Technical Data. Dimensions

Similar documents
Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR DP 7060 Supplementary Instructions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

EU DECLARATION OF CONFORMITY

MANUAL Oil Level Sensor

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

SEK-3 Marine Grounding System

VERSAFLOW VORTEX Supplementary instructions

4) Intrinsic Safety Certification

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Gas cylinder scale Model GCS-1

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

MANUAL Overflow sensor NVF-104/34-PF

Temperature Measurement Transmitters for field mounting

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Annubar Flowmeter Series

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Operating Instructions Edition 02/2007

IECEx Certificate of Conformity

INSTRUCTION & SERVICE MANUAL

Safety instructions VEGAPULS 64

Assembly. Host Sub-D Alarm

IECEx Certificate of Conformity

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

IECEx Certificate of Conformity

Model 144H. Product Data Sheet , Rev DB February Content

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Manual Power relay SR853

Installation and Operating Instruction

INSTRUCTION MANUAL (ATEX / IECEx)

Certificate of Compliance

Guide for hazardous areas

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Rosemount 752 Fieldbus Remote Indicator

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Dual certification! Air handling units for potentially explosive atmospheres

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Earth-Rite II PLUS Static Earthing System

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

RT FLOW RATE TOTALISER

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

Product Information to the manual

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining


Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Rosemount 2090P Pulp and Paper Pressure Transmitter

DB5 Intrinsically Safe Sounder Type DB-5

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

WIO200 Water In Oil measuring instrument

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

DICTATOR Hold-Open Systems for Hazardous Areas

Model 144H. Product Data Sheet , Rev DB February Content

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

SET Installation and Operating Instructions. Level switch for one sensor

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Certification Supplement Manual

Switches compliant with ATEX directive

Rosemount 3490 Series

INSTRUCTION MANUAL (ATEX / IECEx)

Operating Manual MS220Vi and MSR220Vi

Operating Manual MS220DA

Dräger Polytron 7000 Fixed gas detector

Translation of the assembly instructions with operating instructions and technical appendix

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

User s Manual YTA610 and YTA710 NEPSI Certification

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Transcription:

0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0... 12.15 mm Actual operating distance s r 13.5... 16.5 mm typ. Reduction factor r Al 0.38 Reduction factor r Cu 0.36 Reduction factor r 304 0.7 Nominal ratings Nominal voltage U o 8.2 V (R i approx. 1 kω) Switching frequency f 0... 500 Hz Hysteresis H 1... 15 typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection no Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Switching state indicator LED, yellow Functional safety related parameters MTTF d 3810 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions -25... 100 C (-13... 212 F) Storage temperature -40... 100 C (-40... 212 F) Mechanical specifications Connection type screw terminals Core cross-section up to 2.5 mm 2 Housing material PBT Sensing face PBT Degree of protection IP67 information Use in the hazardous area see instruction manuals Category 1G; 2G; 1D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165 UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions 15 30 LED 4,3x5,3 30 41 20/22 91 M16x1,5 1

Electrical Connection 1 L+ 2 L- 2

ATEX 1G Device category 1G for use in hazardous areas with gas, vapour and mist PTB 00 ATEX 2032 X II 1G Ex ia IIC T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 Ignition protection "Intrinsic safety" and in this instruction manual. The has to be observed. The special conditions must be adhered to! The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. Protection from mechanical danger Electrostatic charge When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. When used in group IIC non-permissible electrostatic charges should be avoided on the plastic housing parts. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Additional requirements for gas group IIC. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. 3

ATEX 2G Device category 2G for use in hazardous areas with gas, vapour and mist PTB 00 ATEX 2032 X II 1G Ex ia IIC T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012 Ignition protection "Intrinsic safety" and in this instruction manual. The has to be observed. The special conditions must be adhered to! The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. Protection from mechanical danger When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. 4

ATEX 1D Device category 1D for use in hazardous areas with combustible dust ZELM 03 ATEX 0128 X Standards Maximum housing surface temperature Electrostatic charge II 1D Ex iad 20 T 108 C (226.4 F) IEC 61241-11:2002: draft; pren61241-0:2002 type of protection intrinsic safety "id" and in this instruction manual. The has to be observed. The special conditions must be adhered to! The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iad. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. The intrinsically safe circuit has to be protected against influences due to lightning. When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. Electrostatic charging due to the flow of media during operation must be excluded. This can be achieved by limiting the surface area of the plastic housing exposed to the electrostatic charging to less than 100 cm 2. 5