INSTALLATION INSTRUCTIONS

Viking Installation Guide

Installation Guide. 5 Series Professional Built-In Electric Single and Double Ovens 7 Series Professional Built-in Electric Double French Door Oven

Viking Installation Guide

Installation. Professional Built-In Electric Single and Double Ovens. Professional Built-In Electric Single and Double French Door Ovens

Installation GUIDE 6 SERIES. Built-in Electric Single and Double Wall Ovens MVSOE630 / CMVSOE630 MVDOE630 / CMVDOE630

Viking Installation Guide

Viking Installation Guide

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION

Installation. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models)

Installation GUIDE 5 SERIES. Warming Drawer VWD527 VWD530

Installation. Guide. 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730

INSTALLATION INSTRUCTIONS

Installation. Built-In Electric Cooktop. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation. Freestanding 30 Gas Self-Clean Sealed Burner Range

Tuscany Freestanding Dual Fuel Ranges

Installation. 3 Series Built-In Electric Cooktop RVEC330 / CRVEC330 RVEC336 / CRVEC336 RVEC345 / CRVEC345

Viking Installation Guide

Installation. 3 Series Freestanding 30 Dual Fuel Self-Clean Sealed Burner Range

GUIDE. Installation. Tuscany Freestanding Dual Fuel Ranges

Viking Installation Guide

Viking Installation Guide

Installation Guide. Built-In Electric Cooktops Built-In Induction Cooktops

Installation. Professional Freestanding Open Burner Ranges VGIC5301, CVGIC5301, VGIC5361, CVGIC5361

GUIDE. Installation 5 SERIES. Built-In Electric Cooktops Built-In Induction Cooktops

Viking Installation Guide

Installation. Professional Freestanding Dual Fuel Ranges VDSC530 / VDSC536 / VDSC548 / VDSC560 CVDSC530 / CVDSC536 / CVDSC548

DESIGN CLASS FUNCTION

Installation. Professional Freestanding Sealed Burner Gas Ranges VGCC530 / VGCC536 / VGCC548 / VGCC560 CVGCC530 / CVGCC536 / CVGCC546 / CVGCC560

Installation. Professional Freestanding Ranges

Viking Installation Guide

Viking Installation Guide

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Viking Installation Guide

Viking Installation Guide

Installation Instructions Part No

Viking Installation Guide

INSTALLATION INSTRUCTIONS

Installation Instructions Part No

SPECIFICATIONS - INDUCTION/RADIANT COOKTOP Description 30 W. VCCU 36 W. VCCU. SPECIFICATIONS - ALL INDUCTION COOKTOP Description 30 W. VICU 36 W.

Viking Installation Guide

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

Viking Installation Guide

Viking Installation Guide

Installation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515

Viking Installation Guide

INSTALLATION INSTRUCTIONS

Installation Guide. 15 W./24 W. Undercounter Refrigeration

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA

INSTALLATION INSTRUCTIONS

Installation. Built-in Full Height Wine Cellar VCWB301

Viking Installation Guide

INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation. 15 W. / 24 W. Undercounter Refrigeration

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

Viking Installation Guide

Viking Installation Guide

Installation Guide. Outdoor Gas Grills. Viking Range, LLC. 111 Front Street. Greenwood, Mississippi USA (662) For product information,

Viking Installation Guide

Installation. Outdoor Gas Grills

Viking Installation Guide

Installation Instructions 30 French Door Built-in Wall Ovens

USE/INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

2 PREPARE THE OPENING

Installation. Counter-Depth Freestanding French Door Bottom-Mount Refrigerator/Freezer

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) RETAIN THIS MANUAL FOR FUTURE REFERENCES.

Advantium TM. Built-In. Speedcook Ovens. Installation. Instructions

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

TRI-STAR INC SOUTH STANDARD AVENUE, SANTA ANA, CA Ph: Fax: MODEL #. OWNER S MANUAL

Viking Use/Installation Guide

Viking Installation Guide

30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

Professional Warming Drawer and Warming Drawer Cabinet

Installation. All Refrigerator / All Freezer VCRB5303 / VCRB5363 / CVCRB5303 / CVCRB5363 VCFB5303 / VCFB5363 /CVCFB5303 / CVCFB5363

Installation Instructions

Service Manual Electric Cooktop

Viking Installation Guide

INSTALLATION INSTRUCTIONS

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RRE SERIES (ELECTRIC RANGE & CONVECTION)

Viking Installation Guide

OWNER S MANUAL INSTALLATION OPERATION MAINTENANCE CONVECTION OVEN MODEL # RDCO-32

Viking Use/Installation Guide

INSTALLATION INSTRUCTIONS

Viking Use/Installation Guide

Installation Instructions Wall Ovens

Installation Instructions

OWNER S MANUAL PREMIER SERIES HIGH PERFORMANCE ELECTRIC CONVECTION OVEN. MODELS: m 3000 m 3092

Installation Instructions

Installation Instructions

Installation Instructions

Owner s Guide Installation & Operation

Viking Installation Guide

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

Transcription:

Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com Professional Built-In 36 Electric Ovens F20241K EN (052709 J)

IMPORTANT: PLEASE READ AND FOLLOW 1. Before beginning, please read these instructions completely and carefully. 2. Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty. 3. Please observe all local and national codes and ordinances. 4. Please ensure that this product is properly grounded. 5. The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference. Installation must conform with local codes or in the absence of codes, the National Electrical Code, ANSI/NFPA 70 - latest edition. IN CANADA: Installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes. WARNING!!! Frame grounded by a 4-conductor cable assembly. See manufacturer s instructions A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances. The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below. If the use of a GFI is required, it should be: Of the receptacle type (breaker type or portable type NOT recommended) Used with permanent wiring only (temporary or portable wiring NOT recommended) On a dedicated circuit (no other receptacles, switches or loads in the circuit) Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended) Rated for Class A (5 ma +/- 1 ma trip current) as per UL 943 standard In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations) Protected from moisture (water, steam, high humidity) as much as reasonably possible To prevent possible damage to cabinets and cabinet finishes, use only materials and finishes that will not discolor or delaminate and will withstand temperatures up to 194 F (90 C). Heat resistant adhesive must be used if the product is to be installed in laminated cabinetry. Check with your builder or cabinet supplier to make sure that the materials meet these requirements. GENERAL INFORMATION 1. WARNING: The use of cabinets for storage above the appliance may result in potential fire or burn hazard. 2. WARNING: This appliance shall not be used for space heating. This information is based on safety considerations. 3. All openings in the wall behind the appliance in the floor under the appliance shall be sealed. 4. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors. 5. Disconnect the electric supply to the appliance before servicing. 6. When removing oven for service and/or cleaning A. Disconnect AC power supply. B. Carefully remove the oven by pulling outward. CAUTION: Oven is heavy, use care in handling. 7. Electrical requirements: Listed in Specifications Chart on page 3 under Electrical Requirements. 8. The misuse of the oven doors (e.g. stepping, sitting, or leaning on them) can result in possible hazards and/or injuries. 9. If installing a warming drawer beneath the oven or a microwave above the oven, then it is necessary to have a minimum of 2 spacing between the oven and the adjacent product for ventilation purposes. WARNING!!! ELECTRICAL GROUNDING INSTRUCTIONS This oven must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition. Avoid any damage to oven vents. The vents need to be unobstructed and open to provide proper airflow for optimal oven performance. The cooling fan should be operating when the unit is in operation. If you notice the cooling fan is not operating or you observe unusual or excessive noise coming from the cooling fan, contact a Viking Authorized Service Center before continuing operation. Failure to do so can result in damage to the oven or surrounding cabinets. 2 3

SPECIFICATIONS-ELECTRIC SINGLE OVEN DESCRIPTION VESO166 Overall Width 35 1/4 (89.5 cm) Overall Height 28 3/4 (73.0 cm) Overall Depth To edge of door - 25 (63.5 cm) To end of handle bracket - 27 1/4 (68.9 cm) With door open - Cutout Width 34 (86.4 cm) Cutout Height 28 3/8 (72.1 cm) Cutout Depth 24 (61.0 cm) Electrical 4-wire with ground, 240-208/120 VAC/60 Hz, 30 amp electrical connection. Requirements Unit is equipped with No.10 ground wire in conduit. Should be fused separately. Oven Interior Width 29 (73.7 cm) Oven Interior Height 16 1/8 (41.0 cm) Oven Interior Depth 15 3/8 (39.1 cm) Oven Interior Overall Size 4.2 cu. ft. Three racks / Six positions Approximate Shipping 330 lbs. (148.6 kg) Weight SPECIFICATIONS - ELECTRIC DOUBLE OVEN DESCRIPTION VEDO266 Overall Width 35 1/4 (89.5 cm) Overall Height 51-1/8 (129.3 cm) Overall Depth To edge of door - 25 (63.5 cm) To end of handle bracket - 27 1/4 (68.9 cm) With door open - Cutout Width 34 (86.4 cm) Cutout Height 50 7/8 (129.2 cm) Cutout Depth 24 (61.0 cm) Electrical Unit is equipped with No.10 ground wire in conduit. Should be fused separately Requirements 4-wire with ground, 240-208/120 VAC/60 Hz 50 amp connection Oven Interior Width 29 (73.7 cm) Oven Interior Height 16 1/8 (41.0 cm) Oven Interior Depth 15 3/8 (39.1 cm) Oven Interior Overall Size 4.2 cu. ft. Three racks / Six positions Approximate Shipping 575 lbs. (258.8 kg) Weight 4 5

SINGLE OVEN CUTOUT DIMENSIONS SINGLE OVEN DIMENSIONS IN WALL CABINET FRONT 35 1/4 (89.5 cm) 24 (61.0 cm) 34 (86.4 cm) 28-3/8 (72.1 cm) Junction Box Location 28-3/4 (73.0 cm) REAR 33 3/4 (85.7 cm) 5 Min. (12.7 cm) 17 (43.2 cm) 4 (10.2 cm) Rating/Identification Label located behind door 28-1/4 (71.8 cm) UNDERCOUNTER 24 (61.0 cm) Junction Box Location 27-1/4 (68.9 cm) 25 (63.5 cm) 23 5/8 (60.0 cm) 34 (86.4 cm) 28-3/8 (72.1 cm) 4 (10.2 cm) SIDE 5 Min. (12.7 cm) 4-3/4 Min. (12.1 cm) 18 (45.7 cm) 6 7

DOUBLE OVEN CUTOUT DIMENSIONS DOUBLE OVEN DIMENSIONS FRONT 35 1/4 (89.5 cm) REAR 33 3/4 (85.7 cm) 51-1/8 (129.3 cm) 50-3/4 (128.9 cm) 24 (61.0 cm) 50-7/8 (129.2 cm) 34 (86.4 cm) Junction Box Location 5 Min. (12.7 cm) Rating/Identification Label located behind door 27-1/4 (68.9 cm) 25 (63.5 cm) 23 5/8 (60.0 cm) 4 Min. (10.2 cm) SIDE 15-1/4 (38.7 cm) Min. to Floor 18 (45.7 cm) 8 9

DOOR REMOVAL / ADJUSTMENT Ocassionally, it may be necessary to remove or adjust the doors. This should only be done by a qualified techinican. To remove the door, remove the screws from the top and bottom of the hinge trim. Open the door to the full open position. Place a pin in the pinhole on the hinge. Close the door just until it reaches the pin in the hinge. Remove the hinge trim. Lift up and out on the door until the door comes out of the door socket. Reverse the procedure to replace the door. To adjust the door up or down, turn the adjustment screw. To move the door upward, turn the adjustment screw clockwise. To move the door downward, turn the adjustment screw counterclockwise. PERFORMANCE CHECKLIST A qualified installer should carry out the following checks: 1. Check oven bake function - bake element on full power, center and outside broil elements at partial power. Convection bake function - bake and broil element is the same with the convection fan on. 2. Check TruConvec TM function - TruConvec TM element (behind convection fan cover) on and convection fan on. 3. Check mini-broil function - center broil element on. 4. Check maxi-broil function - center and outside broil elements on; convection broil function is the same as maxibroil with the convection fan on. 5. Check self-clean function - Door will lock and in approximately 30 seconds, the center and outside broil elements will turn on and the bake element will turn on at partial power. Check broil elements through window to make sure they are on, then abort self-clean cycle to unlock door. CAUTION: Do not run self-clean cycle check for more than 10 minutes with oven racks and rack supports inside oven. This could cause them to discolor due to the high temperature required for self-cleaning. Any adjustments necessary that are a result of the installer not following instructions will be the responsibility of the installer, dealer or the end user of the product. ELECTRICAL REQUIREMENTS Check your local codes regarding this unit. The single built-in oven requires a 4-wire with ground, 240-208/120 VAC/60 Hz, 30 amp electrical connection. The double 27 W. and 30 W. built-in ovens require a 4-wire with ground, 240-208/120 VAC/60 Hz, 40 amp electrical connection. The double 36 W. built-in oven requires a 4-wire with ground, 240-208/120 VAC/60 Hz, 50 amp electrical connection. This unit is equipped with a No. 10 ground wire in the conduit. See next section for grounding instructions. It should be fused separately. CAUTION: Be sure the electric power is off from the breaker box to the junction box until the oven is installed and ready to operate. The junction box should be located as shown in the drawing and connected to suitable ground. Refer to the specification chart for watt rating and recommended amps. House wiring and fusing must comply with local codes. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70- latest edition. ELECTRICAL CONNECTION With the oven positioned in front of the cabinet opening, connect the wire leads extending from the conduit to the junction box, making sure the neutral (white) wire is connected to the appropriate terminal. Check your local code to see which of the options below should be used in grounding the unit. FINAL PREPARATION 1. Some stainless steel parts may have a plastic protective wrap which must be peeled off. All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner designed for this material. If build-up occurs, do not use steel wool, abrasive cloths, cleaners, or powders!! If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel! Scratches are almost impossible to remove. 2. The interior of the oven should be washed thoroughly with hot, soapy water to remove film residues and any installation dust or debris before being used for food preparation, then rinsed and wiped dry. Solutions stronger than soap and water are rarely needed. REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the range. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician. OPTION 1: OPTION 2: OPTION 3: Connect the neutral (white) wire and the grounding (green) wire with the incoming neutral (white) power supply line. If the junction box is grounded, untwist the grounding (green) wire and attach to the junction box. Attach the neutral (white) wire to the neutral (white) power supply line. Untwist the grounding (green) wire and attach it to a suitable ground. Attach neutral (white) wire to the incoming neutral (white) power supply line. DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE. SUCH USE MAY RESULT IN A FIRE, ELECTRICAL SHOCK OR OTHER PERSONAL INJURY. CHECK WIRING Connect the electric power at the breaker box and check for proper operation of all functions. 10 11

SPECIFICATIONS-ELECTRIC SINGLE OVEN - LVESO MODELS DESCRIPTION LVESO177C LVESO107C LVESO165C Overall Width 26 1/2 (67.3 cm) 29 1/2 (75.0 cm) 35 1/4 (89.5 cm) Overall Height 28 3/4 (73.0 cm) Overall Depth To edge of door - 25 (63.5 cm) To end of handle bracket - 27 1/4 (68.9 cm) With door open - Cutout Width 25 (63.5 cm) 28 (71.1 cm) 34 (86.4 cm) Cutout Height 28 3/8 (72.1 cm) Cutout Depth 24 (61.0 cm) Electrical 4-wire with ground, 240-208/120 VAC/60 Hz, 40 amp electrical connection. Requirements Unit is equipped with No.10 ground wire in conduit. Should be fused separately. Oven Interior Width 20 (50.8 cm) 23 (58.4 cm) 29 (73.7 cm) Oven Interior Height 16 1/8 (41.0 cm) Oven Interior Depth 15 3/8 (39.1 cm) Oven Interior Overall Size 2.8 cu. ft. 3.3 cu. ft. 4.2 cu. ft. Three racks / Six positions Approximate Shipping 237 lbs. (106.7 kg) 261 lbs. (117.5 kg) 330 lbs. (148.6 kg) Weight SPECIFICATIONS - ELECTRIC DOUBLE OVEN DESCRIPTION LVEDO277C LVEDO207C LVEDO265C Overall Width 26 1/2 (67.3 cm) 29 1/2 (75.0 cm) 35 1/4 (89.5 cm) Overall Height 51-1/8 (129.3 cm) Overall Depth To edge of door - 25 (63.5 cm) To end of handle bracket - 27 1/4 (68.9 cm) With door open - Cutout Width 25 (63.5 cm) 28 (71.1 cm) 34 (86.4 cm) Cutout Height 50 7/8 (129.2 cm) Cutout Depth 24 (61.0 cm) Electrical Unit is equipped with No.10 ground wire in conduit. Should be fused separately Requirements 4-wire with ground, 240-208/120 VAC/60 Hz, 50 amp connection Oven Interior Width 20 (50.8 cm) 23 (58.4 cm) 29 (73.7 cm) Oven Interior Height 16 1/8 (41.0 cm) Oven Interior Depth 15 3/8 (39.1 cm) Oven Interior Overall Size 2.8 cu ft, 3.3 cu. ft. 4.2 cu. ft. Three racks / Six positions Approximate Shipping 360 lbs. (162.0 kg) 402 lbs. (180.9 kg) 575 lbs. (258.8 kg) Weight 12 13

14 15