More Precision. indusensor // Linear inductive displacement sensors

Similar documents
More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors

More Precision. indusensor // Linear inductive displacement sensors

More Precision. thicknesssensor // The sensor for precise thickness measurements

More Precision. eddyncdt // Eddy current sensors for displacement and position

More Precision. indusensor // Linear inductive displacement sensors

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

More Precision. thermometer // Non-contact IR temperature sensors

More Precision. Innovative Sensor Technologies. Displacement Distance Position. Dimension Temperature Colour

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

for relative humidity and temperature

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

for relative humidity and temperature

for relative humidity and temperature with calibration certificates

M5200 Industrial Pressure Transducer

U5300 Industrial Pressure Transducer

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

Datasheet: K-22 LO Sensor

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Welcome to Micro-Epsilon

M7100 Pressure Transducer

Level gauges Series LS Level indicator, switch and transmitter for liquids

Duct Air Quality Sensors

Lamp Supply (Recommended)

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

QPM21 Series Duct CO 2 and Air Quality Sensors

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

More Precision. thermometer // Non-contact infrared temperature sensors

S304 and S305 Dust Emission Monitors. User Manual. Distributor

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

Electronic Pressure Digest. Pressure and Temperature Transmitters

SELECTION TABLE x 42 x x 48 x x 50 x M12 x 70. Housing material. Typ. operating range/scanning range [mm]

Series 45 Pumps Fan Drive Control (FDC)

Duct Temperature Sensors

VIBRA-series: VIBRA, VIBRA +

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

UV - flame detector dual fuel burners for intermittent burner operations

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Air. Pressure. Motion. nnnnnnnn

M5800 Pressure Transducer with Rotatable Display

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

M5800 Pressure Transducer with Rotatable Display

MAJOR CONCERN on your GENERATORS?

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Advantages / Characteristics

SOCH AUTOMATION AND POWER SOLUTION

Process Alarm Module RTA 421

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Laser Distance Sensor Type M Analog-Output

Monitored Pneumatic Valves On Series Ported Manifold

Oxygen Sensing Solutions

MODEL 4000A & 4001A ACCELEROMETER

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Power Supply Display Module PSDM. Installation and Operation Manual

Topscan G3 Presence detector for automatic doors

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

½ Monitored Pneumatic Valves On Series Ported Manifold

Key Features. General Description

aquaconcept Cold water

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

OEM Sensors for HVAC manufacturers Heat recovery Chiller

LC1350 Level Controller

Economically Productive Universal applicable

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Dissolved Oxygen Measurement liquisys M COM 223 / 253

SECTION Fluorescent Dissolved Oxygen Measuring System

Circular Robotic Connectors

RS Pro Infrared Temperature Sensor

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

U5700 Submersible Liquid Level Pressure Transducer

02/11/2015

Room Temperature Sensors

OPTISENS TUR 2000 Technical Datasheet

PRODUCT SELECTOR GUIDE

Knürr RMS Compact II. Knürr RMS Compact II 2.81

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

PROFIBUS-PA Display RID 261 PROFIBUS-PA

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

Industry leading solutions

Model 144H. Product Data Sheet , Rev DB February Content

Display Units Pages 443, 447. Measuring Units Pages 444 to 446. Benchtop Laser Scan Micrometer Page. Accessories Pages 450, 451

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Sensors and Switches in Commercial Traction Elevators

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Transcription:

More Precision indusensor // Linear inductive displacement sensors

14 Long-stroke sensors for hydraulics & pneumatics indusensor EDS - Measurement ranges 75... 630mm - Linearity ±0.3% FSO - Integrated microelectronics - High pressure resistance - Oil resistant and maintenance-free - Short offset ranges The sensor elements of the EDS series are protected by a pressure resistant stainless steel housing. The sensor electronics and signal conditioning are completely integrated in a sensor flange. As a target an aluminium sleeve is used which is integrated into the piston rod and is passed without making contact and wearfree over the sensor rod. Integration in a hydraulic cylinder Due to the use of the eddy current principle, no permanent magnets need to be mounted inside the cylinder. Typical applications Long-stroke sensors in the EDS series are designed for industrial use in hydraulic and pneumatic cylinders for the displacement and position measurement of pistons or valves, e.g. for the measurement of displacement, distance, position, gap deflection movement, stroke filling level, immersion depth, spring travel Due to the rugged design of the long-stroke sensors of the EDS series, these sensor systems have proven themselves, not only through the integration in hydraulic and pneumatic cylinders, but especially under harsh industrial conditions. EDS series: integration in a hydraulic cylinder

15 Model EDS-75 EDS-100 EDS-160 EDS-200 EDS-250 EDS-300 EDS-400 EDS-500 EDS-630 Connection S S, F S, F S S, F S, F S, F S S, F Measuring range 75mm 100mm 160mm 200mm 250mm 300mm 400mm 500mm 630mm Linearity 0.3% FSO 0.23mm 0.3mm 0.48mm 0.6mm 0.75mm 0.9mm 1.2mm 1.5mm 1.89mm Resolution 0.05% FSO 0.038mm 0.05mm 0.08mm 0.1mm 0.125mm 0.15mm 0.2mm 0.25mm 0.315mm Temperature range -40 C... +85 C Temperature stability ±200ppm / C Frequency response (-3 db) Output Output load Power supply Current consumption Connector Pressure resistance model S model F 150Hz 4-20mA 500Ω 18-30VDC max. 40mA 7-pin connector (sensor cable as an option) options radial or axial output 5-pin radial bayonet-connector with mating plug 450bar (sensor rod, flange) Protection class IP 67 Electromagnetic compatibility (EMC) Shock 1) Vibration EN 61326-1:2006 (spurious emission) EN 61326-2-3:2006 (immunity to interference) 40g, 3000 shocks / axis 100g radial, 300g axial 5Hz... 44Hz ±2.5mm 44Hz... 500Hz ±23g Material V4A-Steel 1.4571 1) FSO = Full Scale Output Half sinusoid 6 ms Model S 8 (16 EDS-400/EDS-630) L 36.5 a Model F 56 35 Ø80 Connector radial axial connector Ø34 Ø30 32.5 Ø21f7 Alu tube Sensor rod l D d 76 Ø42 6 mounting holes ø9mm on pitch circle ø63mm Article EDS- 300- S- SA7- I Electrical output SR = connector, radial (model F) SA7 = connector, axial (model S) Models: S = compact design with alu cap F = flange housing with mounting holes Measuring range in mm Meas. range Sensor rod Alu tube Offset L D l d a 75 110 10 110 16 15 100 140 10 140 16 20 160 200 10 200 16 20 200 240 10 240 16 20 250 290 10 290 16 20 300 340 10 340 16 20 400 450 12 450 (S) 460 (F) 18 (S) 26 (F) 25 500 550 12 550 18 25 630 680 12 680 (S) 690 (F) 18 (S) 26 (F) 25

18 Accessories LDR, EDS, LVDT series General accessories 2960031 MC25D digital micrometer calibration fixture 2420062 PS2020 power supply on DIN rail, input 100-240VAC, output 24VDC / 2.5A 2984026 certificate function and linearity inspection certificate incl. protocol with listed measurement data of the linearity inspection and documentation Accessories LDR series Connection cable 0157047 C7210-5/3 sensor cable, 5m, with cable connector 0157048 C7210/90-5/3 sensor cable, 5m, with 90 cable connector Linearity inspection certificate Supply cable 2901087 PC710-6/4 supply/output cable, 6m Plunger 0800136 LDR-10 plunger 0800137 LDR-25 plunger 0800138 LDR-50 plunger Accessories EDS series Service 2985001 Function and linearity inspection for EDS series incl. pressure inspection and documentation without recalibration Connection cable 0157043 C703-5 VIP/LVP/EDS 7-pin connection cable for S series, 5m 2902084 C703-5/U VIP/LVP/EDS 7-pin connection cable for S series, 5m for voltage output 1-5V 0157050 C703/90-5 VIP/LVP/EDS 7-pin connection cable for S series, 5m with 90 cable connector 2901143 C705-5 VIP-/LVP-/EDS -pin connection cable for F series, 5m 2901160 C705-15 VIP-/LVP-/EDS -pin connection cable for F series, 15m

High performance sensors made by Micro-Epsilon Sensors and systems for displacement and position Sensors and measurement devices for non-contact temperature measurement 2D/3D profile sensors (laser scanner) Optical micrometers, fiber optic sensors and fiber optics Color recognition sensors, LED analyzers and color online spectrometer Measurement and inspection systems Modifications reserved / Y9766177-A021038GKE MICRO-EPSILON USA 8120 Brownleigh Dr. Raleigh, NC 27617 / USA Phone +1/919/787-9707 Fax +1/919/787-9706 me-usa@micro-epsilon.com www.micro-epsilon.com