HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Similar documents
Dual Tower Heat Reactivated Desiccant Air Dryer

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Single Tower Heat Reactivated Desiccant Air Dryer

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

CLEAN, DRY COMPRESSED AIR

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

TWP & TWB Series Externally Heated and Blower Purge Desiccant Air Dryers

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

Externally Heated Exhaust Purge Regenerative Compressed Air Dryer

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

clean, dry compressed air

DESICCANT AIR DRYERS. BD + CD + CD series

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

SULLAIR DESICCANT DRYERS

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

Heatless Air Dryers AIRTEK PREMIUM PRODUCTS FOR INDUSTRY. TW Series

Desiccant Air Dryers. Heatless, Heated and Heated Blower

DESICCANT AIR DRYERS. BD + CD + CD series

Externally Heated Desiccant Air Dryer RP Series

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

HEATLESS DESICCANT AIR DRYERS

Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM

Pressure Swing Desiccant Dryers

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

NGV Fueling Station Dryers. FSD-A, FSD-T, FSD-M and MRS Series Catalog

REFRIGERATED AIR DRYERS

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

DGH Series Global Air Treatment

Hybrid Refrigerated/Desiccant Compressed Air Dryers

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

Regenerative Desiccant Dryers. KAD, KED, KBD, and Hybritec Series. kaeser.com

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Desiccant Regenerative Dryers 3-10,000 scfm

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

Heated purge desiccant compressed air dryers. hpd Series

Unique, Energy-Saving Models HC & SP World Leader in Regenerative Dryer Technology

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Blower Purge Desiccant Compressed Air Dryer. HBP SERIES 500-4,300 SCFM ( nm 3 /h)

Overview of HL series heatless regenerative dryers.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

PET Drying Technology

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

ingersoll rand desiccant dryers

Heatless Desiccant Air Dryers. HHS SERIES, HHL SERIES AND HHE SERIES 40 to 5400 scfm (68 to 9175 nm 3 /h)

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

Product Catalogue Edition 1


Quality Components as a basis for Quality Equipment

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES

CDH Series Heatless Desiccant Dryers CFM

industry revolves around VDWM Wall Mount Desiccant Dryer 7 50 SCFM

Adsorption Compressed Air Dryer Heatless or heater regeneration

CHC Series High Capacity Refrigerated Dryer 2,000 20,000 SCFM

COMPRESSED AIR TREATMENT

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

CDWM Series Wall Mount Desiccant Dryer 7 50 SCFM

HEATLESS REGENERATIVE DRYERS

Blower Purge Desiccant Dryers. CAB SERIES 1,238-12,915 scfm

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

Compressed Air Filters

SECTION AIR COMPRESSORS AND ACCESSORIES

Landfill & Digester Gas Dryers. Features and Benefits

Scroll Medical Air Compressor with Premium NFPA Control Panel

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Benefits of Desiccant Dryer Dew Point & Purge Control

Heat of Compression Desiccant Air Dryers. NRG-LES SERIES scfm ( nm 3 /h)

DHA Series Externally Heated & DBA Series Blower Purge Adsorption Dryers

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

EXTERNALLY HEATED DESICCANT AIR DRYERS. DHP Series

Equipment Designed for Industrial Applications

Refrigerated & Desiccant Compressed Air Dryer Product Selector

CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Heated Desiccant Air Dryer

Modular Adsorption Dryers

RNC Series SCFM Global Air Treatment

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

Flexible Solutions for Air Quality

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

White paper Compressed air drying

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

CNC Series Refrigerated Air Dryer CFM

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

MANUFACTURED with high-quality components and innovative techniques. DESIGNED for economical, trouble-free performance and long-life reliability

The leader in gas dehydration & filtration

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

Transcription:

Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products

Moisture in compressed air is damaging. Without proper treatment, this vital energy source is a wet, gritty, acidic brew, silently destroying all that it comes in contact with. hold the key for systems requiring high quality, reliable air in an energy efficient package. By installing an Eastern Air HR Externally Heated or HB Blower Purge dryer Eliminate Water from Your Compressed Air System In today s competitive industrial markets, dry compressed air is a necessity not a luxury. The Eastern Air Products Genesis Series of Heat Reactivated compressed air dryers the user will see immediate results in the removal of moisture and contaminants from their system. While there are many different applications where heated desiccant dryers apply, no two applications are exactly alike. system operation after only a few minutes of interaction. Because the EAP heated dryer is provided with three independent exhaust Genesis Heated Dryers Upon installation, there are a number of variables within the operating environment where the dryer may be located. Through EAP s exclusive process of Tuned Regeneration, the user can dovetail the dryer regeneration process to achieve optimal results. Overall KW reduction and alleviation of dew point bumps can be realized through a process of tuning the interactive settings in the Logic Pro Master Controller. Understanding the Master Controller is so easy, most users are comfortable with system temperature readouts, the user can quickly see the heating pattern of the regeneration tower. Adjustments to heating temperature, duration and cycling controls can all be made without the need for costly programming. Slight adjustments from winter to summer months can result in maintaining system peak operational efficiency, while reducing energy usage. Adjustments of cooling cycles can reduce dew point spikes and maximize air volume available to process.

EAP Genesis heat reactivated desiccant dryers use the adsorption method to remove saturated compressed air flows through the drying tower, its moisture content adheres to the surface System Flow Schematics moisture from compressed air. Pressure dew points of minus 40 0 F/C to as low as -70 0 F (-56 0 C) are achieved by directing the flow of saturated compressed air over a bed of desiccant. As the of the desiccant, resulting in reduced relative humidity and optimal dew points. The dried process air is final polished by micron filter and sent to the plant air distribution system. In order to fully and effectively regenerate the off line saturated tower of the HR series, EAP utilizes the most advanced and highly tuned procedure in the industry. A regulated amount of already dried process air (approx. 7%) is heated by way of a low watt density heater and passed down (counter current) through the desiccant bed. This heated purge air, exhausted to atmosphere, removes all of the collected moisture adhered to the desiccant from the previous drying Air Out Air Out HR Regeneration Pre Exhaust Valve Main Exhaust Valve Inlet Valve HB Regeneration Air In Air In Pre Exhaust Valve Main Exhaust Valve Inlet Valve The EAP HB series of dryers also use heated air to regenerate the off line tower. However none of the process air is used during regeneration. A high efficient packaged blower assembly directs only heated atmospheric air counter current through the desiccant bed, removing all of the moisture that was collected during the previous drying cycle. Dew point spikes or heat bump can be avoided by tuning the regeneration cycle to meet the application. Energy (KW) requirements are greatly reduced through the use of our exhaust system temperature controllers. HR & HB Features Upon achievement of optimal temperatures in the regenerating tower, the heater system is turned off and the tower is cooled in preparation for its return to the drying process. Cooling and dry purge cycles can be customized to provide the best regeneration results. All EAP heated Dryers are equipped with fail-safe, and heat-safe directional valves. Should there be a power failure or emergency stop the inlet air directional system will maintain its exact position, locking out the regeneration tower. This protects the user from allowing excessive heated purge to enter the distribution system, which can affect process and damage downstream pneumatic devices. Upon restoration of power, the retentive memory systematically steps the dryer back into process condition without interaction from the user, and without affecting the duration of the current regeneration.

With a combination of quality name brand components, superior craftsmanship and a software package delivering on EAP s many years of experience, Logic Pro represents a revolution in simplifying dryer control. Logic Pro Master Controllers All EAP dryers capitalize on the superior performance of Allen-Bradley PLC Controllers. Allen-Bradley controllers are established as highly reliable, repeatable, and expandable and are common within industrial controls environments. There is no need to open the control panel or access any internal working components of the control box. All functions are easily managed and displayed on the interactive panel mount controls. Chances are, when you purchase and EAP heated dryer, your facility operations team is likely already familiar with our controls platform. User Interface / Low Voltage Control Box Interactive control system with visual indication of current condition Run/Standby Mode Heatless Back Up Mode Cycle Stepping Interactive controls allow user to dovetail operational set points Temperature indication package with digital display and alarm Exhaust Temperature Monitors (Saves Energy) EcoTronic Dew Point Control (with EcoTronic Option) Digital Dew Point Readout High Humidity Alarm Communications through Allen Bradley Controller Emergency Stop Durable sheet metal cabinet All Components independently fused to UL and CSA standards Primary Voltage Control Box Lockable, gasket NEMA enclosures Service disconnect switch Single point connections Dual contactors for heater control Primary cycling contactor controls heater operation Secondary over-temperature contactor protects circuit Redundant contactors provide the ultimate in heater system protection Built-in fused secondary voltage transformer Blower overload protection and motor starters

Allen Bradley Touch Pad with Interactive Menu Search Full on-board temperature and pressure menu with interactive set points and alarms Retentive alarm log with fault code readout and time stamping Communications package for remote monitoring (MODBUS RTU Standard, other languages available, consult factory) Step by step countdown timers for all operations Interactive service menu allowing direct control of parameters Ecotronic Demand Control Available Options All EAP dryers equipped with the Logic Pro Heated Dryer Controller are pre programed to accept the 4-0mA loop from the Ecotronic moisture analyzer probe. The Ecotronic provides numerous benefits over a system that operates exclusively on an 8 hour NEMA cycle. Demand Cycle Operation Unit only switches when the dew point achieves user desired set point (factory set at -40 0 F/C). Significant energy savings are realized by reduction of blower and heater KW consumption and purge. Digital Dew Point Readout High Humidity Alarm with Output 4-0 ma Output Standard Unit continuously displays outlet dew point quality of air, and is visible on all menu screens. High dew point alarm is adjustable and flashed on main menu should upset condition occur. The significance of protecting a desiccant dryer system with suitable filtration cannot be understated. If incoming air is not filtered of oils, liquids Packaged Filters - Complete Air Treatment System and aerosols, contamination of the desiccant material will occur, leading to an eventual system failure. To keep your system operating at peak efficiency, Eastern Air Products recommends factory installed filtration systems, designed and matched directly to the dryer and mounted on a common base. The resulting package reflects a complete air treatment system which provides easier installation, single point connections and data acquisition functions from a single Logic Pro control system. All EAP Heat Reactivated Air Dryers come complete with the pre and after filters mounted and piped. The 0.0 micron coalescing pre filter (equipped with and auto drain/isolation service valve) and pressure differential indicator, ensures that oil aerosols and bulk liquids do not enter the inlet flow and contaminate the desiccant bed. The micron particulate after-filter will remove any solids for truly polished and ultra clean, dry compressed air. Depending on your application, EAP can supply an assortment of filter configurations to suit your specific needs.

While there are many applications where heated desiccant dryers are the right choice for drying compressed air, no two installations are quite the same in terms Interactive Allen Bradley Controllers of operations. All EAP dryers are provided with our advanced software package that allows the operations engineer to dovetail dryer operating set points to actual operating conditions. The ability to make fine adjustments to dryer operations in the field ensures the highest quality air to process, while reducing service and maintenance costs. All EAP HR and HB dryers are constructed using premium actuated positioning valves to direct the inlet flow of compressed air. Premium Non-Lubricated Rotary Actuated Valves All inlet directional valves are dual acting to assure proper air flow and continued operation even in a system fault condition or power outage. These premium valves are so reliable they carry a 3 year factory warranty. All components are sourced from reputable USA manufactures so both product quality and support are second to none. Standard EAP dryers exclusively use high quality USA manufactured activated alumina desiccants. These desiccants have a high surface to mass ratio, high crush strength and are Premium Quality Desiccants designed specifically for air dehydration applications. For systems requiring extremely low dew points, EAP offers USA produced Molecular sieve as a polishing layer in combination with an alumina base layer. Through the use of EAP s exclusive and patent pending process of Tuned Regeneration, the HR and HB heated dryers use only the energy required to provide a gentle and Premium Non-Lubricated Rotary Actuated Valves consistent low pressure air-flow to desorb the accumulated moisture from the regeneration tower. Continuous exhaust air temperature monitoring further reduces energy consumption by controlling heating cycle duration on demand. Equipment Touch Pad Interactive Display Screen ASME/CRN code pressure vessels Logic Pro Advanced Control System Field adjustable operating parameters System Run/Standby Selector switch Emergency stop button and alarm Premium Inlet Switching Valves with 3 year warranty Separate High and Low Voltage Control Boxes with Single Point Power Connections Tri-temp Heater Control System Heater Protection Over-Temperature Shut Down with Alarm Low Watt Density Heaters Exhaust Temperature Monitors w/ early heat temperature feature Tuned Regeneration Temperature Control with dual contactors CRN/CSA approvals for Canada Industrial Duty Blower (HB Only) Control Air Regulating Valve with Gauge and Orifice Union Control Air Filter (Required Only on HR/HB000 and Larger) -40 0 F Pressure Dew Point Standard Adjustable/Selectable % Stripping Cycle (HB Only) Heatless Back-Up Mode Re-Pressurization Circuit Low Temperature Alarm Premium Directional Purge, Outlet and Blower Check Valves rated for high temperature service Premium High Temperature Exhaust Valves Premium USA activated Alumina Desiccant Full Flow Safety Relief Valves Heater Circuit Insulation and Aluminum Jacketing Premium Stainless Steel Bezel Pressure Gauges Tower Moisture Indicators Structural Steel Skids Equipment Lifting Lugs Optional Factory Packaged Filters, Single or Dual Selectable System Bypass Packages (All) EcoTronic Demand Control Tower Insulation Outdoor Jacketing of Insulation Low Flow Alarm Switch Failure Alarm Special Voltage Low Ambient Insulation with Heat Tracing Communications Packages for Remote Monitoring (Standard on HR/HB000 and Larger) 575v/3 Stainless steel control tubing Special Options All Welded Construction Extra Heavy, Non-Yellow Metal Construction Full Base Top Plate or Diamond Plate

Model SCFM @ 00 PSIG Line Size (Inches) Electrics Max Heater KW Approx Purge (SCFM) Dimensions W x D x H (Inches) Unit Weight (lbs) HR00 HR30 HR00 HR300 HR400 HR550 HR650 HR800 HR000 HR50 HR500 HR000 HR600 HR3000 HR4000 HR5000 HR6000 00 30 00 300 400 550 650 800 000 50 500 000 600 3000 4000 5000 6000 / / 4FL 4FL 5V/ 5V/ 5V/3.3.3 3.0 3.0 4.0 5.0 5.0 7.0 9.0.0 5.0 8.0.0 30.0 38.0 50.0 60.0 8 0 5 3 30 4 49 60 75 94 3 35 58 5 300 375 450 46 x 4 x 88 46 x 4 x 88 46 x 4 x 88 50 x 46 x 95 50 x 46 x 98 60 x 50 x 98 60 x 50 x 98 68 x 60 x 00 68 x 60 x 06 80 x 80 x 0 80 x 80 x 90 x 95 x 05 00 x 05 x 05 3 x 0 x 05 3 x 80(46) x 06 60 690 900,90,35,950,5 3,60 4,400 5,50 6,360 7,800 9,800,50 3,080 Dryer Specifications Model SCFM @ 00 PSIG Line Size (Inches) Electrics Max Heater KW Approx Purge (SCFM) Dimensions W x D x H (Inches) Unit Weight (lbs) HB30 30 5V/.3 46 x 4 x 88 545 HB00 00 / 5V/3 3.0 46 x 4 x 88 730 HB300 300 / 5.0 50 x 46 x 95 65 HB400 400 6.0 50 x 46 x 98,480 HB550 550 9.0 3 60 x 50 x 98,30 HB650 650 9.0 3 60 x 50 x 98,450 HB800 800.5 4 68 x 60 x 00 3,580 HB000 000 5.0 4 68 x 60 x 06 4,850 HB50 50 8.0 5 80 x 80 x 0,750 HB500 500 5.0 7 80 x 80 x 6,900 HB000 000 5.0 7 90 x 95 x 05 8,600 HB600 600 4FL 30.0 0 00 x 05 x 05 0,750 HB3000 3000 4FL 50.0 0 3 x 0 x 05,960 HB4000 4000 60.0 5 3 x 80(46) x 06 4,50 * Consult Factory HB5000 5000 75.0 5 All specifications and dimensions subject to change without notice. All units 00 SCFM and larger available with 575/3/60 electrical supply. HB6000 6000 00.0 0 Unites 4000 SCFM and larger with factory packaged filters are provided on two bases designed to bolt together at installation. Correction factor for inlet air pressure (PSIG) 50 60 70 80 90 00 0 0 30 40 50 0.56 0.65 0.74 0.83 0.9.04.08..6. Correction factor for inlet temperature 0 F Capacity Correction Factors 70 80 90 00 05 0 5 0 0 C 7 3 38 40 43 46 49 Factor...06 0.93 0.86 0.8 0.75 Corrected flow = Normal capacity of dryer (SCFM) x inlet pressure factor x inlet temperature factor

Engineered Air Products ph 800.943.794 fax 76.39.885 www.engineeredairproducts.com Patents Pending Made in 04 Engineered Air Products, Lancaster, NY 4086 HBHL- 8.7.4