Gas Safety Devices & Accessories

Similar documents
Biological Drain Maintenance System

Combined FOG intercept and treatment system

Mobilisation Systems for Sinks & Dishtabling

Electronic Taps & Hands-Free Hardware for the ultimate in Safety & Hygiene

PROFESSIONAL KITCHEN CLEANING. New Kitchen Ventilation Systems supplied and fitted at competitive rates

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Quality Products AHU Repair, Refurbishment and Replacement

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Installation Instructions

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXTRACTION SYSTEMS

Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry

Gas safety in catering and hospitality

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

WHE 2.24 / WHE 2.24 FF

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Greenstar 12i system / 24i system

HOUSING (STANDARDS FOR RENTED HOUSES) REGULATIONS 2017

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Plus Perimeter Aspiration Timer Remote control predisposition

Fire Safety Policy Date: 0

CP+ Gas & Oil Cabinet Heater Range

GREENSTAR HIGHFLOW 440/550CDi

Howler Go-Link Evacuation Alarm

Passivhaus school kitchens

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER


Greenstar 12i/24i System

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

GS100M Gas Detection Controller

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Gas interlock system S & 100 CS

Greenstar 24i junior / 28i junior

GREENSTAR HIGHFLOW 440/550CDi

Building Services Brochure

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Installation, Operating and Servicing Instructions

Exhaust Duct Design Page 1 of (C)

ERR627SA ERR927SA. Rangehood Installation manual

Emergency Evacuation Lighting Inspection & Maintenance

EDD61 & EDD91 Extractors

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Electrostatic Precipitator

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

Chmney Hood - Model: H91PK H91PX H101PK H101PX. COOKER HOOD - User instructions

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Power flushing and protecting your heating system can increase efficiency by at least 25%.

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

USER MANUAL EFC60001 EFC70001 EFC90001

User, Installation and Servicing Instructions. Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

HHIC consumer guide to gas boiler servicing

INSTALLATION, USER AND SERVICING INSTRUCTIONS FOR ESLR9C OVEN RANGE

SPECTRA 1727 USER S GUIDE

Flue Fire Prevention Awareness

Please read this sheet as it contains important information

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

MARKET LEADERS IN LARGE SCALE COMMERCIAL CLEANING SERVICES

HULME MARTIN HEAT SEALERS

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

Loss Prevention Standards

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

Employers Responsibilities

Lo-Carbon T-series Window & Roof Models

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Vote for your Installer of the year at HEATSLAVE

ENGLISH. Contents. Technical data 10 Environment concerns 11 IKEA GUARANTEE 12

Safety and Instruction Manual

COMMERCIAL KITCHEN FIRE SAFETY

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Installation & User Instructions:

Leonardo 90 Wall Hood

Synergy Grill User & Engineer Installation & Conversion Guide

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

De Longhi Rangehood USER GUIDE. Model TA60SS (60cm) / TA90SS (90cm) Please read this user guide carefully and retain for future reference 08.

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

Domestic Gas Cookers & Ranges

Hamlet 60 & 80 Wall Hood

Health and Safety (cont)

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Rigoletto 60,90 & 120 Built-In Cupboard Hood

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

Nabucco Island Hood. Installation & User Instructions. Please read these instructions carefully before installing and operating this appliance

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

Transcription:

Gas Safety Devices & Accessories Gas Interlocks (GIS units) are required in most commercial kitchens, these systems require a number of components to comply with UK legislation. GIS UNITS WITH INTEGRAL COMPONENTS ARE SUPPLIED AS ONE COMPACT UNIT TO SAVE INSTALLATION TIME CaterGuard Advanced M-G06R Gas Interlocks save time on installations and can reduce the amount of accessories you need to purchase. Helpful, simple operation instructions are provided on the fascia of the unit. Choose from a variety of models to find the model best for your application. Solenoids, gas proving systems, fan power sensors and other accessories are also part of the range. Dedicated Helpline Dedicated technical helpline service. Helpful, simple operation instructions provided on the fascia of the unit. Full Range of Accessories Solenoids, gas proving systems, fan power sensors and other accessories are also part of the range. CaterGuard Advanced Gas Interlocks CaterGuard Advanced Gas Interlocks save time on installations and can reduce the amount of accessories you need to purchase. Call us on: +44 (0) 1908 261511 Send enquiries to: info@mechline.com Email orders to: orders@mechline.com www.mechline.com 127

GIS UNITS WITH INTEGRAL COMPONENTS One compact unit saves time on installation Built-In Emergency Cut-Off Switch Built-In Fan Power Sensors FEATURES Single box, including: - 2x on/off fans - Gas Interlock Panel - Emergency cut-off switch - Audible alarm for when gas has been shut off Complete and simple instructions on the fascia All pre-wired internally Audible alarm Built in emergency stop feature button Connections for optional Remote Emergency Stop and Fire alarm panel Anti-back pressure feature (ignores back draughts in ducting - avoiding accidental shut offs) Finished with LED lamps and high quality components Made in the UK, CE marked Guaranteed against manufacturing defects for 12 months (parts only) BENEFITS Easy to install & operate A more financially competitive solution than buying separate components Save installation time as - no need to wire individual components Flexible - can operate one or two fans Modern, compact design compatible with new kitchen designs Technical helpline service Simple for end-users to operate one button Multiple GIS solutions can be wired together to operate more than two cooking suites/islands. 128 NB: Product accreditation may not apply to all products in the relevant range. Please contact Mechline to confirm. Unless otherwise stated, all products carry a warranty of twelve (12) months against manufacturing defect or workmanship on parts. No inclusion is made for labour or site attendance. Dimensions shown in mm unless otherwise stated. Information and numerical data has been prepared as a general guide to the products but intending buyers & users must satisfy themselves as to the suitability and safety of the products for their particular purposes & duties. The WRAS Approved Product logo is a certification mark which is owned by WRAS Ltd.

Market-leading Gas Interlock System family Mechline s CaterGuard GIS units cut off gas flow in the event of kitchen extraction fan failure Mandatory requirement in most commercial kitchens Manufactured in the UK THE PURPOSE OF A GIS By monitoring airflow or fan motor running current, proper functioning of a kitchen s extraction system can be determined by the GIS, allowing gas to then be supplied to installed appliances. Monitoring is effected by air pressure differential sensors mounted in the extraction and/or air supply ductwork or via fan power sensors looking at fan motor current. In the event of fan failure or a significant air flow reduction (as calibrated by the installation engineer), the sensors will actuate the Mechline GIS which in turn closes the gas supply solenoid and thus cuts off gas supply to the kitchen appliances. WHEN IS A GAS INTERLOCK SYSTEM A MANDATORY REQUIREMENT? Gas safety interlock systems are required in all commercial kitchens. Gas Safe regulations and BS6173 both require a gas interlock system to be fitted. This ensures that the commercial kitchen ventilation system is working before the gas is turned on. This prevents a build-up of potentially poisonous gas combustion fumes in the kitchen which would be harmful to the health of kitchen staff and others within the premises. If any gas appliances do not have Flame Failure Devices (FFD s) fitted, then a gas proving system must also be fitted to comply with regulations. When to fit a GIS? On installation of a completely new extraction/ventilation canopy On installation of a completely new gas pipework run On installation of a completely new cook line or layout With any fitting of Category B equipment, e.g. combination/ convection ovens, deep fryers [with powered flues], grills, charcoal griddles etc. proving system must also be fitted to comply with regulations. ADVANTAGES OF MECHLINE S CATERGUARD GIS Smart and Compact design - Complies with new CAIS 23 [revised] Easy to Install Clear and simple instructions with diagrams Larger enclosure allows for easy installation Neat & compact and easy access for wiring Easy to Operate One button operation - all features explained fully on the fascia plate. Clear indicators LED lamps & high-quality components Key Safety Features All models have an anti-back pressure feature ignores brief back draughts in the duct and allows gas to flow. Back pressure sensitive with 10-second activation Option of fail safe double sensor warning model [M-GO3] provides the operator with peace of mind and a means of avoiding system actuation through a faulty or failed sensor. Provides clear warning that a single sensor has failed. The system only shuts off the gas supply when both sets of sensors actuate. (Please note in this instance that four sensors are required). Option of built-in emergency stop is available on units with model numbers ending in R Compliant with BS6173(2009) and Regulation 27(4) of the Gas Safety (Installation and Use) Regulations 1998 Each GIS can handle one or two fans Multiple GIS units can be wired together to operate more than two fans - Single or Double Sensor warning available Easy to clean and protected to IP54 Technical help is at hand from Mechline or from an independent Technical Adviser on 01324 829922 Call us on: +44 (0) 1908 261511 Send enquiries to: info@mechline.com Email orders to: orders@mechline.com www.mechline.com 129

GAS INTERLOCK SYSTEMS SYSTEM REQUIREMENTS GIS Unit choose from M-G01N, M-G02, M-G02R, M-G03R or M-G06R Remote or Built-in Emergency Shut-Off Switch - or both Air Differential Switch or Fan Power Sensor - unless already built-in Electrically operated, normally closed gas safety shut-off Solenoid Valve It is the Customer s responsibility to determine the suitability of the GIS system for the application M-G01N M-G02 M-G02R M-G03R M-G06R M-G01N M-G02 GIS with NO override (stainless steel panel) Standard GIS System with back pressure feature & additional connection for Remote Emergency Cut-Off Switch. Large box for easier wiring. IP55 M-G03R* With a built-in Emergency Knock Off Switch (requires 4 sensors, sold separately) *IMPORTANT NOTE: The M-G03R model will need 4 sensors to operate correctly on two fan systems. Choose between M-ADS20 or M-FPS sensors - sold separately. If you have any questions, please contact Mechline s Technical Department or contact 01324 829922, an independent Technical Help Line for Mechline s GIS units. M-G02R Same as M-G02 but with Interlock panel + built-in Emergency Knock-Off Switch M-G06R Advanced GIS system includes Interlock panel, Emergency Cut-Off Switch & Fan Power Sensors (no fan speed controllers) 130 NB: Product accreditation may not apply to all products in the relevant range. Please contact Mechline to confirm. Unless otherwise stated, all products carry a warranty of twelve (12) months against manufacturing defect or workmanship on parts. No inclusion is made for labour or site attendance. Dimensions shown in mm unless otherwise stated. Information and numerical data has been prepared as a general guide to the products but intending buyers & users must satisfy themselves as to the suitability and safety of the products for their particular purposes & duties. The WRAS Approved Product logo is a certification mark which is owned by WRAS Ltd.

ACCESSORIES GIS Sensors & Accessories M-ADS20 20-200 Air Pressure Differential Switch M-ADSEXT M-FPS-X M-RECS M-FRECS Extension Kit inc. 2m additional piping and 2 connectors Fan Power Sensor (FPS) for fans 100W to 3000W Remote Emergency Cut-Off Switch Flat Remote Emergency Cut-Off Switch Gas Solenoid Valves (normally closed-230v) NB: Not applicable to GPS Units M-VE050 1/2-inch M-VE075 3/4-inch M-VE100 1-inch M-VE125 1 1/4-inch M-VE150 1 1/2-inch M-VE200 2-inch M-VE250 2 1/2-inch M-VE300 3-inch GPS Gas Proving System (includes Gas Solenoid Valve & Control Devices) NB: Must be installed to an existing, or supplied with a new GIS system. IMPORTANT: Please identify, when ordering a GPS, the gas flow direction. M-VEGP075 M-VEGP100 M-VEGP125 M-VEGP150 M-VEGP200 3/4-inch 1-inch 1 1/4-inch 1 1/2-inch 2-inch GIS MODEL FEATURE GUIDE MODEL FEATURES Gas Interlock Panel Operates 2 Fans Built-in Emergency Stop Built-in Fan (On & Off) Built-in Fan Current or Power Sensors Connections for ADS & FPS units Connections to Remote Emergency Stop Connections to Fire Alarm Panel Anti-Back Pressure Feature Audible Alarm M-G01N 4 4 4 4 M-G02 4 4 4 4 M-G02R 4 4 4 4 4 M-G03R 4 4 4 4 4 M-G06R 4 4 4 4 Integral to unit 4 4 4 4 IMPORTANT INFORMATION The Mechline GIS module is one key component in a safety system, interfaced with a number of other control mechanisms. The Gas Interlock System will ensure safety in the event of a failure of any of these other interconnected elements and a shutdown of the gas supply to the kitchen may result, requiring immediate engineer attendance. To minimise disruption to kitchen operations, it is highly recommended that you have or provide your client with an emergency contact number for your service/installation engineer. Alternatively, advise your client in advance of other back-up procedures in the event of product activation or operational difficulties. If on-site emergency call-out cover is required, it is not the responsibility of Mechline Developments Ltd. to provide this. The warranty on the Mechline GIS is for 12 months from the date of invoice. The warranty is for parts only, against manufacturing defect or workmanship. No inclusion is made for labour or site attendance, and no such warranty is offered or implied. Mechline Developments Ltd accepts no responsibility for consequential loss caused or suffered as a result of the lack of provision of on-site emergency cover. It is the customer s responsibility to determine the suitability of the GIS system for the application. For Mechline s Standard Warranty and Returns Policy - see the back of this catalogue. Important documents / notes for your consideration and reference: TB 123 Gas Safe Register Gas Safety (Installation and Use) Regulations 1998 GSIUR 27/4 - ACOP L56 Rev 14 08/13 HSE CAIS 23 (Revision 2, 07/13. Gas Safety in Catering & Hospitality) HSE CAIS 10 (Revision 2, 07/12. Ventilation in Catering Kitchens) HVCA Guidance - DW 172 Standard for Kitchen Ventilation Systems IGEM/UP/19 Design and application of interlock devices Visit www.mechline.com for more information. Call us on: +44 (0) 1908 261511 Send enquiries to: info@mechline.com Email orders to: orders@mechline.com www.mechline.com 131

GREASE TRAPS ARE NOT THE ONLY SOLUTION to keep kitchen drains clear of fats, oils & grease S unique formula makes it the MOST POWERFUL product on the market. Permanently breaking down Fats, Oils, Grease [FOGs] and starches in the drain so they can never reform or solidify. Can work legally with grease traps or on its own. A maintenance-free and environmentally friendly solution. Easy to locate in the most difficult situations. THINK. It ticks all the right boxes... CHECKLIST FOR KEEPING KITCHEN DRAINS CLEAR Meets building regulations. Legally compliant. On Water Companies products list. BBA approved. Easy to locate, install and operate. 3 33 3 3 Visit: www.greasepak.com for more information and to download a copy of the British Water Code Of Practice. NB: Product accreditation may not apply to all products in the relevant range. Please contact Mechline to confirm. Unless otherwise stated, all products carry a warranty of twelve (12) months against manufacturing defect or workmanship on parts. GreasePak TM is manufactured in Britain by Mechline Developments Ltd. No inclusion is made for labour or site attendance. Dimensions shown in mm unless otherwise stated. Information and numerical data has been prepared as a general guide to the products but intending buyers & users must satisfy themselves as to the suitability and safety of the products for their particular purposes & duties. The WRAS Approved Product logo is a certification mark which is owned by WRAS Ltd.