FBII Security System. Programming Guide. Version 2.X. N9938PRV3 4/04 Rev. A

Similar documents
FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

First Alert 1200C Installer Notes M. Leuck

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

VISTA-100 Commercial Fire & Burglary Partitioned System

Property of Monitronics Inc

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Control/Communicator Installation Manual

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

CC488. Quick Reference Guide Solution Ultima 880

GEM-P800 Programming Instructions

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

VISTA-20PMT. Programming Guide. This control is a certified SIA-compliant control that meets SIA specifications for False Alarm Reduction.

CC408. Quick Reference Guide Solution 880

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Installation Instructions

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Property of Monitronics Inc

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

FBII Security System. Installation and Setup Guide. Version 2.0. N9938V4 8/06 Rev. A

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

2000 Series. Program Entry Guide. Control Panels

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Radionics D4112 Program Sheet

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

NetworX Series NX-4V2 Control Panel Installation and Startup

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Series. NX-4-EUR Control Panel. Installation manual

VISTA-128FB. Quick Start Guide. Commercial Fire & Burglary Partitioned Security System. with Scheduling.

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

System Programming Guide

USER GUIDE HARDWIRED CONTROL PANELS

INSTALLATION MANUAL & PROGRAM RECORD SHEET

Programming Worksheets

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

ADEMCO CONTACT ID REPORTING (revised )

Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN

Control/Communicator

4-PGM Expansion Module

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

PROGRAMMING INSTRUCTIONS

Installation Instructions

8-zone Expansion Module

RE6100 Series Helix Security and Automation Platform

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Contact ID as of 2/2/2015

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

SENTROL ZX400/ZX410. Security System Control. Programming

Contact ID as of 11/28/2018

LYNX Touch Security System

Quick Programmer s Manual

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

System Introduction. 1.1 Specifications S E C T I O N 1

PROGRAMMING INSTRUCTIONS

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

/10 Rev A

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

CHEAT SHEET: SPECTRA V2.1

USER GUIDE HARDWIRED CONTROL PANELS

ADEMCO VISTA-48 SERIES

USER GUIDE HARDWIRED CONTROL PANELS

Training Manual Multi-Language with Wireless

NX-4V2 Control Panel Installation Instructions

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

ADEMCO LYNX XL SERIES Security System

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

ADEMCO VISTA-12A ADEMCO VISTA-12E

/<1; 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH N8889V1 10/98 OFF AWAY STAY AUX

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

Type Report Report Date: 1/21/2015

GEM-P800. Control Panel/Communicator. Installation Instructions

AXI LED USER MANUAL (REV. 1.0)

Technical Manuals Online! - Keypad Programming. Basic Programming

Solution 862 Installation Manual ISSUE 1.30

Summit 3208GLD USER MANUAL. Electronics Line

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

LYNXR-2 Series Security System

9x5x QUICK REFERENCE PROGRAMMING GUIDE

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

Transcription:

FBII Security System OMNI -848 OMNI -848EU Version 2.X Programming Guide N9938PRV3 4/04 Rev. A

CONTENTS INSTALLER SUBMODE 1: SYSTEM OPTIONS... 4 Central Station Phone Numbers... 4 Pager Phone Numbers... 4 Central Station Account Numbers... 4 Report Options... 6 System Options... 6 Arming Options... 6 Sound Options... 6 Display Options... 6 Event Log Options... 6 Bell Timeouts... 6 Exit/ Delays... 6 Dialer Delay... 6 Test Report Time... 6 Pager Options... 6 Keypad Tamper... 6 RF Jam... 6 Soft Key Options... 6 Auto-Arming Options... 6 Trigger/Relay Options... 7 Keypad Mapping... 7 Keyfob Button Functions... 8 Relay/Trigger Timeout... 8 Open/Close Report Disables... 8 INSTALLER SUBMODE 2: ZONES AND REPORTING CODES... 9 Zone Types and Attributes... 9 Report Codes... 11 First RF Zone/First Doubled Zone... 11 Cross Zone Programming... 12 INSTALLER SUBMODE 3: WIRELESS TRANSMITTER PROGRAMMING... 13 Wireless Transmitter Enables and Serial Numbers...13 Keyfob Enables and Serial Numbers... 13 INSTALLER SUBMODE 4: ZONE DESCRIPTORS... 14 Zone Descriptors... 14 Partition Descriptors... 14 2

INSTALLER MODE 1 COMMANDS To Press Enter Installer Mode 1 [CODE] [ ] (installer s code) [1] (select submode number 1-4) Sub Modes: System Options (enter installer mode 1) [1] Zone Prog./Report Codes (enter installer mode 1) [2] Wireless Programming (enter installer mode 1) [3] Descriptor Programming (enter installer mode 1) [4] Enter data Go to next location in question [#] Go to next question appropriate key then [#] to accept entry [INSTANT] or [ ] (2-digit question no.) Go to another submode [ ] [BYPASS] (select desired submode number 1-4) Exit Program Mode [STAY] 3

INSTALLER MODE 1 (Programming Mode) SUBMODE 1 SUBMODE 1: SYSTEM OPTIONS Enter installer mode 1, then select submode 1. The display shows the following: Q#01 M1 Edit L:01 DATA: 234A System Default values are shown inside brackets. NOTE: When you enter Submode 1, question 01 is automatically displayed. To change or review the Installer Code (question 00), enter [#] + [0] + [0]. The Installer Code will be displayed. Q 00 Installer Code N/U N/U [246800AA] QUESTIONS 01-06 TELEPHONE and PAGER NUMBERS Enter the appropriate telephone numbers in Questions 1-6. Questions 1-3 support up to 20-digit numbers. Questions 4-6 support up to 16-digit numbers. Q 01 PRIMARY CS NUMBER [234A ] Q 02 SECONDARY CS No. [AAA ] Q 03 CALLBACK NUMBER [AAA ] Q 04 PARTITION 1 PAGER NUMBER [AAA ] Q 05 PARTITION 2 PAGER NUMBER [AAA ] Q 06 PARTITION 3 PAGER NUMBER [AAA ] QUESTIONS 07-14 ACCOUNT NUMBERS Enter the appropriate account numbers in Questions 7-14. Q 07 PART. 1 PRIMARY [1234] Q 11 PART. 3 PRIMARY [1333] Q 08 PART. 1 SECONDARY [2234] Q 12 PART. 3 SECONDARY [2333] Q 09 PART. 2 PRIMARY [1222] Q 13 COMM. PART. (4) PRIM. [1444] Q 10 PART. 2 SECONDARY [2222] Q 14 COMM. PART. (4) SEC. [2444] QUESTIONS 15-36 REPORTING and SYSTEM OPTIONS For detailed explanations, refer to the programming tables in the Installation Instructions when making the following entries. You can also calculate the value of an entry by adding the binary values of the desired options in each location. The values are, from top to bottom, 1, 2, 4, 8. Enter 0 if none of the options are desired. Enter A-F for values of 10-15 respectively. For Questions with locations containing more than 4 options, charts listing them are provided (these options are indicated with an asterisk). Q 15 CS FORMAT/RCVR TYPE [E0E0] L1 L2 L3 L4 CS1 CS2 Format Rcvr Format Rcvr (see chart below for values to enter) L1/L3 CS REPORTING TRANS L2/L4 FORMAT PULSE SPEED HANDSHAKE TYPICAL CS RECEIVER FORMAT TYPE 10 PPS 20 PPS 40 PPS 1400 HZ 2300 HZ Parity 0 3x1 Standard PULSE 0 FBII, ADEMCO, SILENT KNIGHT 1 4x1 Standard PULSE 1 FBII, ADEMCO, RADIONICS 2 3x1 Extended PULSE 2 FBII 3 4x1 Extended PULSE 4 FBII, SILENT KNIGHT 4 3x1 Partial Extended PULSE 5 FBII, RADIONICS 5 4x1 Partial Extended PULSE 6 FBII, RADIONICS 6 3x2 PULSE 8 FBII 7 4x2 PULSE 9 FIXED DTMF FORMAT FBII, ADEMCO 8 FBII Superfast DTMF A FIXED DTMF FORMAT FBII, ADEMCO 9 ADEMCO 4x1 Express * DTMF E FIXED DTMF FORMAT FBII, ADEMCO A ADEMCO 4x2 Express * DTMF E ADEMCO Point ID * DTMF 4

Use the following charts when making entries for Questions 16, 17, 18, 24, 25, and 26. Q16, L1: Enter the L1 digit for the desired reporting options from the table below. L1 Report Type Report First to open Backup Dual Split Disabled Stay Bypass Last to close 0 1 2 3 4 5 6 8 9 A C D E Q 17, L4: Enter the digit for the desired options from the table below. L4 Send Test Report at Fixed Interval Don t Send Test Report if Event Occurs Disable Every hour 1 day Test Time Interval 7 27 days days 60 days 90 days 0 1 2 3 4 5 6 7 9 A B C D E 180 day Q 18, L3: Enter the L3 digit from the table below. L3 Supervision Time (hours) 1 3 9 12 Pager Attempts 0 1 2 3 0 Disabled 1 2 3 4 Disabled 5 6 7 8 Disabled 9 A B C Disabled D E F Q24, L4: Enter the L4 digit for the desired dialer delay from the table below. L4 Dialer Delay Seconds 0 15 1 20 2 25 3 30 4 40 5 50 6 60 7 75 8 90 9 105 A 120 B 150 C 180 D 210 E 240 F 255 Q 25/26: These questions define entry delays 1 and 2 for each partition. L1-L4 ENTRY DELAY SECONDS L1-L4 ENTRY DELAY SECONDS 0 1 8 75 1 5 9 90 2 10 A 105 3 15 B 120 4 20 C 150 5 30 D 180 6 45 E 210 7 60 F 240 5

Q 16 REPORT OPTIONS L1* L2 L3 L4 [07FF] Dial Type Restore Dial attmpts Restores report option supervsn (1-15) AC sends rstr report option tamper Low Bat sends rstr rpt stay byp RF low bat zone sends rstr FTO/LTC rstr follows loop Q 17 SYSTEM OPTIONS UL: L2 must be 0 or 2; L4 must be 3. [0020] L1 L2 L3 L4* no bell/dial n/a euro pulse test time interval fast zone 7/8 Relay enbl. tone/pulse dbl bal n/a user 6/4 digit RF enable bell sprvs. NOTE: The default value shown above (0020) applies to the OMNI- 848. The default value for the OMNI-848EU is 8420 Q 18 OTHER SYSTEM OPTIONS UL: L1 door strike option not evaluated by UL. [48C2] L1 L2 L3* L4 user online key tamp. pager attmpt swinger count duress (61-64) tamp reset pager attmpt (0-3) no code dr strike crystal RTC sprv time bat test 4/1s door (50-60) tone burst on sprv time delay if stay Q 19 ARMING OPTIONS UL: Do not use L2 bypass/exit error, [818F] L3 exit extends, L4 quick exit L1 L2 L3* L4 stay=stay arm w/fault disbl arm P1 quick arm fob autostay byp/exit err disbl arm P2 force arm inst=away no arm dwnld disbl arm P3 quick exit inst enbl no arm lo bat exit ext. quick bypass Q 20 SOUND OPTIONS UL: L4 must be F. L1 L2 L3 L4 fob ding thresh snd phone fail en. RF sprv bell ding thresh bell phn fail sndr RF lo bat disarm ding CS test ring phn fail bell sys lo bat fast ding invert bell bell cancel AC loss Q 21 DISPLAY OPTIONS [000F] UL: Do not enable L1 no AC loss (must display AC loss) [1100] L1 L2 L3 L4 armed byp time w/o code clock 24hr Language fault on entry daylight save day/mo (0=Eng, 1=Ital,) AC loss LED extinguish show time 2=Span, 3=Africa. Byp limit 3 disp. fob LB clock fail 4=Dutch, 5= Port) NOTE: The default value shown above (1100) applies to the OMNI- 848. The default value for the OMNI-848EU is 1130 Q 22 LOG OPTIONS _ x _ Q 23 BELLS/AC DELAY/RING CNT UL: L1 and L2 must be 2. L3 must be F. [5F18] L1* L2* L3* L4 burg Fire AC dial ring timeout timeout delay count (times 3min) (times 3 min) (times 15 min) (0-15, 0=disable) (0=random) Q 24 EXIT DELAY/DIALER DELAY [CCC0] P1 P2 P3 dial (P1-P3 =value times 10 min; see chart for dial delay) delay UL: L1-L3 must be 5. L4 dial delay must be 0. Q 25* ENTRY DELAY 1 [5555] UL: Q25/Q26 entry delay must be 6 (45 seconds) [3333] P1 P2 P3 P4 (see chart for values) Q 26* ENTRY DELAY 2 Q 27* TEST REPORT TIME [0300] Hours Minutes (00-23) (00-59) Q 28 PAGER OPTIONS L1 (part. 1) L2 (part. 2) L3 (part. 3) L4 [0000] zone alarm zone alarm zone alarm enbl. users page P1 zone trbl zone trbl zone trbl enbl. users page P2 open open open enbl. users page P3 close close close #58 follow-me Q 29 KEYPAD TAMP, ARM &RF JAM L1 L2 L3 L4 [0000] n/a keypad tamp no arm jam jam enbl tamp sound no arm super jam eu/us tamp bell no AC 2X jam sound jam bell Q 30 Not Used Q 31 SOFT KEYS FOR 1&3/7&9 1 & 3 Keys 7 & 9 Keys L1* L2 L3* L4 [0000] sound opt arm away sound opt arm away (chart below) arm stay (chart below) arm stay relay opt page trbl relay opt page trbl (chart below) (chart below) Q 32 SOFT KEYS FOR & # _x_ _x_ & # Keys not used L1* L2 L3 L4 [2000] sound opt arm away n/a n/a (chart below) arm stay n/a n/a relay opt page trbl n/a n/a (chart below) n/a n/a Q 33 AUTO ARM ENABLES L1 L2 L3 L4 [EFF0] by part/all open RF bat n/a UL: L1-L3 must be 0. [0000] #53 log close RF/kypd sprv n/a L1 (part. 1) L2 (part. 2) L3 (part. 3) L4 zone alarm sys events tamper n/a auto arm auto arm auto arm up & about part. 1 zone trbl key events bypass/unbyp n/a arm warn arm warn arm warn up & about part. 2 instant arm instant arm instant arm up & about part. 3 stay arm stay arm stay arm * Refer to the charts on the previous page (except Questions 31 & 32, see chart below). Q 31/32: For L1 and L3 make selections from the table below. Sounder Options Relay Options L1/L3 Silent Keypad Burg. Bell Temporal No Relay Mom. Seconds Mom. Minutes Toggle 0 1 2 3 4 5 6 7 8 9 A B C D E F 6

Q 34 AUTO ARM TIME PARTITION 1 [0000] Hours Minutes UL: Must be disabled. (00-23) (00-59) Q 35 AUTO ARM TIME PARTITION 2 [0000] Hours Minutes UL: Must be disabled. (00-23) (00-59) QUESTIONS 37-48 TRIGGER/RELAY TYPES For Questions 37-48, make entries from the table in the right column. Q 37 RELAY 1 and 2 TYPES [0000] Relay 1 Relay 2 Q 38 RELAY 3 and 4 TYPES [0000] Relay 3 Relay 4 Q 39 RELAY 5 and 6 TYPES [0000] Relay 5 Relay 6 Q 40 RELAY 7 and 8 TYPES [0000] Relay 7 Relay 8 Q 41 RELAY 9 and 10 TYPES [0000] Relay 9 Relay 10 Q 42 RELAY 11 and 12 TYPES [0000] Relay 11 Relay 12 Q 43 RELAY 13 and 14 TYPES [0000] Relay 13 Relay 14 Q 44 RELAY 15 and 16 TYPES [0000] Relay 15 Relay 16 Q 45 RELAY 17 and 18 TYPES [0000] Relay 17 Relay 18 Q 46 RELAY 19 and 20 TYPES [0000] Relay 19 Relay 20 Q 47 TRIGGER 1 and 2 TYPES [0000] Trigger 1 Trigger 2 Q 48 TRIGGER 3 and 4 TYPES [0000] Trigger 3 Trigger 4 Q 36 AUTO ARM TIME PARTITION 3 [0000] Hours Minutes UL: Must be disabled. (00-23) (00-59) RELAY TYPE Part. 1 Part. 2 Part. 3 Comm. Disabled 00 40 80 C0 Burg Bell no Bell Test 01 41 81 C1 Fire Bell no Bell Test 02 42 82 C2 Partition Armed 03 43 83 C3 Partition Ready 04 44 84 C4 In Delay 05 45 85 C5 In Exit Delay 06 46 86 C6 Armed Instant 07 47 87 C7 Armed Stay 08 48 88 C8 Sounder on/pulsing 09 49 89 C9 Chime 0A 4A 8A CA Line Seize (System) 0B N/A N/A N/A Phone Fail (System) 0C N/A N/A N/A AC Loss (System) 0D N/A N/A N/A Low Battery (System) 0E N/A N/A N/A 24Hr Zone in Trouble 0F 4F 8F CF 24 Hr Zone Alarmed 10 50 90 D0 Instant Zone Faulted 11 51 91 D1 Delay Zone Faulted 12 52 92 D2 Interior Zone Faulted 13 53 93 D3 Zone Tamper 14 54 94 D4 RF Low Bat. 15 55 95 D5 RF Supervision 16 56 96 D6 Comm. Fail (System) 17 N/A N/A N/A Key Tamper, mom. Sec 18 58 98 D8 Duress Code, mom. Sec 19 59 99 D9 Bell Strobe - Internal, No dings 1A 5A 9A DA Bell Strobe - External, with dings 1B 5B 9B DB Trig Zone, mom Minutes 1C 5C 9C DC Trig Zone, mom. Seconds 1D 5D 9D DD Door Strike, mom Seconds 1E 5E 9E DE Shock Reset (*) Seconds 1F 5F 9F DF CS Test Momentary Secs. 20 60 A0 E0 Alarm/Restore by partition 21 61 A1 E1 2 way voice, on after seize rel. 22 62 A2 E2 Momentary by Seconds (fob,soft) 23 63 A3 E3 Momentary Minutes (fob,soft) 24 64 A4 E4 Toggle (Keyfob, softkeys) 25 65 A5 E5 Follows Zn Loop, Trig=Zone 1-20 26 66 A6 E6 Follows Zn Loop, Trig=Zone 21-40 27 67 A7 E7 On zn alm, off clear alm mem 1-20 28 68 A8 E8 On zn alm, off clear alm mem 21-40 29 69 A9 E9 Zone alm/rest - Z 1-20 2A 6A AA EA Zone alm/rest - Z 21-40 2B 6B AB EB Sys Bell, Internal (no Dings) 2C 6C AC EC Sys Bell, External(with Dings) 2D 6D AD ED RF Jam 2E 6E AE EE Keypad Tamper 2F 6F AF EF 24 Hour Silent Zone 30 70 B0 F0 QUESTIONS 49-52 KEYPAD MAPPING The system automatically reads keypad addresses during initial installation. Questions 49-52 are shown for reference and/or programming after initial installation. NOTE: LCD = OMNI-LCD, OMNI-LCD-US, or XK7LC; Non-LCD = OMNI-KP, OMNI-KP-US, or XK108 Q 49 KEYPAD MAP for PART. 1 Q 51 KEYPAD MAP for PART. 3 L1 L2 L3 L4 [8000] L1 L2 L3 L4 [0000] LCD 5 LCD 1 non-lcd 5 non-lcd 1 LCD 5 LCD 1 non-lcd 5 non-lcd 1 LCD 6 LCD 2 non-lcd 6 non-lcd 2 LCD 6 LCD 2 non-lcd 6 non-lcd 2 LCD 7 LCD 3 non-lcd 7 non-lcd 3 LCD 7 LCD 3 non-lcd 7 non-lcd 3 LCD 8 LCD 4 non-lcd 8 non-lcd 4 LCD 8 LCD 4 non-lcd 8 non-lcd 4 Q 50 KEYPAD MAP for PART. 2 Q 52 KYPD MAP for COMM. PART. 4 L1 L2 L3 L4 [0000] L1 L2 L3 L4 [0000] LCD 5 LCD 1 non-lcd 5 non-lcd 1 LCD 5 LCD 1 non-lcd 5 non-lcd 1 LCD 6 LCD 2 non-lcd 6 non-lcd 2 LCD 6 LCD 2 non-lcd 6 non-lcd 2 LCD 7 LCD 3 non-lcd 7 non-lcd 3 LCD 7 LCD 3 non-lcd 7 non-lcd 3 LCD 8 LCD 4 non-lcd 8 non-lcd 4 LCD 8 LCD 4 non-lcd 8 non-lcd 4 7

QUESTIONS 54-69 KEYFOB BUTTON FUNCTIONS and USERS For Even Numbered Questions 54-68, make entries from the following table: L1-L4 Keyfob Function L1-L4 Keyfob Function 0 Disabled 6 Keypad fire 1 Disarm 7 keypad panic 2 Arm away 8 keypad aux. 3 Arm stay 9 relay type 23 (mom. seconds) 4 Arm instant A relay type 24 (mom. minutes) 5 Arm stay/instant B relay type 25 (toggle) For odd numbered Questions 55-69, enter primary arming partition 1-3 and 2-digit user no.. Make L2 entry from the following table: L2 Arming Partition 1 1 2 2 3 3 UL: Keyfobs not evaluated for UL installations. Q 54 KEYFOB 1 FUNCTIONS Q 62 KEYFOB 5 FUNCTIONS [4123] But 1 But 2 But 3 But 4 [4123] But 1 But 2 But 3 But 4 Q 55 KEYFOB 1 USER Q 63 KEYFOB 5 USER [0001] N/U arming User no. [0001] N/U arming User no. partition partition Q 56 KEYFOB 2 FUNCTIONS Q 64 KEYFOB 6 FUNCTIONS [4123] But 1 But 2 But 3 But 4 [4123] But 1 But 2 But 3 But 4 Q 57 KEYFOB 2 USER Q 65 KEYFOB 6 USER [0001] N/U arming User no. [0001] N/U arming User no. partition partition (01-64) Q 58 KEYFOB 3 FUNCTIONS Q 66 KEYFOB 7 FUNCTIONS [4123] But 1 But 2 But 3 But 4 [4123] But 1 But 2 But 3 But 4 Q 59 KEYFOB 3 USER Q 67 KEYFOB 7 USER [0001] N/U arming User no. [0001] N/U arming User no. partition partition Q 60 KEYFOB 4 FUNCTIONS Q 68 KEYFOB 8 FUNCTIONS [4123] But 1 But 2 But 3 But 4 [4123] But 1 But 2 But 3 But 4 Q 61 KEYFOB 4 USER Q 69 KEYFOB 8 USER [0001] N/U arming User no. [0001] N/U arming User no. partition partition QUESTIONS 70/71 RELAY/TRIGGER TIME for MOMENTARY OUTPUTS Enter 0-F (0-15) for each location in questions 70 and 71 (P1-P3 = partition 1 to partition 3 respectively). Q 70 RELAY/TRIG TIME MIN. Q 71 RELAY/TRIG TIME SECS. [0000] P1 P2 P3 Com. [0000] P1 P2 P3 Com. QUESTIONS 72-75 OPEN/CLOSE CENTRAL STATION REPORT DISABLES Enter 0-F (0-15) for each location in questions 72-75. Q 72 OP/CL DISABLE Users 1-16 Q 74 OP/CL DISABLE Users 33-48 [0000] 1 5 9 13 [0000] 33 37 41 45 2 6 10 14 34 38 42 46 3 7 11 15 35 39 43 47 4 8 12 16 36 40 44 48 Q 73 OP/CL DISABLE Users 17-32 Q 75 OP/CL DISABLE Users 49-64 [0000] 17 21 25 29 [0000] 49 53 57 61 18 22 26 30 50 54 58 62 19 23 27 31 51 55 59 63 20 24 28 32 52 56 60 64 8

SUBMODE 2: ZONE PROGRAMMING AND REPORT CODES SUBMODE 2 While in Installer Mode 1, press [ ] + [BYPASS], then select submode [2]. The display shows the following: Q#01 M2 Edit L:01 DATA: 2000 Zn/Cde QUESTIONS 01-48 ZONE TYPES AND ATTRIBUTES Use the following tables when programming zones. L1: Select entry from the following table: L1 L1 Zone Type Zone Type Controlled Types 24 Hour Types 0 disabled 8 keyswitch 1 instant 9 trigger zone 2 delay A trouble zone 3 delay 2 B alarm zone 4 interior C alarm/trouble 5 day zone E fire no verification F fire with verification L2: Select entry from the following table: L2 Partition Hardwire Loop Type Wireless Supervision 1 2 3 C EOL N/C N/O Supervise Tamper 0 1 2 3 4 5 6 7 8 9 A B L3: 0 = none; 1 = silent zone; 2 = swinger suppression zone; 3 = both silent zone and swinger suppression zone UL: L3 swinger suppression must be disabled. L4: Select entry from the following table: L4 Stay Auto-Stay Chime Dial Delay 0 1 2 3 4 5 6 7 8 9 A B C D E F Q 01 ZONE 1 (type/attributes) [2000] Zone Part./ silent/ stay/chime Q 02 ZONE 2 (type/attributes) [4000] Zone Part./ silent/ stay/chime Q 03 ZONE 3 (type/attributes) [1000] Zone Part./ silent/ stay/chime Q 04 ZONE 4 (type/attributes) [1000] Zone Part./ silent/ stay/chime Q 05 ZONE 5 (type/attributes) [1000] Zone Part./ silent/ stay/chime Q 06 ZONE 6 (type/attributes) 9 [1000] Zone Part./ silent/ stay/chime Q 07 ZONE 7 (type/attributes) [1000] Zone Part./ silent/ stay/chime Q 08 ZONE 8 (type/attributes) [1000] Zone Part./ silent/ stay/chime Q 09 ZONE 9 (type/attributes) Q 10 ZONE 10 (type/attributes) Q 11 ZONE 11 (type/attributes)

Q 12 ZONE 12 (type/attributes) Q 13 ZONE 13 (type/attributes) Q 14 ZONE 14 (type/attributes) Q 15 ZONE 15 (type/attributes) Q 16 ZONE 16 (type/attributes) Q 17 ZONE 17 (type/attributes) Q 18 ZONE 18 (type/attributes) Q 19 ZONE 19 (type/attributes) Q 20 ZONE 20 (type/attributes) Q 21 ZONE 21 (type/attributes) Q 22 ZONE 22 (type/attributes) Q 23 ZONE 23 (type/attributes) Q 24 ZONE 24 (type/attributes) Q 25 ZONE 25 (type/attributes) Q 26 ZONE 26 (type/attributes) \ Q 27 ZONE 27 (type/attributes) Q 28 ZONE 28 (type/attributes) Q 29 ZONE 29 (type/attributes) Q 30 ZONE 30 (type/attributes) Q 31 ZONE 31 (type/attributes) Q 32 ZONE 32 (type/attributes) Q 33 ZONE 33 (type/attributes) Q 34 ZONE 34 (type/attributes) Q 35 ZONE 35 (type/attributes) Q 36 ZONE 36 (type/attributes) Q 37 ZONE 37 (type/attributes) Q 38 ZONE 38 (type/attributes) Q 39 ZONE 39 (type/attributes) Q 40 ZONE 40 (type/attributes) Q 41 ZONE 41 (type/attributes) Q 42 ZONE 42 (type/attributes) Q 43 ZONE 43 (type/attributes) Q 44 ZONE 44 (type/attributes) Q 45 ZONE 45 (type/attributes) Q 46 ZONE 46 (type/attributes) Q 47 ZONE 47 (type/attributes) Q 48 ZONE 48 (type/attributes) 10

QUESTION 49-72 CENTRAL STATION REPORT CODES Q 49 ZONE 1/2 REPORT [3132] 1 st 2 nd 1 st 2 nd zone 1 zone 2 Q 50 ZONE 3/4 REPORT [3334] 1 st 2 nd 1 st 2 nd zone 3 zone 4 Q 51 ZONE 5/6 REPORT [3536] 1 st 2 nd 1 st 2 nd zone 5 zone 6 Q 52 ZONE 7/8 REPORT [3738] 1 st 2 nd 1 st 2 nd zone 7 zone 8 Q 53 ZONE 9/10 REPORT [3940] 1 st 2 nd 1 st 2 nd zone 9 zone 10 Q 54 ZONE 11/12 REPORT [4142] 1 st 2 nd 1 st 2 nd zone 11 zone 12 Q 55 ZONE 13/14 REPORT [4344] 1 st 2 nd 1 st 2 nd zone 13 zone 14 Q 56 ZONE 15/16 REPORT [4546] 1 st 2 nd 1 st 2 nd zone 15 zone 16 Q 57 ZONE 17/18 REPORT [4748] 1 st 2 nd 1 st 2 nd zone 17 zone 18 Q 58 ZONE 19/20 REPORT [4950] 1 st 2 nd 1 st 2 nd zone 19 zone 20 Q 59 ZONE 21/22 REPORT [5152] 1 st 2 nd 1 st 2 nd zone 21 zone 22 Q 60 ZONE 23/24 REPORT [5354] 1 st 2 nd 1 st 2 nd zone 23 zone 24 Q 61 ZONE 25/26 REPORT [5556] 1 st 2 nd 1 st 2 nd zone 25 zone 26 Q 62 ZONE 27/28 REPORT [5758] 1 st 2 nd 1 st 2 nd zone 27 zone 28 Q 63 ZONE 29/30 REPORT [5960] 1 st 2 nd 1 st 2 nd zone 29 zone 30 Q 64 ZONE 31/32 REPORT [6162] 1 st 2 nd 1 st 2 nd zone 31 zone 32 Q 65 ZONE 33/34 REPORT [6364] 1 st 2 nd 1 st 2 nd zone 33 zone 34 Q 66 ZONE 35/36 REPORT [6566] 1 st 2 nd 1 st 2 n zone 35 zone 36 Q 67 ZONE 37/38 REPORT [6768] 1 st 2 nd 1 st 2 nd zone 37 zone 38 Q 68 ZONE 39/40 REPORT [6970] 1 st 2 nd 1 st 2 nd zone 39 zone 40 Q 69 ZONE 41/42 REPORT [7172] 1 st 2 nd 1 st 2 nd zone 41 zone 42 Q 70 ZONE 43/44 REPORT d [7374] 1 st 2 nd 1 st 2 nd zone 43 zone 44 Q 71 ZONE 45/46 REPORT [7778] 1 st 2 nd 1 st 2 nd zone 45 zone 46 Q 72 ZONE 47/48 REPORT [7778] 1 st 2 nd 1 st 2 nd zone 47 zone 48 QUESTION 73-85 SYSTEM REPORT CODES Q 73 DURESS/AC LOSS [AA88] 1 st 2 nd 1 st 2 nd duress AC loss Q 74 KEYPAD *&#/BAT LOSS [2299] 1 st 2 nd 1 st 2 nd & # panic low batt Q 75 OPEN/CLOSE/RF JAM [AAAA] open close 1 st 2 nd RF Jam Q 76 KEYPAD 7&9/ 1&3 [AAAA] 1 st 2 nd 1 st 2 nd 7 & 9 panic 1 & 3 panic Q 77 KEY TAMPER/CS TEST [AAAA] 1 st 2 nd 1 st 2 nd key tamper CS test Q 78 FALSE ALARM [AAAA] 1 st 2 nd 1 st 2 nd Q 79 Exit recent lockout cancel BELL SUPER/KEYPAD TAMP [AAAA] 1 st 2 nd 1 st 2 nd bell suprv kypd tamp Q 80 BYPASS/TROUBLE [AAFF] bypss rest. fire zone trbl trbl Q 81 WALK TEST [AAAA] 1 st 2 nd 1 st 2 nd download walk test Q 82 EVENT LOG [AAAA] 1 st 2 nd 1 st 2 nd 90% full 100% full Q 83 RF SUPERVISION [AAAA] RF zn low trble sprv tmp bat rst. Q 84 ARM DISABLE/CLOCK SET [AAAA] 1 st 2 nd 1 st 2 nd arm disable clock set Q 85 UP-ABOUT/CLOCK FAIL [AAAA] 1 st 2 nd 1 st 2 nd up & about clock fail Q 90 1st RF ZONE/1st DBLD ZONE [0900] First RF First Doubled Zone Zone 11

QUESTION 91-93 CROSSED ZONES L3-L4 Cross Zone Time (secs.) L3-L4 0 15 8 135 1 30 9 150 2 45 A 165 3 60 B 180 4 75 C 195 5 90 D 210 6 105 E 225 7 120 F 240 Cross Zone Time (secs.) Q 91 Q 92 CROSSED ZONES GROUP 1 [0000] First zone Second zone CROSSED ZONES GROUP 2 [0000] First zone Second zone Q 93* CROSSED ZONES TIME _x_ _x_ [0000] not used Grp 1 Grp 2 (see chart) UL: Q91-Q93 crossed zones must be disabled. 12

SUBMODE 3: WIRELESS TRANSMITTER PROGRAMMING SUBMODE 3 While in Installer Mode 1, press [ ] + [BYPASS], then select submode [3]. The display shows the following: Q#01 M3 Edit L:01 DATA: 00 ZR401 QUESTIONS 01-48 WIRELSS ZONE CONFIGURATION/SERIAL NUMBER NOTES: All zone defaults = [000 ] The [#] key must be pressed after the last digit of a serial number entry so that the serial number is correctly stored into memory. Zones Enbl RF Transmitter 7-digit serial number Zones Enbl RF Transmitter 7-digit serial number Q 01 ZONE 1 Q 25 ZONE 25 Q 02 ZONE 2 Q 26 ZONE 26 Q 03 ZONE 3 Q 27 ZONE 27 Q 04 ZONE 4 Q 28 ZONE 28 Q 05 ZONE 5 Q 29 ZONE 29 Q 06 ZONE 6 Q 30 ZONE 30 Q 07 ZONE 7 Q 31 ZONE 31 Q 08 ZONE 8 Q 32 ZONE 32 Q 09 ZONE 9 Q 33 ZONE 33 Q 10 ZONE 10 Q 34 ZONE 34 Q 11 ZONE 11 Q 35 ZONE 35 Q 12 ZONE 12 Q 36 ZONE 36 Q 13 ZONE 13 Q 37 ZONE 37 Q 14 ZONE 14 Q 38 ZONE 38 Q 15 ZONE 15 Q 39 ZONE 39 Q 16 ZONE 16 Q 40 ZONE 40 Q 17 ZONE 17 Q 41 ZONE 41 Q 18 ZONE 18 Q 42 ZONE 42 Q 19 ZONE 19 Q 43 ZONE 43 Q 20 ZONE 20 Q 44 ZONE 44 Q 21 ZONE 21 Q 45 ZONE 45 Q 22 ZONE 22 Q 46 ZONE 46 Q 23 ZONE 23 Q 47 ZONE 47 Q 24 ZONE 24 Q 48 ZONE 48 QUESTIONS 49-56 KEYFOB CONFIGURATION/SERIAL NUMBER NOTE: The [#] key must be pressed after the last digit of a serial number entry so that the serial number is correctly stored into memory. Zones Enbl RF Transmitter 7-digit serial number Q 49 KEYFOB 1 Q 50 KEYFOB 2 Q 51 KEYFOB 3 Q 52 KEYFOB 4 Q 53 KEYFOB 5 Q 54 KEYFOB 6 Q 55 KEYFOB 7 Q 56 KEYFOB 8 13

SUBMODE 4: DESCRIPTOR PROGRAMMING SUBMODE 4 While in Installer Mode 1, press [ ] + [BYPASS], then select submode [4]. The display shows the following: Q#01 DESC ZNE:01 ZONE ONE 01 QUESTION 01-48 ZONE DESCRIPTORS FOR ZONES 01-48 Q 01 ZN 1 Q 25 ZN 25 Q 02 ZN 2 Q 26 ZN 26 Q 03 ZN 3 Q 27 ZN 27 Q 04 ZN 4 Q 28 ZN 28 Q 05 ZN 5 Q 29 ZN 29 Q 06 ZN 6 Q 30 ZN 30 Q 07 ZN 7 Q 31 ZN 31 Q 08 ZN 8 Q 32 ZN 32 Q 09 ZN 9 Q 33 ZN 33 Q 10 ZN 10 Q 34 ZN 34 Q 11 ZN 11 Q 35 ZN 35 Q 12 ZN 12 Q 36 ZN 36 Q 13 ZN 13 Q 37 ZN 37 Q 14 ZN 14 Q 38 ZN 38 Q 15 ZN 15 Q 39 ZN 39 Q 16 ZN 16 Q 40 ZN 40 Q 17 ZN 17 Q 41 ZN 41 Q 18 ZN 18 Q 42 ZN 42 Q 19 ZN 19 Q 43 ZN 43 Q 20 ZN 20 Q 44 ZN 44 Q 21 ZN 21 Q 45 ZN 45 Q 22 ZN 22 Q 46 ZN 46 Q 23 ZN 23 Q 47 ZN 47 Q 24 ZN 24 Q 48 ZN 48 QUESTIONS 49-51 PARTITION DESCRIPTORS Q 49 PART. 1 Q 50 PART. 2 Q 51 PART. 3 14

15

ÊN9938PRV3Š N9938PRV3 4/04 Rev. A 165 Eileen Way, Syosset, New York 11791 Copyright 2004 Honeywell International Inc. www.honeywell.com/security