Indoor Controls. SpaceWise SWZG2. Wireless technology

Similar documents
Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

Savings, control, and comfort without complexity

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

Fixture control made simple

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

EasyAir office sensor advanced grouping SNS200

Sensors. EasySense Outboard-Mount for High Bay

Sensors. EasyAir. office sensor advanced grouping SNS200. Design-in Guide. Single, compact, cost-effective luminaire control

Single, compact, cost-effective fixture control

Single, compact, cost-effective fixture control

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Reduce lighting energy costs with controls

Code Review TITLE PRESENTED BY POURIA NIKNAM

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

Healthcare Title Solutions

High Performance Lighting. Terry Egnor Senior Consultant NBI

Education Title Solutions

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

LIGHTING CONTROLS

Flexible, energy-efficient

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

Office Title Solutions

Hospitality Title Solutions

Wireless Plug Load Control

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Technical Application Guide

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

Restaurants IECC 2015 Solutions

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

A Guide for Applicants and Lighting Designers

Halogen. Energy Advantage Lamps Brochure. Visual appeal with energy savings

Applied Lighting Controls

ANSI/ASHRAE/IES

ANSI/ASHRAE/IES

Restaurants ASHRAE Solutions

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

TENOCHCA HALL - FAN COIL UNITS, RESTROOM AND FINISH RENOVATION PROJECT NO

Wireless Wall-Mount Sensor

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

Maestro 0 10 V Dimmer Sensor

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

HIGH POWER LED RETROFIT MODULE

Mini Product Guide.

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014

VESICA LINEAR SUSPENDED VES L

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

DHL-LP-LED Low Profile LED Linear High/Low Bay

Product Specifications Dialog Room Controller* (*patent pending)

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Fulham s Lighting Controls (LCS) Manage 7 Integrated Lighting Control Strategies

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Optimal control for superior lighting performance

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

Wireless Wall-Mount Sensor

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

LED HIGH BAY LINEAR ECO SERIES

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

, ,

Maestro Occupancy Sensor C L Dimmer

Advanced Lighting Solutions

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Isn t it about time somebody got controls under control?

Retrofitting Billingsley Company office spaces in Dallas, TX

Wireless Wall-Mount Sensor

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

visual environment technologies etcconnect.com

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

IECC. nlight Applications Guide.

ehub Application Note Boardrooms

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

visual environment technologies etcconnect.com

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Dimming Ballast + Controls and CALCTP Bonus. New Product Overview

DIMMING 0-10V Continuous

The Power To Supply... All Your Electrical Products

Code Compliance Commercial Application Guide

LPC3BSP65 & LPC3BDP65

Vive PowPak Fixture Controls

Advanced Lighting For Office

1. Section [ Lighting Control Panel Boards:] Lighting panels (switching) controlled by ControlKeeper

From the Originator and Leader in Integrated Motion Sensor Controls

Ever evolving energy code requirements and the large demand for energy

A flexible and affordable retail toolbox

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

SCS motion sensors Surface/wall mounting - PIR

2015 IECC. Design Guide for Smart Lighting Control and Energy Solutions

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

Never forget to turn the lights off again. Motion Sensors

Spring Seminar The Standard for Lighting Management Quality since

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

Good-Better-Best LED Retrofit Guide

Transcription:

Project: Indoor Controls SpaceWise SWZG2 Location: Cat. No: Type: Lamps: Notes: Qty: Philips luminaires with SpaceWise wireless technology SWZG2 are stand alone LED lighting systems with integrated occupancy sensing and daylight harvesting, designed specifically for office spaces. Automated dimming behaviors are activated after installation using a remote control to create groups and connect wireless switches. Features Occupancy sensing, daylight harvesting and task tuning in one device Granular dimming (occupancy sharing) Dwell Automatic daylight calibration - quickly adapts to any space churn or layout changes Dedicated application modes for office spaces Scene setting Quick tasking tuning in 4 steps - 100%, 88%, 77% and 66% Enables auto-off/manual-on and auto-off/ partial-on application DLC qualified: Listed on the QPL for Networked Lighting Controls Benefits Installation savings - integrated wireless controls with no external components Minimal startup and configuration expertise - savings on labor & effort Deep energy savings & code compliance strategies Faster ROI with attractive payback periods (varies depending on luminiare choices) Applications Conference rooms Individual offices Open offices Classrooms Storage and break areas Restrooms Lobbies Stairways SWZG2_sensor 04/17 page 1 of 5

Product Data All specifications are typical and at 25 C Tcase unless otherwise specified. Electrical Information Input Voltage 120V/277V Frequency 50Hz/60Hz Max Switching Capacity 400VA Standby Power < 1 W Occupancy Sensing Type Passive infrared (PIR) Enable/Disable Default enabled Occupancy Mode Auto-on/off, Manual-on/auto-off; Red LED indicates occupancy detected Group Occupancy Sharing Enabled Group Lighting Behavior Background level, task level Default task level 88% Viewing Angle X=72, Y = 85 ( See detection pattern) Dwell Time Enabled Daylight Sensing Enable/Disable Default enabled Auto-Calibration In office application modes only upon first occupancy detection in the group Viewing Angle 72 Environment & Approbation Operating Ambient Temperature Range 0 C to 55 C Operating Humidity 0 95% non condensing Storage Temperature -25 C to 85 C Storage Humidity 10-95% non condensing Agency Approbations UL, CSA; FCC Other LED Status Indicators Red, Yellow. Yellow LED on: Vacancy & Sensor is functional; Red LED on: Occupancy detected Max Distance Switch-to-First-Fixture 33ft line-of-sight Max Distance Fixture-to-Fixture 33ft line-of-sight No. Switches per Group 5 max Field Configuration via IR remote tool (SWZ REMOTE) SWZG2_sensor 04/17 page 2 of 5

Occupancy Sensing The detection area for the movement sensor can be roughly divided into two parts: Minor movement (person moving 3.0'/s or 0.9m/s). Major movement (person moving 3.0'/s or 0.9m/s). Height Minor Movement Major Movement H Y1 X1 Y2 X2 8.5'/2.6m 17'/5.2m 8.5'/2.6m 17'/5.2m 8.5'/2.6m Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of sensor. SWZG2_sensor 04/17 page 3 of 5

Occupancy Sensing (continued) Task level (Default 88%) Hold Hold Grace fading Fade to task level Grace fading Background level Fade to switch-on Prolong Dwell Prolong Fade to switch-off Occupancy detected Vacancy detected Occupancy detected Vacancy detected Daylight Sensor The light sensor measures the total amount of light in a circular field of 80% of the PIR detection area. The following aspects should be observed during installation: Minimum distance from the window 2.0'/0.6m. Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car bonnet) as this will lead to incorrect light regulation. As a guideline the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the ceiling. Photosensor Spatial Response Light Fixture Window 40 Field of View Typical Daylit Zone, about 12' (3.6m) SWZG2_sensor 04/17 page 4 of 5

Compatible Wireless Switches Manufacturer Model Style Image On/Dim up Philips UID8451/10 Single Rocker Self Powered Off/Dim down Automated dimming based on occupancy and daylight 40% default light output Philips UID8461/10 4 button scene selector 20% default light output Off 2017 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips.com/luminaires SWZG2_sensor 04/17 page 5 of 5 Philips Lighting North America Corporation 200 Franklin Square Drive, Somerset, NJ 08873 Tel. 855-486-2216 Philips Lighting Canada Ltd. 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008