Instructions for Use and Reprocessing Instructions

Similar documents
Instructions for Use Spinal Punches IFU

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

CLEANING INSTRUCTIONS

RECOMMENDATIONS FOR CLEANING DEVICES

Recommendations for cleaning, decontamination and sterilisation. devices

Cleaning & Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Aesculap Implant Systems

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Important information

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

Aesculap Implant Systems

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

FLASH PAK STERILIZATION CONTAINER SYSTEM

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Cleaning and Sterilization for Instruments & Posts

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

I.F.U Re/Processing Reusable Medical Devices

Cleaning and Sterilisation for Burs, accessories and filling material

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

2015 Myco Industries, Inc Fax:

When you sterilize an instrument set, you know what the standards are.

Instructions for Use: Endoplus Modular Handle Assemblies, Multi-Use Scissors Inserts, Reusable Inserts

Reusable Laryngoscope Blades and Handles

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

STERITITE INSTRUCTIONS FOR USE

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

THE BASICS OF DECONTAMINATION

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Operating / User Manual

Reprocessing Instructions for Reusable Surgical Instruments English

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

Processing instructions for the Ligamys suture forceps

Reprocessing Instructions for Reusable Surgical Instruments English

STERIS Instrument Cleaning Chemistries

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Processing Instructions. Cleaning so easy.

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

RAP-hip Hip stem extraction set

Instructions for Cleaning, Sterilization, Inspection and Maintenance. of Trauma & Extremities Medical Devices

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

Air-driven Universal Power Tool System for Traumatology, Endoprosthetics, and Spine. Compact Air Drive II. Instructions for Use

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

idrive Ultra Powered Stapling System

The Principles, The Process, and The Results:

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

Instrument Cleaning Chemistries Automated Washing Process

X99 Series. Dental Handpiece. Instruction For Use

Classification of Instruments -

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

User s Manual. Small Electric Drive. Compact and powerful system for use in hand and foot surgery.

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

CLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method.

Do not attempt to adjust or disengage the spring on the handle.

Visao HIGH-SPEED OTOLOGIC DRILL CATALOG

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners

REUSABLE ENDOSCOPY INSTRUMENTS (thermo resistant)

Instruction of use. Flexible Naso-Pharyngo- Laryngofiberscope,

Cavitator Ultrasonic Cleaner Instruction Manual

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Instructions for Use (GA16)

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

PERFORM Operating Document

Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products

Instructions for Use: Fiberscope and LED Light Source

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

ComPact Air Drive II USER S MANUAL

Cavitator Ultrasonic Cleaners

BioSonic Ultrasonic Cleaning Systems. biosonic.coltene.com

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

HTM made easy. Testing Explained... in fact everything you need to know about HTM but were too afraid to ask!

Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates

Lower Your Costs. Expand Your Flexibility.

Pocket Hardmount. Preventative Maintenance.

Fiona Collins Liliana Donatelli Andrew Smith

Additionally, consider the legal provisions valid for your country as well as to the hygienic instructions of the doctor s practice or hospital.

Transcription:

0902-90-044-EN Rev. J 0086 Instructions for Use and Reprocessing Instructions Revised June 2017 DePuy Synthes 2017. All rights reserved

en Instructions for Use and Reprocessing Instructions CAUTION: USA law restricts these devices to sale by or on the order of a physician. Section 1 outlines information for sterile devices. Section 2 outlines information for cleaning and sterilization of single use devices. Section 3 outlines information for cleaning and sterilization of reusable surgical instruments. Most instrument systems include inserts/trays and a container(s). Many instruments are intended for use with a specific implant. It is essential that the surgeon and operating room staff is fully conversant with the appropriate surgical technique for the instruments and associated implant, if any. DePuy Synthes Instruments do not have an indefinite functional life. All reusable instruments are subjected to repeated stresses related to bone contact, impaction, routine cleaning, and sterilization processes. Instruments should be carefully inspected before each use to ensure that they are fully functional. Scratches or dents can result in instrument breakage or soft tissue injury. Care should be taken to remove any debris, tissue or bone fragments that may collect on the instrument. Metal instrument or its fragments can be located by means of an external imaging device (e.g. X-ray, CT scanner). The limits of accuracy for instruments with a measuring function will vary between instruments from different product systems; the greatest limit of accuracy for an instrument with a measuring function is ± 15%. Power instrumentation of the EXPEDIUM and EXPEDIUM Verse System consisting of drill bits, taps and screwdrivers are compatible for use with the Colibri II (532.101) and Small Battery Drive II (532.110) Power Tool Systems for orthopedic and general surgery procedures. Expedium Verse power instrumentation consisting of power facilitator (299704205P), power X25 inserter (299704230P), and power correction key inserter (299704220P) attachments are compatible with the MatrixPro Driver (05.000.020) distributed by DePuy Synthes CMF for the insertion of Expedium Verse set screws. Users should consult the technique guide or the Instructions for Use of the concerned system for specific instructions in the use of powered instruments. Precaution: DePuy Synthes Neural Tissue Instruments are intended for use in the Peripheral Nervous System only. Neural Tissue Instruments are tools used by surgeons during spinal surgery to facilitate visualization of the neuroanatomy and disc space and to retract and reposition, probe and provide suction around the dural sac and nerve roots allowing safe passage of other spinal instrumentation and implants. During spinal surgery revision procedures, the surgeon may utilize the nerve root instruments to dissect or separate scar tissue and adhesions, such that these tissues may be safely mobilized or repositioned during disc space access and decompression. 2 of 16

SECTION 1. FOR STERILE DEVICES, THE FOLLOWING INSTRUCTIONS APPLY: For the devices (implants and instruments) supplied sterile, the contents are sterile unless the package is damaged, opened, or the expiration date on the device label has passed. The integrity of the packaging should be checked to ensure that the sterility of the contents is not compromised. Remove devices from packaging, using aseptic technique, only after the correct size has been determined. PRECAUTION: Do not use devices if the condition of the package and/or labeling indicates a chance that the devices may not be sterile. Devices supplied sterilized from the manufacturer must not be resterilized. SECTION 2. FOR SINGLE USE NONSTERILE DEVICES, THE FOLLOWING INSTRUCTIONS APPLY: SINGLE USE DEVICES SHOULD NOT BE REUSED. Reuse can compromise device performance and patient safety. Reprocessing or resterilization may lead to changes in material characteristics, which may impact the device performance and patient safety. Reuse of single-use devices can also cause cross-contamination leading to patient infection. SECTION 3. FOR REUSABLE INSTRUMENTS, THE FOLLOWING INSTRUCTIONS APPLY: These reprocessing instructions apply to: Reusable surgical instruments supplied by DePuy Synthes Instruments intended for reprocessing in a health care facility setting These reprocessing instructions have been validated as being capable of preparing reusable DePuy Synthes instruments for reuse. It is the responsibility of the reprocessor to ensure that the reprocessing is actually performed using appropriate equipment, materials, and personnel to achieve the desired result. This normally requires validation and routine monitoring of the process. Any deviation by the reprocessor from these instructions should be evaluated for effectiveness and potential adverse consequences. Please telephone DePuy Synthes Customer Service at (800) 365-6633 or (508) 880-8100 if you need additional assistance. WARNINGS AND CAUTIONS These instructions are provided for the processing of heat-resistant, immersible, critical medical devices, unless otherwise noted on specific product inserts. Product specific inserts are given priority over these instructions. This can include heat-sensitive devices and certain power (air- or electricdriven) tool designs that are provided with specific cleaning and sterilization instructions. Consult the product specific instructions for processing in these cases. 3 of 16

The instructions provided are given as guidance for medical device processing and have been validated by the manufacturer. It is the responsibility of the healthcare facility to ensure that processing is performed using the required equipment, materials and personnel at a defined processing area. This will include the handling of devices during transportation, processing and storage prior to surgical use. Those using these instructions should be qualified personnel with documented training and competency in accordance with local procedures, guidelines, and standards. Surgically used instruments can be considered biohazard and facilities should ensure that transport and handling procedures comply with local regulations and guidelines. Sterile, single use implants must not be reprocessed or reused. Sterile implants are labelled as single use and have not been validated for reprocessing. Non-sterile implants must be processed prior to use in accordance with these processing instructions. They may be subjected to reprocessing in accordance with these processing instructions, but they must be discarded following direct patient contact or use. Reusable, non-sterile surgical instruments are required to be cleaned, inspected and sterilized prior to surgical use. Care should be taken in the handling and cleaning of sharp devices. All devices must be thoroughly cleaned and inspected prior to sterilization. Long, narrow lumens, blind holes, moving and intricate parts require particular attention during cleaning and inspection. During cleaning, only use detergents that are labelled for use on medical devices and in accordance with the manufacturer s instructions. Cleaning agents with a used dilution ph of within 7 9 are recommended. Highly alkaline conditions (ph>10) can damage components / devices, such as aluminium materials. Do not use saline, environmental disinfection (including chlorine solutions) or surgical antiseptics (such as iodine- or chlorhexidine-containing products). Do not use a cleaning aid that can damage the surface of instruments such as steel wool, abrasive cleaners or wire brushes. Instruments should be carefully inspected before each use to ensure that they are functional. Scratches, dents or other damage can result in instrument breakage or tissue injury. Instruments must be cleaned separately from instrument trays and cases. Instrument trays and cases are designed as an organizational tool in preparation for sterilization, storage and surgical use. Non-sterile implant sets may be processed in their trays provided. Automated equipment, including washer-disinfectors and steam sterilizers must be installed, maintained and operated in accordance with manufacturer s instructions. Do not exceed 140 C (284 F) during reprocessing steps. For patients with, or suspected with, Creutzfeldt-Jakob disease (CJD), variant CJD or other transmissible spongiform encephalopathy (TSE) and related infections, it is recommended to treat the patient using single-use instruments. Safely dispose of all devices used in accordance with local procedures and guidelines. 4 of 16

LIMITATIONS ON PROCESSING Repeated processing cycles in compliance with these instructions for use have minimal effects on device life and function. Instruments do not have an indefinite functional life. End of life of devices is determined by wear and damage due to surgical use and handling. Evidence of damage and wear on a device may include but is not limited to corrosion (i.e. rust, pitting), discoloration, excessive scratches, flaking, wear and cracks. Improperly functioning devices, devices with unrecognizable markings, missing or removed (buffed off) part numbers, damaged and excessively worn devices should not be used. Non-sterile implants must be discarded following patient use. Any implant with evidence of damage, such as due to handling or processing must be discarded. Step 1: Point of Use Care Ensure that no instruments or parts are left in the surgical site prior to closure as patient injury may result. All single use devices and materials should be removed and discarded in compliance to local policies. The drying of gross soil (blood, tissue and/or debris) on devices following surgical use should be avoided. It is preferred that gross soil is removed from devices following use and in preparation for transportation to a processing area. Gross soil can be removed using sponges, cloths, or soft brushes. Water and/or cleaning detergents (labelled for use on medical devices) may be used. Do not use saline, environmental disinfection (including chlorine solutions) or surgical antiseptics (such as iodine- or chlorhexidine-containing products. Flush all lumened devices with water (or detergent solution) to prevent the drying of soil and/or debris to the inside. If gross-soil cannot be removed at the point of use, the devices should be transported to prevent drying (e.g., covered with a towel dampened with purified water) and cleaned as soon as possible at a designated processing area. Surgical cement should be removed from devices during surgical use and prior to setting. When cement hardens it will typically require physical methods to remove. Chemical solvents should not be used. Hardened cement may be removed with an approved stylus or removing tool, but these may damage devices. Step 2: Containment and Transportation Surgically used devices may be considered bio-hazardous and should be safely transported to a designated processing area in accordance with local policies. Step 3: Cleaning Preparation before Cleaning It is recommended that devices should be reprocessed as soon as is reasonably practical following surgical use. Instruments must be cleaned separately from instrument trays and cases. Non-sterile implants may be cleaned and disinfected in the provided implant trays. 5 of 16

Care should be taken in the handling and cleaning of sharp devices. These are recommended to be cleaned separately to reduce risks of injury. Multi-part or complex instruments may require disassembly for cleaning. Refer to any technique guides or other supplemental information for specific device disassembly and/or reassembly instructions. Any devices with moving parts (e.g. ratchets, box locks, hinges or actuated parts) need to be actuated during manual cleaning to ensure access of the cleaning process. All devices with lumens need to be manually flushed to remove debris and brushed thoroughly using appropriately sized soft-bristled brushes and twisting action. Brush size should be approximately the same diameter of the lumen to be cleaned. Using a brush that is too big or too small for the diameter of the lumen/cannulation may not effectively clean the lumen. Refer to any technique guides or other supplemental information for specific device lumen diameters. After brushing, rinse with water by flushing and blow clean compressed air through all lumens. NOTE: Two cleaning methods are provided, a Manual and an Automated Method, and at least one shall be performed. Cleaning: Manual 1. Prepare a neutral or mild alkaline cleaning solution (ph 7 to 9) in accordance to the detergent manufacturer s instructions. The temperature of the solution should be 40 C (104 F) for manual cleaning. NOTE: The cleaning solution may contain enzymes. Aluminum-safe alkaline cleaners can be used, but can vary in material compatibility overtime based on their formulation. Material compatibility should be confirmed with the detergent manufacturer. 2. Immerse devices and parts in the detergent solution, and soak for a minimum of 5 minutes. 3. While immersed, use a soft non-metallic bristle brush (plastic bristles, like nylon) or sponge to thoroughly clean all traces of blood and debris from all device surfaces for a minimum of one minute. 4. Ensure all lumens are thoroughly brushed. Push the brush through the entire length of the lumen using a twisting motion to remove debris from both ends for a minimum of one minute. 5. During cleaning, actuate joints, handles and other movable device features to expose all areas to the detergent solution, if applicable. Ensure all lumens are flushed for a minimum of one minute. 6. Remove the devices and completely submerge in an ultrasonic bath prepared with a neutral or mild alkaline ph detergent (ph 7-9), prepared in accordance with the manufacturer s instructions. Use a large syringe (50ml or greater) flush all lumens with the cleaning solution, articulating areas, and flexible segments with the detergent solution to minimize the formation of air pockets or bubbles. NOTE: Ultrasonic cleaning is only effective if the surface to be cleaned is immersed in the cleaning solution. Air pockets will decrease the efficacy of ultrasonic cleaning. 7. Ultrasonically clean the device components for a minimum of 10 minutes in accordance with manufacturer s instructions. An example of a validated cycle used for cleaning validation included 40kHz at 25 C for 10 mins). 6 of 16

8. Rinse all devices by immersion in ambient, < 40 C (104 F), tap water for a minimum of one minute and until evidence of debris, soil, and cleaning solution are visually removed. Use a large syringe (e.g., 50ml or greater) filled to capacity with tap water to thoroughly flush lumens and channels. Actuate joints, handles and other moveable device features to rinse thoroughly. 9. Remove the devices and repeat the rinsing using in ambient, < 40 C (104 F) critical water (high purity water generated by processes such as RO, deionization or distillation) for at least 15 seconds. 10. Remove and dry device using a clean, soft, lint-free cloth or clean compressed air. Ensure that all lumens and articulated areas are dried using compressed air. Cleaning: Automated 1. Prepare a neutral or mild alkaline cleaning solution (ph 7 to 9) in accordance to the detergent manufacturer s instructions. The temperature of the solution should be 40 C (104 F) for manual cleaning. NOTE: The cleaning solution may contain enzymes. Aluminum-safe alkaline cleaners can be used, but can vary in material compatibility overtime based on their formulation. Material compatibility should be confirmed with the detergent manufacturer. 2. Immerse devices and parts in the detergent solution, and soak for a minimum of 5 minutes. 3. While immersed, use a soft non-metallic bristle brush (plastic bristles, like nylon) or sponge to thoroughly scrub all traces of blood and debris from all device surfaces for at least one minute. 4. Ensure all lumens are thoroughly brushed. Push the brush through the entire length of the lumen using a twisting motion to remove debris from both ends for at least one minute 5. During cleaning, actuate joints, handles and other movable device features to expose all areas to the detergent solution, if applicable. Ensure all lumens are flushed for at least one minute. 6. Load the device components in the washer-disinfector in accordance with manufacturer s instructions, ensuring that the devices and lumens can drain freely. 7. Automated washing shall be conducted in a validated washer-disinfector in compliance to ISO 15883-1 and-2, or to an equivalent standard. Automated washing can be included as part of a validated washing, disinfection, and/or drying cycle in accordance to manufacturer s instructions. An example of a validated cycle used for cleaning validation included: Recirculation Phase Time (mins) Water Temp Detergent/Water Type Pre Wash 2 Cold Tap Water N/A Enzyme wash 1 < 40 C (104 F) Neutral, Enzymatic Cleaner Wash 5 66 C (151 F) Neutral ph Detergent Rinse 2 > 40 C (104 F) Tap water Critical water (RO, deionized Rinse 0.25 Ambient or distilled water) 7 of 16

Step 4: Thermal Disinfection Thermal disinfection is recommended to render devices safe for handling prior to steam sterilization. Thermal disinfection should be conducted in a washer-disinfector compliant to ISO 15883-1 and-2, or to an equivalent standard. Thermal disinfection in the washer-disinfector shall be validated to provide an A 0 of at least 600 (e.g., 90 C (194 F) for 1 min). Higher levels of A 0 can be achieved by increasing the exposure time and temperature (e.g., A 0 of 3000 at >90 C (194 F) for 5 min, in accordance with local requirements). Load the device components in the washer-disinfector in accordance with manufacturer s instructions, ensuring that the devices and lumens can drain freely. Evenly rinsed surfaces can achieve required heating curve for thermal disinfection. If possible use an irrigating rack /load carrier with connections designed to ensure an adequate flow of process fluids to the lumen or cannulation of the device if provided. The following automated cycles are examples of validated cycles: Recirculation Phase Time (mins) Water Temp Water Type Critical water (RO, deionized Thermal Disinfection 1 > 90 C (194 F) or distilled water) Critical water (RO, deionized Thermal Disinfection 5 > 90 C (194 F) or distilled water) Step 5: Drying It is recommended that drying is conducted in a washer-disinfector compliant to ISO 15883-1 and-2, or to an equivalent standard. Drying efficiency in washer-disinfectors can range considerably based on the automated system design and load configuration. The following automated cycle is an example of a validated cycle: Recirculation Time Air Temp Max. Phase Min. (minutes) C ( F) Air Type Dry 7 140 (284) Medical grade Following automated drying, inspect the device for residual moisture. Any residual moisture identified should be dried manually (as described below). For manual drying: Ensure each device is dried and inspected thoroughly. For external surfaces, use a clean, soft, lint-free cloth to avoid damage to the surface. Open and close any applicable devices during drying. Pay special attention to any device threads, ratchets and hinges or areas where fluid can accumulate. Clean, compressed air (e.g., medical grade) may be used to facilitate surface drying. Dry all lumen/cannulated parts using clean compressed air (e.g., medical grade). 8 of 16

Step 6: Maintenance and Inspection Instruments should be visually inspected under ambient lighting, to verify that the devices do not have visible soil, damage or moisture. Inspect devices for: Lack of moisture. If moisture is detected, manually drying should be performed. Cleanliness. If any residual soil is discovered during inspection, repeat the cleaning steps on those devices until all visible soil is removed from the device. Damage, including but not limited to, corrosion (rust, pitting), discoloration, excessive scratches, flaking, cracks and wear Proper function, including but not limited to, sharpness of cutting tools, bending of flexible devices, movement of hinges/joints/box locks and moveable features such as handles, ratcheting and couplings and missing or removed part numbers Improperly functioning devices, devices with unrecognizable markings, missing or removed (buffed off) part numbers, damaged and worn devices should be discarded. Disassembled devices should be reassembled prior to sterilization when specified. Lubricate any moving parts with a water-soluble surgical instrument lubricant. The lubricant should be approved for use on medical devices and provided with data to ensure biocompatibility and compatibility with steam sterilization. Step 7: Packaging Place cleaned, dry devices into the specified locations within the cases provided, if applicable. Only legally marketed, and locally approved sterilization barriers (e.g. wraps, pouches or containers) should be used for packaging terminally sterilized devices, in compliance to the manufacturer s instructions. Step 8. Sterilization Steam (moist heat) sterilization shall be performed in a locally approved, pre-vacuum (forced air removal) cycle. The steam sterilizer should be validated to the requirements of any local standards and guidance such as EN 285 or AAMI/ANSI ST8. The steam sterilizer should be installed and maintained in compliance to manufacturer s instructions and local requirements. Ensure that the steam sterilizer cycle is chosen that is designed to remove air from porous or lumened device loads in accordance to manufacturer s instructions and does not exceed the criteria for sterilizer load. The following steam sterilization cycles are examples of validated cycles: Conditioning Phase Minimum Sterilization Exposure Time (minutes) Minimum Sterilization Exposure Temperature Dry Time Prevacuum 4 132 C (270 F) 30 minutes Prevacuum 3 134 C (274 F) 30 minutes 9 of 16

Extended steam exposure cycle can be used to meet local requirements such as 134 C (274 F) for 18 minutes. The efficiency of steam sterilizer drying can range considerable depending on the sterilizer design, loading, packaging and steam supply during the sterilization process. The user should employ verifiable methods (e.g. visual inspections) to confirm adequate drying. Extended drying within the sterilizer or in an external drying cabinet in accordance with manufacturer s instructions may be necessary. Do not exceed 140 C (284 F) during drying. Immediate-Use steam sterilization is only intended for individual instruments and should only be performed when approved by local policies. DePuy Synthes does not support immediate-use steam sterilization of instrument sets, cases or implants using this method. The following steam sterilization cycle is an example of a validated cycle for individual instruments only: Unwrapped instrument A minimum 3 (three) pulse pre-vacuum cycle 132 C (270 F) for 4 minutes Step 9: Storage Sterilized products should be stored in a dry, clean environment, protected from direct sunlight, pests, and extremes of temperature and humidity. Refer to sterilization wrap or rigid container manufacturers IFU for limits on sterile product storage time and storage requirements for temperature and humidity. ADDITIONAL INFORMATION Cleaning agent information: Examples of detergents that have been used during cleaning validations include Prolystica 2X Concentrate Enzymatic Cleaner, Prolystica 2X Neutral Detergent, Enzol, Endozime, Neodisher Medizym, Terg-A-Zyme, and NpH-Klenz. The chemical quality of the water used during reprocessing can impact device safety. Facilities should use the recommended water quality requirements for device reprocessing in accordance with local guidance (such as AAMI TIR 34, Water for the reprocessing of medical devices) and these instructions for use. These instructions for use have been validated in accordance with ISO 17664. It remains the responsibility of the facility to ensure that the processing is performed using equipment, materials and personnel at a designated area, and achieves the desired requirements. This includes validation and routine monitoring of the process. Likewise, any deviation by the processor from these recommendations should be evaluated for effectiveness and any potential adverse consequences. All personnel using these instructions should be qualified with documented expertise, competency and training. Users should be trained on healthcare facility policies and procedures along with current applicable guidelines and standards. 10 of 16

LIMITED WARRANTY AND DISCLAIMER PRODUCTS FROM DEPUY SYNTHES PRODUCTS, INC. ARE SOLD WITH A LIMITED WARRANTY TO THE ORIGINAL PURCHASER AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS. ANY OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE HEREBY DISCLAIMED. IF MORE THAN TWO YEARS HAVE ELAPSED BETWEEN THE DATE OF ISSUE/REVISION OF THIS INSERT AND THE DATE OF CONSULTATION, CONTACT DEPUY SYNTHES SPINE FOR CURRENT INFORMATION AT +1-800-365-6633 OR AT +1-508-880-8100. SYMBOL TRANSLATION LOT LOT NUMBER STERILE STERILE REF REF CATALOG NUMBER DO NOT RESTERILIZE SINGLE USE STERILE A Sterile medical device QTY QUANTITY T2 processed using aseptic technique SZ SIZE MADE IN MADE IN NTI NEURAL TISSUE INSTRUMENT IOM NEUROMONITORING INSTRUMENTS Federal (USA) law restricts this device to sale by or on the order of a physician T1 Lower Limit of temperature = T1 Upper Limit of temperature = T2 25 C STORE AT ROOM TEMPERATURE KEEP AWAY FROM SUNLIGHT ATTENTION. SEE INSTRUCTIONS FOR USE PACKAGE CONTAINS FLAMMABLE LIQUID DO NOT USE IF PACKAGE IS DAMAGED MSR MEASURING DEVICE STERILE R STERILIZATION BY IRRADIATION STERILE EO STERILIZATION BY ETHYLENE OXIDE LATEX FREE LATEX FREE NON STERILE NONSTERILE NONSTERILE MANUFACTURER DATE OF MANUFACTURE US REP US REPRESENTATIVE EC REP AUTHORIZED EUROPEAN REPRESENTATIVE DIST DISTRIBUTED BY XXXX-XX USE BY 11 of 16

A/T ACROFLEX /Ti ACROFLEX /Titanium A AI Aluminum A/P Al/PL Aluminum/Plastic B/R Ba/RADEL Barium/RADEL Ba/PEEK Barium Sulfate (BaSO4)/ PEEK Polymer CaP CALCIUM PHOSPHATE Calcium Phosphate CM CoCrMo Cobalt Chromium Molybdenum CMTC CoCrMo/Ti/CALCIUM PHOSPHATE Cobalt Chromium Molybdenum/Titanium/ Calcium Phosphate CoNiCrMo Cobalt Nickel Chromium Molybdenum F FOAM Foam HA Hydroxyapatite NiTi Ni/Ti Nickel/Titanium PL Plastic P/F PL/FOAM Plastic/Foam PY Polyester PEEK/C PEEK/CARBON FIBER COMPOSITE Polyether Ether Ketone/ Carbon Fiber Composite PEEK OPTIMA Polyether Ether Ketone P POLYMER Polymer P/CM PE/CoCrMo Polyethylene/Cobalt Chromium Molybdenum P/C POLYMER/CARBON FIBER COMPOSITE Polymer/ Carbon Fiber Composite Si/NITINOL Silicone/Nitinol S SS Stainless Steel S/A SS/Al Stainless Steel/Aluminum SBR SS/Ba/RADEL Stainless Steel/Barium/ RADEL S/P SS/PHENOLIC Stainless Steel/Phenolic S/PL SS/PL Stainless Steel/Plastic MATERIAL MATL SRSI SS/RADEL /SILICONE Stainless Steel/RADEL / Silicone SRSN SS/RADEL / SILICONE/Ti Al Nitride Stainless Steel/RADEL / Silicone/Titanium Aluminum Nitride SS/RADEL / SILICONE/Ti Nitride Stainless Steel/RADEL / Silicone/Titanium Nitride SRTA SS/RADEL /Ti Al Nitride Stainless Steel/RADEL / Titanium Aluminum Nitride STA SS/Ti Al Nitride Stainless Steel/ Titanium Aluminum Nitride S/U SS/ULTEM Stainless Steel/Ultem T Ti Titanium and its alloys S/R SS/RADEL Stainless Steel/RADEL R/T POLYOLEFIN RUBBER/Ti Polyolefin Rubber/Titanium T/A Ti/Al Titanium/Aluminum Ti/CoCrMo Titanium/Cobalt Chromium Molybdenum Ti/HA Titanium/Hydroxyapatite Ti/UHMWPE/HA Titanium/Ultra-High Molecular Weight Polyethylene/Hydroxyapatite SS/Ti Stainless Steel/Titanium SS/Al/SILICONE Stainless Steel/ Aluminum/Silicone SS/SILICA GLASS Stainless Steel/Silica Glass SS/SILICA GLASS/ PL/SILICONE Stainless Steel/Silica Glass/ Plastic /Silicone SS/SILICA GLASS/ RADEL /SILICONE Stainless Steel/Silica Glass/ RADEL /Silicone SS/SILICA GLASS/ SILICONE Stainless Steel/ Silica Glass/Silicone S/SI SS/SILICONE Stainless Steel/Silicone SS/WC/SILICONE Stainless Steel/Tungsten Carbide/Silicone W/C Tungsten Carbide 12 of 16

13 of 16

14 of 16

15 of 16

DePuy Spine, Inc. 325 Paramount Drive Raynham, MA 02767-0350 USA * Medos International SÀRL Chemin-Blanc 38 2400 Le Locle, Switzerland * * For recognized manufacturer, refer to product label. DePuy Spine, Inc. 325 Paramount Drive Raynham, MA 02767-0350 USA Phone: +1 (800) 451 2006 FAX: +1 (508) 828 3700 DePuy International, Ltd. St. Anthony s Road Leeds LS11 8DT England Phone: +44 113 270 0461 FAX: +44 113 272 4101 0902-90-044-EN Rev. J