VHP M100 BIODECONTAMINATION SYSTEM

Similar documents
VHP ARD BIODECONTAMINATION SYSTEM

VHP M100 Biodecontamination Systems: Closed Loop

VHP M100 Biodecontamination Systems

VHP ARD Mobile Biodecontamination System

AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (For Use Outside U.S.A. Only)

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

BASIL 6700 TUNNEL CAGE WASHER

The Reliance 400/500 Glassware Washers

RELIANCE 680PG PHARMACEUTICAL GRADE WASHER

RELIANCE 400 LABORATORY GLASSWARE WASHER

RELIANCE 580 PHARMACEUTICAL GRADE WASHER

VS LD series vertical steam sterilizers

Introducing The Reliance 200 and 250 Glassware Washing Systems.

HARMONY LED385 EXAMINATION LIGHTING SYSTEM

BASIL 6000 TUNNEL CAGE WASHER

HAMO T-420 PHARMACEUTICAL GRADE WASHER SIEMENS PC CONTROL

Analyze IT. Process Gas Chromatograph. PGC2000 Series

VISION 1321/1327 CART AND UTENSIL WASHER/DISINFECTOR

cgmp STEAM STERILIZERS

Thermo Scientific Model 1160 Principle of Operation

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

Dual Tower Heat Reactivated Desiccant Air Dryer

V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

00% 100%3HealthCare 00%

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

AS950 PORTABLE SAMPLERS

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

An overview of sterilizer equipment standards current and planned. Richard Bancroft Science & Technical Director STERIS

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

BASIL 9502 CAGE AND RACK WASHER

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

AS950 REFRIGERATED SAMPLERS

SULLAIR DESICCANT DRYERS

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

VWR symphony CO 2 INCUBATORS

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

AIR TO AIR HEAT EXCHANGERS

P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T

Benchtop CO 2 Incubator. the Oasis 6400 series

Environmental Health and Safety Biological Safety Program Guidance Document

Control Operating Costs. Gain Process Efficiency.

900MAX PORTABLE SAMPLERS

Mini Spray Dryer B-290 Technical data sheet

LAB DIVISION. WASHING & DRYING cglp Process Equipment for Research and Microbiological Laboratories

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Conveying Controls. Conveying, Drying and Blending Systems. Technical Service Available 24/7! D C F. For Extrusion, Injection and Blow Molding Plants

AQUAWING OZONE SYSTEM SPECIFICATION FOR PCI RETREAT LAUNDRY

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

IBC Wash: Critical Cleaning Solution for IBCs, Totes and Tablet Bins.

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

STEAM STERILIZER SERIE S1000 (RBE)

V LPM Desiccant Air Dryer Installation and Operation Manual

Externally Heated Desiccant Air Dryer RP Series

Undercounter Refrigerator Operation Manual i.series and Horizon Series

RELIANCE 444 SINGLE-CHAMBER WASHER/DISINFECTOR

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

Clean, Dry Air System

AMSCO CENTURY MEDIUM STEAM STERILIZER 26 X 26" (SCIENTIFIC)

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

Rotavapor R-220 Pro Technical data sheet

Mobile Hop Dryer SARE Project FNC

FLASH PAK STERILIZATION CONTAINER SYSTEM

Maxline 2 Thermal Imaging Solutions for Manufacturing

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

AUTOMATIC STERILIZERS

With the world-renowned SIGMA PROFILE

Open the Door to Increased Productivity and Cost Efficiency

CLEAN, DRY COMPRESSED AIR

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

Drying of Difficult Resins

BAC 4000a BAC 5000yf

Pharmaceutical washing-systems

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

ASM 340. Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

SECTION Free/Available Chlorine Analysis System

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

EC3-X33 Stand-alone Superheat Controller Technical Data

Photo courtesy of U.S. Navy. ARID-Dry. Restoration and Construction Drying Equipment Mobile Desiccant Dehumidifiers Temporary Humidity Control

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Nano Spray Dryer B-90 HP Technical data sheet

Desiccant Dehumidifier

G 7825 Laboratory Glassware Washer. Compact Design, High Throughput

Model WP-32 Pouch Machine

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS

Single Tower Heat Reactivated Desiccant Air Dryer

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

When reliability is vital. Alemite Carbon Shield TM Systems deliver

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

EXTERNALLY HEATED DESICCANT AIR DRYERS. DHP Series

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Fedegari Aseptic Technology Integration: Case Study. Sergio Mauri, Director, Global Integrated Projects

Transcription:

VHP M100 BIODECONTAMINATION SYSTEM APPLICATION The VHP M100 Small Volume Biodecontamination System is a hydrogen peroxide vapor generator for biodecontamination* of clean, dry, sealed Enclosures** used in medical and biological laboratories. The VHP M100 Biodecontamination System is equally efficient in either closed- or open-loop configurations. * When using VHP Biodecontamination Systems with Vaprox Hydrogen Peroxide Sterilant in the United States, the term biodecontamination referred to in this document is defined as sterilization of exposed porous and non-porous surfaces in a precleaned, dry, sealed Enclosure. Any reference to biodecontamination as it relates to the use of this equipment in the United States does not impart additional claims of effectiveness beyond that approved in the EPA registered labeling of Vaprox Hydrogen Peroxide Sterilant. ** Enclosure must be leak tested according to manufacturer's recommendations. DESCRIPTION The VHP M100 Biodecontamination System is designed for biodecontamination of clean, dry surfaces in and permanent mounting to sealed Enclosures. The Biodecontamination System can operate independently as a stand-alone machine but may also be operated through interface to external equipment. This interface provides many options, including data communication via communication protocols as well as discrete I/O interfacing. In most cases, this interface is used to start Biodecontamination Cycles, abort cycles and monitor the Biodecontamination System status. The VHP M100 Biodecontamination Unit is only to be operated by trained and certified applicators who have successfully completed the STERIS Training and Certification Course for applicators of Vaprox Hydrogen Peroxide Sterilant. Certification must be active and in force for all applicators of Vaprox Hydrogen Peroxide Sterilant. Recertification is required every three years. (Typical only - some details may vary.) To minimize exposure to the liquid hydrogen peroxide during handling, the system uses specially designed disposable cartridges containing approximately 950 ml or bulk containers containing approximately 5 gal (19 L) of Vaprox Hydrogen Peroxide Sterilant. Units are available for operation on 120 or 230 Volts, 50/60 Hz, Single phase electrical service. STANDARDS The VHP M100 Biodecontamination System meets the applicable requirements of the following standards: Underwriters Laboratories (UL): 61010-1. Canadian Standards Association (CSA) Standard C22.2 No. 61010.1. EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC. Low Voltage Directive 73/23/EEC, 93/68/EEC. The Selections Checked Below Apply To This Equipment VOLTAGES 120 Vac, 50/60 Hz 230 Vac, 50/60 Hz ACCESSORIES Reusable Desiccant Cartridge(s) and Regenerator 120 Vac, 50/60 Hz 230 Vac, 50/60 Hz Disposable Desiccant Cartridges and Adapter Mobile Cart Munters Dehumidifier MG-90 Munters Dehumidifier HC-300 LANGUAGE OPTIONS English French German Spanish Italian Dutch OPTIONS Closed-Loop Open-Loop CONTROLS Siemens Allen-Bradley* OPEN-LOOP STERILANT DELIVERY 950 ml Cartridge Bulk Container * English and French only. Item Location(s) SD776 (07/01/08)

CYCLE DESCRIPTION (Typical) STERIS s VHP Technology produces hydrogen peroxide vapor, a broad spectrum antimicrobial. The biodecontamination process is a dry process resulting in NO condensation of the active ingredient onto surfaces. This non-condensation feature provides the additional benefit of a wide range of material compatibility. The VHP M100 Biodecontamination Unit delivery and control systems provide low-temperature biodecontamination methods for many enclosed areas. In practice, an aqueous solution of 35% H 2 O 2 (Vaprox Hydrogen Peroxide Sterilant) is flash vaporized. A heated air stream carries the vapor into the enclosed space requiring biodecontamination. With the VHP M100 Biodecontamination Unit operating as a closed-loop system, air and the VHP antimicrobial are drawn out of the enclosed space and pass through a catalytic converter degrading the VHP antimicrobial into oxygen and water vapor. The air stream then recharges with fresh VHP antimicrobial vapor within the VHP Biodecontamination Unit and returns to the Enclosure. NOTE: The VHP process can also be operated in an open-loop configuration. Check local regulations regarding environmental hydrogen peroxide discharge. While operating in a closed-loop configuration (see illustration), the biodecontamination cycle consists of four phases (see illustration): Dehumidification Dry, HEPA-filtered (High Efficiency Particulate Air) air is circulated to reduce humidity to a predetermined level in the 10-60% relative humidity range. This permits the necessary target Vaprox Hydrogen Peroxide Sterilant vapor concentration to be maintained below saturation (dew point) levels during the Conditioning and Biodecontamination phases. The return air passes through the dryer and then is heated to serve as the carrier for the VHP antimicrobial. The internal HEPA filters prevent contamination of internal machine components and prevent recontamination of the Enclosure. NOTE: Time to reach the targeted humidity corresponds with the initial humidity, temperature and volume of the Enclosure. Conditioning The flow of dry, HEPA-filtered air continues while Vaprox Hydrogen Peroxide Sterilant vapor is injected into the air stream just before it leaves the unit. The Vaprox Sterilant injection rate is controllable in the 1.0 to 12.0 grams per minute range (for openloop, 1.0 to 25.0 grams per minute range). The Conditioning phase facilitates reaching the target biodecontamination concentration faster in larger volume sealed Enclosure applications. Conditioning time is affected by sterilant injection rate, Enclosure volume, Enclosure contents and temperature. Biodecontamination The target VHP antimicrobial concentration is maintained for a specific period of time throughout the Enclosure. Aeration Vaprox Hydrogen Peroxide Sterilant vapor injection is stopped and the recirculating flow of dry, HEPA-filtered air continues through the catalytic converter to reduce the H 2 O 2 vapor concentration within the Enclosure. ACCESSORIES To accomplish the reduction of relative humidity in the Enclosure, either a reusable or disposable desiccant system must be employed. Reusable Desiccant Cartridge(s) and Regenerator - The reusable cartridge containing desiccant is constructed of aluminum and is easily installed in the VHP M100 Biodecontamination System. Following use, a prompt notifies the operator that it is time to remove the cartridge and install it in the regenerator to refresh the desiccant. An indicator on the regenerator signals the user that the cartridge is ready for reuse. Inlet Sterilant Hose Injection Injection Pump Vaprox Vaprox Cartridge Hydrogen Peroxide Sterilant Sterilant Vapor * Vaporizer Pre-Heater Enclosure Catalytic Converter * Optional * Optional Sterilant Sterilant Circulation Circulation Blower Blower Blower Dryer Typical Closed-Loop Process Diagram 2

Dehumidification Dehumidification Dehumidification Condition Conditioni Biodecontamination Biodecontamination Decontamination Aeration Aeration Aeration water Water hydrogen Hydrogen peroxide Peroxide Peroxide Concentration time Time Typical VHP M100 Biodecontamination System Four Cycle Disposable Desiccant Cartridges and Adaptor - The disposable cartridge containing desiccant is constructed of plastic and is easily installed in the VHP M100 Biodecontamination System using a stainless-steel adaptor. Following use, a prompt notifies the operator that it is time to discard and replace the cartridge. NOTE: Reusable or disposable desiccant cartridges are not available on the open-loop configured VHP M100 Biodecontamination Units. Munters Model MG-90 CargoCaire Dehumidifier - A compact, low profile design, desiccant dehumidifier is an accessory for open-loop moderate volume configurations to aid in moisture removal. This non-cycling sorption dehumidifier with single desiccant rotary structure operates at 53 scfm (90 m 3 /h). Munters Model HC-300 CargoCaire Dehumidifier - A compact, low profile design, desiccant dehumidifier is an accessory for open-loop large volume configurations to aid in moisture removal. This non-cycling sorption dehumidifier with single desiccant rotary structure has nominal moisture removal of 9.1 lb/h at 75 F (4.1 kg/h at 24 C), 50% Relative Humidity at 300 scfm (510 m 3 /h). FEATURES Operator Interface. Two are available. Siemens Simatic TP277 - The touch panel is a backlit 5.7" liquid crystal type (STN) display equipped with 320 x 240 pixel resolution, 256 color graphics and an analog touch membrane. Allen-Bradley PanelView Plus 600 1 - The touch panel is a backlit 6.0" thin film transistor (TFT) display equipped with 320 x 240 pixel resolution, 18 bit color graphics and analog touch membrane. Printer. A 40-column impact printer with paper take-up is available to provide a cycle record. Inlet HEPA Filter. An internal HEPA filter is included. CONTROL SYSTEM The control system provides precise control of the VHP M100 Biodecontamination System and uses either the Siemens S7 Series or Allen-Bradley CompactLogix 1 controller. 1 PanelView and CompactLogix are trademarks of Allen-Bradley, a Rockwell Automation Company. The PLC control stores and controls such information as the time for each phase, operating pressure, hydrogen peroxide injection rate, air flow rate and target relative humidity. The control also monitors the amount of hydrogen peroxide available for the next cycle. A prompt notifies the operator to change the hydrogen peroxide cartridge when there is insufficient hydrogen peroxide volume to run the next cycle. Additionally, the control monitors the capacity available in the desiccant cartridge and will flag the user when change-out is necessary for the next cycle. All calibration is also handled by the control. The operator interface allows the user to program the PLC without the need for a Customer-supplied PLC. Security Codes are used to prevent unauthorized operation or modification of preset or custom cycle parameters. CONSTRUCTION Case: Stainless Steel Lockable Door: Stainless Steel Hydrogen Peroxide Cartridge Interface: Flame-Resistant Plastic NOTE: The liquid hydrogen peroxide is metered with a precision pump. 3

Disposable Desiccant Cartridge: Plastic Reusable Desiccant Cartridge: Aluminum Reusable Desiccant Cartridge Regenerator Enclosure and Doors: Stainless Steel CALIBRATION STERIS recommends that all VHP M100 Biodecontamination System be calibrated at least once every six months. STERIS Service representatives can provide this service to ensure validatable operation of the unit. PREVENTIVE MAINTENANCE Customers are encouraged to contact STERIS concerning our annual maintenance program. Under the terms of the program, preventive maintenance, adjustments and replacement of worn parts are provided on a scheduled basis to help ensure optimal equipment performance and to help minimize untimely or costly schedule interruptions. STERIS maintains a worldwide staff of well-equipped, factory-trained technicians to provide these services, as well as on-site installation, training and expert repair services. Contact STERIS for details. NOTES 1. STERIS recommends a dedicated, grounded electrical circuit be provided for each unit. Extension cord use is not recommended. 2. Unit should not be installed in an area not compatible with oxidizers. Consult the MSDS regarding hydrogen peroxide sterilant. 3. Regenerator must be on a hard, level surface. 4. Access must be provided to power switch and hose connectors. 5. Hose clearance must be adequate to prevent kinks and strains on the connectors. 6. Hoses must be supported to keep them from resting on the floor or other cold surfaces. 7. Clearance must be provided to doors on the VHP M100 Biodecontamination System and regenerator. 8. Access must be provided for desiccant cartridge installation and removal. UTILITY REQUIREMENTS IMPORTANT: Refer to equipment drawing 356257-509 for installation details and specifications. Electricity M100-AB: 230 Vac, 50/60 Hz, 10 Amps M100-AB (Mobile Cart): 120 Vac, 50/60 Hz, 20 Amps M100-ABX: 230 Vac, 50/60 Hz, 15 Amps M100-S and M100-S (Mobile Cart): 230 Vac, 50/60 Hz, 10 Amps M100-SX: 230 Vac, 50/60 Hz, 15 Amps Reusable Desiccant Cartridge Regenerator: 120 Vac, 50/60 Hz, 1-, 8 Amps 230 Vac, 50/60 Hz, 1-, 4 Amps Airflow/Pressure Airflow range: 8-11 scfm (14-19 m 3 /h) Maximum control pressure: 2.3 W.G. (572 Pa). Vaprox Injection Rates: Closed-Loop, cartridge feed, cartridge desiccant: 0-12 grams/minute Open-Loop, bulk-fill with external continuous operation: 0-25 grams/minute ENVIRONMENTAL FACTORS Ambient Conditions Room Temperature: 50-95 F (10-35 C) Relative Humidity: 5% to 50% CUSTOMER IS RESPONSIBLE FOR COMPLIANCE WITH APPLICABLE LOCAL AND NATIONAL CODES AND REGULATIONS. STERIS Corporation, Mentor (Hopkins) Ohio is an ISO 13485 and ISO 9001 certified facility. The base language of this document is ENGLISH. Any translations must be made from the base language document. 4

Reference listed equipment drawing for detailed installation specifications. Obtain this drawing from your STERIS Representative. Equip. Dwg. No. Equipment Drawing Title 136816-273 Small Volume VHP 100R Regenerator Dimensions are typical drawing is not to scale. Dimensions are inches (mm) [457] FOR DOOR SWING ELECTRICAL CONNECTION COOLING AIR INLET PROCESS AIR INLET FLOOR 5

Reference listed equipment drawing for detailed installation specifications. Obtain this drawing from your STERIS Representative. Equip. Dwg. No. Equipment Drawing Title 356257-509 VHP M100 Single-Pass (M100-SX/M100-ABX/M100-MIX) Dimensions are typical drawing is not to scale. Dimensions are inches (mm) CABINET VENT AIR INLET 38 MM TRI-CLOVER FITTINGS H202 FILL INLET (CONNECTOR TO EXTERNAL) BULK LIQUID H202 SUPPLY) H202 RESERVOIR LEVEL VIEWING WINDOW POWER SWITCH OPERATOR INTERFACE PRINTER Not For Installation STERILANT OUTLET COOLING FAN (FAN BLOWS INTO CABINET) 180 DOOR OPENING 6

Reference listed equipment drawing for detailed installation specifications. Obtain this drawing from your STERIS Representative. Equip. Dwg. No. Equipment Drawing Title 356257-535 VHP M100 CLOSE-LOOP (M100-S/M100-AB) Dimensions are typical drawing is not to scale. Dimensions are inches (mm) CABINET VENT AIR RETURN STERILANT OUTLET 38 mm TRI-CLOVER FITTINGS CARTRIDGE ASSEMBLY OPERATOR INTERFACE PRINTER Not For Installation POWER SWITCH REUSABLE DRYER CARTRIDGE OPTIONAL COOLING FAN (FAN BLOWS INTO CABINET) 7

For Further Information, contact: STERIS Corporation 5960 Heisley Road Mentor, OH 44060-1834 USA 440-354-2600 800-548-4873 www.steris.com SD776 2008, STERIS Corporation. All rights reserved. (07/01/08) This document is intended for the exclusive use of STERIS Customers, including architects or designers. Reproduction in whole or in part by any party other than a Customer is prohibited.