SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

Similar documents
SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

WF2613 Classic Corner Washfountain with 9" Deep Bowl

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

SS-3N Express Lavatory System SS-Series

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

AV30 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

Express Lavatory System MG-Series

Express Lavatory System MG-Series

AV60 Advocate Lavatory System AV-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

AV90 Advocate Lavatory System AV-Series

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

LD-5010 OmniDeck with WashBar 5000 Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

AV60 Advocate Lavatory System AV-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Model Z Sundara Reef Triple Basin Hand Washing System

Installation Instructions

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVQD3 Verge with WashBar Technology LVQ-Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

HL45, HL80 Thermostatic High-Low Valves

LVSD2 Verge Wash Basin LVS-Series

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

Model Z Sundara Float Double Basin Hand Washing System

Installation Instructions

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

Installation Instructions

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

FL-3H, FL-3L Frequency Lavatory System FL-Series

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Installation Instructions

Installation Instructions

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

LVQD1 Verge with WashBar Technology LVQ-Series

Washfountain Application Guide

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

School Solutions Ideabook

Installation Instructions OBSOLETE

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Installation Instructions

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

TMV45 & TMV80 Standard Thermostatic Mixing Valves

Installation Instructions

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Geo Series KPF-1702 / KPF-1750 Make a Bold Statement in Your Kitchen

PRO SERIES IMPORTANT SAFETY INFORMATION

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Durability within reach

LA45 DISCONTINUED IMPORTANT!

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

MERIDIAN MODEL# 3793

cygnet stainless Product Catalog toll free

DESIGN AND CONSTRUCTION STANDARDS July 2011

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

A. Section Joint Sealants: Seal fixtures to walls and floors.

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

LA60 DISCONTINUED IMPORTANT!

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Distributed By: M&M Control Service, Inc SURFACE MOUNT SHOWER SYSTEMS

Product Specification

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Transcription:

SN2003, SN2023, SN2004, SN2024 cupc Certified Available with Infrared, Air or TouchTime Available in a 54" or 36" Bowl Size Wall-Mounted or Floor-Mounted Standard Height Models and Juvenile Height 54" Models with Air (Hand), Infrared or TouchTime Pushbutton and Piezo are ADA/TAS Compliant Factory Tested and Shipped Pre-assembled Vandal Resistant and Easy to Clean Specifications Size and Capacity Accommodates 3 users (36" models) or 4 users (54" models) at a time, using less water, energy and space than lavs equipped with conventional faucets. The sectional sprayhead module is controlled by a push button, which actuates an air valve (hand or foot control models), or a solenoid valve (TouchTime models) or by an infrared sensor-actuated solenoid. Flow restrictor keeps flow rate constant at 0.5 GPM per station for all pressures. Operating range is 20-80 PSI. Construction Bowl and Pedestal All exposed materials are type 304 stainless steel polished to a #4 finish. Bowl, pedestal and access panels, frame, foot control housing; support tube; and sprayhead are heavy gauge stainless steel. Exposed fittings are chrome plated. Vandal Resistance Bowl and support tube are an integrally welded assembly, with the support tube welded to an extruded flange from bowl. Sprayhead nozzles and push buttons/infrared sensors are secured to unit from inside the sprayhead module. Air valves/solenoid valves are safely concealed inside the washfountain. Access panels are removable. All supply and waste connections are concealed within the pedestal. Mounting Heights Sentry washfountains can be installed at standard or juvenile height. Floor-mounted models require mounting height selection. Wall-mounted units are simply installed at the desired height. Standard Equipment Valves and Fittings In addition to the bowl and pedestal, the following valves and fittings are standard: Navigator thermostatic mixing valve, flexible stainless steel supply hoses and stops. Stops are 1/2" compression female. Activation Types Air Hand Activation Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates one valve which, in turn, activates one station. Push button requires less than five pounds of pressure. Air - Hold Open Foot Activation Each push button pneumatically actuates a hold-open air single temperature valve with slow closing upon release of foot pressure. Push button requires less than five pounds of pressure. Infrared Each of the stream formers is controlled by a separate slow-closing solenoid valve. Hands placed within the bowl are detected by an infrared sensor module, which activates a flow of tempered water from one spray nozzle. Shut-off is automatic after hands are removed from the detection area. The infrared sensor module uses two zone-focused infrared transmitting beams, having a detection area that does not exceed the bowl perimeter. The detection range projects 6 9 inches forward at a 30 angle to each side and reaches 15 below horizontal. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low voltage transform as standard equipment: Solenoid 12VDC, 3/8" tube fitting. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Plug-In Adapter UL/CSA-Listed 120VAC/12VDC plug in adapter designed to plug into a standard GFCI protected electrical outlet. Location of plug-in adapter per local electrical code. Page 1 of 6 9/18/2017 SN2023 (Infrared, Wall Mounted) SN2003 (Air Valve Foot Control) TouchTime Each low-voltage pushbutton or piezo switch actuates a non-hold-open, slow closing antihammer solenoid valve that is timed from an electronic potted assembly. Each pushbutton activates one valve which, in turn, activates one station. TouchTime controls water flow at each station through the use of solid state, digital circuitry. Timing is factory set at a 15 second run time, but is field adjustable to pre-set time out periods and optional auto-flush function. The 24 hour flush function will activate water flow for a period of 60 seconds any time there has been no activation within the past 24 hours. Pushbutton requires less than five pounds of pressure. Code Compliance and Certifications cupc Approval Sentry Washfountains are Uniform Plumbing Code (UPC), International Plumbing Code (IPC) and National Plumbing Code of Canada (NPC) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). Manufactured in compliance with IGC 156-2009, CSA B45 Series-2002 (R08) & ASME A112.18.1-2005/CSA B125.1-2005. ADA and TAS (Texas Accessibility Standards) Compliant All floor and wall mounted standard height models and Juvenile Height 54" models, with air metering hand, infrared or TouchTime activation, comply with all ADA/TAS guidelines on reaches, clearances and operation. Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement. Certified to NSF/ANSI 372 SN2024 (Infrared)

SN2003, SN2023, SN2004, SN2024 Models (Must select one) Model Size Stations Description SN2003 36" 3 Floor-Mounted* SN2004 54" 4 Floor-Mounted* SN2023 36" 3 Wall-Mounted* SN2024 54" 4 Wall-Mounted* Standard Selections (Must select one from each category) Drain Type (select one) A Off-line vent with supplies from below B Centrally rising vent with supplies from above Rough-In Dimensions for Bowl and Pedestal Wall Anchors H O Centrally rising vent with supplies from below Off-line vent with supplies from above Mounting Height Type (Models SN2003 & SN2004 only) (select one) STD Standard Height JUV Juvenile Height Activation Type (select one) AST4 Air - Hand Activation IRP Infrared AST4-F Air - Hold Open Foot Activation (SN2003 and SN2004 only)** Soap Dispenser Type (select one) LSD Two Integral Liquid Soap Dispensers NSD No Soap Dispenser Water Supply Type (select one) TMA Thermostatic Mixing Valve PBV Pressure Balance Mixing Valve TTPA TTPB TL TouchTime Pushbutton TouchTime Piezo Switch Tempered Line Supply Optional Selections Backsplash Type BS Bolted On Backsplash NBS No Backsplash Towel Dispenser Type CFTD (2)C-Fold, Multi-Fold Dispenser SFTD (2) Single-Fold Dispenser Shroud Type (Models SN2003 & SN2004 Only) SH Stainless Steel Shroud (Conceals overhead plumbing) NONE No Shroud 36: 13-3/8" (340) 54: 22-3/8" (568) 36: 13-3/8" (340) 54: 22-3/8" (568) NONE No Towel Dispenser * Models are ADA/TAS Compliant when mounted at standard or juvenile height dimensions with infrared, TouchTime or air metering hand activation. ** Non-cancelable, not-returnable Shroud is recommended for drain type B, H and O to conceal vent and/or supplies. 4" (102) 1-3/4" (44) 32-1/2" * (826) 4" (102) 24-3/4"* (629) Rough-In Notes Anchor locations for 3/8" diameter bolts, both supplied by installer. Wall mounted 54" and 36" models with TouchTime, Infrared or air metering hand activation are ADA/TAS compliant when mounted at standard height dimensions. Wall mounted 54" model with TouchTime, Infrared or hand metering hand activation is ADA/TAS compliant when mounted at juvenile height. * Subtract 4" (102) from this dimension for juvenile height. Page 2 of 6 9/18/2017 120 Volt Electrical Box for Units with Infrared Activation (Recommended Location; See Local Electrical Codes Before Roughing in) 8-3/8" JUV (213) 8" STD (203) Floor Mounted Only 9" (229) 8-3/8" JUV (213) 8" STD (203) Floor Mounted Only Floor Mounted Only 9" (229) 4-3/4" (121) 14-3/4"* (375) 14-1/2"* (368)

Dimensions - Sentry 54" Floor Mounted Infrared Activation SN2003, SN2023, SN2004, SN2024 Dimensions - Sentry 36" Floor Mounted Infrared Activation 16-3/8" (416) 25-1/4" (641) Hand Activation (AST4 and TouchTime) Hand Activation (AST4 and TouchTime) 16-3/8" (416) 25-1/4" (641) Air Valve - Hold Open Foot Activation Air Valve - Hold Open Foot Activation 8-11/16"* (221) 25-1/4" (641) Standard height 36" and 54" models with TouchTime, Infrared or air metering hand activation are ADA/TAS compliant when mounted at standard height dimensions. Juvenile height 54" model with TouchTime, Infrared or air metering hand activation is ADA/TAS compliant. * Subtract 4" (102) from this dimension for juvenile height. Page 3 of 6 9/18/2017 2-1/4" (57) 4-1/8" (105) 3-1/16"* (81) 1 (476) 2-1/4" (57) 3-15/16" (100)

SN2003, SN2023, SN2004, SN2024 Dimensions - Sentry 54" and 36" Wall Mounted 54" Infrared Activation 54" Hand Activation (AST4 and TouchTime) 16-3/8" (416) 35-1/4" (895) 16-3/8" (416) 35-1/4" (895) 36" Infrared Activation 36" Hand Activation (AST4 and TouchTime) 26" (660) 9" (229) Wall mounted 54" and 36" models with TouchTime, Infrared or air metering hand activation are ADA/TAS compliant when mounted at standard height dimensions. Wall mounted 54" model with TouchTime, Infrared or air metering hand activation is ADA/TAS compliant when mounted at juvenile height. * Subtract 4" (102) from this dimension for juvenile height. Page 4 of 6 9/18/2017

Rough-In Dimensions for Drain and Supplies SN2003, SN2023, SN2004, SN2024 Type A Off-line vent with supplies from below 2-3/4" (70) Stub Up 3" (76) (Optional) Type B Centrally rising vent with supplies from above Stub Up 3" (76) (Optional) 2-3/4" (70) 1/2" Nom. Copper Tube Supplies from Above Must Be Located on These Centers to Pass Through Washfountain Shroud and Sprayhead 5" (127) 1/2" Nominal Copper Tubing Supplies 5" (127) 4-1/2" (114) Centerline of Washfountain Supplies Through Floor Stub Up 2-1/2" (64) (Optional) : Stub out to Suit Trap 36: 7-9/16" (192) 54: 8-1/16" (205) 36: 54: 9-1/4" (235) Vent from Above Centerline of Washfountain Supplies from Above Supplies Supplies and Drain Through Floor (Optional) ** Vent from Above : Stub out to Suit Trap Drain Through Floor (Optional) ** Std: 12" (305) Juv: 8" (203) ** Floor Mounted Units Only Type A Drain Supplies below Off-drain vent P-Trap furnished by others Type B Drain Supplies above Centrally-rising vent P-Trap furnished Rough-In Notes 1. Maximum flow rate required to washfountain is 1.5 GPM for Models SN2003 and SN2023 or 2.0 GPM for Model SN2004 and SN2024. Size supply lines accordingly. 2. Unit with A drain and paper towel dispensers and/or a shroud, should use H drain Rough-Ins. Page 5 of 6 9/18/2017

Rough-In Dimensions for Drain and Supplies SN2003, SN2023, SN2004, SN2024 Type H Drain Centrally rising vent with supplies from below Type O Drain Off-line vent with supplies from above Stub up 3" (76) (Optional) 1/2" Nominal Copper Tubing Supplies 36: 54: 9-1/4" (235) 5" (127) 2-3/4" (70) 1-1/2" NPT Vent from Above 4-1/2" (114) 4-1/2" (114) Centerline of Washfountain Supplies Through Floor: Stub up 2-1/2" (64) (Optional) Vent from Above 2-3/4" (70) 1/2" Nom. Copper Tube Supplies from Above Must Be Located on These Centers to Pass Through Stub up 3" (76) (Optional) Washfountain Shroud and Sprayhead 5" (127) 36: 7-9/16" (192) 54: 8-1/16" (205) Centerline of Washfountain 1/2"Nominal Copper Tubing Supplies from Above Through Wall: Stub out to Suit Trap Supplies Supplies and Drain Through Floor (Optional) ** Through Wall: Stub out to Suit Trap Drain Through Floor (Optional) ** Std: 12" (305) Juv: 8" (203) ** Floor Mounted Units Only Type H Drain Supplies below Centrally-rising vent P-Trap furnished Type O Drain Supplies above Off-drain vent P-Trap furnished by others Rough-In Notes 1. Maximum flow rate required to washfountain is 1.5 GPM for Models SN2003 and SN2023 or 2.0 GPM for Model SN2004 and SN2024. Size supply lines accordingly. 2. Unit with "O" drain and paper towel dispensers and/or a shroud, should use "B" drain Rough-Ins. Page 6 of 6 9/18/2017