Ness acomms Install & User Manual

Similar documents
Installation & Operation

My Visonic SMS App User Guide

Mobile App User Guide

Lynx Touch L5100 Technical Training. WiFi Setup

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Added password for IP setup page : Password must be in IP format!

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Alarm Getting Started

Outdoor External Strobe Siren. ADD-ON DEVICE Quickstart Guide. What's inside: 1x Outdoor External Strobe Siren

Advisor Advanced Mobile Application User Manual

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Avigilon Control Center System Integration Guide

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide

Ademco Vista Alarm Panel

SETTING UP DSC INTEGRATION THROUGH ENTRAPASS

Avigilon Control Center System Integration Guide

Using ANM Mobile CHAPTER

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

RFT CARES Android App User Guide

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

System Galaxy Quick Guide

Midco SmartHOME Quick Start Guide. Learn how to protect the things that matter most using this Midco SmartHOME instruction guide.

WiFi GSM APP Smart Home Security System

SIMPLIFIED HOME SECURITY AND CONTROL

8 / 16 Zone Control Panels with Cellular Dialler

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Wise&Cute WSC Series IP Cameras User-Manual

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

ADT Pulse Mobile App - Security

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

In Home Device Reference Guide. Brought to you by

PROGRAMMING. Alarm Control Panel. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel Firmware Version 1.

MultiSite Manager. Setup Guide

Chapter. Configuring OnSSI NetDVMS. OnSSI NetDVMS versions 5.x through 6.5g. OnSSI NetDVMS Ocularis. Configuring Third-Party Programs

Ness D8x / D16x Alarm Control Panel

status AW1 Plus WiFi Alarm System User Manual

Fall & Medical Alert Sensor

WELCOmE TO LIFESHIELD

Sevenoaks Smart Homes Safety and Security Guide

600 Range Dialer Installation Manual. Version 1.0

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Fall & Medical Alert Sensor

Uplink Remote Installation Guide 5500EZ

Wi-Fi 3-IN-1 Trio Sensor

Vcare. User Manual. Ver WiFi - GSM- App. Smart Home Security System

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

Automation. Smartphone Operation. Ness D8x / D16x alarm control panel. User's MANUAL. Revision 7.8.2

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

ismartalarm Home Security System OWNER S MANUAL

Chapter. Configuring Genetec Omnicast. Version 4.7 SR1. Configuring Third-Party Programs. SightLogix, Inc

Operating instructions V-ZUG-Home

K1 SMARTHOME DIY KIT

Protect and connect. Home and away.

Home center Interface Server. Technical sheet

Fratech Multipath-IP STU

PROGRAMMING. Alarm Control Panel. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel Firmware Version 1.

IntelliSync Thermostat / Mobile App Frequently Asked Questions

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Secure Your Way of Life. Now Compa ble With. Vesta Smart Security Solution - MZ Series

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

GLOBAL. InstallatIon & operation manual

S6 Titan Security System. Wi-Fi and 3G GSM

BAT WIFI SKU: IPD-BAT--WIFI

D3D Wi-Fi GSM Smart Alarm System -User Manual

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

nbn setup guide Fibre to the Curb (FTTC) Connecting to the nbn broadband access network 1

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps

B and G Series Integrated Security Solution

Alarm Manager Plug-in

PHD Dolphin Installation

Sync. Smart Home Alarm

HOME MANAGEMENT GATEWAY

IQ PANEL USER GUIDE SMARTHOME.

Sensi Multiple Thermostat Manager INSTALLATION GUIDE

T4000 Security Communicator

WELCOME TO CÔR HOME AUTOMATION HOMEOWNER S USER GUIDE. This Homeowner s User Guide will provide information to customize your Smarter Home.

Version 1.03 January-2002 USER S MANUAL

K1 SMARTHOME DIY KIT

Secure Your Way of Life. Now Compa ble With. Climax Home Portal Platform. Enable a Connected Future

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

Fratech Multipath-IP

YALE SECURE CONNECT. Delivering a premium digital locking solution with flexible control and peace of mind.

Security Management System Configuring TCP-IP MODBUS Inputs

Installing ProSeries 2005

Avigilon Control Center 5 System Integration Guide

IDoorBell Fon DP68 Quick Installation Guide

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys.

Installation, Configuration and User Manual

Patriot Systems Limited

Safer Smarter More Livable Buildings. TX3 Voice Entry & Access Control Solutions. [TX3] Series.

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

Simplex Panel Interface Guide

Innovative Circuit Technology Ltd.

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Professionally Monitored Service User Guide

Transcription:

Ness acomms Install & User Manual Phone GUI Tablet GUI 1 P age

TABLE OF CONTENTS Copyright Notice... 2 Important Information... 3 Ness D8x / D16x Versions... 3 D8x / D16x Two-Way Communication Settings... 3 Wiring Diagram... 4 Hardware / Parts Required... 4 IP232 Ethernet to Serial Bridge Settings... 5 Ness acomms Configuration Setup... 7 IP Address... 7 Port Number... 7 Panel Type... 7 Zone Names... 7 AUX Output Names... 7 Using the App... 8 Understanding the icons... 8 Arm to away mode... 9 Arm to Home / Monitor mode... 9 Activating Emergency Alarms... 10 Panic.... 10 Fire...... 10 Medical... 10 Viewing Zone status... 11 Controlling the AUX Outputs... 12 Troubleshooting... 13 Why Can t I contorl the AUX Outputs?... 13 I can t control anything on the panel using the app?... 13 Why doesn t the Panic, Fire or Medical buttons work?... 13 Can I Control my D8x / D16x over the internet using 3G?... 13 COPYRIGHT All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Ness. Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement. 2012 Ness Corporation Pty Ltd ABN 28 069 984 372 Android is a trademark of Google Inc 2 P age

IMPORTANT INFORMATION Ness D8x / D16x Versions The Ness acomms app only works with version 5.6 and above of the D8x and D16x PCB. To control the AUX outputs in the Ness acomms App you must be using a D8x/D16x PCB version 7.8 or above. D8x / D16x Two-Way Communication settings The two way communications on the D8x / D16x will only work if the following programming locations are enabled on the panel: P 199 E 1E ON: Send Address. 2E ON: Send Time Stamp 3E ON: Send Alarms. 4E ON: Send Warnings. 5E ON: Send Access Events. Panic, Medical & Fire control If you want to control the Panic, Medical & Fire in the Ness acomms app then you need to make sure you have the following programming locations enabled in the D8x or D16x. P 126 E 1E ON: (Double key PANIC) 2E ON: (Double key FIRE) 3E ON: (Double key MEDICAL) P 62 E 4E ON: Shortcut Keypad Panic P 64 E 7E ON: Keypad Fire Alarm (STD LCD KP) 8E ON: Keypad Medical Alarm (STD LCD KP) 3 P age

WIRING DIAGRAM The Ness acomms app requires the D8x / D16x to be on a TCP/IP network. Although the panel doesn t have a TCP/IP connection you are required to use an Ethernet to serial bridge to add the panel to your network. Ness Part Number K-6002 includes the D8x-D16x Serial Lead 3 Way Panel to DB9 and IP232 Ethernet to serial bridge which it required to connect your panel to the network. Hardware / Parts Required: 1 x D8x-D16x SERIAL LEAD 3 WAY - PANEL TO DB9 1 x IP232 ETHERNET TO SERIAL BRIDGE You need to connect the white serial plug into the D8x/D16x and connect the other end into the IP232 Ethernet to serial bridge as shown in the image above, and then you need to connect the IP232 Ethernet to serial bridge into a wireless router/switch. D8x/D16x Panel Black Blue White IP232 Ethernet to Serial Bridge PIN5 PIN2 PIN3 4 P age

IP232 ETHERNET TO SERIAL BRIDGE SETTINGS Before any connection can be made, you need to make a few changes in the IP232 Ethernet to serial bridge. To do this you need to open the IP232 Config Utility program which is available from the Ness product page for the IP232 Ethernet to Serial Bridge. You must be running at least version 1.1.0 or above of the IP232 Config Utility software. You need to make sure that you have your network cable plugged into the IP232 Ethernet to serial bridge and make sure that it s connected to the same network your computer is plugged into before continuing. Now you need to click on the Search button, this will go and search for these IP232 Ethernet to serial bridges on your network. Once it finds an IP232 Ethernet to serial bridge it will display down the bottom how many was found, as well as showing it in the dialog along with its MAC address and IP address. If it fails to find any IP232 Ethernet to serial bridges it will come up with the following error: 5 P age

Once it finds your IP232 Ethernet to serial bridge, click on it and select Configure. You now need to enter / change some settings in the configure screen. 1. You need to make sure you set the IP address to a static IP address. 2. You need to enter in an IP address for this RS232 Ethernet to serial bridge. This should be on the same network range as your Android device. (e.g. 192.168.0.xx) If you are unsure what IP settings to use you might need to contact the network administrator. 3. You need to set the Baud rate to 9600 as that is what the D8x/D16x communicates on. 4. The TCP Port to accept connections should be set to 2401. This port number can be anything, but recommended to use the default 2401. 5. Once the settings have been entered, click on the Send Settings (to IP232) button. This will apply all the settings to the IP232 Ethernet to serial bridge. 6 P age

NESS ACOMMS CONFIGURATION SETUP When you run Ness acomms for the first time, it will ask for your network settings as shown below: You can also view this screen at a later time by pressing the settings button up the top right of the main screen. IP Address The IP Address is what you entered into the IP232 Ethernet to serial bridge from the previous page. Your Android Device is required to be on the same IP network and network range as your IP232 Ethernet to serial bridge. If you are connecting to your panel over 3G (mobile network) then port forwarding is required to your network. Please refer to portforwading.com on how to set that up. Port Number The Port Number is what you entered into the IP232 Ethernet to serial bridge from the previous page. Default Port is 2401. Panel Type You need to select the Panel Type of your panel that you are using. If you are using an 8 zone panel select Ness D8x, if your panel is a 16 zone panel then choose Ness D16x. Zone names By pressing the Edit Zone Names allows you to edit the name of the zone which you see in the GUI. AUX Output Names By pressing the Edit Output Names allows you to edit the name of the Output which you see in the GUI. 7 P age

USING THE APP Understanding the icons Area is Disarmed Zone is Normal Area is Armed Zone has be violated Area is Armed to Monitor / Home Mode Zone is in alarm Area is Armed to Day Mode Panic / Fire / Medical is active Panel has a low Battery Panic / Fire / Medical is Normal Panel is alarm AUX / Output is OFF AUX / Output is ON 8 P age

Arm to away mode To arm the panel, you need to press the Arm button followed by your user code then press the E button. Arm to home / monitor mode To arm the panel to home/monitor mode, you need to press the Home button followed by your user code then press the E button. This feature needs to be enabled in the panel. Disarm the panel from away or home / monitor mode To disarm the panel, you just need to enter in your user code followed by the E button. 9 P age

ACTIVATING EMERGENCY ALARMS The Panic, Fire and Medical alarms will only work if it s been enabled in the panel. You have 3 different alarms to choose from: Panic Fire Medical Once you tap on the alarm buttons (Panic, Fire, Medical) it will ask you to confirm if you really want to activate the alarm before it sends the request to the panel. This is in case you tap it by mistake. Panic The panic button will send a panic alarm to the alarm panel. Fire The Fire button will send a fire alarm to the alarm panel. Medical The Medical button will send a medical alarm to the alarm panel. 10 P age

VIEWING ZONE STATUS You can view the zone status from the panel by clicking on the Zones button up the top left of the screen. If you are running a tablet and the screen is 7 or bigger, then the zones button will not appear on the screen as the zones will be on the screen already. There are 3 different states Zone Normal Zone Violated Zone is in alarm Each zone status is updated automatically when a zone is violated or becomes back to normal. You can rename each zone name by opening the settings screen. Phone GUI Tablet GUI 11 P age

CONTROLLING THE AUX OUTPUTS To control the AUX Outputs in the Ness acomms app, you must have a version 7.8 or above of the D8x/D16x PCB. You can tap the AUX Output to activate/deactivate the output at any time. The AUX outputs have 2 states: AUX Output is OFF / Normal AUX Output is ON / Active You can rename each AUX Output name by opening the settings screen. 12 P age

TROUBLESHOOTING Why can t I control the AUX Outputs? The outputs can only be controlled by version 7.8 and above on the D8x / D16x. Although you can use the outputs on the keypads (such as the navigator keypad or KPX) and view the status in the Ness acomms app, there is no serial protocols in earlier boards to turn the output on or off via the serial port. I can t control anything on the panel using the app? The Ness acomms app will only work if the following is enabled on the panel: P 199 E 1E: ON (Send Address.) 2E: ON (Send Time Stamp) 3E: ON (Send Alarms.) 4E: ON (Send Warnings.) 5E: ON (Send Access Events.) 6E: ON (Send Zone Seal State. (D8x/D16x V6 and later.)) Make sure your IP address isn t being used by another device on your network, and make sure you Android device is connected to the same network as the panel. Why doesn t the Panic, Fire or Medical buttons work? Make sure you have the following programming locations enabled in the panel: P 126 E 1E: ON (Double key PANIC) 2E: ON (Double key FIRE) 3E: ON (Double key MEDICAL) P 62 E 4E ON: Shortcut Keypad Panic P 64 E 7E: ON Keypad Fire Alarm (STD LCD KP) 8E: ON Keypad Medical Alarm (STD LCD KP) Can I control my D8x / D16x over the internet using 3G? Yes, however you will need to enable Port Forwarding in your router. For more information on how to enable port forwarding please visit www.portforwarding.com for detailed step-by-steps on port forwarding. 13 P age