Redring Powerstream Electric Flow Boilers. Efficient, safe and convenient electric space and water heating

Similar documents
H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Amptec. Electric flow boiler

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Water Heating Systems

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

the electric heating company ELECTRIC BOILER HANDBOOK

Combined electric boiler and domestic hot water store

Where gas is not an option,

ADVANCE ECB ELECTRIC COMBINATION BOILER

Exceeding the Standard

The Ultimate Solution for Electric Central Heating. Fusion. Comet

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Baxi Maxflow Combi WM

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

H ot Wa te r Syste m s. Copper Hot Water Products. Total Hot Water Solutions

Total Hot Water Solutions

ADVANCE ELECTRIC THERMAL STORE

heat interface units A BOILER WITHOUT A FLAME

SOLAR HEATING SYSTEMS

Stored Water District Heating Interface Units. Heat Interface Units

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

EFFICIENCY THERMAL STORAGE SYSTEMS

Exceeding the Standard

Efficient heating that won t cost the earth

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

Kills bills. How Vaillant technologies reduce home heating bills

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

VENTED CYLINDER RANGE

Baxi Maxflow Combi FS

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Unvented Water Heating. Zircon

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

thermocompact High performance system boiler range

ecotec plus New high efficiency condensing combination and system boiler ranges

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

unistor High performance unvented stainless steel cylinder range

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Unvented water heating

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Harlequin HeatStream Case Study

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

2015 PRODUCT RANGE GUIDE

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

unistor High performance unvented stainless steel cylinder range

Broag Pressurisation equipment

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

New Zealand Sales Hotline: Sales Fax:

Performance on demand

INSTALLATION & TECHNICAL MANUAL

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Risk Assessment and Control Measures for Household Hot Water Systems

UNVENTED STAINLESS STEEL CYLINDERS

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Electromax. Combined electric boiler and domestic hot water store

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Link-Up. Solid Fuel Association Guide to Central Heating.

Electronic Dual Cylinder Thermostat Installation Instructions

Cistern-fed water heating

INTERCYL. INTERNAL EXPANSION EXCELLENCE

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

Instructions for Use Installation and Servicing

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Sirius FS. Working towards a cleaner future

INSTALLATION & TECHNICAL MANUAL

Marble Arch, Chandigarh

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

MAXIMISER Semi-Storage Calorifiers

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

WASHROOM. Solutions Super fast, super efficient... UK market leaders in washroom solutions for over 45 years.

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Frequently Asked Questions

maximise the sun s energy with warmflow solar Warmflow Solar

POINT OF USE WATER HEATERS

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Installation and User Guide Please leave this guide with the end user (for future reference)

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

TERMO ELECTRIC BOILER INSTALLATION MANUAL OSO TERMO RS -M

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Stainless Steel Unvented Cylinders

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

VORTEX BLUE OIL RANGE

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Transcription:

Redring Powerstream Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Stylish and electric Electric flow boilers Redring electric flow boilers provide wet central heating (and domestic hot water if required) and are ideal for homes and light commercial premises. They are ideal for use in areas with no mains gas supply and offer the convenience of electric heating combined with the comfort and controllability of conventional central heating. They can also be installed in place of boilers using oil, bottled gas or solid fuel or as an alternative to electric storage heating. Powerstream boilers are suitable for use with sealed or open vented heating systems and with underfloor heating. They require no external flue and are easily fitted in confined spaces such as kitchen cupboards or airing cupboards without an external wall. They are 99% efficient and users benefit from the fact that they require no annual servicing or safety check. When supplied with electricity from renewable sources on a green tariff they provide a totally sustainable source of heating and hot water. Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Redring offers two stylish electric Powerstream flow boiler models to meet a wide range of requirements. Key Features: Powerstream Ascari Integral circulation pump and expansion vessel Auto-adaptability - minimising energy input, smoothes temp. variation of the home and on/off cycling of the boiler Suitable for sealed and open vented systems, with radiators or underfloor heating Choice from 12, 8, 6 or 4kW on installation Compact design - fits into most spaces (including kitchen cupboards) Low maintenance - no requirement for annual service or safety check (5 year check) Near silent operation Selectable heating system water temperature, 21 C - 80 C - allows low energy setting of heating Cast iron engine for thermal stability Ideal for well insulated properties of up to 80m 2 5 litre water storage, for rapid response X years guarantee Key Features: Powerstream Professional 7 models are available with different kw ratings (2kW - 12kW) Compact design - fits into most spaces (including kitchen cupboards) Solid state technology for long-life No moving parts maximum reliability Minimal service and maintenance costs Suitable for sealed and open vented systems with radiators or underfloor heating Uses standard radiators, programmer, pump, room stat and thermostatic radiator valves Thermostatic range 30 C to 55 C (underfloor) or 55 C to 80 C (central heating) External circulation pump and expansion vessel required X years guarantee Logic Certification Redring supports installer training through Logic Certification - a UKAS accredited body able to offer certification services under the Accredited Certification Scheme (ACS) through a network of approved training and assessment centres around the UK. Logic Certification has developed specific courses on the installation of Redring Powerstream electric flow boilers and also provides more general training in plumbing and electrical installation and commissioning. For details, and to find a training and assessment centre near you, visit www.logiccertification.com www.redring.co.uk 3

Simple to use controls with digital LED display Redring Powerstream Ascari When it comes to style and performance, the Powerstream Ascari electric boiler leads the field. By incorporating an integral circulation pump and expansion vessel in the one unit, the Powerstream Ascari looks incredibly stylish and can be installed on display on a wall or in a kitchen cupboard. It has a sophisticated control system which maximises energy efficiency at 99% by minimising energy input and on/off cycling of the boiler. The built in 5-litre hot water storage tank also allows for a rapid response to changing demands. The Powerstream Ascari is an advanced one fits all electric boiler solution as the kw rating of the one model can be configured from 4 to 12kW s depending on your requirements. The Powerstream Ascari also comes complete with a soft touch control panel and LED digital display that provides the user with information on the boiler status and allows for the programming of many functions quickly and easily. Suitable for use with a wide range of different heating systems, the Powerstream Ascari can provide a water output temperatures from 21 O C to 80 O C perfect for underfloor heating and standard radiators. You can even keep your existing thermostatic radiator valves, room thermostats and programmers to provide central heating that gives high levels of comfort and control. Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Control Panel Inside the Powerstream Ascari 1 5 4 3 5 2 6 6 2 3 7 4 8 1 7 1 Boiler operating LED 2 Decrease system temperature command 3 Heating circuit water pressure display (bar) 4 On/off command 5 Temperature display heating water (in C) 6 Increase system temperature command 7 Heating temperature command 8 Operating mode selector 1 Lorem ipsum dolor sit amet 2 Aenean cursus hendrerit nibh 3 Duis risus tortor 4 Proin accumsan sem aliquet enim 5 Nunc tempor nunc sed sem cursus 6 Proin rhoncus nulla at elit ultrices 7 Nunc urna urna 8 Pellentesque viverra Intelligent Control The Powerstream Ascari boiler has been designed to provide the highest temperature stability and energy consumption possible from an electric boiler. Its 5 litre storage and high thermal mass reduce system cooling, while its electronic temperature and auto-adaptability function keep the room at a stable temperature using the least amount of electrical energy. The optional outside temperature sensor allows the boiler to quickly adapt to the external temperatures, increasing heat output on cooler days and reducing energy on warmer days, keeping temperature and energy completely under control. Running Costs The Powerstream Ascari boiler is fitted with an auto-adaptability function that operates the central heating system according to the heat characteristics of the property, minimising energy consumption and running costs. The Ascari is designed for use with extended hours off-peak tariffs. Please ask your energy supplier for details of optimum tariffs. www.redring.co.uk 5

Efficient and excellent value Redring Powerstream Professional Our entry level electric flow boiler is the 99% efficient and excellent value Powerstream Professional. Depending on your property size and heating system, you can choose the correct Powerstream Professional to meet your needs as there are seven models available in the range with kw ratings from 2 to 12kW s. Suitable for use with a wide range of different heating systems, all Powerstream Professional models can provide a water output temperatures from 30 O C to 90 O C, meaning they can be combined with underfloor heating and standard radiators. You can even keep your existing thermostatic radiator valves, room thermostats and programmers to provide central heating that gives high levels of comfort and control. All Powerstream Professional boilers require an external pump and expansion vessel to be fitted as part of the installation, which makes them ideal for out of sight installations for example in an airing cupboard or utility room. Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Control Panel Inside the Powerstream Professional 1 3 2 3 SUPPLY CALL 4 2 TEMP 4 5 ALARM 1 5 1 Supply: Green when power is connected to boiler (on all the time) 2 Call: Green when heat is being demanded (i.e. the room or hot water requires heating). Red indicates there is a fault 3 Four orange lights showing the level being supplied Level is set automatically by the boiler according to conditions (1 light is min. 4 lights is max) 4 Use the dial to set the maximum boiler temperature (the room and hot water temperatures are usually set by separate controls elsewhere in the property) 5 Alarm: Red indicates that the boiler has overheated (An internal cut-out requires ressetting by the installer) 1 Lorem ipsum dolor sit amet 2 Aenean cursus hendrerit nibh 3 Duis risus tortor 4 Proin accumsan sem aliquet enim 5 Nunc tempor nunc sed sem cursus 6 Proin rhoncus nulla at elit ultrices 7 Nunc urna urna 8 Pellentesque viverra www.redring.co.uk 5

Dimensions and Application Powerstream Ascari 405mm 280mm Product Range Product Reference Short Code Cat. No Powerstream Ascari PSA12 4555186 *Building Regulations apply. 620mm 300mm 100 10 10 Technical Filling Loop The Powerstream Ascari is not fitted with a filling loop. Any filling loop being fitted should comply with the Water Supply (water fittings) Regulations 1999 Section G24.1 and G24.2. A filling loop should be fitted at some point to allow the CH system to be filled. Parallel Operation For larger properties, multiple boilers may be installed in parallel. Hot Water Storage Ask for the Redring Aqualoy LWSS 2304 Duplex Stainless Steel water storage heaters that provide effective, fast and safe hot water for baths, showers and other domestic appliances around any property. For use with direct and indirect heating applications the Aqualoy LWSS cylinders are a high quality vessel employing the best in tig welding technology, the LWSS range also features high flow rates and energy efficient insulation. Technical Specification Maximum power 4-12kW I Includes 8 litre expansion vessel, 3bar pressure relief valve and 3-speed pump for quick easy install I 7-segment digital displays of temperature and pressure I Graduated power on/off reduces instantaneous loads I Frost protection 5 C minimum system temperature I 5 litre water storage I Pump protection, prevents pump sticking I Stainless steel elements I Operating pressure 0.5bar - 3bar I Top or bottom cable entry. Electrical The Powerstream Ascari should be permanently connected to the electrical supply through a double linked switch with minimum breaking capacity for the loading. All wiring should be installed to conform to the current edition of the IEE Wiring Regulations. Did you know? Powerstream Ascari and Powerstream Professional electric flow boilers may also be used to supplement alternative energy systems (such as solar thermal heating) to maintain water temperature when the alternative energy system cannot meet the total heat demand. Solar Panel R Heating Output Powerstream Ascari or Powerstream Professional Complementing an alternative energy system To maintain heating temperature when alternative energy source cannot supply enough heating. Heating Input Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Plumbing Schemes Powerstream Ascari Key Programmer and Room Thermostat Water Pump Regulator Heating only Radiators or floor heating system. TA Heating and domestic hot water Redring recommend to use a direct electric unvented cylinder for the production and storage of the hot water as this is cheaper than an indirect cylinder, requires less plumbing (pipes and valves) and is more thermally efficient. When using the boiler for unvented hot water and heating, the two-port motorised valve should be inserted in the flow from the boiler. A Differential Pressure Valve should be connected between the flow and return at a point between the boiler and the two-port motorised valve. Room Thermostat Hot Water Outlet Air Bleeders Two Port Valve Differential Pressure Valve Air Bleeders 3 Port Diverter Valve Cylinder Thermostat 3 Speed Pump 3 Bar Pressure Relief Valve or Underfloor Heating 8 Litre Expansion Vessel Manifold Switched Live www.redring.co.uk 7

Dimensions and Application Powerstream Professional Product Range Product Reference Short Code Cat. No 396mm Powerstream Pro 2kW RFB2 45670202 Powerstream Pro 4kW RFB4 45670204 Powerstream Pro 6kW RFB6 45670206 Powerstream Pro 7.5kW RFB75 45670207 Powerstream Pro 9kW RFB9 45670209 Powerstream Pro 10.5kW RFB105 45670210 Powerstream Pro 12kW RFB12 45670212 *Building Regulations apply. 86 238mm Boiler Temp. BTU kw loading Cable size Fuse rating variant range output @ 230-240V guide guide RFB2 30-80 6830 1.8-2 1.5mm 2 13 Amps RFB4 30-80 13660 3.7-4 2.5 / 4mm 2 20 Amps RFB6 30-80 20490 5.5-6 4mm 2 30 Amps RFB75 30-80 25613 6.9-7.5 4 / 6mm 2 35-40 Amps RFB9 30-80 30735 8.3-9 6 / 10mm 2 40-45 Amps RFB105 30-80 35860 9.6-10.5 6 / 10mm 2 45 Amps RFB12 30-80 40980 11-12 10mm 2 50 Amps 69 Outlet 386mm 49 Inlet Boiler sizing Please consult your installer/heating engineer/designer as to the correct size of the Powerstream Professional boiler. Size of the property, the insulation properties of the building itself, the local and seasonal weather conditions and exactly what the boiler will be required to heat, eg: heating and/or hot water will need to be considered. To discuss individual delivery and design requirements or for help with making your selection please call: Technical - 08709 000430 or email: Design - aedesign@applied-energy.com Selection Guide (Based on NHBC guidelines 1 ) Property Max. floor area Space Heating only 2 Type (m 2 /ft 2 ) New Build Older properties 1 room bedsit 20 / 200 RFB2 RFB4 2 room flat 40 / 400 RFB4 RFB6 1 bed house 80 / 800 RFB6 RFB105 2 bed house 100 / 1000 RFB6 RFB12 3 bed house 130 / 1400 RFB9 n/a 4 bed house 150 / 1600 RFB9 n/a 5 bed house 190 / 2000 RFB12 n/a Property Space Heating & Indirect Hot Water 3 Type Tank (l) Wash New Build Older properties 1 room bedsit 50 1 shower RFB4 RFB6 2 room flat 115 1 bath RFB75 RFB9 1 bed house 115 1 bath RFB9 n/a 2 bed house 115 1 bath RFB105 n/a 3 bed house 115 1 bath RFB12 n/a 4 bed house 140 1 bath RFB12 n/a 5 bed house 200 2 baths n/a n/a NB 1 In broad terms, stipulates minimum room temperatures and recovery times for typical hot water draw-offs 2 Based on average space heating requirement of 45 W/m 2 (New Build), 90W/m 2 (Older properties) 3 Includes requirement for a complete tank full recovery time of less than 3 hours. Did you know? Powerstream Ascari and Powerstream Professional electric flow boilers may also be used to supplement alternative energy systems (such as solar thermal heating) to maintain water temperature when the alternative energy system cannot meet the total heat demand. Solar Panel R Heating Output Powerstream Ascari or Powerstream Professional Complementing an alternative energy system To maintain heating temperature when alternative energy source cannot supply enough heating. Heating Input Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Technical Powerstream Professional For Heating only, with Direct domestic hot water cylinder For Underfloor Heating system For Heating and domestic hot water & Indirect hot water cylinder S Plan System Y Plan System * Expansion kit not required on a vented system Hot Water Storage Ask for the Redring Aqualoy LWSS 2304 Duplex Stainless Steel water storage heaters that provide effective, fast and safe hot water for baths, showers and other domestic appliances around any property. For use with direct and indirect heating applications the Aqualoy LWSS cylinders are a high quality vessel employing the best in tig welding technology, the LWSS range also features high flow rates and energy efficient insulation. NB he Redring Powerstream Professional flow boiler is ideal for providing water to a domestic /light commercial wet central heating system. Where it is intended for use to provide hot water as well, it may be that an alternative direct source of heat is required, eg: immersion heater. This is to ensure compliance with NHBC guidelines and to provide hot water at all times. NB2 The Redring Powerstream Professional flow boiler requires fitment of a circulating pump for underfloor and central heating applications. In the case of unvented applications an expansion kit will be required. UK manufactured in a BS EN ISO 9001:2000 registered factory. Technical Specification Thermostatic temperature range 30 C to 55 C (underfloor) or 55 C to 80 C (central heating) I UK manufactured in a BS EN ISO 9001:2000 registered factory. www.redring.co.uk 7

UK Sales Sales Hotline 0844 372 7750 Sales Fax 0844 372 7760 Technical Services Techline 0844 372 7766 Techfax 0844 372 7767 International Sales Redring is a great British brand in every sense of the word. It is also a world leader in electric heating and hot water demanded in over twenty countries worldwide. Redring has achieved this by taking into consideration global market requirements and ensuring products are developed to meet these needs, as well as developing products for specific countries and regions, taking into consideration approvals, electrical supply and climate. For further details call: Sales Hotline +44 (0) 1733 456789 Sales Fax +44 (0) 1733 456727 Applied Energy Products Ltd Morley Way Peterborough PE2 9JJ t +44 (0) 844 372 7761 f +44 (0) 844 372 7762 www.redring.co.uk info@redring.co.uk www.youtube.com/user/redringsolutions www.twitter.com/redringsolution R043 April 2010 All Redring products, unless otherwise stated, are covered by a full parts and labour guarantee for 1 year from the date of purchase, so should the product become faulty within the guarantee period, it will be replaced with a new product or repaired by our service engineers, totally free of charge. Redring reserve the right to alter product specification or appearance without prior notice. All finishes in the brochure are as accurate as printing processes allow. 04/2010 Applied Energy Products. All rights reserved