Eclipse Technical Training CME686 CME810 CP686 CP886 CP1086

Similar documents
Prodigy Eclipse Cuber Technical Training

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:

SCE275: CM 3 Under-the-counter. Technical Training

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030

Eclipse Introduction:

Scotsman Technical Training. CU50 Cube Ice Machine

Prodigy Eclipse EH130 System

CME256, 506, 656, 806: AutoIQ Cubers

CME456R. Introduction

CME1056R. Introduction

Prodigy Plus - D Series Cuber Technical Review

Prodigy and Prodigy Plus Flaked and Nugget Modular Ice Machines. and Prior

CME865R & CME1002R INTRODUCTION. Table of Contents

CM 3 Control System Update. Prodigy Cuber. Technical Review

UF424 and UN324. Technical Service

Includes Prodigy Plus D Models

C0322 and C0522 Service Parts

CME1056 Service Parts. Table of Contents

September 2006 Page 1

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

CME306 & CME456 INTRODUCTION

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units

CMS1002R INTRODUCTION TABLE OF CONTENTS. Parts lists and wiring diagrams are in the center of this manual, printed on yellow paper.

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

CMS1402 SERVICE PARTS

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

CME650 SERVICE PARTS

Spare Parts Catalogue MV1006

SCN60 Residential Nugget Ice Machine

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units

CME865W & CME1002W INTRODUCTION. Table of Contents. Parts lists and wiring diagrams are in the center of the manual, printed on yellow paper.

Hoshizaki America, Inc.

MCM1462R INTRODUCTION. Table of Contents

NO. F ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AA KMD-201AWA MODEL SERVICE MANUAL

Service Manual for Cuber Model CS0415

SCE170 SERVICE PARTS

CU1526, CU2026, CU3030 Service Parts

Installation and User's Manual for Remote Condenser Modular Cuber D Series Model C2648R

CME1202 & CME1402 INTRODUCTION. Table of Contents. This manual was printed on recycled paper.

CME1856W Service Parts

Installation and User s Manual for Remote Condenser Modular Cuber Prodigy Plus D Series Models C1448R, C1848R, C2148R

Hoshizaki America, Inc.

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

CME1856W Service Parts

SCCG30 & SCCP30 Service Manual Introduction:

SLC400. Introduction. Table of Contents

KM-630MAF KM-630MWF KM-630MRF

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

KM-900MAF KM-900MWF KM-900MRF KM-900MRF3

KM-61BAH KM-101BAH KM-151BAH

SCCG50 & SCCP50 Service Manual Introduction:

HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-280MAH KM-280MWH SERVICE MANUAL

SCCG50 & SCCP50 Service Manual Introduction:

Installation and User s Manual for Remote Condenser Modular Cuber Prodigy Plus E Series Models C0530, C0630, C0830 and C1030

Ice Maker - Dispensers. Technical Training

MCM1462 INTRODUCTION. Table of Contents

NUMBER: ISSUED: JULY 13, /336 73/23 STACKABLE CRESCENT CUBER KM-1300SWH-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI

Hoshizaki America, Inc.

Hoshizaki America, Inc.

Hoshizaki America, Inc.

Hoshizaki America, Inc.

Peachtree City is home office for America located about 30 miles south of the Atlanta airport this is were all KM cubers as well as Flakers are built.

Hoshizaki America, Inc.

FLAKER/DCM SEQUENCE OF OPERATION

Hoshizaki America, Inc.

Automatic Ice maker. Service manual MIM250

HD150. Introduction. Table of Contents

KM-1600MRF KM-1600MRF3

Condensing Unit Installation and Operating Instructions

Prodigy Flaked and Nugget Ice Machines Technical Review

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI 89/336 73/23 SELF-CONTAINED CRESCENT CUBER KM-150BAF-E KM-150BWF-E

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Hoshizaki America, Inc.

Service Manual FGIM 515 FPIM 515

Installation and User Manual for Model UF424 and UN324

Welcome to the Ice-O-Matic on-line training modules. Ice. Pure and Simple

KM-900MAH KM-900MWH KM-900MRH KM-900MRH3

Hoshizaki America, Inc.

SERVICE PARTS MANUAL MODEL-ICE1806 and ICE1807 Version 3 MODEL-ICE2106 and ICE2107 Version 3

I Series IRC 2448 IWC 2448 Ice Cube Machine

MODULAR CRESCENT CUBER

Hoshizaki America, Inc.

Sporlan Valve Division Parker Hannifan/CIC Group

Hoshizaki America, Inc.

KML-600MAH KML-600MWH KML-600MRH

Installation and User's Manual for Cuber Model CU0515

Hoshizaki America, Inc.

Hoshizaki America, Inc.

KML F SERIES KML H SERIES

NO. 15FD-742 ISSUED: AUG. 10, 2007 REVISED: SEP. 30, 2013 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-30A KM-35A KM-50A KM-75A MODEL SERVICE MANUAL

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Hoshizaki America, Inc.

Hoshizaki America, Inc.

NO. F ISSUED: JUN. 18, 2008 REVISED: JUN. 17, 2011 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-100A KM-125A MODEL SERVICE MANUAL

DCE33 INTRODUCTION. Table of Contents. Parts lists and wiring diagrams are located in the center of the manual.

SERVICE PARTS MANUAL MODEL-ICE1405, ICE1406 and ICE1407 Version 3 Includes 50Hz.and 3 phase Units

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Service Manual. Modular Crescent Cuber Models KM-901MAJ, MWJ, MRJ/3 KM-1100MAJ, MWJ, MRJ KM-1340MAJ, MWJ, MRJ/3 KM-1601MRJ/3. hoshizakiamerica.

Service Parts for models UF424 and UN324

Transcription:

Eclipse Technical Training CME686 CME810 CP686 CP886 CP1086

In This Presentation What Eclipse is Components and their functions Installation Operation Maintenance Service Diagnosis

The Eclipse System The remote system is made up of three parts: Ice Making Section or Head Unit - 115 volt Compressor Package - 208-230 volt Condenser - 208-230 volt Flexible Modular System One condenser fits two compressor packages One ice making head fits two compressor packages All are R-404A systems

Ice Making Section CME686 or CME810 Remote Low Side 22 wide by 16.5 deep Three evaporators Three TXVs Three check valves CM 3 technology Water and Control Systems Rotomolded freezing compartment 16.5 22

Ice Making Section Refrigerant Line Connections Vapor Liquid Suction All on right side Designed for Drive-Up Window Applications Vapor Liquid Suction

Ice Making Section Ice making compartment Three evaporators Circuited in parallel No braze joints in freezing compartment Access from the left side or top

Vapor Inlet Valve Purpose: Opens during harvest to allow vapor to enter the evaporators 24 volt coil Different port size between CME686 and CME810

Three TXVs Three internally equalized valves Purpose: Control individual evaporator superheats One valve per plate Promotes even plate-to-plate ice distribution

Three Check Valves Check valves keep each TXV s refrigeration flow directed to a single evaporator Eliminates crossflow during freeze cycle Each TXV outlet must flow to one evaporator

Water Pump 115 volt pump Same for both CME686 and CME810 Pedestal type Pump motor separated from reservoir Keeps motor drier Motor cap keeps condensation off motor

Controller AutoIQplus Uses sensors for ice harvest, bin full indications water reservoir temperature water level Controls freeze and harvest cycles

CME Electrical Box Transformer 115 to 24, 85 VA Purge valve timer Control wire connection nearby Wire routes to compressor package Controls contactor and solenoid valves Control Wire Connection

Inspection Cover Provides access when left and right side access is limited Access to: cascading shield water trough ice sensors Also covers cascading shield fastener

Cascading Shield Removal begins with removal of the inspection cover Then remove the one retaining screw Cascading Shield

Cascading Shield

Evaporator Covers

Freezing Compartment Water Trough Cascading Shield

Temperature Sensors Liquid Line Water Temp Sensor

Inlet Water Valve Located in right front corner of unit 1.25 GPM valve Same one as on CME256, CME506 and many others Opens to add water and fill reservoir Adds water during harvest Fills at beginning of freeze Refills once more during freeze

Purge Valve Located in the front of the unit 115 volt coil Opens to drain the reservoir during harvest Controlled by purge valve timer

Ice Sensors Sensing position 3 below base Control position designed for dispenser applications Also works well on bins Maximizes fill without overfilling 3

Compressor Package Three models CP686 CP886 CP1086

CP Unit Condenser Bypass Valve Low Side Access Valve Headmaster CPR Valve Receiver High Pressure Cut Out - Auto Reset

Crankcase Pressure Regulator CPR valve restricts compressor dome pressure during harvest 55 to 60 PSIG Pre-set - don t adjust it! Low Side Access valve has evaporator pressure during freeze, but not during harvest

Condenser Bypass Valve Normally Closed, opens during harvest Bypasses condenser coil and directs discharge gas to vapor line Ported valve - same one as CME2006

Headmaster Maintains discharge pressure during freeze Active at any temp below 70 o F. Rated at 217 PSIG, freeze cycle pressure may be between 220 and 230 during cold ambient operation

Liquid Inlet Valve Normally Open, closes during harvest Controls liquid flow into receiver Isolates refrigerant in condenser during harvest Improves cycle time

Receiver Shipped with system charge Three ports Liquid inlet Liquid outlet Vapor outlet Liquid Inlet Liqui d Out Vapor Out

Electrical Box Toggle switch controls condensing unit Control Wire connection from Ice Making Section to control the system Electrical power connected at contactor Remote condenser fan connects at contactor Toggle Switch Control Wire Connection

Condensers Three models - ONLY for Eclipse ERC680 - used with CP686 and CP886 ERC1086 - only used with CP1086 and a two circuit model, ERC6810 can be used with any CP unit No headmaster in condenser Headmaster is in CP unit Swivel nut connections for CP unit Don t connect these condensers to a regular remote!

System Installation Three systems, single and three phase for each 600 800 1000 Must match components to create system

System Installation 600 - CME686, CP686, ERC680 800 - CME810, CP886, ERC680 1000 - CME810, CP1086, ERC1086 CP units may also be connected to approved central condenser coil using tubing kit RTE10 Coil must NOT have headmaster

Equipment Location CME can be above or below condensing unit If above, limit is 15 feet Pre-charged lines are used 3 tubes per set 20, 50 and 75 foot only No extra refrigerant charge required S trap required when condensing unit is over 20 above ice making head Must have bin or dispenser adapter for the CME

Other Configurations Approved Central Condenser Two Circuit Condenser - ER2C6810, use with 600, 800, 1000 or a mix of any two

Condensing Unit Modular system - connect CP to ERC Assemble on roof or ground ERC has back legs and two braces Assemble legs and braces to condenser Connect wires to junction box Place ERC on back of CP - lip on CP holds ERC up

Condensing Unit Fasten CP to ERC Connect liquid and discharge line connections Route wire to CP control box and connect to contactor

Line Set Three tubes Reversible CME routing determines which end goes to CME Out the top - use double-bend ends at CME Out the back - use single 90 degree ends at CME Ends for out the CME top Ends for out the CME back

Line Set Installation Route lines in two groups Liquid and Vapor Suction separately for ease of routing 3/4 tube requires careful handling Check for holding charge before installation Route control wire with line set Only shorten if necessary Do before connections are made! Purge with nitrogen while brazing Schraders at both ends for purging Evacuate to 300 microns or less Add holding charge if connecting later

Two Circuit Condenser Installs Mark Lines, Wires and CP Units Example: Mark one unit A Mark line set A and control wire A Unit A s pre-charged lines route to Unit A Unit A s control wire connects to Unit A Confirm before connecting Start one unit at a time to confirm proper operation and control wire routing

Install CME Flush against wall capability Drains left, right or back Water inlet and power inlet from the top or back Refrigerant line connections back or top 115 volt unit, cord provided Water Inlet Fitting Drain Fitting

Flush Installations Attach water inlet Attach drain - 3/4 Unit ships with left drain hose installed, Right drain hose in plastic bag No vent required, vent is internal Secure drain with tape for ease of mounting Internal Vent

Place on Adapter Many different adapters Use gasket tape at mounting area Sealing area 22 wide x 15 deep Remove all panels Place unit Connect control wire Space for Drain at Back 15 Top View

Connect Pre-Charged Lines Add foam tape/cork tape to suction line nut Secure unit at sides or back with provided strap-clips

Condensing Unit Connect precharged lines Use refrigerant oil Use two wrenches to prevent quickconnect diaphragm damage from rotating tube Connect control wire Connect power, check voltage

Initial Start Up Check installation Power Water Drain Tube Routing No soak out needed Plug in CME unit Check EEPROM code Push Freeze to start

Start Up CME unit Opens & closes Purge Valve Fills with water Switches on Pump Switches on Condensing Unit Compressor and fan begin to operate Adjustments Purge is adjustable

Operation - Control System CM 3 control system Water level sensor for Reservoir water fill Freeze cycle termination Ice sensors to sense Ice harvest Bin full Controller determines cycles and operates components Uses water level to determine freeze cycle length Uses length of time for ice to fall to determine next harvest Uses ice sensor signal blockage to determine bin full

Control Details Water level sensor Two photo-electric eyes in housing Top eye blocked tells controller water level is low Bottom eye blocked tells controller water reservoir is full

Control Details Ice sensors - photoeyes Located at bottom of ice drop zone One side is an emitter, the other a detector Creates a light curtain that can sense groups of cubes falling during harvest

Operation - Freeze Similar to conventional remote ice cubers Condensing unit forces liquid refrigerant to the ice making section Each TXV meters refrigerant to its own evaporator At a pre-determined water temperature, the pump stops for 30 seconds As ice forms on the evaporators, the water level drops About half way through the cycle the water reservoir re-fills The next time the water level drops to the point where the top of the slot in the float stick blocks the eyes, the system goes into the harvest cycle

Operation - Harvest Eclipse features Cold Temperature Harvest Condensing Unit may be located outside Temperature Range between -20 and 120 F. Receiver is with the condensing unit Vapor line connects discharge gas and receiver vapor to vapor inlet line in ice making section High vapor flow rates achieved with no compressor impact due to use of CPR valve Vapor contains latent heat - even at sub-zero temperatures Condensing vapor in the evaporators transfers the heat Evaporators warm up and ice is released

Operation - Harvest Details Vapor inlet valve opens Condenser bypass valve opens Receiver inlet valve closes Purge valve opens Pump stops for a time then restarts to purge the reservoir of water Purge valve closes after 40 seconds Inlet water valve opens for a few seconds to add water to the reservoir for harvest assist Harvest continues until the controller stops it

Operation - Harvest Control Controller begins timing harvest Ice falling interrupts the signal from the ice sensor emitter to the receiver The time of that interrupt is recorded by the controller The last time the controller receives an interrupt signal is saved as the cube release time Extra time is calculated from the actual cube release time Measured Cube Release Time + Calculated Extra Time = Harvest Time

Operation Freeze Cycle Time: 1000 - between 12 and 19 minutes 800 - between 14 and 22 minutes 600 - between 16 and 25 minutes 600 s cycle is longer in very high ambient Harvest Cycle Time 1000 - between 1 and 3 minutes 800 - between 1 and 3 minutes 600 - between 2 and 3 minutes Extreme low temperatures - harvest lengthens up to 6 minutes

Refrigeration Schematic Condenser Compressor Package Ice Making Section

Condensing Unit Condenser Bypass Valve Headmaster Compressor CPR Rec. Liquid Inlet Valve (N.O.)

Ice Making Section Suction Vapor Liquid Vapor Inlet Valve Check Valves TXVs Evaporato rs

System Pressures Freeze Cycle Rapid Pull Down to between 80 and 60 PSIG Gradual Pull Down to 28-30 PSIG just before Harvest Pressures at CP unit or CME will be the same during Freeze

System Pressures Harvest Cycle At the ice making section, low side pressure rapidly increases to 90-120 PSIG At the CP unit compressor access valve, dome pressure is limited by the CPR valve to 55-60 PSIG during harvest

System Pressures CP Unit Discharge during low ambient freeze will be about 225 PSIG Headmaster rated for 217, there is some variation unit to unit Discharge during harvest will be about 100 PSIG High Pressure Cut Out opens at 450, closes at 350 PSIG

Maintenance De-lime with Scotsman Ice Machine Cleaner Push & release clean button Pour in 24 ounces of IM cleaner through handy fill-plug in sump cover Clean for 10 minutes, then push and release clean button, wait 20 minutes and shut unit off Check distributors for scale build up

Maintenance Top Cover Lifts Up Notch in Wall for Front Access

Service Diagnosis What happens if? Vapor Inlet Valve Does Not Open Vapor line hot Discharge pressure increases Low side pressure does not change No ice release - large slabs of ice 2 blink refrigeration light

Service Diagnosis What happens if? Control wire becomes unplugged CP unit does not operate Exceeds maximum freeze time Controller shows continuous refrigeration diagnostic light

Service Diagnosis What happens if? Condenser by pass valve does not open High pressure cut out opens Note: High discharge pressure during harvest will not be present at liquid connection Ice may release, but slowly

Service Diagnosis What happens if? Receiver inlet valve does not close during harvest Very little change If it sticks closed Hi discharge pressure cut out opens Controller shows continuous diagnostic light

Service Diagnosis What happens if? Headmaster is stuck in bypass Very little liquid flow to TXVs Long freeze cycle Controller shows continuous refrigeration diagnostic light

Service Diagnosis What happens if? There is a refrigerant leak No change until refrigerant level drops below the operational threshold for the ambient Headmaster will try to maintain minimum discharge pressure - but will be hissing as gas flows through Ice formation will be poor Low capacity/long freeze cycle will result Add charge to confirm, if ice making resumes with normal discharge pressure there is a leak

Service Diagnosis What happens if? There is no water to the ice making section Water is part of the recipe for ice! Controller will stop unit operation but retry filling every 20 minutes until water is restored

Service Diagnosis What happens if? The purge valve leaks through May result in small cubes Short freeze cycle May have long harvest cycle

Service Diagnosis What happens if? The inlet water valve leaks through Keeps adding water (heat load) to reservoir Result is a long freeze cycle

Service Diagnosis What happens if? The condenser fan stops CP unit s hi pressure cut out will open Maximum freeze time will be exceeded CME unit will shut system off Controller will display continuous refrigeration diagnostic light

Service Diagnosis What happens if? Both the solenoid valves in the condensing unit do not work Very, very unlikely, but The discharge pressure during harvest will be about 150 PSIG The low side pressure during harvest will be less than 90 PSIG The ice will harvest slowly The refrigerant flowing out of the receiver will make a whistling noise

Service Diagnosis What happens if? The CPR valve fails Pressure during harvest will not be at the pre-set point 55 to 60 PSIG Will not hold an adjustment No external symptom CPR setting should be checked if compressor is replaced

Service Diagnosis What happened if? The controller is showing a one blink refrigeration diagnostic light This indicates that the ice harvest was very slow and the controller timed-out on maximum harvest time Ice was sensed by the control system Likely causes include Beginning to freeze up

Service Diagnosis What happened if? The controller is showing a two blink refrigeration diagnostic light This indicates that the ice harvest was very slow and the controller timed-out on maximum harvest time Ice was NOT sensed by the control system Likely causes include Freeze up Vapor inlet valve did not open Ice sensor can t see ice well

Service Diagnosis What happened if? The controller is showing a continuous refrigeration diagnostic light Maximum freeze time exceeded Dirty condenser coil Fan motor inoperative

Service Diagnosis What happened if? The controller is showing a two blink water diagnostic light Slow or no water fill Possible clogged water filters Low water level - leaks out Water level sensor not working or harness connection poor

Service Diagnosis What happened if? The controller is showing both diagnostic lights on continuously This indicates that the temperature sensors are not working or not plugged in. They need to be plugged back in or replaced. The ice machine will operate without the thermistors working, but it is limited in its diagnostics that way

Summary Eclipse is a three part ice making system There are two ice making heads Using CM 3 Technology There are three compressor packages There are two single circuit condensers There is one two circuit condenser R-404A refrigerant