon sensors have a wide range of sensitivities. Configuring the sensor is one of the most effective ways of reducing false alarms. Combine Sensors and Sounders Vigilon s combined sensor sounders reduce hassle and save cost. Integral sounders are ideal for boosting sound levels without additional wiring. Loop Powered Sounder/Strobe Loop powered sounder/strobes saves on cabling and interface costs. Reduce Ongoing Costs All sensors require regular cleaning from airborne contamination. Often the complete sensor will need replacing. Gent are the only manufacturer with disposable chamber elements to save maintenance costs. Clear Information 64 character display means the user is not limited in describing the position or nature of an emergency. A clear backlit LCD display reduces confusion and speeds response. Integrated Voice and Graphics Systems Vigilon may be integrated with Gent Orator voice evacuation system. Or connected to Supervisor, a graphic display for single point control and monitoring. 4/11

four ANALOGUE FIRE DETECTION SYSTEM ARCHITECTURE Repeat Panel Spur Manual Call Point T-breaker Alarm Sounder Max Loop Length 1000m Interface Units Sprinkler Door Release or Plant Shutdown Sensor Sounder Beam Transmitter Beam Receiver Loop 1 Manned Centre Link to Fire Station Sounder Strobe Loop 2 Loop 3 Loop 4 Up to 50 Panels using Domain Bridge Loop 1 Loop 2 Loop 3 Secure Network up to 31 Panels Node DOMAIN BRIDGE Via Node to Trend Building Management Network Loop 2 Loop 3 Loop 4 4/12 Supervisor Sensor Loop 1 Orator Up to 200 Devices per Loop A4 Mimic Panel Vigilon architecture is extremely flexible, from single loop panels up to 50 panels in a system (Maximum number of 31 panels per secure network).

ANALOGUE FIRE DETECTION VIGILON SYSTEM The feature-packed Vigilon Analogue Addressable Fire Detection and Alarm System is the successor to the company s top-end System 3400 which has been the undisputed market leader for the past decade. Vigilon offers new market standards in system flexibility and control panel aesthetics, along with a degree of system sophistication that has never previously been available. It incorporates a host of features designed to make it the simplest system fault occur a detailed explanation is shown and the user can at any time navigate through the faults history. Vigilon control panels, repeat and mimic panels can be used to replace System 3400 panels, and the Vigilon system can be used to extend an existing System 3400 installation. It employs the same proven wiring architecture as System 3400, sharing its ability to offer building occupiers unrivalled performance, free from disruptive and costly false alarms. system to install, configure and use. Vigilon incorporates a range of 1-4 loop panels can accommodate up to multi-criteria sensors which contain 200 devices including, repeats, interfaces, call points, sensors and sounders on each loop. Vigilon also represents an entirely new concept in control panel displays. It has an innovative 16-line by 40-character display and a keyboard that is simple to use. various sensing elements and have a unique disposable chamber that simplifies and reduces the cost of maintenance. These are just a few of the features of Vigilon, read on and learn more about this leader in the protection of life and property from fire. As well as providing the user with clear comprehensive information in the event of a fire, Vigilon additionally provides an entire historic log of the system s management information. Should a Termination Plate Integral Sounder Semi-Recess Mount Kit Multi-Criteria Sensor Disposable Chamber Dust Cover Exploded illustration of a Vigilon sensor to show the unique components. four 4/13

four ANALOGUE FIRE DETECTION VIGILON CONTROL PANEL A one to four loop panel accommodating up to 200 devices per loop. Up to 31 panels may be connected in a secure network. LCD display allows clear indication of fire or fault location. Site specific fire plans can be programmed to meet the evacuation needs of the building. Vigilon Control Panel Technical Specification Type Control panel Max No of Loops 4 Loop Capacity 200 Batteries 4 x 12V @ 12AH Battery Standby 24 hours standby + 30 minutes alarm upgradeable to 72 hours Approx Weight 16.2 Kg Ambient Temperature 0 C to 45 C Relevant Standard BS 5839: Part 4 + EN54 Part 2 + 4 Cable Entry Top and rear knockins Approvals LPC approval to BS 5839: Part 4 ORDER CODES EN 54 Control Panels (For BS 5839 versions add the suffix -V3+ e.g. VIG1-NET-V3+) 1 Loop VIG1 2 Loop VIG2 3 Loop VIG3 4 Loop VIG4 1 Loop, Networkable VIG1-NET 2 Loop, Networkable VIG2-NET 3 Loop, Networkable VIG3-NET 4 Loop, Networkable VIG4-NET Note: Control panels require a first fix, VIG-1ST-FIX Dimensions (mm) A B C Control 408 539 151 Panel Battery Box 382 309 112 A 4/14 B C

Technical Specification Type ANALOGUE FIRE DETECTION REPEAT PANEL Repeat panel Max No per Loops 32 Loop Capacity Batteries N/A 1 x 12V @ 6AH Battery Standby 24 hours standby + 30 minutes alarm upgradeable to 72 hours Approx Weight 6.2 Kg Ambient Temperature 0 C to 45 C Relevant Standard BS 5839: Part 4 + EN54 Part 2 + 4 Cable Entry Top and rear knockins Approvals LPC approval to BS 5839: Part 4 Dimensions (mm) 403 338 101 Vigilon Repeat Panel A repeat panel repeats all information provided to the main control panel and provides mains control functions. The repeat panel is connected directly to the loop but requires a mains supply to run its battery backed power supply. ORDER CODES Repeat Panel VIG-RPT NOTE: Repeat panels require a VIG-RPT-1ST-FIX first fix four 4/15

four ANALOGUE FIRE DETECTION MIMIC PANELS The A2 and A4 Mimic Panels provide a pictorial representation of the building s layout allowing extremely quick indication of fire location. The mimic panels consist of an array of programmable LED s onto which a CAD drawing of the site is overlaid. Alternatively a zonal overlay kit may be used. Overlays are easily updated if site details alter. A2 Mimic Technical Specification Type A2 Mimic A4 Mimic Max Quantity per Loop 32 32 Batteries 12V @ 6AH 12V @ 6AH Battery Standby 24 hours or 72 hours (requires 2 x 12V 6Ah batteries) Approx Weight 18 Kg Display 2.3 Kg, Control panel 10.4 Kg Ambient Temperature 0 C to 45 C Relevant Standard BS 5839: Part 4 + EN54: Part 2 + 4 Cable Entry Top conduit knockins Rear A4 mimic display Load Factor 3 3 ORDER CODES A4 Mimic Panel A4 Zonal Mimic A2 Mimic Panel A2 Zonal Mimic VIG-MIM-A4 VIG-ZONE-A4 VIG-MIM VIG-ZONE Dimensions (mm) A B C A2 Mimic 650 830 90 A4 Mimic 276 330 73 Display C 4/16 A B

Technical Specification ANALOGUE FIRE DETECTION SENSORS Type Heat Optical/Heat Max Quantity per Loop 200 200 Approx Weight 0.175 Kg 0.175 Kg Ingress Protection IP42 IP20 Relevant Standard BS 5445: Parts 5 & 7 Ambient Temperature 0 C to 45 C 0 C to 50 C (If heat used 0 to 45 C) Device Load Factor 1 1 Approvals Note: All Vigilon sensors require a terminal plate, 34700 Dimensions (mm) 64 LPCB 86 34710 Sensors Vigilon has a range of low profile addressable devices to suit different applications. Heat Sensor - for steamy and dusty environments e.g. boiler rooms kitchens and laundries. Optical/Heat - detects smoke from a slow burning fire and/ or heat from an intense fire producing little smoke. All sensors (except beam) are supplied with a dust cover to prevent contamination during installation. ORDER CODES Heat 34720 Optical / Heat 34710 four 4/17

four ANALOGUE FIRE DETECTION BEAM SENSORS Beam sensors are suitable for large open areas where installation of single point detectors may be difficult or uneconomical. These detectors come in pairs, one of which emits an infra-red beam, detected by the other unit. If the beam is broken by smoke, the sensor is triggered. This model employs True Analogue detection techniques whereby other interruptions, caused by people or shadows, will be discounted. Technical Specification Max. Quantity per Loop Approx Weight Ingress Protection 34740 Beam Sensor (Pair) 16 pairs 0.6Kg per pair IP42 Ambient Temperature 0ºC to 50ºC Relevant Standards BS 5839: Part 5 Beam Length Mounting Height 2-100m 25-40m Device Load Factor 5 Approvals LPCB ORDER CODES Beam Sensor (Pair) 34740 Brackets required (2 per pair) Dimensions (mm) Angle bracket 34741-01 Angle bracket IP55 34741-90 Parallel bracket 34741-03 106 50 4/18

ANALOGUE FIRE DETECTION DUCT SMOKE SENSORS 34760 Duct Detector Technical Specification Type Duct smoke detector Max Quantity per Loop 200 ( 50 if slave LEDs used ) Approx Weight 4.6 Kg Ambient Temperature 0 C to 55 C Ingress Protection IP55 Relevant Standard N/A Duct Air Velocity 1 to 10 m/sc Device Load Factor 2 ( 1 for slave LEDs ) Dimensions (mm) 100 85 145 165 An optical smoke sensor specifically designed for use in ventilation ducting. Two 20mm probes sample the air in the duct for smoke. Detector housing is mounted externally to the duct. This device can trigger the shut-down of an air-conditioning or ventilation plant to prevent the spread of smoke. A slave LED is included with the device. ORDER CODES Duct Detector 34760 c/w slave LED four 4/19

four ANALOGUE FIRE DETECTION S 3 ALARM DEVICES Very low power consumption means more sounders per loop e.g 200 system sounders per loop compared to 40 The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power The strobe element of the sounders is fully monitored for circuit failures The sounder tones are programmed in exactly the same way as the existing Vigilon sounders Loop powered voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard By using the bell sound in the voice sounder it is possible to have a loop powered bell The sound producing element in the voice sounders is monitored every hour using a VLF tone Voice and Tone mode can be freely mixed within the same sounder All messages and strobe signals are synchronised across loops in the same control panel A backwards compatible version of the system sounder is available for replacement or expansion to existing systems, avoiding the need to upgrade panel software The HandiLink remote control makes it much easier to adjust the sounders in situ Products incorporate innovative design features for which multiple patents are pending The S-cubed range of alarm sounders incorporate sound speech and strobe effects all in one range of alarm devices. The range offers all variants in the choice of 2 colours red or white with either a shallow base version sealed to IP31 or a deep base version sealed to IP65. All the low profile sounders have the option of an integral strobe which is completely loop powered. With the introduction of voice enhanced sounders into the Vigilon range we now have the option of having a S-cubed loop powered bell sound for the first time as well as standard speech messages. As an aid to commissioning there is the option to use the HandiLink IR remote control to turn on individual sounders and adjust the volume remotely. This means physical access is not required to make this adjustment and is only active during the commissioning process. Password access at the control panel is required to enable this feature so it is not possible to make this adjustment accidentally or maliciously. Technical Specification - 1.0 Tone and Voice Sounders Type System Sounder Low Profile Standard Voice Inc Bell Standard Voice Inc Bell Tone Enhanced Sound Tone Enhanced Sound Max Quantity per Loop 200 200 70 200 200 70 Device Load Factor 5 5 13 5 5 13 Ingress Protection IP65C with Deep Base IP31C with Shallow Base Approx Weight 0.3Kg 0.3Kg 0.3Kg 0.3Kg Operating Temperature -10ºC to -10ºC to -10ºC to -10ºC to 50ºC 50ºC 50ºC 50ºC Relevant Standards EN54: Pt 3 EN54: Pt 3 EN54: Pt 3 EN54: Pt 3 (Sounder only) Sound Output at 1m 103 dba 103 dba 100 dba 100 dba ± 2dBA ± 2dBA ± 2dBA ± 2dBA IR Control Operating 3m 3m 3m 3m Distance Approvals LPCB Applied for 4/20 Standard Voice Messages 1) Alert Message (female voice) "An incident has been reported in the building, please await further instructions" 2) Alarm Message 1 (female voice) "Attention please, this is an emergency please leave the building by the nearest available exit" 3) Alarm Message 2 (male voice) "This is a fire alarm! Please leave the building immediately by the nearest available exit" 4) Test Message (female Voice) "This is a test message, no action is required"

ANALOGUE FIRE DETECTION S 3 ALARM DEVICES With the remote control individual sounders can be turned on and the sounder volume adjusted remotely from up to 3m away. To maintain system security this feature is password protected at the control panel. Technical Specification - 1.1 Tone and Voice Sounders with Strobe Type Sounder/Strobe Voice Enhanced Strobe Only Sounder/Strobe Strobe Colour Strobe Colour Strobe Colour Red or White Red or Inc Bell White with Red or White Amber Amber Tone & without Amber bell tone Max Quantity per Loop 60 30 60 40 30 100 40 Device Load Factor 15 28 15 23 33 10 23 Ingress Protection IP65C with Deep Base IP31C with Shallow Base Approximate Weight 0.3Kg 0.3Kg 0.3Kg Operating Temperature -10ºC to 50ºC -10ºC to 50ºC -10ºC to 50ºC Relevant Standards EN54 Pt 3 EN54 Pt 3 EN54 Pt 3 (Sounder only) Sound Output at 1m 100 dba ± 2 dba 100 dba ± 2 dba 100 dba ± 2 dba Strobe Light Output Equivalent to a 3w Equivalent to a 3w Equivalent to a 3w Xenon Xenon Xenon Strobe Flash Rate Signal 1 0.5Hz Signal 1 0.5Hz Signal 1 0.5Hz Signal 2 & 3 1.0Hz Signal 2 & 3 1.0Hz Signal 2 & 3 1.0Hz IR Control Operating 3m 3m 3m Distance Approvals LPCB applied for 1) When using the bell sound with voice enhanced sounders refer to the "Inc Bell Tone" column for the loop loading data. 2) To use the new range of Sounders the panel software (main & repeat) may need to be upgraded. LOW PROFILE SOUNDER IP31 112 75 112 112 IP65 112 90 SYSTEM SOUNDER IP65 121 112 110 112 Order Codes IP65 System Sounders S2IP-SN-R Sounder Red S2IP-SN-W Sounder White S2IP-SN-W3 Backwards compatible Sounder White S2IP-SN-R3 Backwards compatible Sounder Red S2IP-VO-R Voice Sounder Red S2IP-VO-W Voice Sounder White IP31 Low Profile Sounders S3-SN-ST-RR Sounder/Strobe Red S3-SN-ST-WR Sounder/Strobe White S3-SN-R Sounder Red S3-SN-W Sounder White S3-VO-ST-RR Voice Sounder/Strobe Red S3-VO-ST-WR Voice Sounder/Strobe White S3-VO-R Voice Sounder Red S3-VO-W Voice Sounder White IP65 Low Profile Sounders S3IP-SN-ST-RR Sounder/Strobe Red S3IP-SN-ST-WR Sounder/Strobe White S3IP-SN-ST-RW Sounder/Strobe Red body White lens S3IP-SN-ST-WA Sounder/Strobe White body Amber lens S3IP-SN-R Sounder Red S3IP-SN-W Sounder White S3IP-VO-ST-RR Voice Sounder/Strobe Red S3IP-VO-ST-WR Voice Sounder/Strobe White S3IP-VO-R Voice Sounder Red S3IP-VO-W Voice Sounder White IP65 Loop Powered Strobes S2IP-ST-RR Strobe Red body/red lens S2IP-ST-WR Strobe White body/red lens S2IP-ST-WA Strobe White body/amber lens S2IP-ST-RW Strobe Red body/white lens Remote Control S3-CONTROL HandiLink IR Remote Control four 4/21

four ANALOGUE FIRE DETECTION SENSOR SOUNDERS Repeat Sounder Repeats adjacent sounder operations. Ideal for en suite shower applications in hotels. Optical Heat Sensor Sounder Combines optical heat detection with an 85dBA sounder. Heat Sensor Sounder Combines heat detection with an 85dBA sounder. 34770 Optical/Heat Sounder Technical Specification Type Repeat Optical Heat Heat Sensor Sounder Sensor Sounder Sounder Max. Quantity per Loop 125 125 125 Approx. Weight 0.6Kg 0.6Kg 0.6Kg Ambient Temperature 0 C to 50ºC Ingress Protection IP30 IP20 IP20 Relevant Standards BS 5839: Part 1 Sound Output at 1m 85dBA 85dBA 85dBA Device Load Factor 8 8 8 Approvals - LPCB LPCB ORDER CODES Optical Heat Sensor 34770 Sounder Heat Sensor Sounder 34780 Repeat Sounder 34777 Dimensions (mm) 86 4/22 64

ANALOGUE FIRE DETECTION MANUAL CALL POINTS four An addressable call point with a response time less than 1 second. Versions available include: - IP55 rated - Lift up covers - Keyswitch - LPCB applied for 34800 Call Point Technical Specification Max Quantity per Loop 200 Ambient Temperature 0 C to 50 C Ingress Protection Standard IP40, Special IP55 Relevant Standard EN54 Part 11 Approx Weight 0.77 Kg, (IP55-3.5 Kg) Device Load Factor 1 Dimensions (mm) 87 ORDER CODES Call Point 34800-EN Key Switch Version 34807 Call Point with Cover 34842-EN IP55 Call Point 34812-EN IP55 Call Point 34852-EN with Cover Flush Fixing Plate 19289-01 Pack of 10 Spare 14112-09EN 87 55 4/23

four ANALOGUE FIRE DETECTION SENSOR ANCILLARIES T - Breaker Used to provide a spur from the addressable loop. Slave LED Located on the addressable loop, will mimic the LED of the device it is connected to. Slave Relay Located on the addressable loop, it will operate when the sensor it is connected to detects a fire condition. 34701 T-Breaker Technical Specification Type T-Breaker Slave LED Slave Relay Max Quantity per Loop 200 50 50 Approx Weight 0.35Kg 0.34Kg 0.36Kg Ambient Temperature 0 C to 50 C 0 C to 50 C 0 C to 50 C Ingress Protection IP40 IP40 IP40 Device Load Factor 1 1 1 ORDER CODES T-Breaker 34701 Slave LED 34702 Slave Relay 34703 Dimensions (mm) 86 48 4/24

Technical Specification ANALOGUE FIRE DETECTION INTERFACES Type Mains Loop Zone Module Single Channel Max Quantity per Loop 8 30 100 100 Approx Weight 8.6 Kg 2.4 Kg 0.7 Kg 0.7 Kg Ambient Temperature 0 C to 45 C Ingress Protection IP44 IP40 IP40 IP40 Voltage 230V a.c. Loop powered Loop powered Loop powered Device Load factor 8 2 10 10 No. Channels 4 4 1 1 Input Channels Fire Fire 2 wire for Fire Fault Fault conventional Fault MCP fire Non-fire event zone Non-fire event OEM detectors circuits Note: Loop powered interfaces require line modules for each single channel input or output. Dimensions (mm) A B C Mains & Loop Powered Interfaces A B C Mains 305 504 98 Loop 261 270 60 Zone 125 204 50 Module Single 125 204 50 Channel Interfaces are used to link the fire alarm system to other plant management devices such as sprinklers and security systems. They can also be used to link to a zone of conventional detectors or non Gent manufactured devices. Interfaces are either powered from the loop or require a separate mains supply. The mains power version has its own battery backup. ORDER CODES Mains Powered Interface 34440 Loop Powered Interface 34450 Loop Powered Zone 34410 Module Single Channel Interface 34415 Line Modules 19245-05 four 4/25

four ANALOGUE FIRE DETECTION SECURE NETWORKS A secure network is used to interconnect a number of control panels and allows fire and other information to be passed between panels. It also allows an operator at one panel to control other control panels on the network. The secure network comprises a cable loop with isolation circuits at each panel. Networks are powered from the control panels and therefore will continue to operate in the case of a mains supply failure. Technical Specification GENT SECURE NETWORK Connectable Equipment Mains Input Voltage Max. Number of Nodes Max. Distance between Nodes Network terminal node, 4 or 8 loop control panel 230V a.c. 31 control panels and terminal nodes 800-1200m dependant on cable Data Cables Belden No 9729 Fire Resistant Cables 4/26 MICC, RADOX FR Controlling the Network from a 13505 Terminal Node The terminal node is useful in applications where operators need to be able to monitor and control a fire alarm system of one or more control panels from a remote location. The terminal node provides global display and control facilities in a similar way to Vigilon, but for the entire network. VIGILON CONTROL PANEL WITH SENSORS & SOUNDERS VIGILON CONTROL PANEL WITH SENSORS & SOUNDERS GENT SECURE NETWORK GATEHOUSE WITH TERMINAL NODE ( PANEL ONLY)

ANALOGUE FIRE DETECTION NOTES four 4/27