INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

Similar documents
INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

CENTRIFUGAL FANS user's manual. model VENTS VK.

Turbo. Service Instructions

Wind. Service instruction

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

AXIAL FANS user's manual. model Quiet

Aero. Service Instructions

Calm. Service Instructions

INTELLIGENT AXIAL FAN user's manual

AXIAL FANS USER S MANUAL

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

USER'S MANUAL PS

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

White - Non Illuminated Art no White - Cool White LED Art no.32600

HEAT RECOVERY AIR HANDLING UNIT

Centrifugal inline fans

USER S MANUAL. VKP Series INLINE FAN

Turbo Inline Fan, White - Non Illuminated Art no.33500

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Axial intelligent fan USER S MANUAL

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

HEAT RECOVERY VENTILATOR

Installation manual Mini Comfort 50 S/L 07/ V EN

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

AH-600 Baseboard Heater

ELECTRIC CONVECTION HEATER WITH FAN AND TIMER

The Family Ceramic Heater

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Low Profile. Baseboard Heater

MINI CERAMIC TOWER HEATER Instruction Manual

Operating Instructions

Air handling unit. BlauAir RH USER S MANUAL

UNDER CABINET RANGE HOOD

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

MINI ELECTRIC CONVECTION HEATER

INFRARED ZONE HEATING SYSTEM

Centrif Duo & Centrif Duo Plus

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

PERSONAL 1500W CERAMIC HEATER Instruction Manual

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

CERAMIC TOWER HEATER Instruction Manual

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

USER S MANUAL DN-2. Drain pump

Infrared Portable Space Heater

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

IMPORTANT SAFETY INFORMATION:

Electric Garage Heater

FOR THE FOLLOWING MODELS : EE-7588R EE-7588W EE-7588O EE-7588B EE-7588M

FAN-FORCED UTILITY HEATER

Gallery Electric Fireplaces

ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

PERSONAL CERAMIC HEATER

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Hardwired Electric Garage Heater

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

INFRARED ZONE HEATING SYSTEM

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

1 HP Air Mover. Owner s Manual

Lo-Carbon Quadra Centrifugal Fan

FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R

IMPORTANT INSTRUCTIONS READ & SAVE

Dr. Infrared Heater Elite Series

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

NO VENTING REQUIRED 120V AC;

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Electric Garage Heater

Homeowner s Installation Instructions & Operating Manual

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

ELECTRIC STOVE HEATER Models: FS2213B

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

Portable Room Air Conditioner and Heat Pump

30-pint Dehumidifier User Guide

16 Stand Fan with Remote Control Model No: FS3-40R-30

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

CERAMIC HEATER MODEL # EE If you have any questions about the operation of your ceramic heater, please contact Crane Customer Care.

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Mobile Air Conditioner Instruction Manual Model TC-N9KM

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

1. GENERAL SAFETY RULES

Transcription:

IIE MIXED-FOW FAS VETS TT SERIES USER'S MAUA www.ventilation-system.com 2011

Read this manual carefully before installation and commissioning of the unit.! READ THE ISTRUCTIOS CAREFUY TO REDUCE THE RISK OF FIRE, EECTRIC SHOCK OR IJURY. WARIG Compliance with the manual requirements ensures reliable fan operation throughout the entire service life. This user's manual contains technical and operating logic description, mounting requirements, servicing and maintenance guidelines for the inline mixed-flow fans TT designed for supply or exhaust ventilation of premises heated during winter time. The fans are made of plastic. The delivery set includes: 1. Fan - 1 pce; 2. Screws and dowels - 4 pcs; 3. User's manual; 4. Packing box. The fans are powered by AC 220-240V, 50-60 Hz single phase current and designed for continuous operation always connected to the electric mains. Ingress protection rating IP X4. The fans are designed both for horizontal or vertical installation and are suitable for individual installation of one unit (fig. 2) or two or more units mounted in series or in parallel (fig.3). The mounting kit components are delivered upon request. An air duct at least 1 meter long must be connected to the intake flange in case of horizontal fan mounting; a cowl must be installed in case of vertical mounting. The intake flange must always be connected to an air duct. Mounting sequence is shown in fig. 4-11. The wiring diagrams are shown is fig. 12-16. Designations: - automatic circuit breaker (fig. 1); S - external switch (fig. 1); X - input terminal. The fans are designed for operation at the temperature range from +0 Ñ up to +40 Ñ. The air temperature in the ventilation system must not exceed +45 Ñ. Automatic circuit breaker designation Automatic circuit breaker Store the fan in manufacturer s packaging in a ventilated room at temperatures between +5 C and +40 C and relative humidity not more than 80% at +25 C. The fans are suitable for connection to 100, 125, 150, 160, 200, 250, 315 mm air ducts. The "S" index fan modifications are equipped with a high-power motor. Air flow direction should match the direction of the arrow on the fan casing. 1 External switch designation S External switch Due to the constant improvements the design of some models may slightly differ from those described in this manual. 2

Any electric connections, adjustment, servicing and repair works are allowed only after the unit is disconnected from power mains. Mounting and maintenance are allowed for duly qualified electricians with valid electrical work permit. The single-phase power grid must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic circuit breaker. The fan must be connected to the power grid through the automatic circuit breaker. The gap between the breaker contacts on all poles must be not less than 3 mm. The overcurrent value shall be equal to the fan current consumption and is indicated on the fan rating plate. Before installation check the fan for any visible damages of impeller and casing. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the device or any unauthorized modifications are not allowed. The unit is not to be used by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the unit operation by the person(s) responsible for their safety. Do not leave the children unattended to avoid their playing with the device. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. The transported air must not contain any dust or other solid impurities, sticky substances or fibrous materials. Do not use the fan in the environment containing hazardous or explosive materials and vapors, i.e. spirits, gasoline, insecticides, etc. Do not close or block the intake and exhaust vents not to disturb the natural air passage. Do not sit or put objects on the unit. This product must be disposed separately after deadline scheduling. Do not throw out this product with unsorted city waste. WARRATY While purchasing the unit the customer accepts the following warranty terms: Manufacturer hereby guarantees normal operation of the unit for 60 months from the date of resale, subject to the compliance with transport, storage, mounting and operation rules. In case of warranty service need submit this user's manual with filled manufacturing date and sales receipt or any other ownership confirmation. The unit modification must match the model stated by the user's manual. In case of non-submittion of the sales receipt or any other ownership confirmation and confirmation of the sales date, warranty period is calculated from the production date. Failure to submit the above documents may result in refuse for free servicing of faulty equipment. All the units and components belonging to the faulty unit and replaced within the warranty period shall be covered by the previous warranty period and general warranty conditions. Thus the warranty period is not extended for the replaced fan components. In case of failure due to faulty equipment during warranty period, the consumer has the right to exchange it. The accessories operated together with the unit, both included and not included into the delivery list as well as other equipment operating jointly with the unit shall not be covered by the warranty. o warranty for compatibility of the fans with other producers' goods. Only manufacturing defects are covered by the warranty terms. All the defects and faults resulting from mechanical effect during operation process or natural wear-and-tear shall not be covered by the warranty conditions. The malfunctions caused by violence of operation, servicing and maintenance guidelines either by Customer or third parties or caused by unauthorized design modifications shall not be covered by warranty. O IABIITY FOR THE REATED DAMAGES: The manufacturer is not responsible for any mechanical or physical damages resulting from the manual requirements violence, the unit misuse or gross mechanical effect. The indirect damages such as re-installation or re-connection of the unit, direct or indirect losses etc related to the unit replacement shall not be indemnified. Mounting/dismantling, connection/disconnection and regulation of the unit shall not be covered by the warranty. The contractor in charge for quality of mounting, electric mounting and adjustment works shall be responsible for the warranty thereof. In any case the indemnity amount shall not exceed the actually paid value for the defective unit price. 3

min1ì 2 3 4

MOUTIG SEQUECE 4 5 6 7 8 9 10 11 5

WIRIG DIAGRAM FOR TT 100, TT 125 fan modifications ~ X 12 14 WIRIG DIAGRAM FOR TT 125S, TT 150, TT 160 fan modifications ~ X 13 WIRIG DIAGRAM FOR TT 200, TT 250, TT 315 fan modifications X ~ 14 WIRIG DIAGRAM FOR TT 100T, TT125T, TT125ST, TT150T, TT160T, TT200T, TT250T, TT315T 18 X ~ 15 16 6

FA COECTIO WITHOUT ITEGRATED TIMER 1. Power the unit off by turning the automatic circuit breaker to OFF position. 2. Release the fixing screws of the terminal block and remove the cover (fig. 18). 3. Release the retaining clip screws and remove the retaining clip (fig. 19). 4. Route the electric cable to the terminal block through the sealed lead-in and fix the cable with a retaining clip and screws (fig. 20). 5. Select the fan operation mode (maximum speed, medium speed, low speed or speed switch with external speed switch). Connect the cables to the input fan terminal block in compliance with the matching wiring diagram and terminal designation inside the terminal box. 6. Install the terminal box cover and fix it with self-tapping screws (fig. 21). 7. Switch the fan on by turning the automatic circuit breaker to O position (fig. 22). The fan starts running at required speed in case of correct electrical connection. If the fan does not operate, troubleshoot the malfunction. 17 18 19 20 21 22 7

FA COECTIO WITH ITEGRATED TIMER 1. Follow all the described above actions, clause 1-4 for fan connection without integrated timer. 2. Connect the cables to the input fan terminal block in compliance with the matching wiring diagram and terminal designation inside the terminal box. 3. Adjust the timer operating time by means of rotating the potentiometer adjusting screws (fig. 23) clockwise to increase the delay time or counter-clockwise to decrease it. 4. Follow the described above actions, clause 6-7 for fan connection without integrated timer. Õ 2 min - + 30 min 23 8

FA MODIFICATIO WITH POWER CORD The "V" index fan modifications are equipped with a three speed switch. The "RV" index fan modification is equipped with a power cord with various plug types and integrated three speed switch. This fan modifiation does not require any mounting operations for connection. The built-in speed switch provides three fan air capacity modes: 0 - fan is off I - low speed operation II - maximum speed operation The"V" and "RV" fan modifications do not include timer modification. MI MAX STOP 24 9

min max tc 24 25 26 23 27 22 28 21 29 20 C 30 C FAS WITH TEMPERATURE AD SPEED COTROER MODUE TSC The TT U fans (fig. 25) enable automatic impeller speed (air flow) control depending on the air temperature in the duct. The "n" index models are equipped with a remote temperature sensor on a4mextension cable. All the fan models with TSC module are equipped with a power cable. The front panel has the following control knobs: - pre-set impeller speed; - thermostat operating threshold; The yellow light indicator on the front panel shows thermostat operation. Timer Operation Algorithm Set the desired thermostat temperature (operating threshold) by turning the thermostat control knob. Set the desired impeller speed (air flow) by turning the impeller speed control knob. On reaching the pre-set air temperature and exceeding the thermostat operating threshold the fan motor switches to the maximum speed (maximum air flow). The fan motor switches to the pre-set speed as the temperature drops below the pre-set thermostat operating threshold. The switching delay function is provided to prevent frequent fan speed changes due to crossing the temperature threshold, especially if the operating temperature is equal to the thermostat threshold value. The switch-off delay operating logic has two versions: TT U (Temperature sensor delay algorithm) On exceeding the pre-set temperature 2 C above the thermostat operating threshold the fan motor switches to the maximum speed. The fan motor reverts to the pre-set speed as soon as the duct temperature drops 2 C below the thermostat operating threshold. This algorithm is used to maintain the desired temperature up to within 2 C. The fan speed changes are rare in this case. TT U1 (Timer delay algorithm) On reaching the pre-set air temperature the motor switches to higher (maximum) speed and the delay timer starts the 5-minute countdown. The fan motor reverts to the previous speed not earlier than 5 minutes after the duct air temperature drops below the thermostat pre-set threshold. This algorithm is used to maintain the desired air temperature precisely. In this mode the fan motor changes its speed more frequent as compared to the temperature sensor delay mode but in any case the switching cycle does not exceed 5 minutes. pre-set impeller speed control knob electronic thermostat operating threshold control knob 25 10

MAITEACE Maintenance (fig. 26-30) means periodic cleaning of the surfaces from dust and dirt. The impeller blades require thorough cleaning every six months. To clean the impeller blades detach the clamps, remove the casing and wipe the blades with warm water and mild detergent solution. Avoid water dripping on the motor while cleaning the blades (fig. 31). MAFUCTIOS AD TROUBESHOOTIG 1. Fan does not get started - broken electric circuit. Check the cable connection to the terminal block. 2. Excessive noise during the fan operation - foreign objects inside the fan casing. Dismantle the fan (fig. 26-29) and remove foreign objects. 3. Excessive vibration during the fan operation - loose fan connection to the wall or the wall is not rigid enough. Check the fan connection. 26 27 28 29 30 31 11

ACCEPTACE IFORMATIO TT 100 TT 125 TT 125S TT 150 TT 160 TT 200 TT 250 TT 315 TT 100T TT 125T TT 125ST TT 150T TT 160T TT 200T TT 250T TT 315T TT 100V TT 100RV TT 125V TT 125RV TT 125SV TT 125SRV TT 150V TT 150RV TT 160V TT 160RV TT 200V TT 200RV TT 250V TT 250RV TT 315V TT 315RV TT 100U TT 125U TT 125SU TT 150U TT 160U 1 n TT 200U TT 250U TT 315U Fan is ready for using. Acceptance stamp Date of production Sold (name of trade enterprise and stamp of the shop) Date of sale www.ventilation-system.com V10(ÒÒ-1) E-06