Maestro Occupancy sensing switch

Similar documents
Maestro Occupancy sensing switch

Maestro Occupancy Sensing Switch

Maestro Dual-Circuit Occupancy Sensing Switch

Maestro Occupancy Sensing Switch

Maestro Occupancy Sensor C L Dimmer

Maestro Occupancy sensing switch

Dimmer/Switch with Occupancy and Vacancy Sensor

Lutron Sensor Solutions. Lutron energy-saving light controls for your home or office. simple. affordable. energy-saving.

ViveTM Basic Packages

Maestro Wireless dimmers, switches and sensors

LED Control Solutions. Smooth, flicker-free dimming for every application

Maestro Dimmer - Satin Finish, Incandescent/Halogen, Single-Pole, Clamshell Packaging, 120V/600W In Biscuit

simplicity. convenience. control.

Lutron C L dimmers. Solve the challenges of light bulb compatibility. Works with:

Lutron C L dimmers. Solve the challenges of light bulb compatibility COMING SOON. Nova T* C L. Works with:

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX)

Maestro 0 10 V Dimmer Sensor

GRAFIK T Controls GRAFIK T

lighting control Simple, scalable, wireless Transform existing buildings with wireless lighting controls Wireless controls and sensors

GRAFIK TTM Controls GRAFIK TTM. Wallbox Controls

HomeWorks QS Architectural RF GRAFIK T Local Controls

Native Lighting Control

SPECIFICATION SUBMITTAL

Vive PowPak Fixture Controls

LUTRON 0-10V LIGHT CONTROLS MINIMUM ADVERTISED PRICE POLICY

new GRAFIK Eye QS Customisable preset light and blind control system

A complete drapery track offering to meet all of your application needs

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Wireless Wall-Mount Sensor

Wireless Wall-Mount Sensor

LED Control Solutions

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

Residential Occupancy & Vacancy Sensors

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Wireless Wall-Mount Sensor

HomeWorks QS Palladiom HVAC Solution

Installation Instructions

Save Energy with Unparalleled Total Home Control

Lutron Wireless. Adjust your lights, shades, and temperature from anywhere. Motorized shade. Remote control

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

SPECIFICATION SUBMITTAL

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

ENERGY EFFICIENCY EXPERTS

Quick Install Energy Solutions

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

RA2 Select. Whole home lighting control made simple. Lutron.com/ra2select. Lutron Electronics Co., Inc Suter Road Coopersburg, PA

Lighting and Fan Speed Controls

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Sivoia QS shading solutions. Total Light Control. save energy with LutronTM

Versatile wall switch sensors maximize payback and simplify code compliance

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Quick Install Energy Solutions Featuring Energi TriPak

PRELIMINARY COPY. RadioRA 2. Save energy with wireless total home control from Lutron

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

RadioRA 2. Save energy with wireless total home control from Lutron

Volume 1: Basic devices and single-space systems

Control your lights, shades, and temperature from anywhere. Motorized shade. Smart Bridge

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Vive wireless hub. BACnet Integration. Demand Response

Mini Product Guide.

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Ever evolving energy code requirements and the large demand for energy

Wireless Plug Load Control

Interior Control Solutions

Sivoia QS Shading solutions. Total light control

Discover the power of smart lighting

Product Bulletin for Decora Rocker Slide Controls

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

RadioRA 2. Save energy with wireless total home control from Lutron

Infrared Ceiling Mount Sensor

Infrared Ceiling Mount Sensor

RadioRA 2. Save energy with wireless total home control from Lutron

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

Infrared Wall Mount Occupancy Sensor

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

RadioRA 2. Wireless total home control

600 Watt Dimmer Install Guide

Discover the power of smart lighting

Phase-Adaptive Power Module

design guide for wireless l i g h t i n g c o n t r o l

VESICA LINEAR SUSPENDED VES L

DS160/DS161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions

Commercial Grade Lighting Controls Collection

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Abella Digital Fade Dimmer

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Never forget to turn the lights off again. Motion Sensors

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Transcription:

Maestro Occupancy sensing switch To power the sensing circuit, occupancy sensing switches require a small flow of current when the load is in the OFF state. This can be accomplished by connecting the power supply return wire to ground or to neutral. Local codes in certain municipalities require that a neutral conductor be run to the switch box, regardless of construction. In one particular instance, installing occupancy sensors that use the ground wire to function is not permitted. The MS-OPS6M2U-DV and MS-VPS6M2U products allow the installer to configure the device to connect to either ground or neutral. To connect to ground, simply install the product in its "out-of-the box" condition. To connect to neutral, install the supplied white sleeve over the green wire. For more information about occupancy sensing switches and the National Electrical code, see: www.lutron.com/technicaldocumentlibrary/048469.pdf Features Passive infrared sensors with exclusive Lutron XCTTM Technology for fine motion detection 80 sensor field-of-view Up to 30 ft x 30 ft (9 m x 9 m) [900 ft 2 (8 m 2 )] major motion coverage and 20 ft x 20 ft (6 m x 6 m) [400 ft 2 (36 m 2 )] minor motion coverage Occupancy version can be set to Auto-ON / Auto-OFF or Manual-ON / Auto-OFF Vacancy version available to meet CA Title 24 requirements Adjustable timeout (, 5, 5, or 30 minutes) and high/low sensitivity adjustment 36974a.5.2 Occupancy sensing switch loads: incandescent, halogen, ELV, MLV, CFL, LED, magnetic fluorescent, electronic fluorescent, and fan. Models available MS-OPS6M2U-DV MS-VPS6M2U-DV MS-OPS6M2U-DV MS-VPS6M2U-DV

Specifications Regulatory Approvals UL Listed to U.S. and Canadian safety requirements. NOM Certification (pending). Power 20 277 V~ Key Design Features All lighting loads. Crush/tamper resistant lens. Smart ambient light detection. Adaptive switching algorithm for extended relay life. XCTTM Technology for fine motion detection. Environment Ambient operating temperature: 32 F to 04 F (0 C to 40 C), 0% 90% humidity, non-condensing. Indoor use only. Warranty 5-Year Limited Warranty. For additional Warranty information, please visit www.lutron.com/ TechnicalDocumentLibrary/_Warranty.pdf Additional Information For Maestro Occupancy sensing dimmer models, please see Lutron P/N 369270. For other Maestro Occupancy sensing switch models, please see Lutron P/N 369666. For use with MA-AS, MSC-AS, MA-AS-277, or MSC-AS-277 to control the load from more than two locations, please see Lutron P/N 048435. For more information, please see www.lutron.com/ occvacsensors Lutron Technical Hotline:.800.523.9466. Advanced Features 36974a 2.5.2 Switching Adaptive zero cross feature maximizes relay life by switching at the point of minimum energy on the AC power curve. Actively adapts to variations in relay timing. XCTTM Technology Advanced sensing technology for fine motion detection ensures that the lights stay on while the room is occupied, and that the sensor does not turn on falsely when there is no occupancy in the room. For more information, see www.lutron.com/ TechnicalDocumentLibrary/white%20paper%20 XCT%204-23-09%20B.pdf Maximum current ratings for individual models are provided in the Selection Matrix on page 4.

Custom Settings Ambient Light Detection Lights turn on only if natural light in room is low. Smart Ambient light threshold adjusts precisely to the user s preference. Instructions: If switch turns on when there is enough natural light, or if switch does not turn on when there is not enough natural light, press the large button within 5 seconds of entering the room. Over time, this interaction will teach the switch your preferred setting. Operation Occupancy / Vacancy: Auto-ON / Auto-OFF or Manual-ON / Auto-OFF Vacancy only: Manual-ON / Auto-OFF only Timeout Options (See Additional Features on page 4 for default settings) Minute 5 Minutes 5 Minutes 30 Minutes Sensitivity Options High sensitivity (default) Low sensitivity 36974a 3.5.2 Manual Off-While-Occupied Options (MS-OPS only see Additional Features on page 4 for default setting) Enabled When the Occupancy sensing switch is manually turned off, the Occupancy sensing switch will not turn the lights back on automatically while the room is occupied. Once the room is vacated, the Auto-ON feature returns to normal operation after the timeout period has expired. This may be the preference in conference rooms or classrooms while viewing presentations. This feature requires motion to keep the lights off. Disabled When the Occupancy sensing switch is manually turned off, the Auto-ON feature will return to normal operation after 25 seconds. This may be the preference if the user always wants the lights to turn on upon entering and the lights to turn off when the room is vacant. Auto-ON Options (MS-OPS only) Occupancy (default): Auto-ON / Auto-OFF Vacancy*: Manual-ON / Auto-OFF Low Light: Lights turn on only if needed (if ambient light is below threshold) * There is a 5-second grace period that begins when the lights are automatically turned off, during which the lights will automatically turn back on in response to motion. This grace period is provided as a safety and convenience feature in the event that the lights turn off while the room is still occupied, so that the user does not need to manually turn the lights back on. After 5 seconds, the grace period expires and the lights must be manually turned on.

Selection Matrix 36974a 4.5.2 Model Number Vacancy only 2 (Title 24 compliant) Single-pole only Works with standard mechanical 3-way switch 3 Works with companion switch 3, 4 All lighting loads (20 V~ only) All lighting loads (20 277 V~ only) Fan (20 V~) MS-OPS6M2U-DV-XX 6 A 3 A 3 A MS-VPS6M2U-DV-XX 6 A 3 A 3 A Light + Fan (20 V~) or ground wire required for functionality 5 Minimum load required Single-pole / 3-way capability Max current rating Off-state power XX in model number represents color/finish code. 2 Occupancy sensors can be configured as Auto-ON / Auto-OFF or Manual-ON / Auto-OFF. Vacancy sensors are configured as Manual-ON / Auto-OFF only. 3 Standard mechanical 3-way switch cannot be combined with companion switch. 4 Companion switch MA-AS, MSC-AS, MA-AS-277, or MSC-AS-277 is required for multi-location installations (more than two locations controlling the same lighting circuit). Up to nine companion switches may be connected. 5 The green wire can be connected to ground or, when covered by the white sleeve, can be connected to neutral (see illustrations on page 7). Additional Features Crush/tamper-resistant lens Ambient light detection Switching XCTTM technology Manual off-while-occupied default setting Default timeout (minutes) Model Number MS-OPS6M2U-DV-XX Smart Adaptive Enabled 5 MS-VPS6M2U-DV-XX Smart Adaptive 5 XX in model number represents color/finish code. Job Name: SPECIFICATION SUBMITTAL Page Model Numbers: 4 Job Number:

Occupancy Sensing Switch Placement and Operation 36974a 5.5.2 The ability of the Occupancy sensing switch to detect motion requires line-of-sight of room occupants. The Occupancy sensing switch must have an unobstructed view of the room. Hot objects and moving air currents can affect the performance of the Occupancy sensing switch. The performance of the Occupancy sensing switch depends on a temperature differential between the ambient room temperature and that of room occupants. Warmer rooms may reduce the ability of the Occupancy sensing switch to detect occupants. Definitions Major motion: movement of a person entering or passing through an area. Minor motion: movement of a person occupying an area and engaging in small activities (e.g., reaching for a telephone, turning the pages of a book, opening a file folder, picking up a coffee cup). NEMA WD7 Coverage Horizontal Beam Diagram 5 ft (4.5 m) 0 ft (3 m) 5 ft (.5 m) 0 5 ft (.5 m) Major motion coverage: 900 ft 2 (8 m 2 ) Minor motion coverage: 400 ft 2 (36 m 2 ) 30 ft (9 m) 25 ft (7.5 m) 20 ft (6 m) 5 ft (4.5 m) 0 ft (3 m) 5 ft (.5 m) 0 5 ft (.5 m) 0 ft (3 m) 5 ft (4.5 m) 20 ft (6 m) 25 ft (7.5 m) 30 ft (9 m) 0 ft (3 m) Vertical Beam Diagram 5 ft (4.5 m) 4 ft (.2 m) 0 5 ft 0 ft (.5 m) (3 m) 5 ft (4.5 m) 20 ft (6 m) 25 ft (7.5 m) 30 ft (9 m) 0 5 ft (.5 m) 0 ft (3 m) 5 ft (4.5 m) 20 ft (6 m) 25 ft (7.5 m) 30 ft (9 m) Job Name: SPECIFICATION SUBMITTAL Page Model Numbers: 5 Job Number:

Dimensions Measurements shown as: in (mm). Front View Side View 36974a 6.5.2 4 6 (9) 2 5 6 (75) 5/6 (8) /8 (3) 8 (30) Mounting Operation Mounting screws Adapter mounting screws Tapswitch Tap on / off Lens Wallbox Occupancy Sensing Switch Wallplate Adapter / Wallplate (sold separately) MS-OPS6M2U-DV MS-VPS6M2U-DV LED (behind lens) Pulses during configuration of custom settings and in the Test mode.

Converting Wire to Wire 36974a 7.5.2 The green wire can be connected to ground or, when covered by the white sleeve, can be connected to neutral. : always connect to ground Slide white sleeve over green wire until flush with back cover. (hot/switched hot) (3-way) (connects to ) White sleeve White (connects to )

Wiring Diagrams: Single-Location Installations Wiring Diagram : Connect occupancy sensing switch to ground Single-Location Installation (20-277 V~), 2 -OPS6M2U-DV 3, -VPS6M2U-DV 3 Occupancy sensing switch 36974a 8.5.2 20-277 V~ Wiring Diagram 2: Connect occupancy sensing switch to neutral Single-Location Installation (20-277 V~), 2 -OPS6M2U-DV 4, -VPS6M2U-DV 4 Occupancy sensing switch 20-277 V~ White When using controls in single location installations, tighten the blue terminal or cap blue wire. Do NOT connect the blue terminal / wire to any other wire or to ground. 2 Fan load applies to 20 V~ only (not for use with 277 V~). 3 wire is connected to ground. 4 Wire covered by white sleeve is connected to neutral.

Wiring Diagram 3: Connect occupancy sensing switch to ground 3-way Installation with Standard Mechanical 3-way Switch (20-277 V~) -OPS6M2U-DV 4, -VPS6M2U-DV 4, 2, 3 36974a 9.5.2 Wiring Diagrams: 3-way Installations with Standard Mechanical 3-way Switch Standard mechanical 3-way switch Occupancy sensing switch Jumper wire 20-277 V~ screw Different color screw (Common) OR Occupancy sensing switch Standard mechanical 3-way switch Jumper wire 20 V~ screw Different color screw (Common) Only one Occupancy sensing switch can be used per multi-location circuit. 2 A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches. Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 50 ft (46 m). 3 Fan load applies to 20 V~ only (not for use with 277 V~). 4 wire is connected to ground.

36974a 0.5.2 Wiring Diagrams: 3-way Installations with Standard Mechanical 3-way Switch (continued) Wiring Diagram 4: Connect occupancy sensing switch to neutral 3-way Installation with Standard Mechanical 3-way Switch (20-277 V~) -OPS6M2U-DV 4, -VPS6M2U-DV 4, 2, 3 Standard mechanical 3-way switch Occupancy sensing switch Jumper wire 20-277 V~ screw Different color screw (Common) White OR Occupancy sensing switch Standard mechanical 3-way switch Jumper wire 20 V~ White screw Different color screw (Common) Only one Occupancy sensing switch can be used per multi-location circuit. 2 A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches. Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 50 ft (46 m). 3 Fan load applies to 20 V~ only (not for use with 277 V~). 4 Wire covered by white sleeve is connected to neutral.

Wiring Diagrams: Multi-location Installations Wiring Diagram 5: Connect occupancy sensing switch to ground Multi-Location Installation (20 V~), 2, 3 -OPS6M2U-DV 4, -VPS6M2U-DV 4 36974a.5.2 MA-AS or MSC-AS MA-AS or MSC-AS Occupancy sensing switch 3 Brass Brass 20 V~ Wiring Diagram 6: Connect occupancy sensing switch to neutral Multi-Location Installation (20 V~), 2, 3 -OPS6M2U-DV 5, -VPS6M2U-DV 5 with MA-AS or MSC-AS MA-AS or MSC-AS MA-AS or MSC-AS Occupancy sensing switch 3 Brass Brass 20 V~ White Only one Occupancy sensing switch can be used per multi-location circuit. 2 A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches. Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 50 ft (46 m). 3 Occupancy sensing switch can be installed in any location. 4 wire is connected to ground. 5 Wire covered by white sleeve is connected to neutral.

36974a 2.5.2 Wiring Diagrams: Multi-location Installations (continued) Wiring Diagram 7: Connect occupancy sensing switch to ground Multi-Location Installation (277 V~), 2, 3, 4 -OPS6M2U-DV 5, -VPS6M2U-DV 5 with MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 Occupancy sensing switch 3 Red Red 277 V~ Wiring Diagram 8: Connect occupancy sensing switch to neutral Multi-Location Installation (277 V~), 2, 3, 4 -OPS6M2U-DV 6, -VPS6M2U-DV 6 with MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 Occupancy sensing switch 3 Red Red 277 V~ White Only one Occupancy sensing switch can be used per multi-location circuit. 2 A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches. Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 50 ft (46 m). 3 Occupancy sensing switch can be installed in any location. 4Fan load applies to 20 V~ only (not for use with 277 V~). 5 wire is connected to ground. 6 Wire covered by white sleeve is connected to neutral.

Colors and Finishes Gloss Finishes Satin Finishes 36974a 3.5.2 White WH Ivory IV Hot HT Merlot MR Plum PL Turquoise TQ Almond AL Light Almond LA Taupe TP Eggshell ES Biscuit BI Snow SW Gray GR Brown BR Palladium PD Midnight MN Sienna SI Terracotta TC BL briar GB stone BG Mocha Stone MS Goldstone GS Desert Stone DS Stone ST Limestone LS Sea Glass SG Due to printing limitations, colors and finishes shown cannot be guaranteed to match actual product colors perfectly. Color chip keychains are available for more precise color matching: Gloss Finishes: DG-CK- Satin Finishes: SC-CK-