(Non-Inverter & Inverter) R410A

Similar documents
LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG AIR CONDITIONERS 2013 Ducted Split System

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

LG AIR CONDITIONERS Ducted Split System. Clean, Quiet & Comfortable with LG HVAC.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

With LG HVAC, It's all Possible

Energy-saving operation

Inverter Wall Mounted Series

Air Conditioner CONTENTS

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Light commercial range. Passion at work

Residential and Light Commercial Ductless Systems Catalog

AIR CONDITIONING REVERSE-CYCLE INVERTER

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

LG Commercial Air Conditioners. Wide Range Free Combination with Various Indoor Types 24/7.0 18/5.3 12/3.5 9/2.6 7/2.1 5/

Air Conditioning System

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

A single answer for multiple zones.

Inverter Ducted Air Conditioners

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

Ductless Split Systems Ceiling Cassette Heat Pumps

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

Ducted inverter reverse cycle air conditioning

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Inverter Ducted XPower 42QSS

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

Inverter Ducted Air Conditioners

A single answer for multiple zones.

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

Ductless Split Systems Concealed Duct Heat Pumps

About Daikin: WARNINGS:

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Just feel well. 2017/2018 Air conditioning

Inverter Wall Mounted

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

LG VRF Systems. Air Conditioning Technologies

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

Inventor of the Inverter Digital Inverter System

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Compact design & easy maintenance

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Learn more about Samsung air conditioner at:

Lennox Mini-Split Systems Year-Round Comfort and Performance

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Easy to service. Up to 9 indoor units can be connected

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

SVC Manual(Exploded View)

Ducted Air Conditioning

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Air Conditioner SVC MANUAL(Exploded View)

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

Samsung Free Joint Multi Air Conditioning System

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

AIR CONDITIONING REVERSE-CYCLE INVERTER

Ducted Air Conditioning

Now with WiFi as standard Find out more at

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Pure Efficiency Meets Healthy Living NEW 2013

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

Ultimate VRF System R410A, 50Hz

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

2 &3-4 Head Multi System

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

for Light Commercial Use

Ductless Mini-Split Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2015

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Wall Mounted Split Systems

LG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

2016 RESIDENTIAL AIR CONDITIONERS

Transcription:

LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved.

Non-Inverter Single Split Line-up R410A 1 3 Capacity (Btu/h) 9,000 12,000 18,000 24,000 Capacity (Btu/h) 30,000 36,000 42,000 48,000 54,000 Power Supply 1 220-240V 50Hz Power Supply 3 380-415V 50Hz Outdoor Unit Outdoor Unit Indoor Unit Indoor Unit Cassette Cassette Floor Standing Floor Standing Concealed Duct Concealed Duct 02 2015 LG Air Conditioners 03

Inverter Single Split Line-up R410A 1 3 Capacity (Btu/h) 9,000 12,000 18,000 24,000 Capacity (Btu/h) 30,000 36,000 42,000 48,000 53,900 Power Supply 1 220-240V 50Hz Power Supply 3 380-415V 50Hz Outdoor Unit Outdoor Unit Indoor Unit Indoor Unit Cassette Cassette Low Static (Set) Low Static (Set) Concealed Duct (Low Static) Concealed Duct (High Static) Concealed Duct (Middle Static) Floor Standing 04 2015 LG Air Conditioners 05

Cassette [ Non-Inverter ] Compact Size The indoor unit with slim and compact dimensions has reduced the restriction which enables successful installation in various spaces. Length width : 840X840mm Cassette Indoor Unit Height 18~30 kbtu 204mm 36 kbtu 246mm 48~54 kbtu 288mm High Mode High ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor. High Mode 4.2 General 2.7 3 4 (mm) 2.4 2 2 1 1 4 3 2 1 0 1 2 3 4 06 2015 LG Air Conditioners 07

Piping check check corner design Drain leakage check Refrigant Piping check Attachable/detachable corner design Wide Jet Air Flow Convenient Panel Installation Improved vanes reduce the curved area and provide even distribution. The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain Detachable connection pipe. Detachable Corner Design Corner Design Drain Leakage Check Hanger Adjust Detachable Corner Design m 80Wm iiddeerr t 26 27 C W mm 567 Air flow dead zone in 4 corners m 487m Refrigant Piping check 25 24 23 22 21 20 19 15 C 18 Even air distribution t 26 27 C 25 24 23 22 21 20 19 15 C 18 Independent Vane Operation Refrigant Piping check piping check and hanger adjust Drain leakagedrain leakage Drain leakage check check Hanger adjust check and hanger adjust Drain Leakage Check Hanger Adjust Drain Leakage Check Leakage It is easy to install the panel to the body, using the button Drain type panel design. Check Hanger Adjust Hanger Adjust Auto Elevation Grille The independent vane operation feature uses separate motors, making it possible to control all four vanes independently. Independent Vane Control 4-Point Support Structure Auto Leveling Memory for User s Level Auto Stop Detection Indirect air flow STOP Memory Max. 4.5m Direct air flow Easy filter cleaning with elevation grill. * Operating with wired remote controller PQRCVSL0(QW) and wireless remote controller included in PTEGM0. * Wired remote controller PQRCVSL0(QW) applied 08 * Applied to cassette panel PT-UMC1 2015 LG Air Conditioners 09 Inverter Single Split LG Cassette All Vane Operation Drain leakage check Refrigant Piping check Non-Imverter Single Split

Quite Operation with 3D Fan New technology of 3D fan is applied to H-Inverter cassettes 10~14kW. It increases air flow but reduces noise. Prevent Pollution New Blade Angle Changed : Increase air flow and decrease noise Curved Leading Edge : Improve air flow in same RPM of conventional fans Coanda design of air outlet can prevent contamination of ceiling. Product Louver Pollutions 47dB(A) * H-Inverter Cassette 10kW Product Louver 3dB(A) Coanda Design 44dB(A) New 1 Cassette Non-Inverter Indoor ATNC186PLE0 ATNC246PLE0 Capacity Cooling Rated kw 5.27 7.03 Btu/h 18,000 24,000 EER Cooling Rated kw 9.5 9.8 Power Supply ø/v/hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W*H*D mm 840 204 840 840 204 840 Net Weight Net kg (lbs) 19.6 (43.2) 19.6 (43.2) Type - Turbo Fan Turbo Fan Fan H/M/L m 3 /min 17.0 / 15.0 / 13.0 18.0 / 16.0 / 14.0 Air Flow Rate H/M/L ft 3 /min 600 / 530 / 459 636 / 565 / 494 Sound Pressure Level H/M/L db(a) 36 / 34 / 32 40 / 38 / 36 Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 32.0(1-1/4) / 25.0(31/32) Ø 32.0(1-1/4) / 25.0(31/32) Model PT-UMC1 PT-UMC1 Decoration Panel Dimensions W*H*D mm 950 25 950 950 25 950 inch 37-13/32 x 31/32 x 37-13/32 37-13/32 x 31/32 x 37-13/32 Net Weight kg (lbs) 5.0 (11.0) 5.0 (11.0) Outdoor ATUC186PLE0 ATUC246PLE0 Power Input Cooling Rated kw 1.89 2.45 Running Current Cooling Rated A 8.60 11.00 Power Supply V/ø/Hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions W*H*D mm 870 655 320 870 655 320 Net Weight kg (lbs) 42.0 (92.6) 53.0 (116.8) Compressor Type - Rotary Twin Rotary Type - R410A R410A Precharged Amount g(oz) 800 (28.2) 1,120 (39.5) Additional Charging Volume g/m(oz/ft) 20 (0.22) 20 (0.22) Control - Capillary Tube Capillary Tube Fan Air Flow Rate m³/minxno. 50 x 1 50 x 1 Sound Pressure Level Cooling Rated db(a) 56 58 Piping Connections Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Piping Length Max. m(ft) 30 (98.4) 30 (98.4) Maximum Height Difference IDU-ODU Max. m(ft) 20 (65.6) 20 (65.6) Operation Range Cooling Min~Max. C DB( F DB) 21 (69.8) ~ 46 (114.8) 21 (69.8) ~ 46 (114.8) * Cooling Temperature : Indoor 27 C(80.6 F) DB / 19 C(66.2 F) WB Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB 18k, 24k 10 2015 LG Air Conditioners 11

3 3 Cassette Non-Inverter Indoor ATNC308PLE0 ATNC368NLE0 Capacity Cooling Rated kw 7.91 10.55 Btu/h 27,000 36,000 EER Cooling Rated kw 9.0 9.6 Power Supply ø/v/hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W*H*D mm 840 204 840 840 246 840 Net Weight Net kg (lbs) 20.5 (45.2) 22.0 (48.5) Type - Turbo Fan Turbo Fan Fan H/M/L m 3 /min 18.0 / 16.0 / 14.0 25.0 / 23.0 / 21.0 Air Flow Rate H/M/L ft 3 /min 636 / 565 / 494 883 / 812 / 742 Sound Pressure Level H/M/L db(a) 40 / 38 / 36 46 / 44 / 42 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 32.0(1-1/4) / 25.0(31/32) Ø 32.0(1-1/4) / 25.0(31/32) Model PT-UMC1 PT-UMC1 Decoration Panel Dimensions W*H*D mm 950 25 950 950 25 950 inch 37-13/32 x 31/32 x 37-13/32 37-13/32 x 31/32 x 37-13/32 Net Weight kg (lbs) 5.0 (11.0) 5.0 (11.0) Outdoor ATUC308PLE0 ATUC368NLE0 Power Input Cooling Rated kw 3.00 3.75 Running Current Cooling Rated A 5.50 6.70 Power Supply V/ø/Hz 380-415 / 3 / 50 380-415 / 3 / 50 Dimensions W*H*D mm 870 808 320 950 834 330 Net Weight kg (lbs) 59.0 (130.1) 76.0 (167.6) Compressor Type - Twin Rotary Scroll Type - R410A R410A Precharged Amount g(oz) 1,300 (45.9) 1,400 (49.4) Additional Charging Volume g/m(oz/ft) 20 (0.22) 25 (0.27) Control - Capillary Tube Capillary Tube Fan Air Flow Rate m³/minxno. 50 x 1 50 x 1 Sound Pressure Level Cooling Rated db(a) 58 63 Piping Connections Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Piping Length Max. m(ft) 50 (164.0) 50 (164.0) Maximum Height Difference IDU-ODU Max. m(ft) 30 (98.4) 30 (98.4) Operation Range Cooling Min~Max. C DB( F DB) 21 (69.8) ~ 46 (114.8) 21 (69.8) ~ 46 (114.8) 30k 36k Cassette Non-Inverter Indoor ATNC488MLE0 ATNC548MLE0 Capacity Cooling Rated kw 14.10 15.24 Btu/h 48,000 52,000 EER Cooling Rated kw 9.5 9.0 Power Supply ø/v/hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W*H*D mm 840 288 840 840 288 840 Net Weight Net kg (lbs) 28.0 (61.7) 28.0 (61.7) Type - Turbo Fan Turbo Fan Fan H/M/L m 3 /min 29.0 / 27.0 / 25.0 32.0 / 30.0 / 28.0 Air Flow Rate H/M/L ft 3 /min 1,024 / 954 / 883 1,130 / 1,160 / 989 Sound Pressure Level H/M/L db(a) 46 / 44 / 42 46 / 44 / 42 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 32.0(1-1/4) / 25.0(31/32) Ø 32.0(1-1/4) / 25.0(31/32) Model PT-UMC1 PT-UMC1 Decoration Panel Dimensions W*H*D mm 950 25 950 950 25 950 inch 37-13/32 x 31/32 x 37-13/32 37-13/32 x 31/32 x 37-13/32 Net Weight kg (lbs) 5.0 (11.0) 5.0 (11.0) Outdoor ATUC488MLE0 ATUC548MLE0 Power Input Cooling Rated kw 5.05 5.80 Running Current Cooling Rated A 8.90 10.00 Power Supply V/ø/Hz 380-415 / 3 / 50 380-415 / 3 / 50 Dimensions W*H*D mm 900 370 1,160 900 370 1,160 Net Weight kg (lbs) 96.0 (211.6) 96.0 (211.6) Compressor Type - Scroll Scroll Type - R410A R410A Precharged Amount g(oz) 2,500 (88.2) 2,250 (79.4) Additional Charging Volume g/m(oz/ft) 25 (0.27) 25 (0.27) Control - Capillary Tube Capillary Tube Fan Air Flow Rate m³/minxno. 50 x 2 50 x 2 Sound Pressure Level Cooling Rated db(a) 59 61 Piping Connections Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Piping Length Max. m(ft) 50 (164.0) 50 (164.0) Maximum Height Difference IDU-ODU Max. m(ft) 30 (98.4) 30 (98.4) Operation Range Cooling Min~Max. C DB( F DB) 21 (69.8) ~ 46 (114.8) 21 (69.8) ~ 46 (114.8) 48k, 54k * Cooling Temperature : Indoor 27 C(80.6 F) DB / 19 C(66.2 F) WB Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB * Cooling Temperature : Indoor 27 C(80.6 F) DB / 19 C(66.2 F) WB Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB 12 2015 LG Air Conditioners 13

Floor Standing [ Non-Inverter ] Anti-Bacteria Filter It removes dust in the air as well as bacteria proliferation, making the indoor atmosphere healthy Odour Auto Operation (Neuro Fuzzy Control) According to the temperature, air volume and air velocity, the controller will automatically adjust the unit to create the most pleasant atmosphere. Neuro Fuzzy Control Like human sense To sence indoor temperature, humidity and room size Like human brain To create optimal cooling condition Like human judgement To control cooling temperature Like feeling in the deep forest To reaiize comfortable, heaithful, low noisey and enegy saving cooling Hot Start Function (Heat Pump Model Only) During starting of the unit in the heating mode it prevents cold air blown from the unit. It starts the indoor fan only after indoor unit pipe temperature reaches a preset value(28 C). When indoor unit pipe temperature has reached 28 C, then for initial 1 minute the indoor fan runs at low speed and after that at the set fan speed. 14 2015 LG Air Conditioners 15

Auto Restart Function In case of a sudden power failure, this feature will automatically restore the A/C to its previous settings when power returns. Self Diagnosis Function The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event a malfunction, the LED on the unit illuminates representing the related error code. Auto Swing Function LG Floor Standing type is provided auto swing louver that vertically spreads a comfortable air blow. Energy Saving Gold Fin (Optional) LG s Outdoor Heat Exchanger is coated with a gold-colored anti-corrosive epoxy treatment on the aluminum coil, to prevent corrosion. This maintains excellent heat transfer properties of the coil for an extended time, whereas non-gold Fin coils progressively lose efficiency due to surface corrosion. Gold Fin fin is perfect for areas with high pollution or locations exposed to saltwater spray from the sea. Operation LG Gold Fin Auto Restart System Power Failure Stop Setting stored before power failure. EEP-ROM VS Power Resume Salt Spray Test for 15 Days LG Gold Fin LG Gold Fin protected Aluminum Corrosion Resistance Uncoated Aluminum Gold Fin is long lasting, durable and makes the Outdoor Unit look prestigious. Restart Starting to corrode Uncoated Aluminum 1 & 3 Floor Standing Non-Inverter Indoor APNC246KLA0 APNC308KLA0 APNC488TLA0 Capacity Cooling Rated kw 7.03 7.91 13.48 Btu/h 24,000 27,000 46,000 EER Cooling Rated kw 9.09 9.61 8.98 Power Supply ø/v/hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W*H*D mm 500 1,800 320 500 1,800 320 590 1,850 470 Net Weight Net kg (lbs) 33.0 (72.8) 33.0 (72.8) 55.0 (121.3) Type - Sirocco Sirocco Sirocco Fan H/M/L m 3 /min 21.0 / 19.0 / - / 15.0 21.0 / 19.0 / - / 15.0 30.0 / 28.0 / - / 26.0 Air Flow Rate H/M/L ft 3 /min 742 / 671 / - / 530 742 / 671 / - / 530 1,059 / 989 / - / 918 Sound Pressure Level H/M/L db(a) 51 / 50 / - / 44 51 / 50 / - / 44 55 / 52 / - / 49 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 16 Ø 16 Ø 16 Decoration Panel No.xmm 2 4C x 0.75 4C x 0.75 4C x 0.75 Outdoor APUC246KLA0 APUC308KLA0 APUC488TLA0 Power Input Cooling Rated kw 2.64 2.81 5.12 Running Current Cooling Rated A 12 5.3 8.9 Power Supply V/ø/Hz 220-240 / 1 / 50 380-415 / 3 / 50 380-415 / 3 / 50 Wiring Connections Power Supply Cable(included Earth) No.xmm 2 3C x 2.5 (12) 5C x 2.5 (12) 5C x 2.5 (12) Dimensions W*H*D mm 870 655 320 870 808 320 950 834 330 Net Weight kg (lbs) 53.0 (116.8) 59.0 (130.1) 76.0 (167.6) Compressor Type - Twin Rotary Twin Rotary Scroll Type - R410A R410A R410A Precharged Amount g(oz) 1,300 (45.9) 1,300 (45.9) 2,100 (74.1) Chargeless-Pipe Length m(ft) 7.5 (24.6) 7.5 (24.6) 7.5 (24.6) Additional Charging Volume g/m(oz/ft) 25 (0.27) 25 (0.27) 25 (0.27) Control - Capillary Tube Capillary Tube Capillary Tube Heat Exchanger (Row x Column x Fins per inch) x No. - (2 x 30 x 21) x 1 (2 x 38 x 21) x 1 (3 x 40 x 21) x 1 Fan Air Flow Rate m³/minxno. 50 x 1 50 x 1 55 x 1 Sound Pressure Level Rated db(a) 58 58 56 Sound Power Level Max. db(a) 0 - - Piping Connections Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) Piping Length Max. m(ft) 30 (98.4) 50 (164.0) 50 (164.0) Maximum Height Difference IDU-ODU Max. m(ft) 20 (65.6) 30 (98.4) 30 (98.4) Operation Range Cooling Min~Max. C DB( F DB) (21.0) ~ (46.0) (21.0) ~ (46.0) (21.0) ~ (46.0) * Cooling Temperature : Indoor 27 C(80.6 F) DB / 19 C(66.2 F) WB Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB 24k, 30k 48k 16 2015 LG Air Conditioners 17

CEILING CONCEALED DUCT [ Non-Inverter ] *E.S.P: External Static Pressure The air volume and sound level is kept constant as designed regardless of changes in E.S.P.(External Static Pressure) E.S.P. Technology - Optimizes Duct Installation - Keeps Capacity & Sound Levels within desired ranges - Reduces the number of models control motor technology reduces installation costs. The desired air flow is obtained by adjusting the phase motor during installation of the product, giving you more flexibility when setting up your duct system. The E.S.P can be adjusted linearly from 0 to 10mmAq. Long Distance & High Elevation Pipe This ceiling concealed duct can be installed at long distance andhigh height differences from the outdoor as per below table. High Head Drain Pump Auxiliary Drain Pump automatically drains water. A standard drain-head height of up to 700mm is possible, creating the ideal solution for perfect water drainage. (Accessory:ABDPG) 700mm Drain Pipe Slope (1/50~1/100) 300mm Flexible Drain Hose Two Thermistor Control Fixture Drain pipe 450mm There may be a significant difference between the temperature taken at the installed product and indoor temperature. Two thermistor control provides option to control temperature by referring any of the two temperature. With the help of the slide switch at the back of the LCD wired remote controller, selection of the desired thermistor for controlling the unit can be done. One thermistor is in the Indoor unit & the other one is in the LCD wired remote. Two Thermistor Control Length Elevation LCD wired r e m o t e controller Concealed Duct * Only 42k, 54k (m) Capacity Max Length Max Elevation 9,000~12,000Btu 15m 7m 18,000~24,000Btu 30m 20m 30,000~54,000Btu 50m 30m Quiet Operation & Easy Service A lightweight plastic blower and housing makes air conditioning operation quiet and backup servicing more convenient. The new fan housing can be easily dismantled for convenient servicing and maintenance. The fan motor can be removed without the need to remove the complete fan direct assembly. 18 2015 LG Air Conditioners 19

1 1 CONCEALED DUCT I Low Static Non-Inverter Indoor ABNC096TLA0 ABNC126TLA0 Capacity Cooling Rated kw 2.9 3.5 Btu/h 10,000 12,000 EER Cooling Rated kw 8.3 9.6 Power Supply ø/v/hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W*H*D mm 650 230 535 650 230 535 Net Weight Net kg (lbs) 25.0 (55.1) 25.0 (55.1) Fan Type - Sirrocco Fan Sirrocco Fan Air Flow Rate H/M/L m 3 /min 9 / 8 / 7 9 / 8 / 7 External Static Pressure mmaq 0 0 Sound Pressure Level H/M/L db(a) 42 / 40 / 38 42 / 40 / 38 Liquid mm(inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Piping Connection Gas mm(inch) Ø 12.7 (1/2) Ø 12.7 (1/2) Drain O.D./I.D. mm Ø 25.4 / 20.4 Ø 25.4 / 20.4 Outdoor ABUC096TLA0 ABUC126TLA0 Power Input Cooling Rated kw 1,200 1,250 Running Current Cooling Rated A 6.0 6.0 Power Supply V/ø/Hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions W*H*D mm 770 540 285 770 540 285 Net Weight kg (lbs) 30.0 (66.1) 30.0 (66.1) Compressor Type - Rotary Rotary Type - R410A R410A Precharged Amount g(oz) 680 (24.0) 680 (24.0) Additional Charging Volume g/m(oz/ft) 20 (0.22) 20 (0.22) Control - Capillary Tube Capillary Tube Fan Air Flow Rate m³/minxno. Axial Fan Axial Fan Sound Pressure Level Cooling Rated db(a) 53 53 Piping Connections Liquid mm(inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Gas mm(inch) Ø 12.7 (1/2) Ø 12.7 (1/2) Piping Length Max. m(ft) 15 (49.2) 15 (49.2) Maximum Height Difference IDU-ODU Max. m(ft) 7 (23.0) 7 (23.0) Operation Range Cooling Min~Max. C DB( F DB) 21 (69.8) ~ 46 (114.8) 21 (69.8) ~ 46 (114.8) 9k, 12k CONCEALED DUCT I Medium Static Non-Inverter Indoor ABNC186HLA0 ABNC246HLA0 Capacity Cooling Rated kw 5.3 6.7 Btu/h 18,000 23,000 EER Cooling Rated kw 10.0 8.6 Power Supply ø/v/hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W*H*D mm 882 260 450 882 260 450 Net Weight Net kg (lbs) 28.0 (61.7) 28.0 (61.7) Fan Type - Sirrocco Fan Sirrocco Fan Air Flow Rate H/M/L m 3 /min 16 / 14.5 / 13 18 / 16.5 / 14 External Static Pressure mmaq 6 6 Sound Pressure Level H/M/L db(a) 41 / 39 / 38 44 / 42 / 41 Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 25.4 / 20.4 Ø 25.4 / 20.4 Outdoor ABUC186HLA0 ABUC246HLA0 Power Input Cooling Rated kw 1,800 2,660 Running Current Cooling Rated A 8.6 12.0 Power Supply V/ø/Hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions W*H*D mm 870 655 320 870 655 320 Net Weight kg (lbs) 42.0 (92.6) 53.0 (116.8) Compressor Type - Rotary Rotary Type - R410A R410A Precharged Amount g(oz) 900 (31.7) 1,100 (38.8) Additional Charging Volume g/m(oz/ft) 20 (0.22) 20 (0.22) Control - Capillary Tube Capillary Tube Fan Air Flow Rate m³/minxno. Axial Fan Axial Fan Sound Pressure Level Cooling Rated db(a) 56 60 Piping Connections Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Piping Length Max. m(ft) 30 (98.4) 30 (98.4) Maximum Height Difference IDU-ODU Max. m(ft) 20 (65.6) 20 (65.6) Operation Range Cooling Min~Max. C DB( F DB) 21 (69.8) ~ 46 (114.8) 21 (69.8) ~ 46 (114.8) 18k, 24k * Cooling Temperature : Indoor 27 C(80.6 F) DB / 19 C(66.2 F) WB Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB * Cooling Temperature : Indoor 27 C(80.6 F) DB / 19 C(66.2 F) WB Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB 20 2015 LG Air Conditioners 21

3 3 CONCEALED DUCT I Medium Static Non-Inverter 30k 36k, 42k Indoor ABNC308GLA0 ABNC368GLA0 ABNC428GLA0 Capacity Cooling Rated kw 7.9 10.7 12.3 Btu/h 27,000 36,500 42,000 EER Cooling Rated kw 9.5 9.0 9.5 Power Supply ø/v/hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W*H*D mm 1,180 x 300 x 450 1,180 x 300 x 450 1,180 x 300 x 450 Net Weight Net kg (lbs) 38.0 (83.8) 38.0 (83.8) 38.0 (83.8) Fan Type - Sirrocco Fan Sirrocco Fan Sirrocco Fan Air Flow Rate H/M/L m 3 /min 28 / 26 / 24 32.5 / 29 / 26.5 32.5 / 29 / 26.5 External Static Pressure mmaq 8 8 8 Sound Pressure Level H/M/L db(a) 44 / 42 / 40 45 / 43 / 41 45 / 43 / 41 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 25.4 / 20.4 Ø 25.4 / 20.4 Ø 25.4 / 20.4 Outdoor ABUC308GLA0 ABUC368GLA0 ABUC428GLA0 Power Input Cooling Rated kw 2,840 4,050 4,400 Running Current Cooling Rated A 5.4 7.0 7.0 Power Supply V/ø/Hz 380-415 / 3 / 50 380-415 / 3 / 50 380-415 / 3 / 50 Dimensions W*H*D mm 870 808 320 950 834 330 950 834 330 Net Weight kg (lbs) 59.0 (130.1) 84.0 (185.2) 84.0 (185.2) Compressor Type - Rotary Scroll Scroll Type - R410A R410A R410A Precharged Amount g(oz) 1,500 (52.9) 1,800 (63.5) 1,800 (63.5) Additional Charging Volume g/m(oz/ft) 25 (0.27) 25 (0.27) 25 (0.27) Control - Capillary Tube Capillary Tube Capillary Tube Fan Air Flow Rate m³/minxno. Axial Fan Axial Fan Axial Fan Sound Pressure Level Cooling Rated db(a) 58 63 63 Piping Connections Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) Piping Length Max. m(ft) 50 (164.0) 50 (164.0) 50 (164.0) Maximum Height Difference IDU-ODU Max. m(ft) 30 (98.4) 30 (98.4) 30 (98.4) Operation Range Cooling Min~Max. C DB( F DB) 21 (69.8) ~ 46 (114.8) 21 (69.8) ~ 46 (114.8) 21 (69.8) ~ 46 (114.8) CONCEALED DUCT I Medium Static Non-Inverter Indoor ABNC488RLA0 ABNC548RLA0 Capacity Cooling Rated kw 14.1 15.5 Btu/h 48,000 53,000 EER Cooling Rated kw 9.4 9.1 Power Supply ø/v/hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W*H*D mm 1,230 380 590 1,230 380 590 Net Weight Net kg (lbs) 52.0 (114.6) 52.0 (114.6) Fan Type - Sirrocco Fan Sirrocco Fan Air Flow Rate H/M/L m 3 /min 40 / 35 / 30 45 / 40 / 35 External Static Pressure mmaq 10 10 Sound Pressure Level H/M/L db(a) 49 / 47 / 45 51 / 49 / 47 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 19.05 (3/4) Drain O.D./I.D. mm Ø 25.4 / 20.4 Ø 25.4 / 20.4 Outdoor ABUC488RLA0 ABUC548RLA0 Power Input Cooling Rated kw 5,100 5,800 Running Current Cooling Rated A 9.3 10.0 Power Supply V/ø/Hz 380-415 / 3 / 50 380-415 / 3 / 50 Dimensions W*H*D mm 900 1,160 370 900 1,160 370 Net Weight kg (lbs) 95.0 (209.4) 95.0 (209.4) Compressor Type - Scroll Scroll Type - R410A R410A Precharged Amount g(oz) 2,400 (84.7) 2,400 (84.7) Additional Charging Volume g/m(oz/ft) 30 (0.32) 30 (0.32) Control - Capillary Tube Capillary Tube Fan Air Flow Rate m³/minxno. Axial Fan Axial Fan Sound Pressure Level Cooling Rated db(a) 59 61 Piping Connections Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 19.05 (3/4) Piping Length Max. m(ft) 50 (164.0) 50 (164.0) Maximum Height Difference IDU-ODU Max. m(ft) 30 (98.4) 30 (98.4) Operation Range Cooling Min~Max. C DB( F DB) 21 (69.8) ~ 46 (114.8) 21 (69.8) ~ 46 (114.8) 48, 54k * Cooling Temperature : Indoor 27 C(80.6 F) DB / 19 C(66.2 F) WB Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB * Cooling Temperature : Indoor 27 C(80.6 F) DB / 19 C(66.2 F) WB Outdoor 35 C(95 F) DB / 24 C(75.2 F) WB 22 2015 LG Air Conditioners 23

Why LG Inverter Single Split? Recognizing the importance of saving energy, LG has taken the initiative to develop new, more efficient inverter technology. In addition to consuming less electricity, the company s advanced inverter systems also boast powerful performance and enhanced reliability. LG s Inverter Single Split lowers energy usage and operational costs, illustrating how clever technology can make a real difference. Designed for commercial spaces such as offices and retail stores, the new model can operate for extended periods of time, while also providing exceptional energy efficiency. The Inverter Single Split is able to produce an impressive volume of cool air; helping to create the perfect indoor temperature in almost no time at all. As well as delivering fast and efficient cooling, LG s latest solution can also minimize electricity consumption by as much as 25 percent. Comfortable Operation Once the desired temperature is achieved, unlike conventional air conditioners that turn the compressor on and off, LG inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with minimal fluctuation to ensure that your comfort is not compromised. Setting Temprature Temprature Room Temprature Power On Power Off Time Setting Temprature Temprature Room Temprature Power On LG Inverter 24 2015 LG Air Conditioners 25

Excellent Energy Saving LG s advanced inverter technology leads to powerful performance while minimizing energy consumption. It will bring you greater cost saving over the product life time. Cassette (kwh) 5,000 4,000 3,000 2,000 1,000 EER 3.65 World Top Class Annual Power Consumption 5,456 39% 3,331 World Top Class 3.65 Duct EER EER 3.23 World Top Class Annual Power Consumption (kwh) 5,592 5,000 4,000 3,764 3,000 2,000 1,000 33% Quick Cooling Advanced VRF technology Refrigerent Pressure Control is applied, which ensures faster and more accurate operation of compressor to the optimum cooling condition. LG Inverter Temperature Sensor Only Temperature Sensor Pressure Sensor Step 1 Sensing current temperature of refrigerent, indoor and outdoor temperature Step 1 Sensing refrigerent pressure and temperature simultaneously to make sure compressor ready for target cooling operation Shorten Time to Reach Setting Temprature It takes up to 30% less time to reach the desired temperature with a high level of accuracy and stability. 30% Quicker Step 2 Estimating Pressure Finding recorded target pressure to operate compressor, based on the corresponding temperature data This ensures to reach target performance point without failing to keep a reliable operation. Temperature This algorithm is more likely to be affected by temperature change and it takes more time to calculate proper operation range of compressor to target point. Direct Sensing 30% LG Inverter LG Inverter Setting Temperature Convertible Floor standing EER 3.30 EER 3.18 Wide Operating Range LG Inverter Time World Top Class Annual Power Consumption (kwh) 10,000 7,394 8,000 6,000 4,000 40% 4,402 World Top Class Annual Power Consumption (kwh) 9,387 10,000 8,000 6,000 4,000 28% 6,766 More accurate control of compressor operation from pressure sensing mechanism ensures stable performance against extreme outdoor conditions. + Cooling Operation Range: -5 C ~ 48 C 20 C 48 43 10-5 Cooling Operation Cooling Operation 5 º c 15 º c 2,000 2,000 LG Inverter LG Inverter LG Inverter Time 26 2015 LG Air Conditioners 27

Mogul trailing edge Quiet Operation LG s unique outdoor fan and BLDC motor eliminates unnecessary noise and allows smooth operation. Additionally, night silence mode can make more silent environment for you. Improved Outdoor Fan Narrow hub blade & mogul trailing edge of Type 1 and thick leading edge & saw shaped trailing edge in Type 2 fan improve operation with low noise level and high air flow rate. 526mm Reverse hub 460mm Leading edge thickening Saw tooth trailing edge 50dB Talking 52dB LG BLDC Fan Motor Air Conditioner * Based on 30kBtu Outdoor unit sound pressure BLDC Fan Motor BLDC Fan Motor 55dB Office 78dB Typing With strong torque and powerful ND magnetism inside the motor, the BLDC motor provides large air volume and high static pressure. Precise speed control makes operation smoother. Both electrical and mechanical noise is lower, and high speed operation is achieved. Easy Installation By reducing volume of outdoor unit to one fan type, without compromising performance and efficiency, it ensures to save more space and make installation easier. * Two-fan outdoor type is only applied to 54K Btu unit. Compact Outdoor Unit 834 mm Height 834mm 67kg Weight 67Kg 96kg 1380 mm Narrow hub blade Type 1 Type 2 * Applied to 8.2kW, 10.0kW, 13.5kW, and 15.8kW unit * Applied to 5.3kW and 7.0kW unit Long and High Elevation Piping Night Silent Operation Total piping 50m and Elevation length 30m provides flexibility for various condition and easy installation. Outdoor unit Night Silent operating can reduce noise levels at night time by simply setting the dip switch on the PCB of the outdoor unit. Capacity Cooling Mode 3dB(A) 6dB(A) Load Sound Level Night Total piping lengh 50m Indoor unit Elevation lengh 30m Step 1 Step 2 Day 8 Hours 8 Hours Day Day Time Nigh Time Highest Outdoor Temperature Mode Start Mode End Time * Based on 30~54kBtu models 28 2015 LG Air Conditioners 29

Cassette [ Inverter ] Compact Size The indoor unit with slim and compact dimensions has reduced the restriction which enables successful installation in various spaces. Length width : 840X840mm Standard Inverter Height 18~36kBtu 204mm 48~54kBtu 288mm High Mode High ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor. High Mode 4.2 General 2.7 3 4 (mm) 2.4 2 2 1 1 4 3 2 1 0 1 2 3 4 30 2015 LG Air Conditioners 31

Piping check check corner design Drain leakage check Refrigant Piping check Attachable/detachable corner design Wide Jet Air Flow Convenient Panel Installation Improved vanes reduce the curved area and provide even distribution. The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain Detachable connection pipe. Detachable Corner Design Corner Design Drain Leakage Check Hanger Adjust Detachable Corner Design m 80Wm iiddeerr t 26 27 C W mm 567 Air flow dead zone in 4 corners m 487m Refrigant Piping check 25 24 23 22 21 20 19 15 C 18 Even air distribution t 26 27 C 25 24 23 22 21 20 19 15 C 18 Independent Vane Operation Refrigant Piping check piping check and hanger adjust Drain leakagedrain leakage Drain leakage check check Hanger adjust check and hanger adjust Drain Leakage Check Hanger Adjust Drain Leakage Check Leakage It is easy to install the panel to the body, using the button Drain type panel design. Check Hanger Adjust Hanger Adjust Auto Elevation Grille The independent vane operation feature uses separate motors, making it possible to control all four vanes independently. Independent Vane Control 4-Point Support Structure Auto Leveling Memory for User s Level Auto Stop Detection Indirect air flow STOP Memory Max. 4.5m Direct air flow Easy filter cleaning with elevation grill. * Operating with wired remote controller PQRCVSL0(QW) and wireless remote controller included in PTEGM0. * Wired remote controller PQRCVSL0(QW) applied 32 * Applied to cassette panel PT-UMC1 2015 LG Air Conditioners 33 Inverter Single Split LG Cassette All Vane Operation Drain leakage check Refrigant Piping check Non-Imverter Single Split

Quite Operation with 3D Fan New technology of 3D fan is applied to H-Inverter cassettes 10~14kW. It increases air flow but reduces noise. Prevent Pollution New Blade Angle Changed : Increase air flow and decrease noise Curved Leading Edge : Improve air flow in same RPM of conventional fans Coanda design of air outlet can prevent contamination of ceiling. Product Louver Pollutions 47dB(A) * H-Inverter Cassette 10kW Product Louver 3dB(A) Coanda Design 44dB(A) New 1 Cassette Inverter AUUQ18GH2 AUUQ24GH2 Indoor ATNQ18GPLE5 ATNQ24GPLE5 Capacity Cooling Min/Rated/Max kw 1.6 ~ 5.0 ~ 6.5 1.9 ~ 7.0 ~ 8.0 Btu/h 5,500 ~ 17,060 ~22,000 6,460 ~ 23,880 ~ 27,430 Power Input (Set) Cooling Rated kw 1.45 2.16 Running Current Cooling Rated A 6.3 9.4 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.45 3.24 Air Flow Rate Cooling H/M/L m³/min 17.0 / 15.0 / 13.0 18.0 / 16.0 / 14.0 Sound Pressure Cooling H/M/L dba 36 / 34 / 32 40 / 38 / 36 Dimensions Body W*H*D mm 840*204*840 840*204*840 Net Weight Net kg 19.6 19.7 Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Drain O.D./I.D. mm 32.0 / 25.0 32.0 / 25.0 Model PT-UMC1 PT-UMC1 Decoration Panel Color Morning Fog Morning Fog Dimensions W*H*D mm 950*25*950 950*25*950 Weight kg 5.0 5.0 Outdoor AUUQ18GH2 AUUQ24GH2 Compressor Type Twin Rotary Twin Rotary Airflow Rate m³/minxno. 47 x 1 50 x 1 Sound Pressure Cooling Nom dba 47 48 Dimensions Body W*H*D mm 770*545*288 870*655*320 Net Weight kg 35.3 41 Type R410A R410A Charge g 800 1000 Additional Charge (after 10m) g/m 20 20 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 Power Supply Cable No.xmm² 3C*2.5 3C*2.5 Circuit Breaker A 20 25 Piping Length Total Max m 30 50 Piping Elevation Difference IDU-ODU Max m 15 30 Piping Connection Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) 34 2015 LG Air Conditioners 35

3 3 Cassette Inverter AUUQ30LH1 AUUQ36LH1 Indoor ATNQ30GMLE3 ATNQ36GMLE3 Capacity Cooling Min/Rated/Max kw 3.52 ~ 8.79 ~ 10.26 4.00 ~ 10.55 ~ 11.43 Btu/h 12,000 ~ 30,000 ~ 35,000 13,600 ~ 36,000 ~ 39,000 Power Input (Set) Cooling Rated kw 2.26 3 Running Current Cooling Rated A 4.00 4.90 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.89 3.52 Air Flow Rate Cooling H/M/L m³/min 30.0 / 28.0 / 26.0 30.0 / 28.0 / 26.0 Sound Pressure Cooling H/M/L dba 43 / 41 / 39 43 / 41 / 39 Dimensions Body W*H*D mm 840*288*840 840*288*840 Net Weight Net kg 24.6 24.6 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 32.0 / 25.0 Ø 32.0 / 25.0 Model PT-UMC1 PT-UMC1 Decoration Panel Color Morning Fog Morning Fog Dimensions W*H*D mm 950*25*950 950*25*950 Weight kg 5.0 5.0 Outdoor AUUQ30LH1 AUUQ36LH1 Compressor Type Twin Rotary Twin Rotary Airflow Rate m³/minxno. 60 x 1 60 x 1 Sound Pressure Cooling Nom dba 52 52 Dimensions Body W*H*D mm 950*834*330 950*834*330 Net Weight kg 65 65 Type R410A R410A Charge g 1,900 1,900 Additional Charge (after 10m) g/m 20 20 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48 Power Supply ø/v/hz 380-415, 3, 50/60 380-415, 3, 50/60 Power Supply Cable No.xmm² 5C*2.5 5C*2.5 Circuit Breaker A 20 20 Piping Length Total Max m 50 50 Piping Elevation Difference IDU-ODU Max m 30 30 Piping Connection Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Cassette Inverter AUUQ42LH1 AUUQ48LH1 AUUQ54LH1 Indoor ATNQ42GMLE3 ATNQ48GMLE3 ATNQ54GMLE3 Capacity Cooling Min/Rated/Max kw 5.00 ~ 12.31 ~ 13.19 5.67 ~ 14.07 ~ 14.95 6.32 ~ 15.8 ~ 16.6 Btu/h 17,000 ~ 42,000 ~ 45,000 19,000 ~ 48,000 ~ 51,000 21,600 ~ 53,900 ~ 56,600 Power Input (Set) Cooling Rated kw 3.75 4.66 5.23 Running Current Cooling Rated A 6.00 7.8 9.2 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.28 3.02 3.02 Air Flow Rate Cooling H/M/L m³/min 32.0 / 30.0 / 28.0 32.0 / 30.0 / 28.0 32.0 / 30.0 / 28.0 Sound Pressure Cooling H/M/L dba 44 / 42 / 40 44 / 42 / 40 44 / 42 / 40 Dimensions Body W*H*D mm 840*288*840 840*288*840 840*288*840 Net Weight Net kg 28.0 28.0 28.0 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 32.0 / 25.0 Ø 32.0 / 25.0 Ø 32.0 / 25.0 Model PT-UMC1 PT-UMC1 PT-UMC1 Decoration Panel Color Morning Fog Morning Fog Morning Fog Dimensions W*H*D mm 950*25*950 950*25*950 950*25*950 Weight kg 5.0 5.0 5.0 Outdoor AUUQ42LH1 AUUQ48LH1 AUUQ54LH1 Compressor Type Twin Rotary Twin Rotary Twin Rotary Airflow Rate m³/minxno. 60 x 1 60 x 1 55 x 2 Sound Pressure Cooling Nom dba 56 56 55 Dimensions Body W*H*D mm 950*834*330 950*834*330 950*1,380*330 Net Weight kg 67 67 96 Type R410A R410A R410A Charge g 2,300 2,300 3,300 Additional Charge (after 10m) g/m 20 20 40 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48-5~48 Power Supply ø/v/hz 380-415, 3, 50/60 380-415, 3, 50/60 380-415, 3, 50/60 Power Supply Cable No.xmm² 5C*2.5 5C*2.5 5C*2.5 Circuit Breaker A 20 20 20 Piping Length Total Max m 50 50 50 Piping Elevation Difference IDU-ODU Max m 30 30 30 Piping Connection Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 19.05 (3/4) 36 2015 LG Air Conditioners 37

CEILING CONCEALED DUCT [ Inverter ] E.S.P. (External Static Pressure) Control E.S.P. control function can make air volume controlled easily with remote controller. The BLDC motor can control fan speed and air volume regardless of the external static pressure. No additional accessories are necessary to control air flow. E.S.P. Control Short Piping Over Cooling / Heating Comfort Cooling / Heating Long Piping Weak Cooling / Heating Comfort Cooling / Heating High Head Drain Pump High head drain pump automatically drains water up to 200mm of drain-head height. It provides perfect solution for water drainage. (H-Inverter : Included / Standard Inverter : Accessory (ABDPG) / Low-static duct : Included) Drain pipe slope (1/50~1/100) Fixture Drain pipe Water drainage up to 700mm 300mm 450mm Flexible drain hose Available for natural drainage Detachable drain pump 38 2015 LG Air Conditioners 39

Two Thermistors Control The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment. Compares temperatures sensed from different positions, and automatically selects the optimum temperature for users Remote Controller Thermistor Indoor Unit Thermistor Quiet Operation The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain connection pipe. 78dB(A) Low Static Duct 9kBtu 12kBtu 18kBtu 24kBtu Sound Pressure (High / Medium /Low) db(a) 31 / 26 / 25 33 / 31 / 26 36 / 34 / 31 39 / 35 / 32 25dB(A) 40dB(A) Library 50dB(A) Talking 55dB(A) Office Typing Operation for Multiple Rooms Using a spiral duct (embedded or flexible type) and stream chamber, it is possible to operate cooling / heating for several rooms simultaneously. Flexible Installation (Low static duct only) The new low static duct allows the air intake at the rear or bottom under installation condition. New Low Static Duct Air intake at the only rear Air intake at the rear or bottom 40 2015 LG Air Conditioners 41

Minimized Height New mid-static ducts provide ideal solution for installation in limited space. 270mm Maximized E.S.P. (External Static Pressure) New Middle static ducts improve E.S.P up to 140pa(14mmAq). Easy Service & Maintenance 8/10kW 298mm Upper limit of E.S.P (External Static Pressure) 10mmAq 8mmAq 270mm 12.5kW Users don t need to open whole panel for maintenance, since panel is divided into one for heat exchanger and one for fan/motor. Easily detach and attach the filter even in limited space. New 10mmAq 8mmAq 10mmAq 380mm 14mmAq 10mmAq 270mm New New 18kBtu 24kBtu 48kBtu 54kBtu 14mmAq 1 CONCEALED DUCT I Low Static Inverter Indoor ABNQ09GL1A0 ABNQ12GL2A0 Capacity Cooling Min/Rated/Max kw 1.10 ~ 2.50 ~ 3.20 1.40 ~ 3.40 ~ 3.70 Btu/h 3,800~8,500~10,900 4,800~11,600~12,600 Power Input (Set) Cooling Rated kw 0.70 1.00 Running Current Cooling Rated A 3.1 4.3 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.57 3.40 Air Flow Rate Cooling H/M/L m³/min 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 External Static Pressure Pa (mmaq) 39 (4) 39 (4) Sound Pressure Cooling H/M/L dba 31 / 26 / 25 33 / 31 / 26 Dimensions Body W*H*D mm 700*190*700 900*190*700 Net Weight Net kg 20.5 20.5 Liquid mm(inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Piping Connection Gas mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Drain O.D./I.D. mm Ø 32.0 / 25.0 Ø 32.0 / 25.0 Outdoor ABUQ09GL1A0 ABUQ12GL2A0 Compressor Type Rotary Rotary Airflow Rate m³/minxno. 32 x 1 32 x 1 Sound Pressure Cooling Nom dba 47 47 Dimensions Body W*H*D mm 770*540*245 770*540*245 Net Weight kg 32.0 32.0 Type R410A R410A Charge g 1,000 1,000 Additional Charge (after 10m) g/m 20 20 Operation Range (Outdoor) Cooling Min~Max C DB -10~43-10~43 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 Power Supply Cable No.xmm² 3C*2.5 3C*2.5 Circuit Breaker A 15 15 Piping Length Total Max m 15 15 Piping Elevation Difference IDU-ODU Max m 10 10 Piping Connection Liquid mm(inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Gas mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) ABUQ09GL1A0 ABUQ12GL2A0 Front Panel (Heat Exchanger) Rear Panel (Fan / Motor) Easily detach / Attach Filter 42 2015 LG Air Conditioners 43

1 CONCEALED DUCT I Low Static Inverter AUUQ18GH2 Indoor ABNQ18GL2A1 ABNQ24GL3A1 Capacity Cooling Min/Rated/Max kw 1.4 ~ 5.0 ~ 5.6 1.9 ~ 7.0 ~ 8.0 Btu/h 4,740~17,060~18,960 6,460~23,880~27,430 Power Input (Set) Cooling Rated kw 1.54 2.31 Running Current Cooling Rated A 6.7 10 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.25 3.03 Air Flow Rate Cooling H/M/L m³/min 15.0 / 12.5 / 10.0 20.0 / 16.0 / 12.0 External Static Pressure Pa (mmaq) 25 (2.54) 25 (2.54) Sound Pressure Cooling H/M/L dba 36 / 34 / 31 39 / 35 / 32 Dimensions Body W*H*D mm 900*190*700 1,000*190*700 Net Weight Net kg 23.0 27.0 Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 25.4(1)/20.4(13/16) Ø 25.4(1)/20.4(13/16) Outdoor AUUQ18GH2 AUUQ24GH2 Compressor Type Twin Rotary Twin Rotary Airflow Rate m³/minxno. 47 x 1 50 x 1 Sound Pressure Cooling Nom dba 47 48 Dimensions Body W*H*D mm 770*545*288 870*655*320 Net Weight kg 35.3 41 Type R410A R410A Charge g 800 1000 Additional Charge (after 10m) g/m 20 20 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 Power Supply Cable No.xmm² 3C*2.5 3C*2.5 Circuit Breaker A 20 25 Piping Length Total Max m 30 50 Piping Elevation Difference IDU-ODU Max m 15 30 Piping Connection Liquid mm(inch) 6.35 (1/4) 9.52 (3/8) Gas mm(inch) 12.7 (1/2) 15.88 (5/8) AUUQ24GH2 1 CONCEALED DUCT I Middle Static Inverter AUUQ18GH2 AUUQ24GH2 Indoor ABNQ18GM1A2 ABNQ24GM1A2 Capacity Cooling Min/Rated/Max kw 1.4 ~ 5.0 ~ 5.7 2.1 ~ 7.0 ~ 8.8 Btu/h 4,870 ~ 17, 060 ~ 19,500 7,030 ~ 23,880 ~ 24,170 Power Input (Set) Cooling Rated kw 1.65 2.16 Running Current Cooling Rated A 7.2 9.4 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.03 3.24 Air Flow Rate Cooling H/M/L m³/min 16.5 / 14.5 / 13.0 18.0 / 16.5 / 14.0 External Static Pressure Pa (mmaq) 78 (8) 78 (8) Sound Pressure Cooling H/M/L dba 37 / 39 / 36 42 / 39 / 36 Dimensions Body W*H*D mm 900*270*700 900*270*700 Net Weight Net kg 23.1 24.2 Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 32.0(1-1/4) / 25.0(31/32) Ø 32.0(1-1/4) / 25.0(31/33) Outdoor AUUQ18GH2 AUUQ24GH2 Compressor Type Twin Rotary Twin Rotary Airflow Rate m³/minxno. 47 x 1 50 x 1 Sound Pressure Cooling Nom dba 47 48 Dimensions Body W*H*D mm 770*545*288 870*655*320 Net Weight kg 35.3 41 Type R410A R410A Charge g 800 1000 Additional Charge (after 10m) g/m 20 20 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 Power Supply Cable No.xmm² 3C*2.5 3C*2.5 Circuit Breaker A 20 25 Piping Length Total Max m 30 50 Piping Elevation Difference IDU-ODU Max m 15 30 Piping Connection Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) 44 2015 LG Air Conditioners 45

3 3 CONCEALED CONCEALED DUCT I Middle Static DUCT I Middle Static Inverter AUUQ30LH1 AUUQ36LH1 Indoor ABNQ30GGLA0 ABNQ36GGLA0 Capacity Cooling Min/Rated/Max kw 3.52 ~ 8.79 ~ 10.26 4.00 ~ 10.55 ~ 11.43 Btu/h 12,000 ~ 30,000 ~ 35,000 13,600 ~ 36,000 ~ 39,000 Power Input (Set) Cooling Rated kw 2.29 3.35 Running Current Cooling Rated A 4.00 5.70 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.84 3.15 Air Flow Rate Cooling H/M/L m³/min 32.0 / 29.0 / 26.0 32.0 / 29.0 / 26.0 External Static Pressure Pa (mmaq) 98 (10) 98 (10) Sound Pressure Cooling H/M/L dba 42 / 39 / 36 42 / 39 / 36 Dimensions Body W*H*D mm 1,180*298*450 1,180*298*450 Net Weight Net kg 35.0 35.0 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 25.4 / 20.4 Ø 25.4 / 20.4 Outdoor AUUQ30LH1 AUUQ36LH1 Compressor Type Twin Rotary Twin Rotary Airflow Rate m³/minxno. 60 x 1 60 x 1 Sound Pressure Cooling Nom dba 52 52 Dimensions Body W*H*D mm 950*834*330 950*834*330 Net Weight kg 65 65 Type R410A R410A Charge g 1,900 1,900 Additional Charge (after 10m) g/m 20 20 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48 Power Supply ø/v/hz 380-415, 3, 50/60 380-415, 3, 50/60 Power Supply Cable No.xmm² 5C*2.5 5C*2.5 Circuit Breaker A 20 20 Piping Length Total Max m 50 50 Piping Elevation Difference IDU-ODU Max m 30 30 Piping Connection Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Inverter AUUQ42LH1 AUUQ48LH1 AUUQ54LH1 Indoor ABNQ42GRLA0 ABNQ42GRLA0 ABNQ48GRLA0 Capacity Cooling Min/Rated/Max kw 5.00 ~ 12.31 ~ 13.19 5.67 ~ 14.07 ~ 14.95 6.32 ~ 15.8 ~ 16.6 Btu/h 17,000 ~ 42,000 ~ 45,000 19,000 ~ 48,000 ~ 51,000 21,600 ~ 53,900~ 56,600 Power Input (Set) Cooling Rated kw 3.72 4.66 5.23 Running Current Cooling Rated A 6.00 7.80 9.20 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.31 3.02 3.02 Air Flow Rate Cooling H/M/L m³/min 38.0 / 36.0 / 32.0 40.0 / 35.0 / 30.0 50.0 / 45.0 / 40.0 External Static Pressure Pa (mmaq) 98 (10) 98 (10) 98 (10) Sound Pressure Cooling H/M/L dba 44 / 42 / 40 44 / 42 / 40 46 / 44 / 42 Dimensions Body W*H*D mm 1,230*380*590 1,230*380*590 1,230*380*590 Net Weight Net kg 52.0 52.0 49.0 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 19.05 (3/4) Drain O.D./I.D. mm Ø 25.4 / 20.4 Ø 25.4 / 20.4 Ø 25.4 / 20.4 Outdoor AUUQ42LH1 AUUQ48LH1 AUUQ54LH1 Compressor Type Twin Rotary Twin Rotary Twin Rotary Airflow Rate m³/minxno. 60 x 1 60 x 1 55 x 2 Sound Pressure Cooling Nom dba 56 56 55 Dimensions Body W*H*D mm 950*834*330 950*834*330 950*1,380*330 Net Weight kg 67 67 96 Type R410A R410A R410A Charge g 2,300 2,300 3,300 Additional Charge (after 10m) g/m 20 20 40 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48-5~48 Power Supply ø/v/hz 380-415, 3, 50/60 380-415, 3, 50/60 380-415, 3, 50/60 Power Supply Cable No.xmm² 5C*2.5 5C*2.5 5C*2.5 Circuit Breaker A 20 20 20 Piping Length Total Max m 50 50 50 Piping Elevation Difference IDU-ODU Max m 30 30 30 Piping Connection Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 19.05 (3/4) 46 2015 LG Air Conditioners 47

Floor Standing [ Inverter ] Stylish Design The new LG floor standing air conditioner which is Red Dot design award winner 2013, is ideal for modern interiors in your home or office. Quick Response Offering powerful cooling, the commercial air conditioning system can reach a set temperature in a shorter period of time. Meanwhile, the Power Heating function provides the optimal airflow angle, guaranteeing a faster heating performance. Cooling Heating Indoor temp. ( C) 33 3min. 20sec. 4min. 10sec. Indoor temp. ( C) 24 7min. 8min. 10sec. 50sec. 24 12 New Time New Time Powerful Air Flow The new LG floor standing air conditioner is efficient for using in large areas due to its powerful cooling and heating operation. The powerful air speed and volume means the air flow can reach up to 20m away from the air conditioner. 20m 48 2015 LG Air Conditioners 49

1 3 Floor Floor Standing Standing Inverter AUUQ36GH2 AUUQ48GH2 Indoor APNQ36GRA2 APNQ48GTA2 Capacity Cooling Min/Rated/Max kw 3.2 ~ 10.0 ~ 11.3 3.6 ~ 13.4 ~ 14.5 Btu/h 11,010 ~ 34,120 ~ 38,520 12,360 ~ 45,720 ~ 49,430 Power Input (Set) Cooling Rated kw 3.3 4.42 Running Current Cooling Rated A 14.3 19.2 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.03 3.03 Air Flow Rate Cooling H/M/L m³/min 23.5 / 21.0 / 17.0 / 14.0 38.0 / 32.0 / 28.0 / 24.0 Sound Pressure Cooling H/M/L dba 54 / 50 / 46 / 43 56 / 53 / 50 / 47 Dimensions Body W*H*D mm 590*1,840*320 590*1,840*460 Net Weight Net kg 36.0 49.0 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 21.0(13/16) / 17(21/32) Ø 21.0(13/16) / 17(21/32) Outdoor AUUQ36GH2 AUUQ48GH2 Compressor Type Twin Rotary Twin Rotary Airflow Rate m³/minxno. 58 x 1 58 x 1 Sound Pressure Cooling Nom dba 51 55 Dimensions Body W*H*D mm 950 834 330 950 834 330 Net Weight kg 56 61.5 Type R410A R410A Charge g 1500 1900 Additional Charge (after 10m) g/m 20 20 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 Power Supply Cable No.xmm² 3C*2.5 3C*6.0 Circuit Breaker A 30 40 Piping Length Total Max m 50 50 Piping Elevation Difference IDU-ODU Max m 30 30 Piping Connection Liquid mm(inch) 9.52 (3/8) 9.52 (3/8) Gas mm(inch) 15.88 (5/8) 15.88 (5/8) Inverter AUUQ30LH1 / AUUQ36LH1 AUUQ42LH1 / AUUQ48LH1 Indoor APNQ30GRA1 APNQ36GRA1 APNQ42GTA1 APNQ48GTA1 Capacity Cooling Min/Rated/Max kw 3.52~8.79~10.26 4.00~10.55~11.43 5.00~12.31~13.19 5.67~14.07~14.95 Btu/h 12,000~30,000~35,000 13,600~36,000~39,000 17,000~42,000~45,000 19,000~48,000~51,000 Power Input (Set) Cooling Rated kw 2.6 3.6 4.13 4.42 Running Current Cooling Rated A 4.30 5.80 6.70 7.50 Power Supply ø/v/hz 220-240, 1, 50/60 220-240, 1, 50/60 220-240, 1, 50/60 220-240, 1, 50/60 EER 3.38 2.93 2.98 3.18 Air Flow Rate Cooling H/M/L m³/min 23.5/21.0/17.0/14.0 23.5/21.0/17.0/14.0 38.0/32.0/28.0/24.0 38.0/32.0/28.0/24.0 Sound Pressure Cooling H/M/L dba 54 / 50 / 46 / 43 54 / 50 / 46 / 43 56 / 53 / 50 / 47 56 / 53 / 50 / 47 Dimensions Body W*H*D mm 590*1,840*320 590*1,840*320 590*1,840*460 590*1,840*460 Net Weight Net kg 36.0 36.0 49.0 49.0 Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Piping Connection Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) Drain O.D./I.D. mm Ø 21.0 / 17.0 Ø 21.0 / 17.0 Ø 21.0 / 17.0 Ø 21.0 / 17.0 Outdoor AUUQ30LH1 AUUQ36LH1 AUUQ42LH1 AUUQ48LH1 Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin Rotary Airflow Rate m³/minxno. 60 x 1 60 x 1 60 x 1 60 x 1 Sound Pressure Cooling Nom dba 52 52 56 56 Dimensions Body W*H*D mm 950*834*330 950*834*330 950*834*330 950*834*330 Net Weight kg 65 65 67 67 Type R410A R410A R410A R410A Charge g 1,900 1,900 2,300 2,300 Additional Charge (after 10m) g/m 20 20 20 20 Operation Range (Outdoor) Cooling Min~Max C DB -5~48-5~48-5~48-5~48 Power Supply ø/v/hz 380-415, 3, 50/60 380-415, 3, 50/60 380-415, 3, 50/60 380-415, 3, 50/60 Power Supply Cable No.xmm² 5C*2.5 5C*2.5 5C*2.5 5C*2.5 Circuit Breaker A 20 20 20 20 Piping Length Total Max m 50 50 50 50 Piping Elevation Difference IDU-ODU Max m 30 30 30 30 Piping Connection Liquid mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8) Gas mm(inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8) 50 2015 LG Air Conditioners 51