FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

Similar documents
FBII Security System. Programming Guide. Version 2.X. N9938PRV3 4/04 Rev. A

First Alert 1200C Installer Notes M. Leuck

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

VISTA-100 Commercial Fire & Burglary Partitioned System

Property of Monitronics Inc

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

CC488. Quick Reference Guide Solution Ultima 880

VISTA-20PMT. Programming Guide. This control is a certified SIA-compliant control that meets SIA specifications for False Alarm Reduction.

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

GEM-P800 Programming Instructions

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CC408. Quick Reference Guide Solution 880

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Property of Monitronics Inc

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

2000 Series. Program Entry Guide. Control Panels

Control/Communicator Installation Manual

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

Installation Instructions

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

FBII Security System. Installation and Setup Guide. Version 2.0. N9938V4 8/06 Rev. A

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

NetworX Series NX-4V2 Control Panel Installation and Startup

Radionics D4112 Program Sheet

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Series. NX-4-EUR Control Panel. Installation manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

ADEMCO CONTACT ID REPORTING (revised )

VISTA-128FB. Quick Start Guide. Commercial Fire & Burglary Partitioned Security System. with Scheduling.

USER GUIDE HARDWIRED CONTROL PANELS

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN

INSTALLATION MANUAL & PROGRAM RECORD SHEET

System Programming Guide

PROGRAMMING INSTRUCTIONS

RE6100 Series Helix Security and Automation Platform

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Installation Instructions

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Programming Worksheets

Control/Communicator

4-PGM Expansion Module

/10 Rev A

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

PROGRAMMING INSTRUCTIONS

8-zone Expansion Module

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

Quick Programmer s Manual

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

Contact ID as of 2/2/2015

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

Contact ID as of 11/28/2018

USER GUIDE HARDWIRED CONTROL PANELS

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

NX-4V2 Control Panel Installation Instructions

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Summit 3208GLD USER MANUAL. Electronics Line

USER GUIDE HARDWIRED CONTROL PANELS

LYNX Touch Security System

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

CHEAT SHEET: SPECTRA V2.1

SENTROL ZX400/ZX410. Security System Control. Programming

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

Solution 862 Installation Manual ISSUE 1.30

Training Manual Multi-Language with Wireless

ADEMCO VISTA-12A ADEMCO VISTA-12E

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

/<1; 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH N8889V1 10/98 OFF AWAY STAY AUX

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems

ADEMCO VISTA-48 SERIES

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

GEM-P800. Control Panel/Communicator. Installation Instructions

AXI LED USER MANUAL (REV. 1.0)

Type Report Report Date: 1/21/2015

VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

LYNXR-2 Series Security System

LYNX ,QVWDOODWLRQ,QVWUXFWLRQV. ALPHA DRAFT. June 5, 1998 N8889 5/98 OFF AWAY STAY AUX

ADEMCO LYNX XL SERIES Security System

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

Transcription:

FBII Security System OMNI -624 Version 2.X Programming Guide N9967PRV3 4/04 Rev. A

CONTENTS INSTALLER MODE 1 COMMANDS... 3 INSTALLER MODE 1 (PROGRAMMING MODE)... 4 SUBMODE 1: SYSTEM OPTIONS... 4 Telephone and Pager Numbers... 4 Account Numbers... 4 Reporting and System Options... 4 CS Format/Rcvr Type... 4 Reporting Options... 5 System Options... 5 Other System Options... 5 Arming Options... 5 Sound Options... 5 Display Options... 5 Log Options... 5 Bells/AC Delay/Ring Cnt... 5 Exit Delay/Dialer Delay... 5 Delay 1... 5 Delay 2... 5 C/S Test Time... 5 Pager Options... 5 Keypad Tamper... 5 RF Jam... 5 Soft Keys for 1 & 3/7 & 9... 5 Soft Keys for & #... 5 Auto Arm Enables... 5 Auto Arm Time P1 (User)... 5 Auto Arm Time P2 (User)... 5 Trigger/Relay Types... 7 Keypad Mapping... 7 Keyfob Button Functions... 8 Relay/Trigger Time for Momentary Outputs... 8 Open/Close CS Report Disables... 8 SUBMODE 2: ZONE PROGRAMMING AND REPORT CODES... 9 Zone Report Codes... 10 System Report Codes... 10 Duress/AC Loss... 10 Bypass/Trouble... 10 Keypad & #/Bat Loss... 10 Walk Test... 10 Open/Close & RF Jam... 10 Event Log... 10 Keypad 7 & 9/1 & 3... 10 RF Supervision... 10 Keypad Tamper/CS Test... 10 Arm Disable/Clock Set... 10 False Alarm... 10 Up-About/Clock Fail... 10 Bell Supervision... 10 Keypad Tamper... 10 1st RF Zone/1st Dbld Zone... 10 Crossed Zones... 10 SUBMODE 3: WIRELESS TRANSMITTER PROGRAMMING... 11 Wireless Zone Configuration/Serial Number... 11 Keyfob Configuration/Serial Number... 11 SUBMODE 4: DESCRIPTOR PROGRAMMING... 12 Zone Descriptors for Zones 01 24... 12 Partition Descriptors... 12 2

To INSTALLER MODE 1 COMMANDS Press Enter Installer Mode 1 [CODE] [ ] (installer s code) [1] (select submode number 1 4) Sub Modes: System Options Zone Prog./Report Codes Wireless Programming Descriptor Programming Enter data Go to next location in question [#] Go to next question (enter installer mode 1) [1] (enter installer mode 1) [2] (enter installer mode 1) [3] (enter installer mode 1) [4] appropriate key then [#] to accept entry [INSTANT] or [ ] (2-digit question no.) Go to another submode [ ] [BYPASS] (select desired submode number 1 4) Exit Program Mode [STAY] N9967PRV3 4/04 Rev. A

INSTALLER MODE 1 (Programming Mode) SUBMODE 1: SYSTEM OPTIONS Enter installer mode 1, then select submode 1. The display shows the following: Q#01 M1 Edit L:01 DATA: 234A System Default values are shown inside brackets. NOTE: When you enter Submode 1, question 01 is automatically displayed. To change or review the Installer Code (question 00), enter [ ] + [0] + [0]. The Installer Code will be displayed. Q 00 Installer Code N/U N/U [246800AA] QUESTIONS 01 05: TELEPHONE and PAGER NUMBERS Enter the appropriate telephone numbers in Questions 1 5. Questions 1 3 support up to 20-digit numbers. Questions 4 and 5 supports up to 16-digit numbers. Q 01 PRIMARY CS NUMBER [234A ] Q 02 SECONDARY CS No. [AAA ] Q 03 CALLBACK NUMBER [AAA ] Q 04 PARTITION 1 PAGER NUMBER [AAA ] Q 05 PARTITION 2 PAGER NUMBER [AAA ] QUESTIONS 06 09: ACCOUNT NUMBERS Enter the appropriate account numbers in questions 06 through 09. 3-digit formats will ignore last digit. Q 06 PART. 1 PRIMARY [1234] Q 08 PART. 2 PRIMARY [1222] Q 07 PART. 1 SECONDARY [2234] Q 09 PART. 2 SECONDARY [2222] QUESTIONS 10 31: REPORTING and SYSTEM OPTIONS For detailed explanations, refer to the programming tables in the Installation Instructions when making the following entries. You can also calculate the value of an entry by adding the binary values of the desired options in each location. The values are, from top to bottom, 1, 2, 4, 8. Enter 0 if none of the options are desired. Enter A F for values of 10 15 respectively. For Questions with locations containing more than 4 options, charts listing them are provided (these options are indicated with an asterisk). Q 10 CS FORMAT/RCVR TYPE [E0E0] L1 L2 L3 L4 CS1 CS2 Format Rcvr Format Rcvr (see chart below for values to enter) L1/L3 CS REPORTING TRANS L2/L4 FORMAT PULSE SPEED HANDSHAKE FORMAT TYPE 10 PPS 20 PPS 40 PPS 1400 HZ 2300 HZ Parity TYPICAL CS RECEIVER 0 3x1 Standard PULSE 0 FBII, ADEMCO, SILENT KNIGHT 1 4x1 Standard PULSE 1 FBII, ADEMCO, RADIONICS 2 3x1 Extended PULSE 2 FBII 3 4x1 Extended PULSE 4 FBII, SILENT KNIGHT 4 3x1 Partial Extended PULSE 5 FBII, RADIONICS 5 4x1 Partial Extended PULSE 6 FBII, RADIONICS 6 3x2 PULSE 8 FBII 7 4x2 PULSE 9 FBII, ADEMCO 8 FBII Superfast DTMF A FBII, ADEMCO 9 ADEMCO 4x1 Express * DTMF C FBII, ADEMCO A ADEMCO 4x2 Express * DTMF D FBII, ADEMCO E ADEMCO Contact ID * DTMF E FBII, ADEMCO N9967PRV3 4/04 Rev. A

Q 11 REPORTING OPTIONS L1* L2 L3 L4 [07FF] Dial Type Restore Dial attmpts Restores report option supervsn (1-15) AC sends rstr report option tamper Low Bat sends rstr rpt stay byp RF low bat zone sends rstr FTO/LTC rstr follows loop Dial type report option 00=backup, 01=dual, 10=split, 11=disabled Q 12 SYSTEM OPTIONS UL: L4 must be 3. [0020] L1 L2 L3 L4* no bell/dial n/a euro pulse test time interval fast zone 5/6 Relay enbl. tone/pulse dbl bal n/a user 6/4 digit RF enable bell sprvs. Q 13 OTHER SYSTEM OPTIONS UL: L1 door strike option not evaluated by UL. [48C2] L1 L2 L3* L4 user online key tamp. pager attmpt swinger count duress (31, 32) tamp reset pager attmpt (0-3) no code dr strike crystal RTC sprv time bat test 4/1s door (20-30) tone burst on sprv time delay if stay Q 14 ARMING OPTIONS UL: Do not use L2 bypass error, [818F] L3 exit extends, L4 quick exit L1 L2 L3 L4 stay=stay arm w/fault disbl arm P1 quick arm fob autostay byp/exit err disbl arm P2 force arm inst=away arm no dwnld n/a quick exit inst enbl no arm lo bat exit ext. quick bypass Q 15 SOUND OPTIONS UL: L4 must be F. L1 L2 L3 L4 fob ding only thresh sndr phone fail en. RF sprv bell ding enbl thresh bell phn fail sndr RF lo bat disarm ding enbl CS test ring phn fail bell sys lo bat fast ding invert bell bell on cancel AC loss Q 16 DISPLAY OPTIONS [000F] UL: Do not enable L1 no AC loss (must display AC loss) [1130] L1 L2 L3 L4 armed byp time w/o code clock 24hr Language fault on entry daylight save day/mo (0=Eng, 1=Ital,) AC loss LED extinguish show time 2=Span, 3= French Byp limit 3 FOB LB clock fail 4=Dutch, 5= Port) Q 17 LOG OPTIONS _ x _ L1 L2 L3 [EFF0] By Part/all open RF bat En #53 log close RF sprv log zone alarm sys events tamper log zone trbl key events bypass Q 18 BELLS/AC DELAY/RING CNT UL: L1 and L2 must be 2. L3 must be F. [5F18] L1* L2* L3* L4 Burg bell Fire bell AC dial ring timeout timeout delay count (times 3min) (times 3 min) (times 15 min) (0-15, 0=disable) (0=random) Q 19 EXIT DELAY/DIALER DELAY L1 L2 L3 L4 [CC00] Exit Exit n/a abort dial time P1 time P2 delay time* (Exit time = value times 10 for number of seconds; for dial delay, see dialer delay chart on next page for Question 19) UL: L1, L2 must be 5. L4 dial delay must be 0. Q 20 ENTRY DELAY 1 _x_ _x_ L1 L2 [5500] time 1 P1 time 1 P2 (For values, see entry delay charts on next page for Questions 20 and 21) UL: Q20/Q21 entry delay must be 6 (45 seconds) Q 21 ENTRY DELAY 2 _x_ _x_ L1 L2 [3300] time 2 P1 time 2 P2 (For values, see entry delay charts on next page for Questions 20 and 21) Q 22 C/S TEST TIME (0300) Hours Minutes (00-23) (00-59) Q 23 PAGER OPTIONS _x_ L1 (part. 1) L2 (part. 2) L3 L4 zone alarm zone alarm n/a enbl users page P1 zone trbl zone trbl enbl users page P2 open open n/a close close #58 follow-me Q 24 KEYPAD TAMP, ARM & RF JAM _x_ L1 L2 L3 L4 n/a keypad tamp no arm if jam jam detect enable tamp sound no arm super jam Euro/US tamp bell no AC 2X jam sounder jam bell Q 25 NOT USED Q 26 SOFT KEYS FOR 1 & 3/7 & 9 1 & 3 Keys 7 & 9 Keys L1* L2 L3* L4 sound opt arm away sound opt arm away (chart below) arm stay (chart below) arm stay relay opt page trbl relay opt page trbl (chart below) (chart below) Q 27 SOFT KEYS FOR & # _x_ _x_ L1* L2 & # Keys not used sound opt arm away [2000] (chart below) arm stay relay opt page trbl (chart below) Q 28 AUTO ARM ENABLES _x_ UL: L1, L2 must be 0. L1 L2 L3 L4 auto arm P1 auto arm P2 n/a up/about P1 arm warn P1 arm warn P2 up/about P2 instant arm P1 instant arm P2 stay arm P1 stay arm P2 Q 29 AUTO ARM TIME P1 (0000) Hours Minutes UL: Must be disabled. (00-23) (00-59) Q 30 AUTO ARM TIME P2 (0000) Hours Minutes UL: Must be disabled. (00-23) (00-59) Q 31 NOT USED For Q 26 & Q 27, L1/L3: Sounder Options Relay Options L1/L3 Burg. No Mom. Mom. Silent Keypad Bell Temporal Relay Seconds Minutes Toggle 0 1 2 3 4 5 6 7 8 9 A B C D E F * Refer to the charts on the next page (except Questions 26 & 27; see chart above, right). 5

Use the following charts when making entries for Questions 11, 12, 13, 19, 20, 21. Q 11, L1: Enter the L1 digit for the desired reporting options from the table below. L1 Report Type Report First to open Backup Dual Split Disabled Stay Bypass Last to close 0 1 2 3 4 5 6 8 9 A C D E Q 12, L4: Enter the L4 digit for the desired options from the table below. L4 Test Interval by Time Disable Every Hour 1 Day 7 Days 27 Days 60 Days 90 Days 180 Days 0 1 2 3 4 5 6 7 Test Interval Reset by Event 9 A B C D E Q 13, L3: Enter the L3 digit from the table below. L3 Pager Attempts 0 1 2 3 Supervision Time (Hrs) 20/1* 6 18 24 0 Disabled 1 2 3 4 Disabled 5 6 7 8 Disabled 9 A B C Disabled D E F *20 Minutes when disarmed 1 Hour when armed Q19, L4: Enter the L4 digit for the desired dialer delay from the following table. L4 Dialer Delay Seconds 0 15 1 20 2 25 3 30 4 40 5 50 6 60 7 75 8 90 9 105 A 120 B 150 C 180 D 210 E 240 F 255 Q 20 and 21, L1 L2: These questions define entry delays 1 and 2. L1-L2 Delay (Seconds) L1-L2 Delay (Seconds) 0 1 8 75 1 5 9 90 2 10 A 105 3 15 B 120 4 20 C 150 5 30 D 180 6 45 E 210 7 60 F 240 6

QUESTIONS 32 43: TRIGGER/RELAY TYPES For Questions 32 43, make entries from the table in the right column. Note: Triggers 3 and 4 are used for the XL4705 relay module if selected in Question 12, L2 Q 32 RELAY 1 and 2 TYPES Relay 1 Relay 2 Q 33 RELAY 3 and 4 TYPES Relay 3 Relay 4 Q 34 RELAY 5 and 6 TYPES Relay 5 Relay 6 Q 35 RELAY 7 and 8 TYPES Relay 7 Relay 8 Q 36 RELAY 9 and 10 TYPES Relay 9 Relay 10 Q 37 RELAY 11 and 12 TYPES Relay 11 Relay 12 Q 38 RELAY 13 and 14 TYPES Relay 13 Relay 14 Q 39 RELAY 15 and 16 TYPES Relay 15 Relay 16 Q 40 RELAY 17 and 18 TYPES Relay 17 Relay 18 Q 41 RELAY 19 and 20 TYPES Relay 19 Relay 20 Q 42 TRIGGER 1 and 2 TYPES Trigger 1 Trigger 2 Q 43 TRIGGER 3 and 4 TYPES Trigger 3 Trigger 4 P1 P2 Relay Type 00 00 Disabled 01 41 Burg Bell no Bell Test 02 42 Fire Bell no Bell Test 03 43 Partition Armed 04 44 Partition Ready 05 45 In Delay 06 46 In Exit Delay 07 47 Armed Instant 08 48 Armed Stay 09 49 Sounder on/pulsing 0A 4A Chime 0B n/a Line Seize (System) 0C n/a Phone Fail (System) 0D n/a AC Loss (System) 0E n/a Low Battery (System) 0F 4F 24 Hr Zone in Trouble 10 50 24 Hr Zone Alarmed 11 51 Instant Zone Faulted 12 52 Delay Zone Faulted 13 53 Interior Zone Faulted 14 54 Zone Tamper 15 55 RF Low Battery 16 56 RF Supervision 17 n/a Comm. Fail (System) 18 58 Key Tamper, mom. Sec 19 59 Duress Code, mom. Sec 1A 5A Bell Strobe - Internal, No dings 1B 5B Bell Strobe - External, with dings 1C 5C Trigger Zone, mom Minutes 1D 5D Trigger Zone, mom. Seconds 1E 5E Door Strike, mom. Seconds 1F 5F Shock Reset (*) Seconds 20 60 CS Test Momentary Secs. 21 61 Alarm/Restore by partition 22 n/a 2-way voice, on after seize rel. 23 63 Momentary by Seconds (fob,soft) 24 64 Momentary by Minutes (fob,soft) 25 65 Toggle (Keyfob, softkeys) 26 n/a Follows Zn Loop, Trig=Zn 1 20 27 n/a Follows Zn Loop, Trig=Zn 21 24 28 n/a Zone alarm - zones zones 1 20 29 n/a Zone alarm - zones zones 21 24 2A n/a Zone alarm restore - zones 1 20 2B n/a Zone alarm restore - zones 21 24 2C n/a Sys Bell, Internal (no Dings) 2D n/a Sys Bell, External (with Dings) 2E 6E RF Jam 2F n/a Keypad Tamper 30 70 24 Hour Silent Zone QUESTIONS 44-45 KEYPAD MAPPING The system automatically reads keypad addresses during initial installation. Questions 44-45 are shown for reference and/or programming after initial installation. NOTE: LCD = OMNI-LCD, OMNI-LCD-US, or XK7LC; Non-LCD = OMNI-KP or OMNI-KP-US Q 44 KEYPAD MAP for PART. 1 L1 L2 L3 L4 [8000] LCD 5 LCD 1 non-lcd 5 non-lcd 1 LCD 6 LCD 2 non-lcd 6 non-lcd 2 LCD 7 LCD 3 non-lcd 7 non-lcd 3 LCD 8 LCD 4 non-lcd 8 non-lcd 4 Q 46-48 NOT USED Q 45 KEYPAD MAP for PART. 2 L1 L2 L3 L4 LCD 5 LCD 1 non-lcd 5 non-lcd 1 LCD 6 LCD 2 non-lcd 6 non-lcd 2 LCD 7 LCD 3 non-lcd 7 non-lcd 3 LCD 8 LCD 4 non-lcd 8 non-lcd 4 N9967PRV3 4/04 Rev. A

QUESTIONS 49-64 KEYFOB BUTTON FUNCTIONS and USERS For Odd Numbered Questions 49-63, make entries from the following table: L1-L4 Keyfob Function L1-L4 Keyfob Function 0 Disabled 6 Keypad fire 1 Disarm 7 keypad panic 2 Arm away 8 keypad aux. 3 Arm stay 9 relay type 23 (mom. seconds) 4 Arm instant A relay type 24 (mom. minutes) 5 Arm stay/instant B relay type 25 (toggle) For Even numbered Questions 50-64, enter primary arming partition 1or 2 and 2-digit user no.. Make L2 entry from the following table: L2 Arming Partition 1 1 2 2 UL: Keyfobs not evaluated for UL installations. Q 49 KEYFOB 1 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 50 KEYFOB 1 USER _x_ [0001] arm User no. part Q 51 KEYFOB 2 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 52 KEYFOB 2 USER _x_ [0001] arm User no. part Q 53 KEYFOB 3 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 54 KEYFOB 3 USER _x_ [0001] arm User no. part Q 55 KEYFOB 4 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 56 KEYFOB 4 USER _x_ [0001] arm User no. part Q 57 KEYFOB 5 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 58 KEYFOB 5 USER _x_ [0001] arm User no. part Q 59 KEYFOB 6 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 60 KEYFOB 6 USER _x_ [0001] arm User no. part Q 61 KEYFOB 7 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 62 KEYFOB 7 USER _x_ [0001] arm User no. part Q 63 KEYFOB 8 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 64 KEYFOB 8 USER _x_ [0001] arm User no. part QUESTIONS 65/66 RELAY/TRIGGER TIME for MOMENTARY OUTPUTS Enter 0-F (0-15) for each location in questions 65 and 66 (P1-P2 = partition 1 to partition 2 respectively). Q 65 RELAY/TRIG TIME MIN. _x_ _x_ Q 66 RELAY/TRIG TIME SECS. P1 P2 P1 P2 _x_ _x_ QUESTIONS 67-68 OPEN/CLOSE CENTRAL STATION REPORT DISABLES Enter 0-F (0-15) for each location in questions 67-68. Q 67 OP/CL DISABLE Users 1-16 Q 68 OP/CL DISABLE Users 17-32 1 5 9 13 2 6 10 14 3 7 11 15 4 8 12 16 17 21 25 29 18 22 26 30 19 23 27 31 20 24 28 32 8

SUBMODE 2: ZONE PROGRAMMING AND REPORT CODES While in Installer Mode 1, press [ ] + [BYPASS], then select submode [2]. The display shows the following: Q#01 M2 Edit L:01 DATA: 2000 Zn/Cde Use the following tables when programming zones. L1: Select entry from the following table: L1 Zone Type Controlled Types L1 Zone Type 24 Hour Types 0 Disabled 8 Keyswitch 1 Instant 9 Trigger Zone 2 Delay A Trouble Zone 3 Delay 2 B Alarm Zone 4 Interior C Alarm/Trouble 5 Day Zone E Fire No Verification L2: Select entry from the following table: F Fire With Verification L2 Partition Hardwire Loop Type Wireless Supervision 1 2 EOL N/C N/O Supervise Tamper 0 1 4 5 8 9 L3: 0 = none; 1 = silent zone; 2 = swinger suppression zone; 3 = both silent zone and swinger suppression zone. UL: L3 swinger suppression must be disabled. L4: Select entry from the following table: L4 Stay Auto-Stay Chime Dial Delay 0 1 2 3 4 5 6 7 8 9 A B C D E F Q 01 ZONE 1 (type/attributes) [2000] Q 02 ZONE 2 (type/attributes) [4000] Q 03 ZONE 3 (type/attributes) [1000] Q 04 ZONE 4 (type/attributes) [1000] Q 05 ZONE 5 (type/attributes) [1000] Q 06 ZONE 6 (type/attributes) [1000] Q 07 ZONE 7 (type/attributes) Q 08 ZONE 8 (type/attributes) Q 09 ZONE 9 (type/attributes) Q 10 ZONE 10 (type/attributes) Q 11 ZONE 11 (type/attributes) Q 12 ZONE 12 (type/attributes) Q 13 ZONE 13 (type/attributes) Q 14 ZONE 14 (type/attributes) Q 15 ZONE 15 (type/attributes) Q 16 ZONE 16 (type/attributes) Q 17 ZONE 17 (type/attributes) Q 18 ZONE 18 (type/attributes) Q 19 ZONE 18 (type/attributes) Q 20 ZONE 18 (type/attributes) Q 21 ZONE 21 (type/attributes) Q 22 ZONE 22 (type/attributes) Q 23 ZONE 23 (type/attributes) Q 24 ZONE 24 (type/attributes) 9

QUESTIONS 25 36: ZONE REPORT CODES Q 25 ZONE 1/2 REPORT Q 31 ZONE 13/14 REPORT [6142] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 1 zone 2 zone 13 zone 14 Q 26 ZONE 3/4 REPORT Q 32 ZONE 15/16 REPORT [3334] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 3 zone 4 zone 15 zone 16 Q 27 ZONE 5/6 REPORT Q 33 ZONE 17/18 REPORT [3536] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 5 zone 6 zone 17 zone 18 Q 28 ZONE 7/8 REPORT Q 34 ZONE 19/20 REPORT [3030] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 7 zone 8 zone 19 zone 20 Q 29 ZONE 9/10 REPORT Q 35 ZONE 21/22 REPORT [3030] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 9 zone 10 zone 21 zone 22 Q 30 ZONE 11/12 REPORT Q 36 ZONE 23/24 REPORT [3030] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 n zone 11 zone 12 zone 23 zone 24 QUESTIONS 37 49: SYSTEM REPORT CODES Q 37 DURESS/AC LOSS Q 44 BYPASS/TROUBLE [AA88] 1 st 2 nd 1 st 2 nd [AAFF] bypss rest. fire trbl zone trbl duress AC loss Q 38 KEYPAD & #/BAT LOSS Q 45 WALK TEST [2299] 1 st 2 nd 1 st 2 nd [AAAA] 1 st 2 nd 1 st 2 nd & # panic low batt download walk test Q 39 OPEN/CLOSE & RF JAM Q 46 EVENT LOG [AAAA] open close RF jam [AAAA] 1 st 2 nd 1 st 2 nd 90% full 100% full Q 40 KEYPAD 7 & 9/1 & 3 Q 47 RF SUPERVISION [AAAA] 1 st 2 nd 1 st 2 nd [AAAA] RF sprv zn tmp low bat trble rst. 7 & 9 panic 1 & 3 panic Q 41 KEY TAMPER/CS TEST Q 48 ARM DISABLE/CLOCK SET [AAAA] 1 st 2 nd 1 st 2 nd [AAAA] 1 st 2 nd 1 st 2 nd key tamper CS test arm disable Q 42 FALSE ALARM Q 49 UP-ABOUT/CLOCK FAIL [AAAA] 1 st 2 nd 1 st 2 nd [AAAA] 1 st 2 nd 1 st 2 nd Q 43 Exit recent lockout cancel BELL SUPER/KEYPAD TAMP [AAAA] 1 st 2 nd 1 st 2 nd bell suprv kypd tmpr up & about clock set clock fail Q 50 1st RF ZONE/1st DBLD ZONE [0700] First RF Zone First Doubled Zone QUESTIONS 51 53: CROSSED ZONES L3-L4 Cross Zone Time (secs.) L3-L4 Cross Zone Time (secs.) 0 15 8 135 1 30 9 150 2 45 A 165 3 60 B 180 4 75 C 195 5 90 D 210 6 105 E 225 7 120 F 240 Q 51 Q 52 CROSSED ZONES GROUP 1 First zone Second zone CROSSED ZONES GROUP 2 First zone Second zone Q 53 CROSSED ZONES TIME _X _ _ X_ Grp 1 Grp 2 (see chart) UL: Q51-Q53 crossed zones must be disabled. N9967PRV3 4/04 Rev. A

SUBMODE 3: WIRELESS TRANSMITTER PROGRAMMING While in Installer Mode 1, press [ ] + [BYPASS], then select submode [3]. The display shows the following: Q#01 M3 Edit L:01 DATA: 00 ZR401 QUESTIONS 01-24: WIRELESS ZONE CONFIGURATION/SERIAL NUMBER All zone defaults = [000 ] Zones Enbl RF Transmitter 7-digit serial number Q 01 ZONE 1 Q 13 Zones Enbl RF Transmitter 7-digit serial number ZONE 13 Q 02 ZONE 2 Q 14 ZONE 14 Q 03 ZONE 3 Q 15 ZONE 15 Q 04 ZONE 4 Q 16 ZONE 16 Q 05 ZONE 5 Q 17 ZONE 17 Q 06 ZONE 6 Q 18 ZONE 18 Q 07 ZONE 7 Q 19 ZONE 19 Q 08 ZONE 8 Q 20 ZONE 20 Q 09 ZONE 9 Q 21 ZONE 21 Q 10 ZONE 10 Q 22 ZONE 22 Q 11 ZONE 11 Q 23 ZONE 23 Q 12 ZONE 12 Q 24 ZONE 24 QUESTIONS 25 32: KEYFOB CONFIGURATION/SERIAL NUMBER Zones Enbl RF Transmitter 7-digit serial number Q 25 KEYFOB 1 Q 26 KEYFOB 2 Q 27 KEYFOB 3 Q 28 KEYFOB 4 Zones Enbl RF Transmitter 7-digit serial number Q 29 KEYFOB 5 Q 30 KEYFOB 6 Q 31 KEYFOB 7 Q 32 KEYFOB 8 N9967PRV3 4/04 Rev. A

SUBMODE 4: DESCRIPTOR PROGRAMMING While in Installer Mode 1, press [ ] + [BYPASS], then select submode [4]. The display shows the following: Q#01 DESC ZNE:01 ZONE ONE 01 QUESTIONS 01 24: ZONE DESCRIPTORS FOR ZONES 01 24 Enter up to 16 characters Q 01 ZN 1 Q 02 ZN 2 Q 03 ZN 3 Q 04 ZN 4 Q 05 ZN 5 Q 06 ZN 6 Q 07 ZN 7 Q 08 ZN 8 Q 09 ZN 9 Q 10 ZN 10 Q 11 ZN 11 Q 12 ZN 12 Q 13 ZN 13 Q 14 ZN 14 Q 15 ZN 15 Q 16 ZN 16 Q 17 ZN 17 Q 18 ZN 18 Q 19 ZN 19 Q 20 ZN 20 Q 21 ZN 21 Q 22 ZN 22 Q 23 ZN 23 Q 24 ZN 24 QUESTIONS 25 26: PARTITION DESCRIPTORS Enter up to 16 characters for each partition Q 25 PART. 1 Q 26 PART. 2 N9967PRV3 4/04 Rev. A

NOTES 13

NOTES 14

NOTES 15

165 Eileen Way, Syosset, New York 11791 Copyright 2004 Honeywell International Inc. ÊN9967PRV3gŠ N9967PRV3 4/04 Rev. A www.honeywell.com/security