Model D24-1S. Model D24-2S

Similar documents
GERMICIDAL ULTRAVIOLET IRRADIATORS

GERMICIDAL ULTRAVIOLET FIXTURES

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

ULTRAVIOLET INDIRECT AIR DISINFECTION

Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

Model RS72. Model RSCS280A. Model RSM2680

ULTRAVIOLET PORTABLE AREA SANITIZER

ULTRAVIOLET SANITARY CONDIT IONERS

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

Document No A9 Revised August Atlantic Ultraviolet Corporation

NO4G, NO4GS, NO6G, NO6GS

Owner s Manual. Installation, Operation & Maintenance. Models B B B3 RoHS

Document No A3 Revised February Atlantic Ultraviolet Corporation

Models 2B-SC, 3B-SC, 4B-SC, 4B-ASC, 5B-SC, 5B-ASC, 6B-SC, 6B-ASC. Models 2B-SC, 3B-SC. Models 6B-ASC. Installation, Operation & Maintenance

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

7-ASC / 8-ASC / 9-ASC

Owner s Manual. Installation, Operation & Maintenance. Model G48HO Remote Controlled Sanitizer

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

Document No C Revised January Atlantic Ultraviolet Corporation

Document No B1 February Atlantic Ultraviolet Corporation

Document No A1 Revised September Atlantic Ultraviolet Corporation

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

Document No B Revised June Atlantic Ultraviolet Corporation

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Ultraviolet Air Disinfection Equipment

S17A, S23A, S37C & S50C

ULTRAVIOLET WATER PURIFIERS

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions.

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

ULTRAVIOLET WATER PURIFIERS

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

UVC in the Operating Room.

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

PURPOSE OF THE PROCEDURE

PCO/UV N-Duct Model. Owner s Guide

GRU-V Air Purifier. Product Manual

UV measurements for medical applications using SiC photodiodes

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Intensive UV light means not a chance for germs!

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

Ballast MIN A

1020 Industrial Drive, Orlinda, TN fax

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

Add the Power of Indigo-Clean Disinfecting Technology to your Facility Lighting

Safety Manual Section 15 Radiation Safety

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

BREAKTHROUGH TECHNOLOGY THAT WON T. GE Lighting

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

LEARNING SPECIAL HAZARD DETECTION TYPES

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Flame Simulator User Manual. Publication Rev. A

A measured step forward

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

UV I UNIT030W / UV I UNIT055W

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

Liquid Storage Tank Conditioners

AMERICAN AIR & WATER, INC.

Appendix C IBC Safe Use of Biosafety Cabinets SOP

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

ULTRA-VIOLET STERILIZATION

Prepared for. MRC National Tuberculosis Research Programme. and the. South African Centre for Essential Community Services

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

PURION UV plants for disinfection

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Radiation and Laser Safety

Patient Compartment Light

USER MANUAL MODEL UV MINDER 3D V2.0. Part Number: Revision Level: A

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

UVP, Inc. Ultra-Violet Products Ltd., Unit W 11th Street, Upland, CA Trinity Hall Farm Estate, Nuffield Road

UVDI-360. Get the Facts Straight on UV Disinfection. Room Sanitizer

UV100E Ultraviolet Air Treatment System

ULTRAVIOLET WATER TREATMENT

EQUIPMENT OPERATION MANUAL. Loctite High Intensity Ultraviolet Source

Document No E1 Revised February Atlantic Ultraviolet Corporation

Loctite Zeta 7600 Ultraviolet Curing Conveyor Part Number EQUIPMENT Operation Manual

Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects?

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

254 Nanometer Germicidal UV Disinfection Systems

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Intense, cold and dry Efficient disinfection of packaging materials Premium UV solutions from Heraeus Noblelight

Model CWA200 Owner s Manual

PCR UV cabinets DNA/RNA

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

Section 3: Ultraviolet - UV

Ultraviolet PCR Cabinets and Workstations

INSECT REARING CHAMBERS

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

PCR UV cabinets DNA/RNA

WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Transcription:

Model D24-1S Model D24-2S

ABOUT US GERMICIDAL ULTRAVIOLET Since 1963, Atlantic Ultraviolet Corporation has pioneered the discovery and development of beneficial uses of ultraviolet energy. Over the years these efforts have led to the development of valuable, cost effective and environmentally sound techniques and products now known and respected throughout the world. The UV Application Specialists at Atlantic Ultraviolet Corporation assist customers in the selection of germicidal lamps and equipment. Their specialized knowledge is a valuable resource in formulating effective and cost-conscious ultraviolet solutions. Extensive inventories and a dedicated staff enable Atlantic Ultraviolet Corporation Ultraviolet is a unique and rapid method of disinfection utilizing germicidal ultraviolet lamps that produce shortwave radiation at 254 nanometers (nm) that is lethal to bacteria, virus and other microorganisms. An ever-growing range of industries and consumer applications have found ultraviolet to be the ideal solution for their air and surface treatment needs. Atlantic Ultraviolet Corporation equipment and systems are manufactured in the USA. to fulfill its commitment to provide fast deliveries and responsive customer service. Model D24-1S Shown with standard instant start germicidal lamps. Also available with cold cathode and high output instant start lamps. Model D24-2S 2

ADVANTAGES PRINCIPLE OF OPERATION Effective Virtually all microorganisms are susceptible to SaniLIGHT ultraviolet disinfection. Economical Fixtures require very little power to operate. Fast Disinfects both air and exposed surfaces in seconds. Ultraviolet Rays Model D24-1CC Easy Simple installation and maintenance. Automatic Continuous disinfection without special attention. Durable Polished Stainless Steel Type 304. Figure 1 - Circulated room air and any exposed surfaces are irradiated with direct germicidal ultraviolet rays. Shown with cold cathode germicidal lamps. Also available with high output, and instant start germicidal ultraviolet lamps. The SaniLIGHT Germicidal Ultraviolet Irradiator design has been carefully conceived to provide direct germicidal ultraviolet exposure for air or surface disinfection. The Stainless Steel fixture should be used in open, unoccupied space to disinfect and prevent areas and surfaces from microorganisms such as bacteria, mold, and virus. The treatment is very effective due to the long unobstructed path of the germicidal ultraviolet rays. The dosage, as it applies to ultraviolet disinfection, is a function of time, and the intensity, of ultraviolet radiation, to which the air or surfaces are exposed. Our UV Application Specialists would be happy to perform the necessary calculations to ensure the fixture selected is appropriate for your particular application. Versatile Numerous models available to handle various applications. Low Maintenance Routine cleaning and annual lamp replacement is required. SaniLIGHT Germicidal Ultraviolet Irradiators should be utilized during periods when the room is unoccupied or when occupants take appropriate protective measures. Model DHO24-1S with Lamp Guard Shown with high output germicidal lamp, Also available with cold cathode and instant start lamps. All SaniLIGHT Models are available with optional Lamp Guard. This wire form lamp guard helps protect lamps(s) from accidental breakage. (See page 8 for sample of Applications and page 10 for Optional Accessories.) ultraviolet.com buyultraviolet.com 3

SPECIAL FEATURES SaniLIGHT Instant Start Germicidal Ultraviolet Irradiator Utilize the SaniLIGHT Instant Start Germicidal Ultraviolet Irradiator for direct germicidal ultraviolet exposure for air and/or surface disinfection. Our UV Application Specialists would be happy to perform the necessary calculations to ensure the fixture selected is appropriate for your particular application. (See Applications below.) Surelite Electronic Ballast State-of-the-art electronic ballasts are designed specifically to operate ultraviolet lamps. Surelite Electronic Ballasts offer these advantages over conventional ballasts: deliver higher uv lamp output instant starting small and lightweight operate cooler for longer life versatile each operates a wide range of lamps save energy through higher efficiency provide silent operation Steadfast Lampholder Set includes a stationary and a spring-loaded, telescopic holder that holds a single pin lamp securely. The spring-loaded feature on one end facilitates convenient, quick and easy lamp changes. Stainless Steel Construction The unit is manufactured in Type 304 stainless steel for unparalleled strength, durability and an attractive finish. Model D24-1S (see page 10 for Optional Accessories) STER-L-RAY Instant Start Germicidal Lamp Lamp is instant starting and provides the utmost in quality, sustained output, and longevity. (See page 11 for information.) Wire Form Lamp Guard (optional) Wire form lamp guard helps protect lamp(s) from accidental breakage. Must be ordered at same time as fixture. APPLICATIONS* laboratories hospitals clinics maternity areas labor & delivery areas pathology labs kidney dialysis labs operating rooms methadone clinics burn centers TB clinics homeless shelters prisons and jails detention centers nursing homes universities schools veterinary clinics animal husbandry kennels food industry food processing dairy processing bakeries office buildings conference rooms clean rooms pharmaceutical mfg. electronic production cosmetic production manufacturing facilities morgues conveyor belt systems * Other Applications Possible. Contact our Ultraviolet Application Specialists. 4

INSTALLATION Figure 2 - SaniLIGHT Instant Start Germicidal Ultraviolet Irradiator D24-2S is shown above Proper placement of the SaniLIGHT Instant Start Germicidal Ultraviolet Irradiator is essential to ensure safe and effective operation. The location should have an appropriate power source, not be mounted under any source of moisture or condensation, and be easily accessible and allow enough clearance for routine cleaning or maintenance. SPECIFICATIONS SaniLIGHT INSTANT START GERMICIDAL ULTRAVIOLET IRRADIATORS Model Lamp (Quantity) Power Consumption Total Ultraviolet Output Unit Dimensions (Inches) Length Width Height Rated Lamp Life (Hours) D12-1S 05-1500-R (1) 12.0 Watts 3.1 Watts 13-1/4 5 3-3/4 10,000 D18-1S 05-1340-R (1) 22.0 Watts 5.8 Watts 19-1/4 5 3-3/4 10,000 D24-1S 05-1348-R (1) 30.7 Watts 8.5 Watts 25-1/4 5 3-3/4 10,000 D30-1S 05-1352-R (1) 38.4 Watts 11.2 Watts 31-1/4 5 3-3/4 10,000 D36-1S 05-1343-R (1) 42.9 Watts 13.8 Watts 37-1/4 5 3-3/4 10,000 D48-1S 05-1334-R (1) 66.0 Watts 19.3 Watts 49-1/4 5 3-3/4 10,000 D64-1S 05-1338A-R (1) 94.0 Watts 25.0 Watts 65-1/4 5 3-3/4 10,000 D12-2S 05-1500-R (2) 24.0 Watts 6.2 Watts 13-1/4 5-5/8 3-3/4 10,000 D18-2S 05-1340-R (2) 44.0 Watts 11.6 Watts 19-1/4 5-5/8 3-3/4 10,000 D24-2S 05-1348-R (2) 61.4 Watts 17.0 Watts 25-1/4 5-5/8 3-3/4 10,000 D30-2S 05-1352-R (2) 76.8 Watts 22.4 Watts 31-1/4 5-5/8 3-3/4 10,000 D36-2S 05-1343-R (2) 85.8 Watts 27.6 Watts 37-1/4 5-5/8 3-3/4 10,000 D48-2S 05-1334-R (2) 132.0 Watts 38.6 Watts 49-1/4 5-5/8 3-3/4 10,000 D64-2S 05-1338A-R (2) 188.0 Watts 50.0 Watts 65-1/4 5-5/8 3-3/4 10,000 Total power consumption including ballast loss. Ultraviolet Output at 254 nanometers at 100 hours and 80 degrees F (approximate). 120 Volts 50/60 Hz and 230 Volts 50/60 Hz units are standard - specify when ordering. Units are available in various voltages - Consult factory with specific power requirements. Models with other lamp quantities and configurations available. Consult factory with specific requirements. ultraviolet.com buyultraviolet.com 5

SPECIAL FEATURES SaniLIGHT Cold Cathode Germicidal Ultraviolet Irradiator Utilize the SaniLIGHT Cold Cathode Germicidal Ultraviolet Irradiator for direct germicidal ultraviolet exposure for air and/or surface disinfection. Our UV Application Specialists would be happy to perform the necessary calculations to ensure the fixture selected is appropriate for your particular application. (See Applications below.) Surelite Electronic Ballast State-of-the-art electronic ballasts are designed specifically to operate ultraviolet lamps. Surelite Electronic Ballasts offer these advantages over conventional ballasts: deliver higher uv lamp output instant starting small and lightweight operate cooler for longer life versatile each operates a wide range of lamps save energy through higher efficiency provide silent operation Steadfast Lampholder Set includes a stationary and a spring-loaded, telescopic holder that holds a single pin lamp securely. The spring-loaded feature on one end facilitates convenient, quick and easy lamp changes. Stainless Steel Construction The unit is manufactured in Type 304 stainless steel for unparalleled strength, durability and an attractive finish. Model D24-1CC (see page 10 for Optional Accessories) STER-L-RAY Cold Cathode Germicidal Lamp Lamp is instant starting, utilizing large cylindrical cathodes instead of tungsten filaments. Cold Cathode lamps are recommended for applications where temperature is colder than standard room temperature, for example, walk-in refrigerators and holding rooms. (See page 11 for information.) Wire Form Lamp Guard (optional) Wire form lamp guard helps protect lamp(s) from accidental breakage. Must be ordered at same time as fixture. APPLICATIONS* Best used for applications where frequent starting and stopping is required and where unit must be operated in cooler temperatures. cool rooms meat lockers, refrigeration units freezers holding rooms * Other Applications Possible. Contact our Ultraviolet Application Specialists. 6

INSTALLATION Figure 3 - SaniLIGHT Cold Cathode Germicidal Ultraviolet Irradiator D24-2CC is shown above Proper placement of the SaniLIGHT Cold Cathode Germicidal Ultraviolet Irradiator is essential to ensure safe and effective operation. The location should have an appropriate power source, not be mounted under any source of moisture or condensation, and be easily accessible and allow enough clearance for routine cleaning or maintenance. Cold Cathode Lamps are recommended for walk-in refrigerators and holding rooms and are also employed in applications where frequent starting is a requirement. SPECIFICATIONS SaniLIGHT COLD CATHODE GERMICIDAL ULTRAVIOLET IRRADIATORS Model Lamp (Quantity) Power Consumption Total Ultraviolet Output Unit Dimensions (Inches) Length Width Height Rated Lamp Life (Hours) D12-1CC 05-0052A (1) 18.8 Watts 1.4 Watts 13-1/4 5 3-3/4 20,000 D18-1CC 05-0040-R (1) 26.3 Watts 3.2 Watts 19-1/4 5 3-3/4 20,000 D24-1CC 05-1118-R (1) 28.8 Watts 5.0 Watts 25-1/4 5 3-3/4 20,000 D36-1CC 05-0044-R (1) 35.0 Watts 8.5 Watts 37-1/4 5 3-3/4 20,000 D48-1CC 05-0042-R (1) 42.5 Watts 11.2 Watts 49-1/4 5 3-3/4 20,000 D18-2CC 05-0040-R (2) 52.6 Watts 6.4 Watts 19-1/4 5-5/8 3-3/4 20,000 D24-2CC 05-1118-R (2) 57.6 Watts 10.0 Watts 25-1/4 5-5/8 3-3/4 20,000 D36-2CC 05-0044-R (2) 70.0 Watts 17.0 Watts 37-1/4 5-5/8 3-3/4 20,000 D48-2CC 05-0042-R (2) 85.0 Watts 22.4 Watts 49-1/4 5-5/8 3-3/4 20,000 Total power consumption including ballast loss. Ultraviolet Output at 254 nanometers at 100 hours and 80 degrees F (approximate). 120 Volts 50/60 Hz and 230 Volts 50/60 Hz units are standard - specify when ordering. Units are available in various voltages - Consult factory with specific power requirements. Models with other lamp quantities and configurations available. Consult factory with specific requirements. ultraviolet.com buyultraviolet.com 7

SPECIAL FEATURES SaniLIGHT High Output Germicidal Ultraviolet Irradiator Utilize the SaniLIGHT High Output Germicidal Ultraviolet Irradiator for direct germicidal ultraviolet exposure for air and/or surface disinfection. Our UV Application Specialists would be happy to perform the necessary calculations to ensure the fixture selected is appropriate for your particular application. (See Applications below.) Surelite Electronic Ballast State-of-the-art electronic ballasts are designed specifically to operate ultraviolet lamps. Surelite Electronic Ballasts offer these advantages over conventional ballasts: deliver higher uv lamp output instant starting small and lightweight operate cooler for longer life versatile each operates a wide range of lamps save energy through higher efficiency provide silent operation Steadfast Lampholder Set includes a stationary and a spring-loaded, telescopic holder that holds a single pin lamp securely. The spring-loaded feature on one end facilitates convenient, quick and easy lamp changes. Stainless Steel Construction The unit is manufactured in Type 304 stainless steel for unparalleled strength, durability and an attractive finish. Model DHO24-1S (see page 10 for Optional Accessories) STER-L-RAY High Output Germicidal Lamp Lamp is instant starting and provides the utmost in quality, sustained output, and longevity. Yields more UV watts than standard UV-C lamps of the same length. (See page 11 for information.) Wire Form Lamp Guard (optional) Wire form lamp guard helps protect lamp(s) from accidental breakage. Must be ordered at same time as fixture. APPLICATIONS* laboratories hospitals clinics maternity areas labor & delivery areas pathology labs kidney dialysis labs operating rooms methadone clinics burn centers TB clinics homeless shelters prisons and jails detention centers nursing homes universities schools veterinary clinics animal husbandry kennels food industry food processing dairy processing bakeries office buildings conference rooms clean rooms pharmaceutical mfg. electronic production cosmetic production manufacturing facilities morgues conveyor belt systems * Other Applications Possible. Contact our Ultraviolet Application Specialists. 8

INSTALLATION Figure 4 - SaniLIGHT High Output Germicidal Ultraviolet Irradiator DHO24-2S is shown above Proper placement of SaniLIGHT High Output Germicidal Ultraviolet Irradiator is essential to ensure safe and effective operation. The location should have an appropriate power source, not be mounted under any source of moisture or condensation, and be easily accessible and allow enough clearance for routine cleaning or maintenance. SPECIFICATIONS SaniLIGHT HIGH OUTPUT GERMICIDAL ULTRAVIOLET IRRADIATORS Model Lamp (Quantity) Power Consumption Total Ultraviolet Output Unit Dimensions (Inches) Length Width Height Rated Lamp Life (Hours) DHO18-1S 05-0687 (1) 58.0 Watts 11.5 Watts 19-1/4 5 3-3/4 13,000 DHO24-1S 05-0686 (1) 73.7 Watts 17.0 Watts 25-1/4 5 3-3/4 13,000 DHO30-1S 05-0685 (1) 92.2 Watts 23.0 Watts 31-1/4 5 3-3/4 13,000 DHO36-1S 05-1060-R (1) 108.0 Watts 28.0 Watts 37-1/4 5 3-3/4 13,000 DHO48-1S 05-0576 (1) 158.4 Watts 40.0 Watts 49-1/4 5 3-3/4 13,000 DHO64-1S 05-0690 (1) 193.0 Watts 54.0 Watts 65-1/4 5 3-3/4 13,000 DHO18-2S 05-0687 (2) 116.0 Watts 23.0 Watts 19-1/4 5-5/8 3-3/4 13,000 DHO24-2S 05-0686 (2) 147.4 Watts 34.0 Watts 25-1/4 5-5/8 3-3/4 13,000 DHO30-2S 05-0685 (2) 184.3 Watts 46.0 Watts 31-1/4 5-5/8 3-3/4 13,000 DHO36-2S 05-1060-R (2) 216.0 Watts 56.0 Watts 37-1/4 5-5/8 3-3/4 13,000 DHO48-2S 05-0576 (2) 316.8 Watts 80.0 Watts 49-1/4 5-5/8 3-3/4 13,000 DHO64-2S 05-0690 (2) 386.0 Watts 108.0 Watts 65-1/4 5-5/8 3-3/4 13,000 Total power consumption including ballast loss. Ultraviolet Output at 254 nanometers at 100 hours and 80 degrees F (approximate). 120 Volts 50/60 Hz and 230 Volts 50/60 Hz units are standard - specify when ordering. Units are available in various voltages - Consult factory with specific power requirements. Models with other lamp quantities and configurations available. Consult factory with specific requirements. ultraviolet.com buyultraviolet.com 9

OPTIONAL ACCESSORIES SENTINEL Remote Lamp Indicator * The SENTINEL Remote Lamp Indicator monitors lamp operation of one, two, or four lamp ultraviolet fixtures and is available with a 25, 50 or 100 foot cable. (*Available for All SaniLIGHT fixtures at the time of purchase. SENTINEL output connector needs to be installed for easy plug-in and operation.) ArmorLite Safety Shield Protective coating applied to STER-L-RAY Germicidal Lamps ensures protection for employees, products and work environments by eliminating the dangers associated with fragments of broken lamps and mercury contamination. (Lamp on right has ArmorLite coating. Available for lamps used in ALL SaniLIGHT fixtures.) Zenith Ultraviolet Meter A sensitive, hand-held, ultraviolet meter that can be used to: Survey installations to ensure that the germicidal ultraviolet radiant exposure, of occupants within the treated area, is within acceptable limits. The Zenith Ultraviolet Meter provides accurate and easy-to-read levels of intensity that may be interpreted by anyone not just engineers. Check the intensity of aging ultraviolet lamps. Wire Form Lamp Guard * Wire form lamp guard helps protect lamp(s) from accidental breakage. (*Available for All SaniLIGHT fixtures at the time of purchase. Wire Form Lamp Guard needs to be installed in factory.) Promate Face Shield Lightweight visor with adjustable headgear provides eye and face protection from germicidal ultaviolet rays. OPERATING CHARACTERISTICS Relative Spectral Energy Distribution (Typical) 100 Germicidal Effectiveness As Related to Wavelength 100 INTENSITY 80 60 40 20 RELATIVE EFFECTIVENESS 80 60 40 20 0 0 100 200 300 400 500 600 200 225 250 275 300 WAVELENGTH (NANOMETERS) WAVELENGTH (NANOMETERS) 10

GENUINE STER-L-RAY GERMICIDAL LAMPS STER-L-RAY Germicidal Lamps are shortwave, low pressure mercury vapor discharge tubes that produce ultraviolet wavelengths lethal to microorganisms. Approximately 95% of the ultraviolet energy emitted from STER-L-RAY Germicidal Lamps is at the mercury resonance line of 254 nanometers, the region of germicidal effectiveness most destructive to bacteria, mold and virus. STER-L-RAY Instant Start Germicidal Lamps utilize tungsten filaments. Lamp life is governed by the life of the filaments and is affected by the frequency of starting. STER-L-RAY lamps are well suited for a variety of air and surface applications. STER-L-RAY Cold Cathode Germicidal Lamps are instant start lamps and utilize large cylindrical cathodes instead of tungsten filaments. STER-L-RAY Cold Cathode Germicidal Lamps possess favorable operating characteristics; their life is significantly longer than that of other lamp types. They are not adversely affected by the frequency of starting and they maintain a high ultraviolet output throughout their life, even at reduced temperatures. Cold cathode germicidal lamps are widely used in walk-in refrigerators and holding rooms, and are also employed in applications where frequent starting is a requirement. STER-L-RAY High Output (HO) Instant Start Germicidal Lamps are similar in size and shape to conventional germicidal lamps but are capable of operating at higher input power and current. The HO lamps yield more UV watts than standard UV-C lamps of the same length. Lamp life is governed by the life of the filaments and is affected by the frequency of starting. STER-L-RAY High Output Lamps are well suited for a variety of air and surface applications which require high output ultraviolet intensity. STER-L-RAY and the STER-L-RAY logo are trademarks of Atlantic Ultraviolet Corporation. CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable face shield, gloves, and protective clothing. ULTRAVIOLET DOSAGE Germicidal lamps provide effective protection against microorganisms. A small cross-section is shown below. ORGANISM ALTERNATE NAME TYPE DISEASE DOSE* Corynebacterium diphtheriae C. diphtheriae Bacteria Diptheria 6,500 Legionella pneumophila L. pneumophila Bacteria Legionnaire s Disease 2,700 Mycobacterium tuberculosis M. tuberculosis Bacteria Tuberculosis (TB) 10,000 Pseudomonas aeruginosa P. aeruginosa Bacteria 3,900 Serratia Marcescens S. marcescens Bacteria 6,160 Staphlylococcus aureus S. aureus Bacteria 6,600 Staphlylococcus epidermidis S. epidermidis Bacteria 5,800 Adeno Virus Type III Virus 4,500 Coxsackie A2 Virus 6,300 Influenza Virus Flu 3,400 * Nominal Ultraviolet dosage (µwsec/cm2) necessary to inactivate better than 99% of specific microorganism. Consult factory for more complete listing. ultraviolet.com buyultraviolet.com 11

The Standard of Excellence In Ultraviolet Manufacturers / Engineers / Sales / Service Germicidal Ultraviolet - Equipment & Lamps 375 Marcus Boulevard Hauppauge, NY 11788 631.273.0500 Fax: 631.273.0771 E-mail: info@ultraviolet.com ultraviolet.com buyultraviolet.com The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation and are believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein. Specifications and information are subject to change without notice. Document No. 98-1093 October 2017 2017 by Atlantic Ultraviolet Corporation MADE IN THE USA