Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Similar documents
MODEL SS4-A/-A2 (CENELEC)

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Model 3300 Technical Support and Installation Manual

Multi-Spectrum Digital Electro-Optical Fire Detectors

Installation Guide and Operating Manual Fire Detector with 20-foot Pigtail Cable Model FS RP

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

Multi-Spectrum Digital Electro-Optical Fire Detector

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Multi-Spectrum Digital Electro-Optical Fire Detectors

Dräger Flame 2500 Flame Detection

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom

Dräger Flame 2100 Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

SEC 2000 Millenium Infrared Gas Detector

FSX Fire and Flame Detectors

Installation Guide and Operating Manual

Basic Vehicle Fire Protection Manual

2018 Product Guide Americas Industrial Fixed Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Flame Detection Jon Sarfas

Infrared (IR) Digital Electro-Optical Fire Detector. Installation Guide and Operating Manual

Dräger Flame 2350 (UV&IR) Flame Detection

Open-area Smoke Imaging Detection (OSID)

Dräger Flame 5000 Flame Detection

Flame Detector Accessories

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Multi-Spectrum Digital Electro-Optical Fire Detectors

Dräger Flame 2100 (UV) Flame Detection

SEC Signature Process Gas Analyzer

Dräger Flame 5000 Flame Detection

Installation Guide and Operating Manual

Dräger Flame 2370 (UV&IR) Flame Detection

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Open-area Smoke Imaging Detection (OSID)

Dräger Flame 2700 (Multi-IR) Flame Detection

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

Model D12-IR. Digital Gas Transmitter...

7800 SERIES RM7888A Relay Module

SIL 2. Ultima X Series Gas Monitors CERTIFIED

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

The SharpEye 40/40M (Multi IR) Flame Detection

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

APPLICATION OF VISUAL FLAME DETECTION

Dräger Polytron Pulsar 2 Open Path Gas Detector

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Centro-Matic Automated Lubrication Systems System Controls

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

Ammonia Leak Detector Manual

COMPACT FLAME CONTROLLER CFC 1000

FS19X & FS20X WideBand IR TM / UV

The SharpEye 40/40I (IR3) Flame Detection

Talentum Flame Detector User Guide

Dräger Polytron 5100 EC Detection of toxic gases and vapors

FAAST. Fire Alarm Aspirating Sensing Technology

Eclipse Self-Check UV Scanner

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Danfoss gas detection units

7800 SERIES EC7885A/RM7885A Relay Module

COMPACT FLAME CONTROLLER CFC 2000

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Commercial and Light Industrial Fire Alarm Control Panel

7800 SERIES EC7823/RM7823 Relay Module

Ultra Fast UV/IR Flame Detector

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Instructions AutroFlame IR Flame Detector BG-201/BG-21

FAAST. Fire Alarm Aspirating Sensing Technology

7800 SERIES RM7888A Relay Module

FlameGard 5 UV/IR HART

SEC Millenium Carbon Dioxide Gas Detector

AlarmLine Linear Heat Detector

Dräger REGARD -1 Control System

Across-the-Line SERIES MP300 Combined Manual and Automatic

Instructions Protect ir Multispectrum IR Flame Detector with Pulse Output X3300

Eclipse 90 UV Scanner Model A Version 1

FlameGard 5 MSIR HART

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Pioneer-R16 Gas Monitor Operator s Manual

FIREYE C9707A ALL FUEL SCANNER

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Transcription:

Fire Sentry Corporation (FSC) 593 Apollo Street Tel.: 714-671-1100 Brea, California 92821 Fax: 714-671-5821 Multi-Spectral, Digital, Infrared Electro-Optical FSC Model No. s FS10-R and FS10-A Unitized, Two Stage, Quick Response Flame Detectors with Wide Band IR Unitized, Stand-Alone Version Detectors with Relay or 4-20 ma Analog Output SPECIFICATIONS

Fire Sentry Corporation (FSC) Page 1 1.0 APPLICATION The Fire Sentry Models FS10-R (relay output) and FS10-A (analog output) are unitized (stand-alone) Flame Detectors designed specifically for detecting and alarming to fires in electrostatic paint spray booths and paint spray lines in industrial and automotive applications. These multi-spectral, digital, electro-optical Flame Detectors are housed in explosion proof enclosures and feature automatic "through-the-lens" self-test. The Detectors may be ordered with either dry contact relay or 4-20 ma analog outputs for interfacing to approved control panels. FS10-R Detectors each contain a built-in controller and are unitized versions of the proven, large installed base of the FS10 Flame Detectors with Card Controllers and FS10 Flame Detectors with Wall- Mounted Controllers. The FS10 line of Detectors is designed primarily for indoor fire detection applications where combustible materials exist. Typical applications include: - Automotive Painting - Aerosol Filling - Paint Kitchens - General Finishing - Curing Ovens - Paint Mixing Rooms - Powder Coating Booths - Warehouse Storage - Internal Storage Tanks - Liquid Paint Spray Lines - Compressor Modules - Diesel Generators 2.0 DESCRIPTION These multi-spectral flame Detectors, using Fire Sentry Corporation patented technology, span the Wide Band Infrared (IR), Near Band IR, and Visible Band spectrums. Using microprocessor technology and digital signal processing, the Detectors can distinguish between a real fire and false alarm radiant energy sources. The Detectors simultaneously examine these three spectral radiant energy bands continuously and perform real-time Digital Signal Processing. The Detector stores all of the pre-fire spectral data from the multi-spectral sensor array in non-volatile on-board memory for retrieval and evaluation. The FS10-R and FS10-A store the last six FirePic events, each 8 seconds long; and 200 Event Histories with time and date stamp. The FirePic data can be used to help postulate the cause of a fire. 3.0 FEATURES! Immune to false alarms caused by arcs or corona discharges.! Built-in automatic "through-the-lens" self-test.! Unique two-stage ALERT and FIRE ALARM responses.! Not affected by absorbing smoke or paint solvent mist in liquid paint spray booth.! Sees through paint, powder or oil residue on Detector's lens.! Optional factory sensitivity settings.! Sealed module containing electronics and sensors.! Optional swivel mount for easy installation and positioning.! Standard explosion-proof housing.! Low power consumption (relay version), 3.36 watts @ 24 VDC during alarm condition.! FirePic: retrieval of recorded pre-fire data.! SnapShot: dynamic real-time graphical display of what Detector sees.! Easy-to-use Windows PC software available for accessing FirePic and SnapShot.

Fire Sentry Corporation (FSC) Page 2 4.0 DETECTOR OPERATION Fast reacting, digital, microprocessor-based, multi-spectral, electro-optical Flame Detector with built-in controller. Detector will respond to both fireball and flickering fires and is used as a stand-alone (unitized) device that interfaces with approved fire alarm panels. This Detector is housed in an explosion-proof enclosure and incorporates built-in "through-the-lens" optical testing of both the sensing elements and the window lens. This model is designed for indoor applications only. Once powered by 24 VDC, the Detector performs "through-the-lens" test every 10 minutes (factory-set). If the "through-the-lens" Detector test fails, the Detector LED will blink three times every 10 seconds. This usually indicates a dirty window lens or a missing or dirty reflector lens guard. While these self-tests are occurring, the Detector is still functional and able to alarm to a fire. WARNING: Responses to the FS10-R Detector relay output or FS10-A analog 4-20 ma output must be isolated mechanically (not solely by programming the control panel using software or firmware). This will avoid external alarms and/or suppression discharge when performing the following manual Detector test with a Portable Test Lamp, such as the Fire Sentry Model FS-846. A manual Detector "end-to-end" test can be performed by activating the Detector using a portable Test Lamp, such as the Fire Sentry Model FS-846 handheld tester. The Detector's built-in microprocessor provides the following Advanced System Diagnostics: FirePic : Stores the sensor spectral data of the last six fire events in Detector's non-volatile digital memory. FirePic provides the numerical spectral evidence to postulate the cause of a fire. The Detector records the time and the date of each FirePic. SnapShot : Displays and records dynamic graphical display of what Detector sees. Event History: Contains the Detector's time and date stamped files of Alarm, Fault, Reset, etc. other than normal operations. The above Detector system diagnostics can be accessed by using the optional Windows PC Interface Kit (Part No. FS10-IK), through the Detector s built-in RS-485 communication channel located on the module s 10 pin connector. 5.0 DETECTOR WIRING The recommended Detector wiring is a 10-conductor, twisted pair, shielded, 18 to 22 gauge cable, and rated @ 300 Volts rms minimum. When installed in a hazardous area, a metal conduit and proper conduit seals must be installed that meet the National Electric Code and any other local codes. The conduit should not be used for other electrical equipment. Connection to the Detector is through a 10-pin plug-in connector located at the back of the Detector module. 6.0 SPECIFICATIONS 6.1 GENERAL 6.1.1 Field of View 90 Degrees (+ 45 º horizontal and vertical) 6.1.2 Spectral Sensitivity Wide Band Infrared: 0.7 to 3.5 micrometers Near Band Infrared: 0.7 to 1.1 micrometers Visible Band: 400 to 700 nanometers 6.1.3 Response Time Alert: 0.3 second (response to "fireball" type fires) Fire Early Warning: 1 second (early response to a fire alarm) Fire Alarm: Less than 5 seconds (if fire continues)

Fire Sentry Corporation (FSC) Page 3 6.1.4 Sensitivity Alert/Fire Early Warning and Fire Alarm respond to a one-square foot Heptane reference pan fire at the following distances, that are pre-set at the factory: 15 feet 30 feet *45 feet -R (Relay Version) FS10-R15 FS10-R30 FS10-R45 -A (Analog Version) FS10-A15 FS10-A30 FS10-A45 *Detectors set at the 45-foot sensitivity do not have the Alert/Fire Early Warning output available. 6.2 ENCLOSURE 6.2.1 Type Copper-free aluminum, Red powder-coated finish. NEMA 3 & 4 rated 6.2.2 Weight 3.8 lbs. (1.7 Kg) 6.2.3 Dimensions 4.81 inches diameter, 4.65 inches deep 6.2.4 Conduit Entry Two 3/4" NPT 6.2.5 Mounting Optional swivel bracket assembly 6.3 ELECTRICAL 6.3.1 Input Voltage 24 VDC nominal (18 to 28 VDC) 6.3.2 Power -R Relay version: Normal 2.38 watts, Alarm 3.36 watts -A Analog version: Normal 2.38 watts, Alarm 3.64 watts 6.4 OUTPUTS 6.4.1 Relay Version Alert/Fire Early Warning (FEW): Normally Open (N.O.) relay contacts with no power applied. The relay will energize and close contacts. Relay Contact Rating: 1 amp @ 24 VDC Note: Standard factory setting is latching. The non-latching option is available. Fire Alarm: Normally Open (N.O.) relay contacts with no power applied. The relay will energize and close contacts. Relay Contact Rating: 1 amp @ 24 VDC Note: Standard factory setting is latching. The non-latching option is available. Fault: Normally Open (N.O.) relay contacts with no power applied or the relay is energized during normal operation and will de-energize and open the contacts during a Fault or power failure. Relay contact rating: 1 amp @ 24 VDC 6.4.2 Analog Version Fault: 0 ma ± 0.6 ma Normal Mode: 4 ma ± 0.6 ma Alert / FEW: 12 ma ± 0.6 ma Fire Alarm: 20 ma ± 0.6 ma Max Load Impedance: 330 Ohms 6.5 ENVIRONMENTAL 6.5.1 Operating Temperature: - 40 to +185 ºF (- 40 to +85 ºC) 6.5.2 Humidity: 10% to 90% (RH), non-condensing 6.6 DETECTOR APPROVALS Factory Mutual (FM), CENELEC, CE 6.7 ELECTRICAL CLASSIFICATION Explosion-Proof; Class I, Div. 1 & 2, Groups B, C, & D, Class II, Div. 1 & 2, Groups E, F & G, Class III

Fire Sentry Corporation (FSC) Page 4 6.8 WARRANTY Two (2) years from factory shipping date ORDERING INFORMATION FS10-R Detector with relay outputs and 15 ft. sensitivity FS10-R Detector with relay outputs and 30 ft. sensitivity FS10-R Detector with relay outputs and 45 ft. sensitivity FS10-A Detector with analog output and 15 ft. sensitivity FS10-A Detector with analog output and 30 ft. sensitivity FS10-A Detector with analog output and 45 ft. sensitivity Heavy duty swivel mount Portable handheld test lamp Air shield for powder coating or dirty applications Patented Disposable protective cover for Detector PC Windows Interface Kit for accessing Detector Data Part Number FS10-R15 FS10-R30 FS10-R45 FS10-A15 FS10-A30 FS10-A45 SM2 FS-846 DASA1-P DPC-12 FS10-IK FSC, Fire Sentry Corporation logos, Wide Band IR, Near Band IR, Visible Band, SnapShot, FirePic, FireBus, FS10, FS10-R and FS10-A are trademarks of Fire Sentry Corporation (FSC), Brea, California. This specification is subject to change without notice. Copyright 1996-1999 by Fire Sentry Corporation (FSC)