CCD and CID solid-state detectors

Similar documents
Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

LECTURE 11. Dr. Teresa D. Golden University of North Texas Department of Chemistry

The Art and Science of Being Cool

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

A Platform for the Future ULTIMA 2 ICP OPTICAL E MISSION S PECTROMETER

Understanding total measurement uncertainty in power meters and detectors

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

An FT-NIR Primer. NR800-A-006

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

RAMAN SPECTROSCOPY See more, faster than ever before

Corporate Overview. April

WHAT IS LASER ULTRASONIC TESTING?

Monitoring Flammable Vapors and Gases in Industrial Processes

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Variable Temperature Microprobe Systems

Instrumental technique (MCP detectors) - Kamalesh ( )

Specifications Wavelength Range: 190 nm to 800 nm continuous

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

2018 New Infrared Technologies, S.L.

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Fast. Precise. Versatile. UL Lighting Sciences

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Portable Survey Instruments NISP-RP-01

HTRF. SpectraMax Paradigm Cisbio HTRF Detection Cartridge. User Guide

FI-DL. SpectraMax Paradigm Fluorescence Intensity Dual Label (FI-DL) (MultiTox-Fluor) Detection Cartridge. User Guide

A GEM-based detector for detection and imaging sparks and flames G. Volpe 1 and V. Peskov 2. Abstract

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

Industrial presentation. Philippe Marchais - July 3rd, NDIP Tours

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Pyroelectric Infrared Sensor PIR

Lecture 8 OPENINGS &ORGANIZATION OF FORM AND SPACE

Developing UV LED Curing Processes for Converting Applications

PG 990 Atomic Absorption

Customized MCPs for Analytical Instruments. An MCP for every application

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SLAG DETECTION SYSTEM CONTINUOUS THERMAL MONITORING

CALIBRATION HOW IT WORKS

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Defense Technical Information Center Compilation Part Notice

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

Spectrum Detector, Inc.

NEW Restek Electronic Leak Detector

APN0064.P65 Issue 01-06/2000 COMPARISON OF OPTICAL DETECTION SYSTEMS FOR INFRARED HYDROCARBON GAS DETECTION

Flame Detection Jon Sarfas

Recent Improvements in Process GC Instrumentation

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Features and Benefits

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

CALIBRATION HOW IT WORKS

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

CCTV, HOW DOES IT WORK?

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

SEC Millenium Carbon Dioxide Gas Detector

Optical Measurement Techniques for LED Clusters and LED Safety

Let There Be Light. Grade Level/Range: 4-8

FPD - Flame Photometric Detector

Diamond Windows & MCP Detectors for Synchrotron Applications

Nanotechnology-Based Gas Sensors

AAnalyst 700 Atomic Absorption Spectrometer

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

PUV, PIR and PFO Series BROCHURE

Technical Information OUSAF44

UV-Ozone Technology and Applications

SILICON V-GROOVE ALIGNMENT BENCH FOR OPTICAL COMPONENT ASSEMBLY

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

The SLAC Detector R&D Program

Providing State-of-the-Art Fine Particulate Control Through Advanced High Energy Ionization

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Temperature dependent Components within the Pyroelectric Detector

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Fire Detection System: An Overview

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

ADVANCED SILICON DETECTORS FOR ELECTRON IMAGING & COUNTING

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

Analyze IT. Process Gas Chromatograph. PGC2000 Series

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

detectors UltiMate 3000 Variable Wavelength Detectors

OptoYag M. clear vision

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

clear & preserve vision OptoYag&SLT

UV LED Curing: The Time is Now

1.1. SYSTEM MODELING

CALIBRATION HOW IT WORKS

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

Transcription:

CCD and CID solid-state detectors Technical Overview 5110 ICP-OES Introduction Many of today s ICP-OES instruments have progressed from traditional photomultiplier tube (PMT) detection systems to solid-state charge transfer devices including the charge-coupled device (CCD) and charge injection device (CID). The role of the detector has not changed in that it converts light energy (photons) from analyte emissions generated in the plasma into an electrical signal that can be quantified. These type of solid-state detectors provide many advantages over PMT detectors, including: Greater choice of analyte wavelengths compared to PMT-based simultaneous ICP-OES, for increased flexibility Simultaneous measurement, providing much faster analysis times compared to sequential scanning ICP-OES Smaller, more analytically stable echelle optic design that complements the two-dimensional layout of the detector

Prior to the mid-1990s, PMT-based simultaneous ICP-OES provided significant gains in sample throughput over sequential systems, but were less flexible in adapting to a laboratory s changing requirements. Wavelength selection was limited and often foreknowledge of analyte wavelengths was required before purchase. Often, additional PMT detectors were necessary to access additional analyte wavelengths. Solid-state detection systems such as CCDs and CIDs overcame many of the deficiencies inherent in PMT-based simultaneous systems. These modern ICPs provided the productivity gains demanded by laboratories, with additional advantages of lower cost of ownership, greater flexibility and more powerful hardware and software features. When early CCD detectors were developed for ICP-OES, the costs of CCD technology, and associated development costs, were high. In these early days, there were also technical limitations in the way CCD s were controlled and in particular the circuitry used for readout was, by today s standards, quite slow and cumbersome. For these reasons, some of the early CCD detectors for ICP-OES were Segmented CCD s, otherwise known as SCD s. Due to the developments costs associated with new CCD design, some of these SCD s are still used in ICP-OES systems today. Limitations in the SCD design means these detectors only cover a select portion of the wavelength range only select segments. The slow readout circuitry results in additional time overheads when more wavelengths are selected, or when wavelengths of varying intensity are measured on a single sample. This results in measurement times that are different for different samples, even using the same method. Following the introduction of the first CCD and CID detectors for use in ICP-OES, there has been much debate over the advantages of each device. CCDs are renowned for their high sensitivity and low noise characteristics, providing low detection limits and superior signal-to-noise ratio performance. Conversely, CIDs are perceived to offer greater detector control including non-destructive readout (NDRO) whereby the accumulated signal is removed from the exposed pixel, measured and then returned to the pixel for further collection. NDRO provides an alternative means of improving the signal-to-noise ratio performance given that CIDs typically exhibit poorer noise performance in comparison. Detector cooling Charge transfer device detectors are often, but not always, cooled to sub-zero temperatures. This is usually done via a Peltier cooling device. CCDs and CIDs are semiconductor devices and will exhibit background signal noise, called dark current, when the detector is not exposed to any light source. Cooling of the detector greatly improves detection limits by lowering the dark current. Not all simultaneous ICP-OES are able to offer detector cooling and it is often a limitation of non-echelle optical designs. One design used as many as 32 detectors to cover the necessary wavelength range, and the cost to cool each makes it an unviable option. As a consequence, detection limits are sacrificed. This is why echelle optical systems are often employed, as they complement the two-dimensional array of solid-state detectors, and typically only require a single detector to cover the necessary wavelength range. While it is possible to capture the entire wavelength range on a single array detector, many ICP-OES systems compromise by employing multiple CCD/SCD detectors or by using multiple entrance slits onto a single CID detector (requiring sequential readings), to capture the wavelength range of interest. The temperature to which CCDs and CIDs are cooled in modern ICPs ranges anywhere from 15 C to 70 C. As mentioned, detectors operating at higher temperatures will tend to exhibit higher dark current signal that negatively impacts detection limits. The relationship between dark current and temperature is non-linear and there will be a point where the benefit of lower detector temperature becomes negligible. The added cost of further cooling and the increased risk of condensation must also be considered. Excessively low temperatures beyond 45 C lower the dew point near the detector to dangerous levels, exposing the detector to the risk of condensation forming on its surface. This can be detrimental to the operation of the detector. 2

In this situation, a costly gas filtering system is required to remove moisture from the argon gas stream that passes over the detector. Alternatively, detectors can be hermetically-sealed in an inert gas, eliminating the need for a detector purge gas and associated gas filtering system. For CCD detectors used in ICP-OES, the addition of a fluorescent coating is not common. Instead, the transmission efficiency of low UV wavelengths is improved through better design that requires no ongoing maintenance cost. This includes: Thinning of the outer silicon dioxide layer via chemical means Addition of a doping agent to the silicon dioxide compound Back-illumination of the CCD to increase the active area of the detector by avoiding the on-chip circuitry Locating the controlling circuitry off-pixel CID characteristics Figure 1. Association between detector temperature and dark current performance of the Agilent VistaChip II CCD detector. Operating at 40 C (4.3 on the X-axis), the dark current performance is approximately 7 electrons per second per pixel (0.7 on Y-axis). In comparison, a CID is cooled to below 45 C to achieve a similar dark current. Low UV performance The lower wavelength range of an ICP-OES often extends into the low UV region, typically down to ~167 nm. The silicon dioxide layer used to insulate the detector s photosensitive pixels can absorb analyte emissions in the range 167 200 nm, reducing the sensitivity of important analyte wavelengths of aluminium, sulfur, phosphorus, arsenic and selenium. To improve quantum efficiency in the UV range, CIDs use a fluorescent surface coating. When the incoming low UV photon collides with the coating, a secondary photon of higher wavelength is emitted, allowing it to pass through the silicon dioxide layer. The fluorescent coating deteriorates over time and requires periodic replacement. Modern CIDs offer random access integration (RAI) and non-destructive readout (NDRO), allowing detector pixels to be interrogated at different speeds without destroying the accumulated electric charge (signal). RAI effectively allows automatic adjustment of the integration time with respect to the incoming signal intensity at an analyte wavelength (or region of interest). Upon interrogation, if sufficient signal above the background noise is collected, it is then processed for measurement. Otherwise, additional time is spent accumulating signal to improve the signal-to-noise ratio before processing. With pixel numbers greater than 260,000, only regions of interest (ROI) are typically interrogated. Otherwise, the time required to repeatedly integrate a large number pixels becomes too great, increasing analysis times and the risk of pixel saturation. This characteristic means that adding additional wavelengths to be measured also increases readout times, hence increasing sample to sample measurement times for methods with more wavelengths. 3

Agilent 5110 VistaChip II CCD While the pixel layout of most CCD and CID detectors used in ICP-OES consists of a large area pixel array, the Agilent 5110 ICP-OES utilizes a custom-designed and proprietary CCD detector (Figure 2). Known as the VistaChip II, it combines the superior noise and sensitivity performance of a CCD with the pixel control of a CID. The VistaChip II utilizes Image Mapping Technology (I-MAP), and requires only 70,000 light sensitive pixels located on 70 diagonal linear arrays (DLA) to cover the full wavelength range from 167 to 785 nm no pixel is wasted. Located in between each linear array are the VistaChip s high-speed controlling electronics, providing full pixel control and offering Adaptive Integration capability and Anti-Blooming protection on every pixel. Figure 2. Custom-designed and proprietary CCD detector. With unique I-MAP and AIT, speed and versatility is unmatched, and full wavelength coverage is provided from 167 785 nm. Agilent CCDs are hermetically-sealed in an atmosphere of inert gas, protecting them from moisture, hydrocarbons and particulates and requiring no additional gas purging, startup delay or maintenance. The VistaChip II is mounted on a triple-stage Peltier device for accurate cooling down to 40 C, 5 C lower than the previous VistaChip II application in the Agilent 700 Series ICP-OES, for the lowest dark current noise. Adaptive Integration Technology Adaptive Integration Technology (AIT) provides realtime interrogation of pixels allowing simultaneous integration of all analyte wavelengths, irrespective of the incoming signal intensity. The integration time is simultaneously adjusted for each wavelength to achieve the optimum signal-to-noise ratio. Due to the true simultaneous nature of the VistChip II and AIT, there is no time penalty when adding additional wavelengths to a method. Adaptive Integration is also perfect for speciation type applications including chromatography and laser ablation, allowing transient signals to be simultaneously collected for all elements. With 1 MHz pixel processing speed, the VistaChip II sets the benchmark in ICP-OES detector speed. Duplex circuitry enables pixels to be read from both sides of the detector (Figures 3a and 3b), ensuring a readout speed significantly faster than competitive systems. This extends the upper dynamic range of the detector compared to other CCDs and CIDs, reducing the likelihood of pixel saturation and signal over-ranging. Able to actively adapt using integration times ranging from 1 microsecond to 100 seconds, the VistaChip II provides a full 8 orders of dynamic range. In the unlikely situation that pixels saturate from an intensely strong signal, the VistaChip II offers antiblooming protection on every pixel, allowing weak signals to be measured in the presence of over-ranging signals. Anti-blooming Pixel blooming occurs when the charge of over-exposed or saturated pixels spill over into neighbouring pixels or circuitry, destroying the integrity of information collected in the region. Less advanced charge transfer device detectors are more susceptible to blooming. While some CCDs offer blooming protection between pixel segments, they do not necessarily protect individual pixels within a segment. Conversely, the Agilent VistaChip II CCD provides blooming protection on all pixels, whereby excess charge is directed into an anti-blooming drain. 4

Figure 3a. Zoomed image showing five linear arrays containing photosensitive pixels and associated readout circuitry on the Agilent VistaChip II CCD detector. Figure 4. Schematic of a single DLA on the VistaChip II CCD illustrating the potential barriers between pixels and the anti-blooming drain. Summary The Agilent VistaChip II, now in its 2nd generation, combines the superior analytical performance of a CCD with fast, Adaptive Integration performance and blooming protection often associated with CIDs, providing the best of both worlds. Hermetically-sealed, the VistaChip II requires no gas purging or startup delay. Figure 3b. Zooming even closer shows the control circuitry above each pixel that provides Adaptive Integration capability. The anti-blooming circuitry (drain) located below each pixel array is also visible. With the VistaChip II at its heart, the Agilent 5110 ICP-OES is able to measure the full wavelength range in a single exposure, without the need for multiple detectors or multiple slits. With a robust vertical torch on all configurations, including the Synchronous Vertical Dual View (SVDV), Vertical Dual View (VDV), and the dedicated Radial View (RV), the Agilent 5110 ICP-OES offers superior robustness, precision and productivity, delivering industry-leading sample throughput and the lowest gas consumption per sample. 5

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2016 Published May 1, 2016 Publication number: 5991-4842EN