talentum Flame detection across the spectrum Range Brochure

Similar documents
Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Talentum - Why use our Flame Detectors?

Conspec - Why use our Flame Detectors

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

FIRE IR SENSOR Flame Detection

Range brochure. Beam detection. others look up to.

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual

Flame Detector User Manual

Flame Detection Jon Sarfas

Talentum Flame Detector User Guide

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

Dräger Flame 2100 Flame Detection

Dräger Flame 2500 Flame Detection

LEARNING SPECIAL HAZARD DETECTION TYPES

Infra-Red Transit Heat and Flame Sensors. Early warning fire detection to protect conveyors, product and plant

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Dräger Flame 2500 (IR3) Flame Detection

Fire Detection System: An Overview

SharpEye Flame Detector Selection Guide

Dräger Flame 2700 (Multi-IR) Flame Detection

UniVario Industrial Fire Detectors Versatile in Application

MSA s Guide to Selecting the Right Flame Detector for Your Application

CCTV, HOW DOES IT WORK?

Introduction to Fire Detectors Training Manual

Instruction manual for the Infrared Point Type Flame Detector

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

InstrumentationTools.com

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

Dräger Flame 2100 (UV) Flame Detection

Dräger Polytron Pulsar 2 Open Path Gas Detector

Pyroelectric Infrared Sensor PIR

Meeting NFPA standards for

Dräger Flame 2350 (UV&IR) Flame Detection

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

TRIPLE WAVEBAND INFRARED FLAME DETECTOR

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

DF1151-Ex Infrared flame detector

W-FLAME IR/UV FLAME DETECTOR

Fixed Gas Detection Equipment

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Flame 2370 (UV&IR) Flame Detection

Fire Detection systems. UniVario industrial fire detectors for every job

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

The SharpEye 40/40I (IR3) Flame Detection

APPLICATION OF VISUAL FLAME DETECTION

Model 3300 Technical Support and Installation Manual

Chemical Processes in the Combustion

COMPACT FLAME CONTROLLER CFC 1000

HigH Performance Low cost flame Detection. Courtesy of Foster + Partners. The New 20/20M MINI FLAME DETECTOR SERIES

T.ex Single Gas Detector VISA

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Design Manual Installation Operation Maintenance

Applying Neural Network Technology to the Next Generation Flame Detector

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

COMPACT FLAME CONTROLLER CFC 2000

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Datalogging as standard

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

Contents. 1. Fire Detection motivation. 2. SharpEye Detector Range. 3. Detector Accessories. 4. How to Specify & Locate Detectors

Basic Vehicle Fire Protection Manual

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Infrared Flame Detectors

Eclipse Self-Check UV Scanner

intrinsically safe detector for hydrocarbon gases

PDF- VERSION ADJUSTED FROM THE BROCHURE. tissue. How to protect tissue mills from fire

UV - flame detector dual fuel burners for intermittent burner operations

Infrared Flame Detectors

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

DF1101-Ex Infrared flame detector

SIMRAD GD10 IR GAS DETECTOR

Flame Monitors BROCHURE

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

FIREYE C9707A ALL FUEL SCANNER

Dräger GS01 (wireless) Detection of flammable gases and vapours

The SharpEye 40/40R (IR) Flame Detection

Smart Fire Prevention

The SharpEye 40/40M (Multi IR) Flame Detection

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

3600 Series UV/IR Flame Detector Models

RS Pro Infrared Temperature Sensor

Industrial fire alarm systems

G-TECTA TM. Portable Gas Detection Instruments

Dräger Flame 3000 Visual Flame Detector Instructions for Use

OMA-300 Process Analyzer

TECHNICAL REPORT OG MSA 20/20MI Flame Detector Evaluation, 2004

Distributed By: M&M Control Service, INC

Safety Engineering. Fire Protection Systems and Life Safety Systems

This training course discusses the correct use of Infrared (IR) Optical Beam Smoke Detectors for the protection of lives, equipment and property.

Transcription:

talentum Flame detection across the spectrum Range Brochure

Talentum - Why use our Flame Detectors... Talentum Flame Detectors are ideal for applications where fast acting and accurate detection of fire is essential. Using infra-red (IR) sensing technology they can detect flames from all fuel types, from hydrocarbon fires with 4.3µm emissions through to invisible fires such as hydrogen. Talentum detectors can detect flames through such elements as dust, steam and smoke; they are also immune to the effects of wind or draughts of air. With the addition of an ultra-violet (UV) sensor Talentum detectors are highly immune to false signals such as sunlight. The detectors use advanced infrared (IR) and ultraviolet (UV) technologies, making Talentum one of the fastest, most reliable and accurate flame detectors in the world. It s technology is truly unique, looking at both the characteristic flicker and energy produced by flames. Talentum is the detector of choice for high value, high risk applications - varying from nuclear power plants, waste disposal plants to supersonic cars, Talentum provides detection you can trust. Product Support FFE offer design assistance for Talentum flame detection applications, ensuring that you have the correct detectors for the application, as well as providing drawings to assist you with installation. In addition, training programmes for the Talentum range are available. This can be tailor-made to suit you and your company, and are held typically at the FFE head office in Hitchin, UK by our in-house technical support team. Warranty FFE include an industry-leading 3-year warranty as standard on all of the Talentum Flame Detectors. talentum Flame detection across the spectrum

Product Range IR² Flame Detector (Dual Infra-red) High immunity to false sources (for indoor areas) IR³ Flame Detector (Triple Infra-red) Excellent immunity to false sources (for indoor or outdoor areas) UV / IR² Flame Detector (Ultra-Violet, Dual Infra-red) Highest immunity to false sources (for indoor or outdoor areas) IR Rear Facing Flame Detector (Single Infra-red) Specialist applications (for enclosed and dark areas) Applications Applications Applications Applications Compressor Stations Chemical Plants Tunnels Waste Recycling Nuclear Power Plants Engine Rooms Spray Booths Pharmaceutical Production Military & Marine Coal Handling Printing LNG/LPG Production Refineries Compressor Stations Fuel Loading Racks Chemical Plants Tunnels Waste Recycling Nuclear Power Plants Storage Tanks Engine Rooms Spray Booths Pharmaceutical Production Military & Marine Coal Handling Printing Biomass Storage & Dandling LNG/LPG Production Refineries Generators Compressor Stations High Voltage Equipment Power Plants Fuel Loading Racks Chemical Plants Tunnels Nuclear Power Plants Storage Tanks Engine Rooms Aircraft Hangers Pharmaceutical Production Military & Marine Petrochemical LNG/LPG Production Agriculture Bed Fillings Coal Milling Dryers Dust Collection & Filters Felt Manufacture Wallpaper Production Woodworking www.ffeuk.com

Dual IR (IR²) Flame Detectors These detectors are sensitive to flickering, low frequency (1 to 15Hz) infra-red (IR) radiation emitted by flames during combustion. Should the lens become contaminated by a layer of oil, dust, water, vapour or ice, the unit will remain an effective flame detector. The detector has two infra-red (IR) sensors which respond to different infra-red (IR) wavelengths in order to discriminate between flames and spurious sources of radiation. They are ideal for applications where visible light is present. IR² Flame Detector (Part No. 16581) High optical interference immunity IR² Flame Detector - Intrinsically Safe (IS) (Part No. 16571) High optical interference immunity IR² Flame Detector - Flameproof (Exd) (Part No. 16511) High optical interference immunity Triple IR (IR³) Flame Detectors These detectors have high immunity to false alarms. They are sensitive to flickering, low frequency (1 to 15Hz) infra-red (IR) radiation emitted by flames during combustion. They will continue to function under the most difficult of conditions, even if the lens is contaminated by a layer of oil, dust, water, vapour or ice. The detector has three infra-red (IR) sensors which respond to different infra-red (IR) wavelengths in order to discriminate between flames and spurious sources of radiation. They are ideal for indoor or outdoor applications. IR³ Flame Detector (Part No. 16589) Excellent optical interference immunity IR³ Flame Detector - Intrinsically Safe (IS) (Part No. 16579) Excellent optical interference immunity IR³ Flame Detector - Flameproof (Exd) (Part No. 16519) Excellent interference immunity talentum Flame detection across the spectrum

UV / IR² Flame Detectors These detectors give the highest immunity to false alarms. They are sensitive to flickering, low frequency (1 to 15Hz) infra-red (IR) radiation along with ultra-violet (UV) emitted by flames during combustion. The detector has a ultra-violet (UV) sensor and two infra-red (IR) sensors that respond to different wavelengths from both the ultra-violet (UV) and the infra-red (IR) spectrum. False alarms from flickering sunlight, arc welding and lightning are eliminated by a combination of ultra-violet (UV) and dual infra-red (IR) signal processing techniques.they are ideal for indoor or outdoor applications. UV / IR² Flame Detector (Part No. 16591) Highest optical interference immunity UV / IR² Flame Detector - Flameproof (Exd) (Part No. 16521) Highest optical interference immunity Single IR Rear Viewing Specialist Flame Detectors The Single IR Rear Viewing specialist flame detector is designed for machine applications to protect enclosed, dark areas where visible light is not present. This detector has high sensitivity to flame and sparks and has a very fast response time. The detector has one infra-red (IR) sensor, which is selective to low frequency modulated infra-red (IR) radiation such as that emitted from flames and sparks. The detector rejects static radiation from sunlight and artificial lighting. Single IR Rear Viewing Flame & Spark Detector for Bayonet Mounting (Part No. 16580) Continues operation at temperatures up to 55 C Ideal for use on machinery protection applications Suitable for enclosed and dark areas Single IR Intrinsically Safe Rear Viewing Flame & Spark Detector for Bayonet Mounting (Part No. 16570) Intrinsically safe (IS) for hazardous areas. Ideal for use on machinery protection applications Suitable for enclosed and dark areas www.ffeuk.com

Specialist Application Detectors IR² Flame Detector - Stainless Steel (Part No. 16501) IR² Flame Detector - Stainless Steel, Flameproof (Exd) (Part No. 16541) SIL 2, ATEX & IECEx certified IR³ Flame Detector - Stainless Steel (Part No. 16509) IR³ Flame Detector - Stainless Steel, Flameproof (Exd) (Part No. 16549) SIL 2, ATEX & IECEx certified IR³ Flame Detector - Flameproof (Exd), High Ambient Temperatures (Part No. 16219) Continuous operation at temperatures up to 85 C, short term operation at temperatures up to 125 C ATEX & IECEx certified UV / IR² Flame Detector - Stainless Steel (Part No. 16531) UV / IR² Flame Detector - High Ambient Temperatures (Part No. 16291) Continuous operation at temperatures up to 85 C, short term operation at temperatures up to 125 C UV / IR² Flame Detector - Flameproof (Exd), High Ambient Temperatures (Part No. 16221) Continuous operation at temperatures up to 85 C, short term operation at temperatures up to 125 C ATEX certified UV / IR² Flame Detector - Stainless Steel, Flameproof (Exd) (Part No. 16561) SIL 2 & ATEX certified talentum Flame detection across the spectrum

Talentum Accessories Adjustable Mounting Bracket (Part No. 07127) Stainless steel 316 Suitable for all front viewing detectors Electrical Isolation Mount for Brackets (Part No. 07296) Quick release clips Marine grade materials Stainless Steel Weather Shield (Part No. 12545) For all alloy housings Stainless Steel 316 Weather Shield (Part No. 07310) For all Exd housings Flame Detector Test Unit (Part No. 16091) Portable with rechargeable battery pack and charger Wide spectral output; UV, visible, near-ir, mid-ir Selectable output; constant, regular flash, irregular flicker Includes transport case Rear Viewing Detectors Accessories Bayonet - Mount 1 BSP/NPT Male (Plated Steel) (Part No. 12290) Bayonet - Blanking Plug (Solid) (Part No. 12453) 2 Hole Mounting Flange Kit (Part No. 12564) 1" BSP/NPT (No window) For use with bayonet mount 12290 4 Hole Mounting Flange with 1 BSP/NPT (Part No. 12561) Pyrex window 5.5mm thick High temperature gaskets and fixings For use with bayonet mount 12290 Purge Air Adaptor (Part No. 12543) 1/4" BSP air inlet to keep viewing window clear from heavy dust contamination For use with 2 hole mount 12564 Purge Air Adaptor (Part No. 12544) 1/4" BSP air inlet to keep viewing window clear from heavy dust contamination For use with 4 hole mount 12561 www.ffeuk.com

US Sales and Distribution FFE Limited 1455 Jamike Ave Ste 200 Erlanger KY 41018-3147 USA Head Office HQ FFE Limited 9 Hunting Gate Hitchin, Hertfordshire SG4 0TJ England ffe t +1 859 957 1570 f +1 972 534 1526 e america@ffeuk.com w www.ffeuk.com t +44 (0) 1462 444 740 f +44 (0) 1462 444 789 e sales@ffeuk.com w www.ffeuk.com Worldwide Offices Worldwide Technical Support t +44 (0) 1462 444 740 f +44 (0) 1462 444 789 e technical@ffeuk.com Middle East Sales Office Dubai UAE e middleeast@ffeuk.com w www.ffeuk.com India Sales Office Mumbai India e india@ffeuk.com w www.ffeuk.com China Sales Office Shanghai China e china@ffeuk.com w www.ffechina.com Formerly known as Fire Fighting Enterprises Ltd Document Part No: 24-0097-01