BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Similar documents
Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

TRUST THE ORIGINAL. SUBMITTAL PACKAGE

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

Sound Cover [ , , , ]

installation, operation & Maintenance manual Floor-mounted Induction units

SEALING FIBER SEALING COMPOUND

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

Seung-Jin Ind.Co.,Ltd.

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

INSTRUCTION MANUAL HS-229G

10.85 VicFlex Sprinkler Fittings

Flat Line Spray Systems Kits

AeroVent 1 Product Manual

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

installation, operation & Maintenance manual acb ceiling-mounted cassette models

Design Criteria. Installation

INSTALLATION AND OPERATING MANUAL

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

Installation Instructions PP-AS20 Anti-Scale System

FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

Technical Data. Installation

MaxLite LED MICRO-T PANEL

55-Gallon Dispenser Package

Installation Instructions / Warranty

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Installation Instructions / Warranty. Metris 31060XX XX XX1

WATER POWERED OSCILLATING MONITOR

mechanical. OPERATION Rapidrop Global

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC015 - AC016 - AC018

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

BUNN A10 & A10-A BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Installation Instructions

Installation Instructions / Warranty

INSTALLATION AND OPERATING MANUAL

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

AeroVent 3X Product Manual

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Installation Instructions / Warranty

Industrial Vacuums, Inc

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure

Installation Manual Universal Top-of-Pole Mount UNI-TP/08LL

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

Easy installation in both new construction and retrofit

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Owner Instructions. Warning! Read instructions before using the machine. Model: SSS 1500C Back Pack Vacuum

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

FRESH HEAD. MANUAL TOILET for pressurized fresh water rinse INSTALLATION AND MAINTENANCE INSTRUCTIONS

Power Pack Service Manual

MODEL NO CRIMPING AND BEADING MACHINE OPERATION, PARTS & MAINTENANCE MANUAL

MaxLite LED Round Pendant Highbay Series

GALE FORCE VAF-16R. Ventilation Manual

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Easy installation in both new construction and retrofit

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

B.I.C.A Built-In Coffee Appliance

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

GP-6 Cabmaker Owner s Manual and Operating Instructions

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

FW-RA-LED Remote Multiplex Annunciator Panels

Compact Equipment Warranty Policy

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

Pole Mounting System Installation & Certification Manual

FOR EASY, FAST INSTALLATION AND FOR RESULTS

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

DISCARD DECANTER IF: FAILURE TO COMPLY RISKS INJURY FUNNEL CONTENTS ARE HOT ILLUSTRATED PARTS CATALOG

AeroVent Standard Product Manual

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

55-Gallon Dispenser Package

M Series Fan Filter Units

Installation Instructions / Warranty. Starck 10111XX XX XX1

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

FRESH HEAD. MANUAL TOILET for pressurized fresh water rinse INSTALLATION AND MAINTENANCE INSTRUCTIONS

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Corrosion Resistant Fluid and Air Handling Systems.

Heater Installation Kit

POWER PACK SERVICE MANUAL

Desiccant Air Drying System

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

OWNER'S MANUAL BBC-270. Bidet Attachment . '

FLASH XTRACTOR II NEXT GENERATION SUB-SURFACE FLOOD EXTRACTION TOOL AC002

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Transcription:

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS Product Submittal A PART OF

Limited Warranty SprinkFLEX warrants that its products will be free from defects in materials and workmanship under normal conditions of use and service for a period of one year from date of sale. Our obligation under this warranty is limited to repairing or replacing any product that is returned to us with transportation charges prepaid within one year after the date of original sale and that our examination shows to our satisfaction to have been defective in materials or workmanship under normal conditions of use and service. The decision as to whether to repair or to replace any product shall be made by us, and any repair shall be made at our facility. Notwithstanding the foregoing, the following are specifically excluded from the coverage of this warranty: (a) the sprinkler head of any SprinkFLEX product, but SprinkFLEX hereby assigns to the original purchaser of any such product the right to enforce the warranty, if any, issued by the manufacturer of such sprinkler head; (b) defects resulting from ordinary wear and tear, of any SprinkFLEX Product; (c) products that have been altered in any manner by the buyer or by anyone other than SprinkFLEX ; (d) products that have been subjected to misuse, abusive use, or damage by accident or casualty; (e) products that have been installed or used in a manner contrary to our specifications, instructions or recommendation; (f) products that have been installed or used in a manner that is not in compliance with all applicable requirements of any code, law, regulation or rule of any federal, state or local governmental or industry authority; and (g) products that have not been inspected and maintained in accordance with our specifications, instructions or recommendations, including, without limitation, our recommendations as to following the inspection and maintenance standards published by the National Fire Protection Association (NFPA); and (h) products that have been affected by Microbiologically Influenced Corrosion (MIC). This warranty is not assignable and shall benefit only the original purchaser of a SprinkFLEX product. If any provision hereof or any portion of any provision shall be held invalid, the remainder of this Limited Warranty shall not be affected thereby, and all provisions of this Limited Warranty shall remain valid and in full force and effect to the fullest extent permitted by law. THIS WARRANTY IS IN LIEU OF ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY AND WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. NOTWITHSTANDING ANY PROVISION TO THE CONTRARY HEREIN OR ANY APPLICABLE LAW TO THE CONTRARY, IN NO EVENT SHALL SPRINKFLEX BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES UNDER ANY CIRCUMSTANCES WHATSOEVER, WHETHER ARISING FROM ANY BREACH OF THIS LIMITED WARRANTY OR OTHERWISE ARISING FROM OR IN CONNECTION WITH THE USE OR OPERATION OF, OR ANY DEFECT IN, ANY SPRINKFLEX PRODUCT, OR OTHERWISE. The risk of damages from any breach of warranty with respect to injury to any person will be born by the purchaser of SprinkFLEX.

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler using a flexible stainless steel hose and reducer. The flexible stainless steel hose and fittings are intended for direct connection to the sprinkler and are particularly suited for use in suspended and hard ceiling applications. Each drop assembly comes with one stainless steel flexible hose, one branch line connection nipple, one sprinkler reducing nipple and bracket system. SYSTEM OPTIONS Pre-assembled, ready to install, unbraided and braided flexible stainless steel hose lengths: 28" (700mm), 40" (1000mm), 48" (1200mm), 59" (1500mm), 71" (1800mm) 1 2 and 3 4 outlet fittings for connecting sprinkler Pre-assembled, ready to install mounting bracket available in 24" and 48" long Mounting bracket allows the sprinkler to be located anywhere within the ceiling with reference marks in the center for ease of installation without the need for measuring. Optional factory installed sprinkler head. TECHNICAL DATA Maximum Working Pressure: 200 psi (1375 kpa) Maximum Ambient Temperature: 300 F (149 C) Connection to Branch Line: 1-inch NPT Minimum Bend Radius of Flexible Stainless Steel Hose: 3 inches (76.2 mm) per UL Listing 8 inches (203.2 mm) per FM Approval The flexible stainless steel hose should not be bent within 2 1 2 inches (64 mm) of the connection nut at both ends. Equivalent lengths are shown with maximum number of 90 degree bends at the minimum bend radius. 2-45 degree or 3-30 degree bends equal 1-90 degree bend FM equivalent length calculation include sprinkler head Friction Loss. UL equivalent length calculation include the hose only. UL Maximum K-Factor of Sprinkler to be connected to Sprinkler Reducing Nipple: 1 2 inch outlets: 8.0 3 4 inch outlets: 11.2 FM Maximum K-Factor of Sprinkler to be connected to Sprinkler Reducing Nipple: 1 2 inch outlets: 5.6 3 4 inch outlets: 8.0 Listings and Approvals: Unbraided models are UL Listed Braided models are FM Approved and UL Listed

FLEXIBLE HOSE - NON BRAIDED NO. DESCRIPTION NO. DESCRIPTION 1 Flexible Hose 7 8" Nominal Diameter 5 Nipple 2 Ring 6 Reducer 1 2" or 3 4" 3 Washer 7 Plastic Cap 4 Slip Nut FLEXIBLE HOSE - BRAIDED NO. DESCRIPTION NO. DESCRIPTION 1 Flexible Hose 7 8" Nominal Diameter 5 Nipple 2 Ring 6 Reducer 1 2" or 3 4" 3 Washer 7 Braid 4 Slip Nut 8 Plastic Cap BRACKET ASSEMBLY NO. DESCRIPTION NO. DESCRIPTION 1 24" or 48" Support Bar 4 Hex Screw 2 Center Bracket Assembly 5 Wing Bolt 3 Clamp MATERIAL SPECIFICATIONS Corrugated Flexible Hose: SS304 SEAL: EPDM SLIP NUT AND NIPPLE: Zinc-Plated Carbon Steel Slip Nut and Nipple: Zinc-Plated Carbon Steel BRAID AND BRAID RING: SS304 Support Bar: G90 Galvanized Steel Clamp and Center Bracket Assembly: G90 Galvanized Steel Hex Screw and Wing Bolts: Zinc-Plated Carbon Steel Optional Tamper-Resistant Screw: Zinc-Plated Carbon Steel

UNBRAIDED HOSE UL LISTED MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH (mm) UL 3" BEND RADIUS MAXIMUM NUMBER OF UL LISTED UNBRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 40 1" DIAMETER PIPE (C=120), FT SFN28H 1 x 1 2 28" (700mm) 2 22 SFN28T 1 x 3 4 28" (700mm) 2 28 SFN40H 1 x 1 2 40" (1000mm) 3 39 SFN40T 1 x 3 4 40" (1000mm) 3 54 SFN48H 1 x 1 2 48" (1200mm) 3 56 SFN48T 1 x 3 4 48" (1200mm) 3 63 SFN59H 1 x 1 2 59" (1500mm) 3 59 SFN59T 1 x 3 4 59" (1500mm) 3 74 SFN71H 1 x 1 2 71" (1800mm) 3 67 SFN71T 1 x 3 4 71" (1800mm) 3 74 *Series SFN models are unbraided/series SFB models are braided *Unbraided hoses are UL Listed *Braided hoses are FM Approved and UL Listed FRICTION LOSS DATA BRAIDED HOSE FM APPROVED AND UL LISTED MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH (mm) UL 3" BEND RADIUS MAXIMUM NUMBER OF UL BRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 40 1" DIAMETER PIPE (C=120), FT FM 8" BEND RADIUS MAXIMUM NUMBER OF FM BRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 40 1 INCH DIAMETER PIPE (C=120), FT SFB28H 1 x 1 2 28" (700mm) 2 24 1 46.4 SFB28T 1 x 3 4 28" (700mm) 2 29 1 39.1 SFB40H 1 x 1 2 40" (1000mm) 3 44 1 53.9 SFB40T 1 x 3 4 40" (1000mm) 3 54 1 45.3 SFB48H 1 x 1 2 48" (1200mm) 3 63 2 73.4 SFB48T 1 x 3 4 48" (1200mm) 3 55 2 64.3 SFB59H 1 x 1 2 59" (1500mm) 3 76 3 89.9 SFB59T 1 x 3 4 59" (1500mm) 3 70 3 86.5 SFB71H 1 x 1 2 71" (1800mm) 3 78 4 112.8 SFB71T 1 x 3 4 71" (1800mm) 3 92 4 104.9 BRAIDED HOSE WITH ELBOW - FM APPROVED MODEL INLET & OUTLET SIZE NPT INCH LENGTH INCH (mm) FM 8" BEND RADIUS MAXIMUM NUMBER OF FM BRAIDED HOSE MAXIMUM EQUIVALENT LENGTH OF SCH 40 1" DIAMETER PIPE (C=120), FT SFB28H E 1 x 1 2 28" (700mm) 1 48.4 SFB28T E 1 x 3 4 28" (700mm) 1 41.1 SFB40H E 1 x 1 2 40" (1000mm) 1 55.9 SFB40T E 1 x 3 4 40" (1000mm) 1 47.3 SFB48H E 1 x 1 2 48" (1200mm) 2 75.4 SFB48T E 1 x 3 4 48" (1200mm) 2 66.3 SFB59H E 1 x 1 2 59" (1500mm) 3 91.9 SFB59T E 1 x 3 4 59" (1500mm) 3 88.5 SFB71H E 1 x 1 2 71" (1800mm) 4 114.8 SFB71T E 1 x 3 4 71" (1800mm) 4 106.9

56 Lowland Street Holliston, MA 01746 TOLL FREE / 800-829-6975 FAX / 508-893-6020 sprinkflex@gmail.com www.sprinkflex.com 2017 Atkore International, Inc. All rights reserved. SPF-L-9000-1712