Instruction Manual Captive Air Level Control. Model NLP

Similar documents
Operating instructions For Vibration level switch. Model NSV

Operating Instructions for Liquid Level Transducer Model : MM Series

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent

The CE Marking Access to the European Market

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

Operating Instructions

BCF1080 FORWARD PLATE COMPACTORS PARTS BOOK

EG KONFORMITÄTSERKLÄRUNG EC DECLARATION AND MANUFACTURER S DECLARATION OF CONFORMITY CE DÉCLARATION DE CONFORMITÉ CE DICHIARAZIONE DI CONFORMITÀ

Manual Isolating Barrier D461R1 (Revision 01)

VACOOK. Thermocirculator for Sous Vide cooking USE AND MAINTENANCE MANUAL

CTC EcoMiniEl. Installation- and Maintenance Manual. External electric boiler. Providing sustainable energy solutions worldwide

DL/DLM. Operating instructions Manuel d instructions Instrucciones de uso

Mounting and Operating Instructions EB 5206 EN. Thermostats. Type 5343 Safety Temperature Monitor (STM) Type 5344 Temperature Regulator (TR)

Manual Isolating Barrier D461 (Revision 05)

IDEAL IDEAL Modular conveyor belt system. Operating Instructions

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Constant Temperature Waterbaths

Operating Instructions for Air-Flow Monitor. Model: LPS-P

Instructions: Erkopress _motion. Erkopress ci motion

CTC EcoZenith C 530 l 510

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Fire-fighting. TRITON Range USER MANUAL TRITON HF 12L - 24V. Version 1 07/11/17

Operating Instructions for Rotor flow Indicator. Model: DKF

Manual. Monitoring Device BS

INSTRUCTION MANUAL. PLASTIC MENDER mod. ITA

ESG Plus ESG Plus 2. Operating instructions with spare parts list. Tungsten Grinder. Machine-no.:

Manual OW Caution:

GLASS WASHING MACHINE INSTRUCTION MANUAL

Hardware User s Manual

Operating Manual Ionizer

Hardware User s Manual


Hardware User s Manual


Operating Instructions

OPERATING INSTRUCTIONS

Use and maintenance manual

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

MANUAL. for heat press. Secabo TC2

CESI EXTENSION D. 02/12 ~ FGH ~ to EC-Type Examination Certificate CESI 03A TEX057X Equipment: Explosion proofsolenoid series OA-; OZA; MZA-A- Manufac

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction BENTOFLEX ST120KA

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

OPERATING INSTRUCTIONS. for the heat press. Secabo TCC

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

QBx Sub. Powered Subwoofer Owner s Manual

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

02PN8 HI-PE/CF --- Rev. F044GB60K10 1

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

OPERATING INSTRUCTIONS

REC LRD0 / LGD0 DE EN FR IT ES NL RU PL LT LV SR CZ RO BG HU

Waste heat exchanger - CHRP-S

Wilo-Yonos PARA. Installation & Operating Instructions. de en. Einbau- und Betriebsanleitung

User Manual. WR10-CP-LED 10 W Art.-No.: WR20-CP-LED 20 W Art.-No.: WR30-CP-LED 30 W Art.-No.

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art

DECLARATION OF CONFORMITY

MULTI-MAX. A) Application - Operating with wheels Do not work without protection cover

EG-Konformitätserklärung / EC deciaration of conformity / d6claration «CE» de conformite

MANUAL. for heat presses. Secabo TC5 and TC7

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

1592P01. for liquids in piping DN

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD12

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Service & Operating Manual

USER MANUAL ELETTROFOG EWB7500 FRANCE

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 70-2/3

DECLARATION OF CONFORMITY KONFORMITÄTSERKLÄRUNG

CHATTANOOGA JUNIOR STAR

Temperature Sensor TRG Original Installation Instructions English

Fire classification of construction products and building elements

KREBS DUO. - Assembly instructions. - Safety indications. - How to start and handle the machine. - Inspection and maintenance

Operating Manual MS220Vi and MSR220Vi

REFLOW OVEN FT01 Version REFLOW OVEN FT01. (Article number F31105) User s Manual

WIO200 Water In Oil measuring instrument

Hazardous Location Heaters. 50W and 80W Models INSTRUCTION MANUAL. Rev. I 2018 nvent P/N

DAMPF-TAPETENABLÖSER STEAM WALLPAPER STRIPPER DECOLLEUSE À PAPIERS PEINTS BEHANGSTOMER VAPORELLA STACCAPARATI W14 / W15 / W16 OWNER S MANUAL

PIT UMF2 (B) Magnetic-Inductive Flow Velocity Sensor. Operating Manual. Page 1 of 14

EN ISO/IEC :2016/AC

INSTRUCTION BOOKLET MAINTENANCE INSTRUCTIONS INSIDE THE WASHING MACHINE

Conductivity Electrode LRG Original Installation Instructions English

Translation of the original document.

Advance Plus User Manual

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

DECLARATION OF CONFORMITY

LOMOND - Fluorescent Luminaires ATEX

Installation instructions for washers HS-6008 / EH020

Installation and Maintenance Manual CTC EcoPart i425-i435 Pro CTC EcoPart

ESG Plus ESG Plus 2. Operating instructions with spare parts list. Tungsten Grinder

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Hardware User s Manual

IsOver SAINT-GOBAIN. EG-Konformitätserklärung / EC deciaration of conformity / sziclaration «CE» de conformitä

Centrifugal pump type WK

Installation- and Maintenance Manual CTC EcoAir 510M. Modulating air/water heat pump 400V 3N~ Providing sustainable energy solutions worldwide

Isover SAINT-GOBAIN. EG-Konformitätserklärung / EC declaration of conformity / declaration «CE» de conformitä

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Physikalisch-Technische Bundesanstalt

Operating Instructions TSF 010. Power Failure Venting Unit PM BNE/L (0007)

OPERATING MANUAL RAY-NC 1000 SERIES

FLIR A310 ex 45. Protection class

Transcription:

Instruction Manual Captive Air Level Control Model NLP

1. Contents Page 1. Contents...2 2. Note...3 3. Inspection of the instrument...3 4. Description...3 5. Operation...3 6. Mechanical Assembly...4 7. Electrical Connection...4 8. Sensitivity Setting...4 9. Technical Information...5 10. Dimensions...6 11. Part Number Selection...6 12. Declaration of Conformity...7 Manufactured and distributed by: Kobold Mesura S.L.U. Avda. Conflent, 68 Nave 15 08915 Badalona Tel.: +34 93 460 38 83 Fax: +34 93 460 38 76 E-Mail: info.es@kobold.com Internet: www.kobold.com Edition: March 2013 Page 2 DT0401

2. Note Read this manual before installing the equipment. The equipment should only be used, installed and maintained by people who have this manual and following local regulations on health and safety and risk prevention. 3. Inspection of the instrument All instruments have been checked before packaging and have been shipped in perfect condition. Scope of delivery: Standard equipment includes: Captive air control Model NLP M16 x 1.5 Cable Gland Manual 4. Description The NLP level switch control allows simple and economical liquid level control in various types of unpressurized tanks and vessels 5. Operation The operation is based on measuring the pressure of the captive air inside the measuring tube. When the liquid level covers and then exceeds the bottom of the tube, the resulting increase in air pressure inside the tube acts upon a sensing diaphragm mounted within the head of the device. The switch point is calibrated to change state at 50 mm H20 above the bottom of the tube. DT0401 Page 3

6. Mechanical Assembly Device mounting is performed by the use of an appropriate size fitting into the reservoir. The level device should always be maintained in the upright position. It is very important that the tube always remains totally clean and free of clogging, as level detection failure will result. With the pipe thread option, it is ESSENTIAL that pipe threads have a minimum length of 15 mm and are made so as to ensure uniform pressure on the inner seal to prevent leakage of the captive air inside the tube. 7. Electrical Connection 1- Common 2- N/C 3- N/O 8. Sensitivity Setting The NLP level switch is factory calibrated, thus no user adjustment is required for operation. IMPORTANT: To maintain product warranty, DO NOT TOUCH THE ADJUSTMENT SCREWS! Trigger point: 50 mmh2o Switch-off point: 25 mmh2o Tolerance: ± 10% Page 4 DT0401

9. Technical Information Note: The technical information below is accurate as possible; however, this information is subject to change without notice. Electrical connection: Contact: 6.3 x 0.8 mm SPDT Max. 250Vac, 1A Cable entry: 1 Cable Gland, M16 x 1.5 Sensitivity: Overpressure: Process connection: Measuring tube thread: Media Temperature: Environmental Temp. Membrane: Case Material: Fitting Material: Material tube: Protection: 5 mbar 50 0 mbar G-1, 1" NPT (other connections on request) G-3/8" -10...+85 C -20...+85 C NBR or EPDM Polyamide Polypropylene or PVDF Polypropylene or PVDF IP65 DT0401 Page 5

10. Dimensions 11. Part Number Selection Model Material Connection Tube Length (1) Options NLP- P: Polypropylene T: PVDF 1) Internal thread 2) Tube welded to fitting R: 1 G N: 1 NPT X: Special 0: Without tube (1) 1: 1 Meter (2) 2: 2 Meters (2) 3: 3 Meters (2) X: Special 0: No option Y: Special Option Page 6 DT0401

12. Declaration of Conformity CE Declaration of Conformity EC DECLARATION OF CONFORMITY EG-KONFOMITÄTSERKLÄRUNG Declaration Conformité Conformità DI CE dichiarazione KOBOLD MESURA S.L.U. Avda conflent, 68 08915 Badalona (Spain) Declares under its own responsibility that the product Declares under our sole responsibility, that the product Erklärt in the leiniger Verantwortung, daß das produkt Déclare sous sa seule responsabilité, which produit Dichiara sotto responsabilità itself, che il prodotto NLP To which this declaration relates, are in conformity with the following European Directives: Which Relates To this declaration is in conformity With The Following European Directives: An Erklärung auf das give verweist, sie mit den Richtlinien Europäischen stehen im Einklang folgend: Auxquels one refers À cette déclaration, ils sont aux Directives compliant Européennes suivant : A ai quali if riferisce questa dichiarazione, sono alle direttive europee accordance seguente: EC2006/95/CE Harmonized standards and normative documents applied: Applied Harmonized standards and normative documents: Normen harmonisierte normativer Angewandte Dokumente oder: Norms normatifs harmonisées appliqués et documents Armonizzate and documenti norme applicati normativity: DIN EN 60730-1 (VDE 0631 Teil 1): 2001-09; EN 60730-1:1995 + A1 + A2 + A17 A11bis/to: 2000 DIN EN 60730-2-6 (VDE 0631 Teil 2-6) :1995-10, EN 60730-2-6: 1995 DIN EN 60730-2-6/A1 (VDE 0631 Teil 2-6/A1) :1997-10, EN 60730-2-6: 1995/A1: 1997 Manufactured in: KOBOLD MESURA SLU Avda conflent, 68 08915 Badalona (Spain) Made in: Hergesteltlt in: Fabriqué dans: Fabbricato in: Badalona March 3, 2013 Manager Antonio Sanchez Thomas Measure Kobold SLU Wilfred 655 1st Floor 08918 Badalona Tel: +34 93 460 38 83 Fax: +34 93 460 38 76 E-Mail: info.es @ kobold.com www.kobold.com We reserve the right to change content, without notice. We assume no responsibility for errors DT0401 Page 7